There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.
This study was performed to evaluate the clinical applicability of the reverse transcription polymerase chain reaction (RT-PCR ) kit of HCV-RNA using biotinylated and radioiodinated primers. Study subjects were 118 patients with positive anti-HCV. HCV-RNA in patient's serum was extracted by guanidium thiocyanate method. After first amplification, the product was reamplified by primers labelled with biotin and I-125. The final amplification product was defected by counting the radioactivity after incubation in avidin coated tubes. In 51 samples, the test was repeated for evaluation of reproducibility. This new method was also compared with conventional RT-PCR methods in 34 samples from patients with chronic liver disease. The results were as follows ; 1) HCV-RNA was positive in 85(97%)of 88 patients with chronic liver disease, and in 23 (73%) of 30 patients with normal liver function. 2) In comparison with conventional method, HCV-RNA was detected in 32(94%) of 34 patients with new method, whereas in 27(79%) of the same group with conventional method. 3) Repeated test with new method in 52 samples demonstrated 82% of concordant result. In conclusion, new method with biotinylated and radioiodinated primers was more sensitive than conventional method. However, great care must be taken for quality control because there were considerable interassay variation and possiblity of false positivity and false negativity.
This study was carried out to discriminate Hanwoo from the milking and hybrid cattle by detection of MC1R gene related to bovine hair color. One hundred sixty six samples were collected from the abattoir (n = 106) and local market (n = 60). The beef from abattoir were originated from Hanwoo (n=27), Holstein (n=29), Hybrid (n=45) and imported cattle (n=5), respectively. The beef from market consisted of Hanwoo (n=36), Holstein (n=7) and imported ones (n=17). Commercialized screening kit (Kogenebiotec, Korea) was used for MC1R gene analysis. As a result, Hanwoo was discriminated from Holstein. However, 9 of 45 hybrid and 11 of 22 imported beef samples were indistinguishable from Hanwoo. It could be explained by second generation of crossing of Hanwoo with Holstein or the cattle with silver or yellow hair. This results suggest that additional tests as well as MC1R gene detection be needed to confirm Hanwoo beef among cattle beef.
Ahn, Jaehyun;Kwon, Youngwoo;Lee, Jeong-Su;Choi, Weon Sang
Journal of Food Hygiene and Safety
/
v.30
no.2
/
pp.150-158
/
2015
This article reports the development of an effective test procedure for detection of norovirus (NoV) in foods of diverse matrices. In this study, target foods included fermented milk, soybean paste, powders made from uncooked grains and vegetables, sesame leaves preserved in soy sauce, pickled mooli, and mooli. Viral recovery varied depending on the food matrices or elution buffers tested. Buffers were compared to determine effective elution buffers from artificially virus-contaminated foods. The conventional test procedure for concentrating viruses from food (elution-polyethylene glycol(PEG) precipitation-chloroform-PEG precipitation) was modified to save time by eliminating one PEG precipitation step. The modified procedure (elution-chloroform-PEG precipitation) was able to concentrate viruses more effectively than the conventional procedure. It also removed RT-PCR inhibitors effectively. The modified procedure was applied to target food for genogroup II NoV detection. NoV RNA was detected at the initial inoculum levels 3.125-12.5 RT-PCR units per 10-25 g tested food. The use of this newly established procedure should facilitate detection of low levels of norovirus in diverse foods.
This study was carried out to investigate the distribution and characteristics of Listeria monocytogenes isolated from frozen Mandoo and pizza in 1998. A total 72 samples were examined and USDA, FDA and modified cold enrichment methods were used for the detection of Listeria spp. Overall prevalence of L. monocytogenes in frozen foods was 9.7% and L. monocytogenes was isolated from 11.1% of frozen Mandoo and 5.6% of frozen pizza. The highest detection rate of Listeria spp. in frozen Mandoo was found at USDA method and the serotype of L. monocytogenes isolates was 4. Isolated L. monocytogenes was confirmed by PCR method with Hly 1 and 2 as primers. It would be necessary to develop more rapid and specific method to isolate and confirm L. monocytogenes from foods because USDA and PCR methods used in this study took 3-4 days. D value of L. monocytogenes isolate in tryptic soy broth was 49.2 sec at $60^{\circ}C$ and 8.8 sec $at\;65^{\circ}C$, and D value of L. monocytogenes in foods with high distribution rate of Listeria spp. would be necessary to evaluate for the safe use of frozen foods.
