• Title/Summary/Keyword: PD classification

Search Result 72, Processing Time 0.026 seconds

Comparison of Classification rate of PD Sources (부분방전원 분류기법의 패턴분류율 비교)

  • Park, Seong-Hee;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.566-567
    • /
    • 2005
  • Until now variable pattern classification methods have been introduced. So, variable methods in PD source classification were applied. NN(neural network) the most used scheme as a PD(partial discharge) source classification. But in recent year another method were developed. These methods is present superior to NN in the field of image and signal process function of classification. In this paper, it is show classification result in PD source using three methods; that is, BP(back-propagation), ANFIS(adaptive neuro-fuzzy inference system), PCA-LDA(principle component analysis-linear discriminant analysis).

  • PDF

Comparison with Finger Print Method and NN as PD Classification (PD 분류에 있어서 핑거프린트법과 신경망의 비교)

  • Park, Sung-Hee;Park, Jae-Yeol;Lee, Kang-Won;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1163-1167
    • /
    • 2003
  • As a PD classification method, statistical distribution parameters have been used during several ten years. And this parameters are recently finger print method, NN(Neural Network) and etc. So in this paper we studied finger print method and NN with BP(Back propagation) learning algorithm using the statistical distribution parameter, and compared with two method as classification method. As a result of comparison, classification of NN is more good result than Finger print method in respect to calculation speed, visible effect and simplicity. So, NN has more advantage as a tool for PD classification.

  • PDF

Comparison of Classification Rate Between BP and ANFIS with FCM Clustering Method on Off-line PD Model of Stator Coil

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa;Seo Jeong-Min;Kim Young-Geun
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.138-142
    • /
    • 2005
  • In this paper, we compared recognition rates between NN(neural networks) and clustering method as a scheme of off-line PD(partial discharge) diagnosis which occurs at the stator coil of traction motor. To acquire PD data, three defective models are made. PD data for classification were acquired from PD detector. And then statistical distributions are calculated to classify model discharge sources. These statistical distributions were applied as input data of two classification tools, BP(Back propagation algorithm) and ANFIS(adaptive network based fuzzy inference system) pre-processed FCM(fuzzy c-means) clustering method. So, classification rate of BP were somewhat higher than ANFIS. But other items of ANFIS were better than BP; learning time, parameter number, simplicity of algorithm.

Analysis and Classification of PD Distribution for VPI Stator coil of Traction motor (진공함침에 따른 견인전동기 고정자 코일의 부분방전 분포 해석 및 분류)

  • Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Joe;Jang, Dong-Uk;Park, Hyun-June
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1982-1984
    • /
    • 2004
  • Stator coil of rotating machinery has shown different characteristics according to impregnated with coil or not. And this is major determinant of equipment's life. In this paper, PD characteristics is studied as a classification scheme between two specimens. Processing of the coil impregnation is very important thing because that influences on thermal and electrical characteristics of the coil. And then PD is occurring at the coil and causing insulation degradation. For processing statistical processing, PD data acquired from PD detector using PDASDA(partial discharge acquisition, storage and display system). And also these statistical distribution and parameter are applied to classify PD sources by neural networks. As a result of, Neural Networks have a good discrimination rate for classification PD sources.

  • PDF

Comparison of Classification Rate for PD Sources using Different Classification Schemes

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.257-262
    • /
    • 2006
  • Insulation failure in an electrical utility depends on the continuous stress imposed upon it. Monitoring of the insulation condition is a significant issue for safe operation of the electrical power system. In this paper, comparison of recognition rate variable classification scheme of PD (partial discharge) sources that occur within an electrical utility are studied. To acquire PD data, five defective models are made, that is, air discharge, void discharge and three types of treeinging discharge. Furthermore, these statistical distributions are applied to classify PD sources as the input data for the classification tools. ANFIS shows the highest rate, the value of which is 99% and PCA-LDA and ANFIS are superior to BP in regards to other matters.

Classification of PD Signals Generated in Solid Dielectrics by Neural Networks (모의결함을 갖는 고체절연재에서 발생하는 부분방전 및 패턴분류)

  • Park, S.H.;Lee, K.W.;Park, J.Y.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1876-1878
    • /
    • 2003
  • The recognition of PD(Partial Discharge) phenomenon is useful for classification of defects. The distribution of stochastic parameters which consisted of those PD pulses data and pulses train can show discriminable characteristics of PD sources. But it is not sufficient to discriminate among to PD sources. In this paper, we suggests that classification method of PD source by NN(Neural Networks) are good tools for differentiate of those. The learning scheme of NN is (Back Propagation learning algorithm(BP).

  • PDF

Application of RBFN Using LPC of PD Pulse Shapes for Discriminating Among Multi PD Sources

  • Lee, Kang-Won;Lim, Kee-Joe;Kang, Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.5
    • /
    • pp.177-181
    • /
    • 2003
  • Partial discharge pulse shapes from variable PD (partial discharge) sources sustain many characteristics such as types of PD. Ultra high frequency antennas have wide bandwidth from 30KHz to 2㎓. Therefore, signals taken from a UHF antenna have important attributes (rising time, falling time, shape factor, etc.) for electromagnetic sources, such as PD sources. We investigated PD pulse shapes from several PD sources using a UHF antenna and the results were used for classification of PD sources. Features for discrimination are extracted from frequency distribution and LPC (Linear Prediction Coefficient) of time signal. RBFN are used for investigating the possibility of classification of multi-PD sources.

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

Comparison of BP and SOM as a Classification of PD Source (부분방전원의 분류에 있어서 BP와 SOM의 비교)

  • 박성희;강성화;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1006-1012
    • /
    • 2004
  • In this paper, neural networks is studied to apply as a PD source classification in XLPE power cable specimen. Two learning schemes are used to classification; BP(Back propagation algorithm), SOM(self organized map - kohonen network). As a PD source, using treeing discharge sources in the specimen, three defected models are made. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different models of discharge sources. And a]so these distribution characteristics are applied to classify PD sources by two scheme of the neural networks. In conclusion, recognition efficiency of BP is superior to SOM.

Properties and classification of air discharge by Kohonen network (기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF