• Title/Summary/Keyword: PCS Systems

Search Result 318, Processing Time 0.028 seconds

Detection System Model of Zombie PC using Live Forensics Techniques (활성 포렌식 기술을 이용한 좀비 PC 탐지시스템 모델)

  • Hong, Jun-Suk;Park, Neo;Park, Won-Hyung
    • The Journal of Society for e-Business Studies
    • /
    • v.17 no.3
    • /
    • pp.117-128
    • /
    • 2012
  • There was a large scale of DDoS(Distributed Denial of Service) attacks mostly targeted at Korean government web sites and cooperations's on March 4, 2010(3.4 DDoS attack) after 7.7 DDoS on July 7, 2009. In these days, anyone can create zombie PCs to attack someone's website with malware development toolkits and farther more improve their knowledge of hacking skills as well as toolkits because it has become easier to obtain these toolkits on line, For that trend, it has been difficult for computer security specialists to counteract DDoS attacks. In this paper, we will introduce an essential control list to prevent malware infection with live forensics techniques after analysis of monitoring network systems and PCs. Hopefully our suggestion of how to coordinate a security monitoring system in this paper will give a good guideline for cooperations who try to build their new systems or to secure their existing systems.

Design of a Photovoltaic PCS with Compensation Control of Reactive Power and Unbalance Current in Three-phase systems (3상 시스템의 무효전력, 불평형 전류 보상 기능을 갖는 태양광 전력변환장치 설계)

  • Park, Sang-Min;Kim, Chang-Soon;Le, Dinh Vuong;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.3
    • /
    • pp.29-33
    • /
    • 2016
  • Development of the distributed energy resources such as photovoltaic, wind, and fuel cell has increased rapidly due to the rising demand for clean energy utilization. On the other hand, the distribution system became complex and has problems such as degradation of power factor and current unbalance caused by power converters, reactive power and unbalanced loads. To solve these problems, this paper proposes a 3-phase 4-leg type power conditioning system with compensation control algorithm for the reactive power and unbalance current in distribution system using photovoltaic resource. It is simulated in PSCAD/EMTDC and the effectiveness is confirmed.

Differential Power Processing System for the Capacitor Voltage Balancing of Cost-effective Photovoltaic Multi-level Inverters

  • Jeon, Young-Tae;Kim, Kyoung-Tak;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1037-1047
    • /
    • 2017
  • The Differential Power Processing (DPP) converter is a promising multi-module photovoltaic inverter architecture recently proposed for photovoltaic systems. In this paper, a DPP converter architecture, in which each PV-panel has its own DPP converter in shunt, performs distributed maximum power point tracking (DMPPT) control. It maintains a high energy conversion efficiency, even under partial shading conditions. The system architecture only deals with the power differences among the PV panels, which reduces the power capacity of the converters. Therefore, the DPP systems can easily overcome the conventional disadvantages of PCS such as centralized, string, and module integrated converter (MIC) topologies. Among the various types of the DPP systems, the feed-forward method has been selected for both its voltage balancing and power transfer to a modified H-bridge inverter that needs charge balancing of the input capacitors. The modified H-bridge multi-level inverter had some advantages such as a low part count and cost competitiveness when compared to conventional multi-level inverters. Therefore, it is frequently used in photovoltaic (PV) power conditioning system (PCS). However, its simplified switching network draws input current asymmetrically. Therefore, input capacitors in series suffer from a problem due to a charge imbalance. This paper validates the operating principle and feasibility of the proposed topology through the simulation and experimental results. They show that the input-capacitor voltages maintain the voltage balance with the PV MPPT control operating with a 140-W hardware prototype.

Improved RRS Logical Architecture using Genetic Algorithm (유전자 알고리즘 적용을 통한 향상된 RRS Logic 개발)

  • Shim, Hyo Sub;Jung, Jae Chun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.2
    • /
    • pp.115-125
    • /
    • 2016
  • An improved RRS (Reactor Regulating System) logic is implemented in this work using systems engineering approach along with GA (Genetic Algorithm) deemed as providing an optimal solution to a given system. The current system works desirably and has been contributed to the safe and stable NPP operation. However, during the ascent and decent section of the reactor power, the RRS output reveals a relatively high steady state error and the output also carries a considerable level of overshoot. In an attempt to consolidate conservatism and minimize the error, this research proposes applying genetic algorithm to RRS and suggests reconfiguring the system. Prior to the use of GA, reverse-engineering is implemented to build a Simulink-based RRS model and re-engineering is followed to apply the GA and to produce a newly-configured RRS generating an output that has a reduced steady state error and diminished overshoot level.

Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant (대규모 태양광 발전설비를 위한 전력변환기 개발)

  • Kang, Ho-Hyun;Jung, Hong-Ju;Kim, Wang-Mun;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

Design and Implementation of a PC/Ethernet-based Communication Protocol for Control Systems (PC/Ethernet 기반의 제어용 통신 프로토콜 설계ㆍ구현)

  • 장태인;곽귀일;변승현;조지용
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1129-1132
    • /
    • 1999
  • This paper deals with the design and implementation of an Ethernet-based communication protocol to be used in PC-based I/O interface systems. Recently, the performance of PC systems is being highly improved and Ethernet is used as the stable communication network over the world. We develop a new protocol driver with the capability of accessing Ethernet directly using NDIS(Network Driver Interface Specification), the network interface standard of Windows O.S. in PC, and install it at the application layer of the protocol structure. Its major roles are the supplement of CSMA/CD algorithm, the effective use of the long data frame of Ethernet, and the real-time transmission of data frames. This paper represents the possibility of the real-time control network and systems based on PCs and Ethernet.

  • PDF

A Study on Development of PC-based Wireless Data Access System (PC 기반 양방향 무선데이터 시스템 개발에 관한 연구)

  • Joo, Jong-Hyuk
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.3
    • /
    • pp.115-120
    • /
    • 2005
  • In this paper, we propose a personal-computer-based wireless data access system, which use DS/SS(Direct Sequence Spread Spectrum) method and the ISM band of 2.44GHz radio frequency. By applying hi-directional transmission between wireless handy terminals and PCs or servers, it can be easily connected with any kinds of database systems such as Oracle, MS-SQL and MS-ACCESS. Therefore, it could be economically adopted as peripheral equipments for ERP or SCM systems.

An Efficient Location Cache Scheme for 3-level Database Architecture in PCS Networks (PCS 네트워크에서 3-레벨 데이터베이스 구조를 위한 효과적인 위치 캐시 기법)

  • Han, Youn-Hee;Song, Ui-Sung;Hwang, Chong-Sun;Jeong, Young-Sik
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.3
    • /
    • pp.253-264
    • /
    • 2002
  • Recently, hierarchical architectures of databases for location management have been proposed in order to accommodate the increase in user population in future personal communication systems. In particular, a 3-level hierarchical database architecture is compatible with current cellular mobile systems. In the architecture, a newly developed additional databases, regional location database(RLR), are positioned between HLR and VLRs. We propose an efficient cache scheme, called the Double T-thresholds Location Cache Scheme. The cache scheme extends the existing T-threshold location cache scheme which is competent only under 2-level architecture of location databases currently adopted by IS-41 and GSM. The idea behind our scheme is to use two pieces of cache information, VLR and RLR serving called portables. The two pieces are required in order to exploit root only locality of registration area(RA) but also locality of regional registration area(RRA) which is the wide area covered by RLR. We also use two threshold values in order to determine whether the two pieces are obsolete. In order to model the RRA residence time, the branching Eralng-$\infty$ distribution is introduced. Our minute cost analysis shows that the double T-threshold location cache scheme yields significant reduction of network and database costs for molt patterns of portables.

An Unequal Protection FEC Scheme for Video over Optical Access Networks

  • Cao, Yingying;Chen, Xue;Wang, Liqian;Li, Xicong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.6
    • /
    • pp.1463-1479
    • /
    • 2013
  • In this paper, we propose an unequal protection physical coding sub-layer (PCS) forward error correction (FEC) scheme for efficient and high-quality transmission of video data over optical access networks. Through identifying and resolving the unequal importance of different video frames and passing this importance information from MAC-layer to PCS, FEC scheme of PCS can be adaptive to application-layer data. Meanwhile, we jointly consider the different channel situations of optical network unit (ONU) and improve the efficiency of FEC redundancy by channel adaptation. We develop a theoretical algorithm and a hardware method to achieve efficient FEC assignment for the proposed unequal protection scheme. The theoretical FEC assignment algorithm is to obtain the optimal FEC redundancy allocation vector that results in the optimum performance index, namely frame error rate, based on the identified differential importance and channel situations. The hardware method aims at providing a realistic technical path with negligible hardware cost increment compared with the traditional FEC scheme. From the simulation results, the proposed Channel and Application-layer data Adaptation Unequal Protection (CAAUP) FEC scheme along with the FEC ratio assignment algorithm and the hardware method illustrates the ability of efficient and high-quality transmission of video data against the random errors in the channel of optical access networks.

A Study on Anti-Islanding Evaluation of Grid-Connected Power Conditioning System for Fuel Cell System in Parallel Operation (병렬 연결된 계통연계형 연료전지 전력변환장치의 단독운전방지 평가 연구)

  • Choi, Young-Joo;Oh, Gun-Woo;Kim, Min-Woo;Lee, Seung-Kuk;Park, Ga-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.124-132
    • /
    • 2018
  • The supply of renewable energy has become more vigorous due to Paris Agreement. In Korea, supply policies of renewable energy is being promoted with priority given to public buildings, so, the supply of fuel cell system that are relatively easy to install in buildings is expected to expand, so it is important that study on anti-islanding evaluation of grid-connected power conditioning system(PCS) for fuel cell. In this study, we consider that KGS AB934 PC53 in domestic certification standard of PCS for fuel cell correspond with abroad standard and analyze anti-islanding evaluation that important safety performance when connected grid. Additionally, we constructed a prototype for anti-islanding evaluation of PCS for fuel cell connected in parallel and carried out the demonstration evaluation, so, we have conducted ways that ensure safety performance in accordance with the circumstances where several fuel cell systems are installed.