• Title/Summary/Keyword: PCPS

Search Result 24, Processing Time 0.027 seconds

Study on the high precision output of 50kV high-voltage inverter (50kV 고전압 인버터 고정밀 출력설계에 관한 연구)

  • Son, Y.G.;Suh, J.H.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2199-2201
    • /
    • 2005
  • High voltage power supply with pulse load($4.5{\mu}s$ and PRF 60Hz) condition is investigated which is of interest for applications like Klystron modulator power supplies with output voltage of 50kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation(<0.01%) and high efficiency(> 85%). The solution to this problem as a single stage converter is very difficult. The final output voltage is obtained as sum of the output of SCPS & PCPS. The combination of the two stages can satisfy the pulse load specifications. The analysis of the voltage and power division between SCPS & PCPS has been done for the proposed topology. It has studied under various operating conditions of line and load. Simulation results are validated by experimental results.

  • PDF

Respiratory Support by Performing Percutaneous Cardiopulmonary Support (PCPS) for Tracheal Resection and Reconstruction in Patients with Severe Distal Tracheal Stenosis (고도의 원위부 기관협착 환자에서 경피적 심폐보조장치를 이용한 호흡보조 하에 시행한 기관절제 및 단단 문합술)

  • Cho, Sang-Ho;Park, In-Kyu;Lee, Chang-Young;Bae, Mi-Kyung;Chung, Kyung-Young
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.259-262
    • /
    • 2009
  • Surgery on the distal trachea or the carina presents special problems for maintaining the airway and systemic oxygenation. Cardiopulmonary bypass is an alternative method for respiratory support for the patients with these conditions. Percutaneous cardiopulmonary support (PCPS) applied under local anesthesia has recently been used for respiratory support in tracheal surgery and the outcome is satisfactory. We encountered a patient who had severe distal tracheal stenosis after prolonged intubation. We had a gratifying result with performing tracheal resection and repair under the support of PCPS.

Characterization of the Gene for the Light-Harvesting Peridinin-Chlorophyll-Protein of Alexandrium tamarense

  • LEE SOON-YOUL;KANG SUNG-HO;JIN EONSEON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.5
    • /
    • pp.1094-1099
    • /
    • 2005
  • Photosynthetic dinoflagellates contain a water-soluble, light-harvesting antenna called the peridinin-chlorophyll-protein (PCP) complex, which has an apoprotein with no sequence similarity to other known proteins. There are two forms of PCP apoproteins; the 15-kDa short form and the 32- to 35­kDa long form. The present study describes the PCP protein and its cDNA from Alexandrium tamarense. A cDNA library was constructed from mRNA isolated from A. tamarense. The complete PCP cDNA was generated by reverse-transcription coupled to polymerase chain reaction (RT-PCR), together with rapid-amplification of cDNA ends (RACE). The A. tamarense PCP cDNA encoded a 55-amino acid signal peptide and a 313-amino acid mature protein with a calculated mass of 32 kDa, which corresponded to that of the long form of PCP. Phylogenetic analysis indicated that the sequence of A. tamarense PCP did not cluster with the short-form PCPs, to which it was only about $55\%$ identical, but which were $79-83\%$ identical to other long-form PCPs. The deduced amino acid sequence of A. tamarense PCP contains an internal duplication, which suggests the possibility that long-form PCPs arose by gene duplication or by the fusion of genes encoding the short form. The abundance of PCP mRNA changed substantially in response to different light conditions, indicating the possible existence of a photo-acclimation response in A. tamarense.

A Study on the Characteristics of Surface Flashover for PCPS (PCPS용 반도체 연면방전 특성 연구)

  • 김정달;정장근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-95
    • /
    • 1999
  • A primary limitation of the awlication of New class of solid state high power, high speed electronic device, narrely, the Photo-Conductive Power Switch(PCPS) is that the switches flashover at the surlace under average awlied fields much less than the bulk breakdown field of the semiconductor in most cases. The only way overcome those problffi1 and has a workable compact solid state switch is to passivate the surlace by a solid state dielectric material. In this experirrentation, The voltage withstands of Silicon is to be severely degraded when operated in vacuum(10[kV/cm]) and the perlormance is improved when operated in air(30[kV/cm[), in SF6(80~100[kV/cm]). After the passivation, the device had a breakdown field in vacuum and air at a field as high as the unpassivated device in SF6. A experirrent results show passivated devices have excellent breakdown field. In this paper, We improved the main properties and mechanism of the silicon breakdown before and after passivation under high field. field.

