• Title/Summary/Keyword: PD monitoring

Search Result 131, Processing Time 0.022 seconds

Effect of Simulator Sickness Caused by Head-mounted Display on the Stability of the Pupillary Rhythm (머리착용 디스플레이에 의해 유발된 멀미 증상이 동공 리듬의 안정성에 미치는 영향)

  • Park, Sangin;Lee, Don Won;Mun, Sungchul;Kim, Hong-Ik;Whang, Mincheol
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.43-54
    • /
    • 2018
  • The aim of this study is to determine the effect of motion sickness on pupil rhythm. Sixteen volunteers of both genders (8 male, 8 female, mean age $25.67{\pm}2.43$ years) experienced VR contents in both 2D and HMD versions for 15 minutes, and their pupillary rhythms were compared. The irregular pattern of the pupillary rhythms, as demonstrated by increasing mean pupil diameter (mPD) and standard deviation of the pupil diameter (sPD), revealed motion sickness after experiencing HMD condition. The pupillary response is strongly related to the cognitive load, and the motion sickness can be interpreted as a change in the cognitive load caused by the increasing volume of visual information that must be processed and the conflict or inconsistency between different sensory modalities. The method proposed in this study could be a non-contact measurement method for the monitoring of motion sickness using a web-camera rather than previous sensor-based methods.

A Study on the Concept of a Ship Predictive Maintenance Model Reflection Ship Operation Characteristics (선박 운항 특성을 반영한 선박 예지 정비 모델 개념 제안)

  • Youn, Ik-Hyun;Park, Jinkyu;Oh, Jungmo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.53-59
    • /
    • 2021
  • The marine transport industry generally applies new technologies later than other transport industries, such as airways and railways. Vessels require efficient operation, and their performance and lifespan depend on the level of maintenance and management. Many studies have shown that corrective maintenance (CM) and time-based maintenance (TBM) have restrictions with respect to enabling efficient maintenance of workload and cost to improve operational efficiency. Predictive maintenance (PdM) is an advanced technology that allows monitoring the condition and performance of a target machine to predict its time of failure and helps maintain the key machinery in optimal working conditions at all times. This study presents the development of a marine predictive maintenance (MPdM; maritime predictive maintenance) method based on applying PdM to the marine environment. The MPdM scheme is designed by considering the special environment of the marine transport industry and the extreme marine conditions. Further, results of the study elaborates upon the concept of MPdM and its necessity to advancing marine transportation in the future.

Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device (휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발)

  • Gyoung-Hahn Kim;Seong-Woo Woo;Sung Hun Ha;Jinlong Piao;MD Sahin Sarker;Baejeong Park;Chang-Sei Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

Detection of AGN outflows in micro-arcsec scales

  • Oh, Junghwan;Trippe, Sascha;Krichbaum, Thomas;Sohn, Bong Won;Bremer, Michael
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.43.1-43.1
    • /
    • 2013
  • We report the preliminary results of our GMVA(Global mm VLBI Array) observation at the frequency of 86 GHz. Observation were made in the dual polarization mode (LCP and RCP), to produce the polarimetric maps with the maximum angular resolution which the array is capable of. We aim to link the source-integrated AGN polarization properties with the polarized spatial source structure, by mapping the polarized "fine structure" of the target AGN. We selected 2 targets, 0954+658 and 0716+714, which (1) have been observed multiple times by the PdBI polarimetric monitoring program; (2) have sufficient integrated fluxes ($S_{90GHz}$ > 1 Jy) ; (3) are close enough to resolve the source structure < 1 pc with given angular resolution ; and (4) are located at high northern declination for good UV coverages. As preliminary results, we present LL and RR polarized images of each target with the maximum angular resolution of ${\sim}60{\mu}as$. Extended structures, probably the jet outflows, are discovered in both sources.

  • PDF

NO Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect (단층 탄소나노튜브의 일산화질소 가스에 대한 감응특성과 열처리 효과)

  • Kim, Min-Ju;Yun, Kwang-Hyun;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.292-297
    • /
    • 2004
  • Carbon nanotubes (CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in ${\alpha}$-Terpinol($C_{10}H_{17}OH$) solution. The CNT tilms were fabricated by screen printing method on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film was observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NO response and recovery time. The CNT sensor with a heater was compared to that without a heater. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

The Development of String type Tele-operation Controller for 3D Environment (3D작업 수행을 위한 string형 원격 제어기 개발)

  • 심형준;차인혁;한창수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.5
    • /
    • pp.153-160
    • /
    • 1998
  • A master-slave system for tele-operation had been developed and tested for several decades. In this paper the master robot is composed of several wires and provides position information of the handle which is driven by a operator within the master robot work space. A PC is used for the command calculation for a slave robot. This paper deals with the relation between the number of strings and D.O.F of the master robot, control method of the slave robot during the operation and the monitoring method over the working area by the computer graphics simulation. The D.O.F of the master robot can be modified by adding or subtracting some strings. The controller of the slave robot uses the advanced PD control method to keep the performance against varying working load.

