• 제목/요약/키워드: PCS Systems

검색결과 317건 처리시간 0.032초

DVB-H/GSM/DCS/PCS band internal antenna for mobile handheld communication systems

  • Jung, Byung-Woon
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.169-171
    • /
    • 2008
  • An internal antenna for small mobile systems is proposed to support the DVB-H system. It consists of two antenna elements, which are a folded planar monopole for DVB-H and PIFA for GSM/DCS/PCS, and a meander line and RF cable are used to increase the ground plane. Experimental results of the antenna are presented.

Client/Server 기반하에서 POP 시스템의 구축과 적용에 관한 연구 (A Study on The Implementation and Application of POP Systems Based on The Client/Server Architecture)

  • 문혁동;송수정;정영득;강경식
    • 산업경영시스템학회지
    • /
    • 제20권42호
    • /
    • pp.181-192
    • /
    • 1997
  • Production Control System(PCS) can be used in controlling productivity effectively. The system provides the workers and managers and with the management information. The objective of PCS is to improve and optimize productivity in practice. To achieve this goal, PCS must be applied in many Industries. Information System at Point Of Production(POP) is the system that helps worker and managers to analyze the various information at production line in practice. In this paper, we propose a new developed Client/Server POP System using "Bar Code." The new system can be integrated and communicated with CIM. The developed system can be used by engineers, managers, to improve productivity in practice. practice.

  • PDF

계통연계형 태양광발전 인버터에 사용된 AFD기법의 다양한 부하에 따른 단독운전 불검출영역에 대한 고찰 (A Study of Non-Detection Zone using AFD Method applied to Grid-Connected Photovoltaic Inverter for a variety of Loads)

  • 고문주;최익;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.91-98
    • /
    • 2006
  • Islanding phenomenon of utility-connected photovoltaic power conditioning systems(PV PCS) can cause a variety of problems and must be prevented. If the real and reactive power supplied by PV PCS are closely matched to those of load, islanding detection by passive methods becomes difficult. The active frequency drift(AFD) method, called the frequency bias method, enables islanding detection by forcing the frequency of the voltage in the islanding to drift up or down. In this paper, non-detection zone(NDZ) of AFD is analyzed for the islanding detection method of utility-connected PV PCS by the simulation software tool PSIM.

The Research of the UWB Interference Effects on the Mobile Communication System

  • Song, Hong-Jong;Cha, Jae-Sang;Park, Goo-Man
    • 한국통신학회논문지
    • /
    • 제35권11A호
    • /
    • pp.1085-1090
    • /
    • 2010
  • Ultra wideband (UWB) technologies have been developed to exploit a new spectrum resource in substances and to realize ultra-high-speed communication, high precision geolocation, and other applications. The energy of UWB signal is extremely spread from near DC to a few GHz. This means that the interference between conventional narrowband systems and UWB systems is inevitable. However, the interference effects had not previously been studied from UWB wireless systems to conventional mobile wireless systems sharing the frequency bands such as Cellular CDMA and Korean PCS. This paper experimentally evaluates the interference from two kinds of UWB sources, namely a direct-sequence spread-spectrum UWB source and an impulse radio UWB source, to a Cellular CDMA and K-PCS digital transmission system. The average frame error rate degradation of each system arc presented. From these experimental results, we show that in all practical cases UWB system can coexist with Cellular CDMA and K-PCS terminal without causing any dangerous interference.

FTA를 적용한 태양광 발전 및 ESS 연계형 PCS의 안전성 평가 (Safety Assessment for PCS of Photovoltaic and Energy Storage System Applying FTA)

  • 김두현;김성철;김의식;남기공;정천기
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.14-20
    • /
    • 2019
  • This paper presents a safety assessment based approach for the safe operation for PCS(Power Conditioning System) of photovoltaic and energy storage systems, applying FTA. The approach established top events as power outage and a failure likely to cause the largest damage among the potential risks of PCS. Then the Minimal Cut Set (MCS) and the importance of basic events were analyzed for implementing risk assessment. To cope with the objects, the components and their functions of PCS were categorized. To calculate the MCS frequency based on IEEE J Photovolt 2013, IEEE Std. 493-2007 and RAC (EPRD, NPRD), the failure rate and failure mode were produced regarding the basic events. In order to analyze the top event of failure and power outage, it was assumed that failures occurred in DC breaker, AC breaker, SMPS, DC filter, Inverter, CT, PT, DSP board, HMI, AC reactor, MC and EMI filter and Fault Tree was drawn. It is expected that the MCS and the importance of basic event resulting from this study will help find and remove the causes of failure and power outage in PCS for efficient safety management.

태양광발전용 3kW급 PCS개발 (Development of Power Conditioning System for Photovoltaic Power Generation Systems)

  • 민병권;류승표;전세봉;이봉우;김남해
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.123-126
    • /
    • 2005
  • Recently, because of the depletion of fossil fuels and the environmental pollution by using fossil fuels and harmfulness of atomic power plants. the interests concerning new and renewable energy resources are rising increasingly. And of all new and renewable energy sources the PV generation systems are recognized as the most useful and desirable renewable energy source in allowance for installation conditions. In this development, the 3kWp photovoltaic power generation system is realized to verify the performance of the 3kWp PCS developed by Hyundai Heavy Industries Co. (HHI). The photovoltaic array used in this system is composed of 60 modules of 50Wp capacity. The developed system is tested as procedures and items of test regulation recognized by governmen and the experimental results show the excellent electrical characteristics. Now, the 3kWp PCS developed is installed in the PV model house built in HHI plant and is being tested for practical use commercialization.

  • PDF

고조파와 무효전력 보상기능을 가지는 Smart PCS의 새로운 제어 알고리즘 (Novel control algorithm for smart PCS with harmonics and reactive power compensation)

  • 서효룡;장성재;박상수;김상용;김경훈;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1053_1054
    • /
    • 2009
  • A significant number of renewable energy systems have been connected to the grids as supplement power source. The renewable energy systems require control algorithm to maintain the power-supply reliability and quality. This paper proposes a novel control algorithm for smart Power Conditioning System (PCS) with harmonics and reactive power compensation. The smart PCS is used to feed Photovoltaic (PV) power to utility and compensate harmonics and reactive power at the same time. The experimentation is carried out on the proposed grid-connected PV generation system, and controlled by digital signal processor. The grid-connected PV generation system injects PV energy into the grid and performs as Active Filter (AF) and Static Synchronous Compensator (STATCOM) without additional devices. The experiment results show that the proposed control algorithm is effective for smart PCS with harmonics and reactive power compensation.

  • PDF