• Title/Summary/Keyword: PD50

Search Result 328, Processing Time 0.021 seconds

Fine tuning of wavelength for the intenrnal wavelength locker module at 50 GHz composed of the photo-diode array black with the multi-channel tunable laser diodes in DWDM application (DWDM용 다채널 파장 가변 레이저 다이오드 모듈을 위한 다수개의 광 수신 소자를 갖는 50 GHz 내장형 파장 안정화 모듈의 파장 미세 조정)

  • 박흥우;윤호경;최병석;이종현;최광성;엄용성;문종태
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.384-389
    • /
    • 2002
  • A new idea of the wavelength locking module for DWDM application was investigated in the present research. Only one etalon photo-diode is generally used in the internal/external wavelength locking system. For the internal wavelength locking module with 50 GHz applications, an algle tuning method of the etalon commonly applied. However, the alignment process of the etalon with the angle tuning method is limited because the lock performance is extremely sensitive accoriding to the change of the tilting angle. In an optical viewpoint, the alignment tolerance of the locker module with the etalon PD array block was good, and the precise tuning of the wavelength was possible. The characteristics of free spectral range (FSR) and peak shift of wavelength according to the tilting angle with the locker module was investigated. For the present module, the optimized initial tilting angle was experimentally obtained.

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Effect of Bimetallic Pt-Rh and Trimetallic Pt-Pd-Rh Catalysts for Low Temperature Catalytic Combustion of Methane

  • Bhagiyalakshmi, Margandan;Anuradha, Ramani;Park, Sang-Do;Park, Tae-Sung;Cha, Wang-Seog;Jang, Hyun-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.120-124
    • /
    • 2010
  • Monometallic, bimetallic and trimetallic particles consisting of different weight compositions of Pt-Pd-Rh over pure alumina wash coats have been synthesized and their catalytic performance on methane conversion was studied from 150 to $600^{\circ}C$. Different catalyst formulations with variable Pt, Pd and Rh contents for bimetallic and trimetallic systems were tried and $Pt_{(1.5)}Rh_{(0.3)}/Al_2O_3$ and $Pt_{(1.0)}Pd_{(1.0)}Rh_{(0.3)}/Al_2O_3$ shows low $T_{50}$ and $T_{90}$ temperatures. Bimetallic and trimetallic particle synergism acts as three way catalysts and therefore, all the catalysts show 100% methane conversion. The effect of supports such as $ZrO_2$ and $TiO_2$ on methane combustion was investigated; from $T_{50}$ and $T_{90}$ results both $Al_2O_3$ and $ZrO_2$ are suitable supports for low temperature methane combustion.

Characteristics of Pd-MIS devices on hydrogen gas sensing (Pd-MIS 소자의 수소가스 검지 특성)

  • Yi, Cheal W.;Cha, Won I.;Shin, Chee B.;Yun, Kyung S.;Ju, Jeh B.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.3 no.2
    • /
    • pp.17-24
    • /
    • 1992
  • Hydrogen gas sensors were fabricated after the form of metal/insulator/semiconductor(MIS) structure on a p-type silicon wafer and a insulating layer (silicon dioxide) thickness was changed from $500{\AA}$ to $5000{\AA}$. Their electrical properties were investigated with the variation of the hydrogen gas concentration at room temperature. At the applied forward bias of lV to both ends of Pd-MIS sensors the current was decreased logarithmically with the increase of hydrogen concentration in air. In the case of a thin $SiO_2$ layered ($500{\AA}$) sensor the current ratio was decreased to 25 % at 1 % of hydrogen concentration in air and 50% for a thick $SiO_2$ layered ($5000{\AA}$) sensor. And the response time of the thick insulating layered sensor to 1% hydrogen containing air was about 50 seconds and regeneration time was 2.5 minutes. When a 0.5mA current was appied to the thick insulating layered sensor the maximun voltage shift was calculated to 0.8V in the case of ${\theta}$ = 1 and the Pd surface coverage of hydrogen was increased logarithmically with hydrogen partial pressure.