  • PDF

Detection and Location of Partial Discharge in Oil Filled Transformer

  • Lee, Seung-Whan;Oh, Hak-Joon;Chung, Chan-Soo;Yun, Man-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.98.3-98
    • /
    • 2001
  • The research for detecting of insulating deterioration in transformer has been studied from long ago. Analysis method of combustible gas, which is included in insulating oil, has been widely used in detection of transformer pre-fault detection due to the effectiveness of its method. Recently the fault effect of the large transformer is very critical in a power system, therefore the on-line monitoring and diagnostic system is needed. In addition, the more accurate method of detecting a Partial Discharge (PD) location should be developed. For preventive maintenance against discharge failures, it is important not only to detect the discharges, but also to accurately estimate their positions. However ...

  • PDF

NH3 Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect (단층 탄소나노튜브의 암모니아 가스에 대한 감응특성과 열처리 효과)

  • Huh J. S;Lee S. T;Kim M. J;Yun K. H
    • Korean Journal of Materials Research
    • /
    • v.14 no.4
    • /
    • pp.276-280
    • /
    • 2004
  • Carbon nanotubes(CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in $\alpha$-Terpinol($C_{10}$ $H_{17}$OH) solution. The CNT films were fabricated by screen printing on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film were observed by scanning electron microscopy (SEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NH$_3$ response and recovery time. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

Evaluation of Nivolumab Use and Factors related to Treatment Outcomes in a Cancer Center of a Top Tier General Hospital (상급종합병원 암센터에서 Nivolumab 사용평가와 치료성과에 미치는 영향인자)

  • Eoum, Gohye;Cho, Yoonsook;Rhie, Sandy Jeong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.28 no.2
    • /
    • pp.88-94
    • /
    • 2018
  • Background: We strived to evaluate the status of nivolumab use and associated factors on the clinical efficacy of the drug. Methods: The study was retrospectively conducted in patients who had been administered nivolumab at least once at the cancer center of Seoul National University Hospital from June 2015 to April 2017. Data were collected from electronic medical records. A medication-use evaluation was performed based on the American Society of Health-System Pharmacists mediation-use guidelines. Results: Sixty-six of the 74 patients (89.2%) showed indications approved for nivolumab use by the Korean Ministry of Food and Drug Safety (MFDS; n=55) or the US Food and Drug Administration (FDA; n=11). Approximately 73.0% of the patients were administered the approved dose of 3 mg/kg but 25.7% were administered an unapproved fixed dose of 100 mg. The overall response rate was 21.7%, and the response rate of non-small cell lung cancer patients, who accounted for the largest number of indications, was 18.8%. Adverse reactions were found in 90.1% of the patients and were mostly mild (86%). The expression of programmed death-ligand 1 (PD-L1) was analyzed as a factor affecting treatment response (p=0.028, odds ratio [OR]=11.331). Conclusion: PD-L1 expression was found to affect treatment response. However, caution is required while using an unapproved dosage and in the absence of monitoring for effectiveness and safety. Therefore, an effective protocol or instruction manual for the proper use of nivolumab should be considered.

Acceleration Sensor Using Optical Fibers and Film Gratings (광섬유와 필름격자를 이용한 가속도 센서)

  • Lee, Youn-Jea;Jo, Jae-Heung;Kwon, Il-Bum;Seo, Dae-Cheol;Lee, Nam-Kwon
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.175-181
    • /
    • 2008
  • We develop a fiber optic acceleration sensor with LED, PD, POF, and a cantilever beam, having film grating at the edge of the beam. Light is transmitted from LED to PD through the film grating. When the cantilever beam moves by external vibration, output light is modulated as sinusoidal signals. The characteristics of output signals are dominated by the spacing of the film grating and also by the size and the elasticity of the beam. Two output signals, having constant initial phase difference, are obtained by two gratings with 90 degree phase difference. Those two signals are used to determine phase angle, which is proportional to the displacement of the beam. Finally, the acceleration is determined from conversion equation between displacement and acceleration. This sensor is designed for monitoring the vibration of large and complex building in the low frequency range of below 7 Hz, and is particularly suitable to measure acceleration in electromagnetic environments.