This study was to review the classification, detection and control of bacteriophage in fermented dairy products. Bacteriophage has lytic and/or lysogenic life cycles. Epidemiologically speaking, detected major phages are c2, 936 and p335. Among them p335 has been the largest concern in dairy industry. Traditionally, various analytical technologies, such as spot, starter activity, indicator test, ATP measurement and conductimetric analysis, have been used for the phage detection. In recent years, advanced methods such as flow cytometric method, petrifilm, enzyme linked immunosorbent assay (ELISA) and multiflex PCR diagnostic kit have been deveoloped. The phage contamination has been controlled by using heat, high-pressure treatment, and the combinations of heat and pressure, and/or chemical. Also some starter cultures with phage-resistant character have been developed to minimize the concentration of phages in dairy product. Bacteriophage inhibition media such as calcium medium was also mentioned. To prevent the contamination of bacteriophage in dairy industry, further researches on the detection and control of phage, and phage resistant starters are necessary in the future.
An immunochromatography (ICG) strip test based on a monoclonal antibody for the rapid detection of L. monocytogenes in meat and processed-meat samples was developed in this study. A monoclonal antibody (MAb) specific to L. monocytogenes was produced from cloned hybridoma cells (FKLM-3B12-37) and used to develop an ICG strip test. The antibody showed a stronger binding to L. monocytogenes than other Listeria species, and a weak cross-reaction to S. aureus based on an ELISA. The detection limit of the ICG strip test was $10^5\;cell/ml$. In total, 116 meat and processed-meat samples were collected and analyzed using both the ICG strip test and a PCR. The ICG strip test and PCR indicated L. monocytogenes contamination in 34 and 27 meat samples, respectively. The 7 meat samples not identified as L. monocytogenes positive by the PCR were also tested using an API kit and found to be contaminated by Listeria species. In conclusion, the ICG strip test results agreed well with those obtained using the PCR and API kit. Thus, the developed ICG has potential use as a primary screening tool for L. monocytogenes in various foods and agricultural products, generating results within 20 min without complicated steps.
Tuberculosis caused by Mycobacterium tuberculosis (MTB) still remains to be the most dreadful infectious disease affecting almost every country. In the present study, we developed a simple and rapid but accurate and sensitive assay method for detecting MTB using microplate hybridization assay. For this, a selective region of the rpoB gene was used to design PCR primers, and MTB and Mycobacterium genus-specific probe molecules. The specificity of the assay was confirmed using fifteen different mycobacterial reference strains and twelve different non-mycobacterial reference strains, and the sensitivity was determined to be 100 fg using genomic DNA of MTB reference strain, H37Rv. Subsequently, a total of 62 sputum samples with diverse smear scores and culture positive results were used to evaluate the kit performance. In brief, the specificity and the sensitivity of the assay were 100% and 98.4%, respectively.
Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
The Korean Journal of Nuclear Medicine Technology
/
v.23
no.1
/
pp.35-39
/
2019
Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).
Purpose: Cytolethal distending toxin (CDT) considered as a key factor of localized aggressive periodontitis, endocarditis, meningitis, and osteomyelitis is composed of five open reading frames (ORFs). Among of them, the individual role of CdtA and CdtC is not clear; several reports presents that CDT is an AB2 toxin and they enters the host cell via clathrin-coated pits or through the interaction with GM3 ganglioside. So, CdtA, CdtC, or both seem to be required for the delivery of the CdtB protein into the host cell. Moreover, recombinant CDT was suggested as good vaccine material and antibody against CDT can be used for neutralization or for a detection kit. Materials and Methods: We constructed the pET28a-cdtC plasmid from Aggregatibacter actinomycetemcomitans Y4 by genomic DNA PCR and expressed in BL21 (DE3) Escherichia coli system. We obtained the antibody against the recombinant CdtC in mice system. Using the anti-CdtC antibody, we test the native CdtC detection by ELISA and Western Blotting and confirm the expression time of native CdtC protein during the growth phase of A. actinomycetemcomitans. Results: In this study we reconstructed CdtC subunit of A. actinomycetemcomitans Y4 and generated the anti CdtC antibody against recombinant CdtC subunit expressed in E. coli system. Our anti CdtC antibody can be interacting with recombinant CdtC and native CDT in ELISA and Western system. Also, CDT holotoxin existed at 24h but not at 48h meaning that CDT holotoxin was assembled at specific time during the bacterial growth. Conclusion: In conclusion, we thought that our anti CdtC antibody could be used mucosal adjuvant or detection kit development, because it could interact with native CDT holotoxin.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.