  • PDF

Pd/Ge-based Emitter Ohmic Contacts for AlGaAs/GaAs HBTs (AlGaAs/GaAs HBT 에미터 전극용 Pd/Ge계 오믹 접촉)

  • Kim, Il-Ho
    • Korean Journal of Materials Research
    • /
    • v.13 no.7
    • /
    • pp.465-472
    • /
    • 2003
  • Pd/Ge/Ti/Pt and Pd/Ge/Pd/Ti/Au ohmic contacts to n-type InGaAs were investigated for applications to AlGaAs/GaAs HBT emitter ohmic contacts. In the Pd/Ge/Ti/Pt ohmic contact minimum specific contact resistivity of $3.7${\times}$10^{-6}$ $\Omega$$\textrm{cm}^2$ was achieved by rapid thermal annealing at $^400{\circ}C$/10 sec. In the Pd/Ge/Ti/Au ohmic contact, minimum specific contact resistivity of $1.1${\times}$10^{-6}$ $\Omega$$\textrm{cm}^2$ was achieved by annealing at 40$0^{\circ}C$/10 sec but the ohmic performance was degraded with increasing annealing temperature due to the reaction between the ohmic contact materials and the InGaAs substrate. However, non-spiking planar interface and relatively good ohmic contact (high-$10^{-6}$ /$\Omega$$\textrm{cm}^2$) were maintained after annealing at $450^{\circ}C$/10 sec. Therefore, these thermally stable ohmic contact systems are promising candidates for compound semiconductor devices. RF performance of the AlGaAs/GaAs HBT was also examined by employing the Pd/Ge/Ti/Pt and Pd/Ge/Pd/Ti/Au systems as emitter ohmic contacts. Cutoff frequencies were 63.5 ㎓ and 65.0 ㎓, respectively, and maximum oscillation frequencies were 50.5 ㎓ and 51.3 ㎓, respectively, indicating very successful high frequency operations.

Usage Patterns and Incidence of Thyroid-related Adverse Events in Patients Treated with PD-1 Inhibitors (PD-1 억제제의 사용패턴 및 갑상선 관련 유해사례 발현 양상 분석)

  • Hwang, Seoyoung;Kim, Heuijae;Chung, Seonyoung;Min, Myungsook;Suh, Dong-Churl
    • Korean Journal of Clinical Pharmacy
    • /
    • v.31 no.3
    • /
    • pp.188-197
    • /
    • 2021
  • Objective: PD-1 inhibitors have demonstrated improved health outcomes in cancer patients. PD-1 inhibitors are well-tolerated and associated with immune-related adverse events. The objectives of this study are to analyze use patterns of PD-1 inhibitors in patients with cancer and to investigate the incidence of thyroid-related adverse reactions in patients treated with PD-1 inhibitors. Methods: The study included patients who had been administered PD-1 inhibitors (either nivolumab or pembrolizumab) at the Samsung Medical Center between October 1, 2016 and June 30, 2017. Data was collected from electronic medical records and tested using Mann-Whitney tests and Chi-Square tests for statistical significance. Associations between PD-1 inhibitors and incidence of adverse events were tested using Cox regression for age, gender, BMI, ECOG PS and medication. Results: Two hundred fifteen patients were identified as eligible for analyses. Thyroid-related adverse events occurred in 20% of patients (n=43). Thyroid function tests (TFTs) was performed in 109 patients (50.7%). Positive results of PD-L1 testing were found in 53.2% of the 94 patients who had the test. Approved doses of nivolumab (3 m/kg) and pembrolizumab (200 mg) were administered in 70.4% and 53% of patients, respectively. The analysis of risk factor of thyroid-related adverse reaction did not show statistically significant differences (Cox regression). Conclusion: Thyroid-related adverse events are common in patients treated with PD-1 inhibitors and hypothyroidism is the most frequent adverse reaction. Routine TFTs monitoring is strongly recommended to evaluate thyroid function in real-world clinical practice.

Predictors of discogenic pain in magnetic resonance imaging: a retrospective study of provocative discography performed by posterolateral approach

  • Jain, Anuj;Jain, Suruchi;Barasker, Swapnil Kumar;Agrawal, Amit
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.447-453
    • /
    • 2021
  • Background: Provocative discography (PD) is a test that is useful in diagnosing discogenic pain (DP). In this study, to diagnose DP, we used a posterolateral approach of needle placement and followed pressure criteria laid down by the Spine Intervention Society. The aim was to identify the correlation between magnetic resonance imaging (MRI) findings (desiccation, high intensity zone and change in shape and size of the disc) and the results of PD. Methods: Records of 50 patients who underwent PD for DP were analyzed. A total of 109 PDs were performed, with 54 suspect and 55 control discs. Alternate pain generators were ruled out. Results: A total of 35 suspect discs were positive on PD. The mean disc pressure in the suspect disc was 31.9 ± 7.9 psi (range, 15-44). Of the 50 patients who underwent PD, 35 had positive MRI findings. A significant positive correlation was found only between disc desiccation and discography result (r = 0.6, P < 0.001). Logistic regression analysis revealed that only desiccation successfully predicted the result of discography (OR = 26.5, P < 0.001); a high intensity zone and a disc protrusion/extrusion had an OR 2.3 and 1.24, respectively. Disc desiccation of Pfirmann grade 3 or more had a sensitivity and specificity of 0.93 and 0.64 respectively in identifying painful discs; the positive likelihood ratio was 2.58 while the negative likelihood ratio was 0.11. Conclusions: In patients with DP, disc desiccation is the most useful MRI feature that predicts a painful disc on PD.

