• Title/Summary/Keyword: PD(Partial discharge) sensor

Search Result 136, Processing Time 0.021 seconds

Om-site Application of External UHF PD Sensor for the Identification of Partial Discharge Location (UHF대역 PD신호검출에 의한 GIS 결함위치표정의 현장적용 연구)

  • Lee, Chang-R.;Hong, C.Y.;Yoon, C.Y.;Yoon, J.H.;Nam, G.C.;Lee, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1766-1768
    • /
    • 2004
  • This paper describes the prediction of location of PD signals in GIS using the difference in the measured time between first and second wave arrival by the external-type PD sensors. It is well accepted that the electromagnetic wave in GIS propagates at the velocity of $3{\times}10^8$m/s. Consequently, we could identify the location of PD with high accuracy. The experience at the fields and the problems for the judgment are also discussed in detail.

  • PDF

Discrimination of Insulation Defects in a Gas Insulated Switchgear (GIS) by use of a Neural Network Based on a Chaos Analysis of Partial Discharge (CAPD)

  • Jung, Seoung-Yong;Ryu, Cheol-Hwi;Lim, Yun-Sok;Lee, Ja-Ho;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.118-122
    • /
    • 2007
  • In this work, experimental investigation is carried out in order to design and fabricate the UHF sensor that is able to detect the partial discharges produced from 10 artificial defects introduced into the real scale 70kV GIS mock-up under high voltage within a well shielded room. As well, in order to verify the on-site applicability of our method, the newly proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis for identifying the nature of 10 artificial defects under investigation. The PD pattern recognition of each defect has been fulfilled by applying our ANN software. The result indicates that the recognition rate reaches up to 80% by the newly proposed method while the traditional PRPD analysis method allows us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

A possible application of the nonuniform electric field measurement using Pockets effect (포켈스 효과를 이용한 불평등 전계 측정)

  • Kang, W.J.;Lim, Y.S.;Choi, J.O.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF

Detection of Partial Discharge in $SF_6$ Gas-insulated Switchgear Using External UHF PD sensors (가스절연기기에서 외장형 PD 센서를 이용한 부분방전 검출)

  • Lee, Chang-R.;Hong, C.Y.;Choi, B.H.;Yoon, J.H.;Nam, G.C.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.125-127
    • /
    • 2004
  • We have developed the external-type PD sensors for detecting of the ultra high frequency (UHF) signals in various type of GIS. Sufficiently high sensitivity and accuracy for practical use were achieved for the PD sensor. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor (포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구)

  • Ma, Ji-Hoon;Kang, Won-Jong;Lim, Yun-Sok;Choi, Jae-Ok;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

Analysis of Partial Discharge Signal Propagation Characteristics in GIS using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Kim Jae-Chul;Lee Do-Hoon;Song Seung-Yeop;Kim Kwang-Whoa
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.624-629
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate higher than cut-off frequency. In this paper, the cut-off frequency of 362[kV] GIS for each modes is computed and the electromagnetic field of each propagation modes is simulated by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes was determinated by simulation results and was discussed optimal position of UHF sensor from this results.

Filter Design for Detecting High-Frequency Partial Discharge (고주파 부분방전 시험을 위한 필터 설계)

  • Ahn, Jong-Hyun;Yun, Ju-Ho;Choi, Yong-Sung;Choi, Chung-Seog;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.68-71
    • /
    • 2007
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke probe and oscilloscope (TDS-3054, Tektronix).

  • PDF

Development of UHF Partial Discharge Sensor for Intelligent distribution Facilities (지능형 배전기기를 위한 UHF 부분방전 센서 개발)

  • Cho, Young-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Gun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.161-162
    • /
    • 2007
  • This paper is analyzed the internal type UHF sensors that be able to monitor the condition of the distribution facilities and the location selecting of that sensors. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

Identification of partial discharge sources in GIS using AEsensor (초음파센서를 이용한 GIS내 부분방전원의 식별)

  • Lee, Y.H.;Lee, K.W.;Lee, Y.H.;Shin, Y.S.;Seo, J.M.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.200-202
    • /
    • 2002
  • The use of ultrasound is proposed as the most economic and practical nondestructive test method for the detectin of electrical degradation in insulating materials. This paper has studied identification and characterization of partial discharge signals according to defects in GIS using AE(acoustic emission)sensor. Analysis of PD signals use $\psi-v-n$, skewness and kurtosis.

  • PDF

Performance Verification of the Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method (UHF 부분방전 진단법에 의한 가스절연 개폐장치의 성능검증)

  • Kim, J.B.;Jung, J.R.;Kim, M.S.;Song, W.P.;Kim, M.H.;Ko, H.S.;Choi, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.132-135
    • /
    • 2004
  • In generally, compared with VHF band, electromagnetic waves of UHF band have a low influence for external noise. We can detect the real abnormality with several pC in GIS using UHF method. Recently, it has applied to use the external UHF sensor attached on spacer to GIS of existing substation. In this paper, we firstly described the technique of the partial discharge measurement using frequency analysis and phase analysis in UHF band. Secondly, we presented the results of sensitivity, the relationship of dBm-pC and diagnosis of the reason of PD source by phase analysis. And then, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. rge diagnosis of GIS.

  • PDF