Preparation and Gas Permeation Performance of Pd-Ag-Cu Hydrogen Separation Membrane Using α-Al2O3 Support (α-Al2O3 지지체를 이용한 Pd-Ag-Cu 수소 분리막의 제조 및 기체투과 성능)

  • Sung Woo Han;Min Chang Shin;Xuelong Zhuang;Jae Yeon Hwang;Min Young Ko;Si Eun Kim;Chang Hoon Jung;Jung Hoon Park
    • Membrane Journal
    • /
    • v.34 no.1
    • /
    • pp.50-57
    • /
    • 2024
  • In this experiment, Pd-Ag-Cu membrane was manufactured using electroless plating on an α-Al2O3 support. Pd, Ag and Cu were each coated on the surface of the support through electroless plating and heat treatment was performed for 18 h at 500℃ in H2 in the middle of electroless plating to form Pd alloy. The surface of the Pd-Ag-Cu membrane was observed through Scanning Electron Microscopy (SEM), and the thickness of the Pd membrane was measured to be 7.82 ㎛ and the thickness of the Pd-Ag-Cu membrane was measured to be 3.54 ㎛. Energy dispersive X-ray spectroscopy and X-ray diffraction analysis confirmed the formation of a Pd-Ag-Cu alloy with a composition of Pd-78wt%, Ag-8.81wt% and Cu-13.19wt%. The gas permeation experiment was conducted under the conditions of 350~450℃ and 1~4 bar in H2 single gas and H2/N2 mixed gas. The maximum H2 flux of the hydrogen separation membrane measured in H2 single gas is 74.16 ml/cm2·min at 450℃ and 4 bar for the Pd membrane and 113.64 ml/cm2·min at 450℃ and 4 bar for the Pd-Ag-Cu membrane. In the case of the separation factor measured in H2/N2 mixed gas, separation factors of 2437 and 11032 were measured at 450℃ and 4 bar.

$H_2$ sensor for detecting hydrogen in DI water using Pd membrane (수중 수소 감지를 위한 MISFET형 센서제작과 그 특성)

  • Cho, Yong-Soo;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • In this work, Pd/Pt gate MISFET sensor using Pd membrane was fabricated to detect the hydrogen in DI water. A differential pair-type was used to minimize the intrinsic voltage drift of the MISFET. To avoid hydrogen induced drift of the sensor, the silicon dioxide/silicon nitride double layer was used as the gate insulator of the FET's. In order to eliminate the blister formation on the surface of the hydrogen sensing gate metal, Pd/Pt double metal layer was deposited on the gate insulator. For this type of application sensors need to be isolated from the DI water, and a Pd membrane was used to separate the sensor from the DI water. The output voltage change due to the variation of hydrogen concentration is linear from 100ppm to 500 ppm.

  • PDF

Low Temperature lateral Crystallization of Amorphous Silicon Films Induced by Ni and Pd. (Ni과 Pd을 이용한 비정질 실리콘의 저온 측면 결정화에 관한 연구)

  • Lee, Byeong-Il;Kim, Gwang-Ho;Jeong, Won-Cheol;Sin, Jin-Uk;An, Pyeong-Su;Ju, Seung-Gi
    • Korean Journal of Materials Research
    • /
    • v.6 no.9
    • /
    • pp.900-904
    • /
    • 1996
  • 비정질 실리콘의 표면에 Ni과 Pd를 형성하여 측면으로의 결정화 속도를 향상시켰다. Ni에 의해 비정질 실리콘이 측면으로 결정화될 때 그 성장 속도는 50$0^{\circ}C$에서 3w$\mu\textrm{m}$/hour였으며 이때의 활성화 에너지는 2.87eV로 나타났다. Pd의 경우는 Pd2Si의 형성에 의해 압축 응력이 유발되어 Pdrks의 간격이 좁을수록 측면으로의 결정화 속도가 증가하였다. Ni과 Pd을 각각 다른 부분에 증착시키고 결정화시키면 Ni에 의해 측면으로 결정화되는 속도가 Ni만으로 결정화시킬 때 보다 약 2배 이상의 측면결정화 속도를 보였다.

  • PDF