  • PDF

A Study about the Factors Affecting Hearing loss in Adolescent's use of Personal Cassette Players(PCPs) (휴대용 카세트 사용 청소년의 청력관련 요인)

  • Lim, Kyung-Hee;Park, Kyung-Min;Park, Myung-Hwa
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.125-141
    • /
    • 2001
  • The purpose of this study was to investigate the factors affecting hearing loss in adolescent's use of PCPs, and to give the basic data for adolescent's hearing conservation program development and prevention education against their hearing loss. This study was a descriptive research about three factors affecting hearing loss; the knowledge and attitude about noise, the perception of hearing loss and the hearing threshold. The subjects of this study were 383 students in two general high schools and two vocational high schools in Teagu. They have been using PCPs but with no current or past ear disease. This study was carried out from Sep. 1. 2000 to Oct. 24, 2000. The instrument used for the knowledge and attitude about noise was a questionnaire developed by Rhee. Kyung Yong and Yi. Kwan Hyung(1996). The instrument used for the perception of hearing loss was a Smith Hearing Screening Questionnaire. A Belton Model 112 Audiometer. air-conduction hearing test instrument. was used for the hearing threshold. Data was analysed by a SPSS/Win 10.0 program with frequency. percentage, t-test. ANOVA and pearson correlation. The results of this study were as follows; 1. The average of concern about hearing scored the highest $3.66{\pm}0.70$. The average of perceived susceptibility scored $2.64{\pm}0.85$ and the average of knowledge about noise scored $2.13{\pm}0.56$. The average of total knowledge and attitude about noise scored $2.82{\pm}0.46$. The average of discomfort of hearing loss($2.51{\pm}0.81$) scored higher than that fear of hearing loss($1.35{\pm}0.53$). The average of total perception of hearing loss scored $1.93{\pm}0.59$. The hearing threshold of the subjects scored the highest at 500Hz(Lt. $23.21{\pm}6.62$, Rt. $23.39{\pm}7.02$) and scored higher in order of 1000Hz, 2000Hz, 4000Hz and 8000Hz. 2. The knowledge and attitude about noise and the perception of hearing loss were both affected only by one important characteristic, which was general and vocational high schools. The knowledge and attitude about noise raked (t=5.258, p=0.000), and perception of hearing loss raked(t=2.241. p=0.026). However. several other important characteristics also impacted significantly on the knowledge and attitudes about noise. They included grade (t = 1. 987. p=0.048), father's education(F=2.745. p=0.043), marks(F=3.157, p=0.044), drinking(t=2.307, p=0.022) and smoking(t=2.587, p=0.010). The left hearing threshold differed significantly by sex at 1000Hz(t=5.175, p<0.001) and 8000Hz (t=3.334, p<0.01). According to general and vocational high schools (p<0.001), at 500Hz (t=-5.056), 1000Hz (t=-5.253), 2000Hz (t=-4.905), 4000Hz (t=-4.704) and 8000Hz (t=-5.204) significant differences were also shown. Marks were significant at 1000Hz (F=3.824, p<0.05) and drinking was found to be significant at 500Hz(t=2.203, p<0.05). The right hearing threshold differed significantly by sex at l000Hz(t=5.557. p<0.001). 4000Hz(t=2.234. p<0.05) and 8000Hz (t=2.730. p<0.01). According to general and vocational high schools(p<0.001) at 500Hz (t=-4.730), 1000Hz(t=-6.271). 2000Hz (t=-4.573). 4000Hz(t=-3.554) and 8000Hz (t=-3.405) significant differences were also shown. Grades impacted at 500Hz(t=2.201. p<0.05) and 4000Hz(t=2.511. p<0.05), while marks were significant at l000Hz(F=4.1l5. p<0.05) and drinking was significant at 500Hz(t=2.333. p<0.05). 3. The left hearing threshold in accordance with use of PCPs differed significantly at 2000Hz(F=2.996. p=0.03l) according to volume level and at 8000Hz(F=2.197. p=0.022) according to duration${\times}$hours per day. The right hearing threshold differed significantly at l000Hz(F=3.075. p=0.028) according to volume level and at 8000Hz(F=2.925. p=0.034) according to duration. 4. The knowledge and attitudes about noise showed a light positive correlation with the perception of hearing loss. A positive correlation was shown. as stated previously in all Hz, between the left hearing threshold and the right hearing threshold, especially the highest correlation at 2000Hz(r=0.761. p=0.000). This study has shown that the factors related to adolescent's use of PCPs are important as they impact significantly an adolescent's hearing. These results then indicate that in future, when designing a hearing conservation program and prevention education this data should be considered.

  • PDF

An Improved Procedure for Component Scheduling in Two Printed Circuit Pack Sequencers (두대의 PCP 생산기계에서의 부품 스케쥴링을 위한 개선방법)

  • Kim, Hyoun-S.;Kang, Hyoun-G.;Lee, Chae-Y.
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.21 no.4
    • /
    • pp.479-491
    • /
    • 1995
  • An improved heuristic procedure is presented which minimizes the changeovers of components in manufacturing printed circuit packs (PCP). The proposed procedure first groups similar components and PCPs together as in an existing method. The procedure then assigns each group to a machine such that the load on two machines is balanced. Considerable improvement is obtained compared to the best procedure available in the literature.

  • PDF

Initial Experience of the Emergency Bypass System ($EBS^{(R)}$) for the Patients with Cardiogenic Shock due to an Acute Myocardial Infarction (급성 심근경색으로 인한 심인성 쇼크 환자에 대한 경피적 순환 보조장치($EBS^{(R)}$) 적용의 초기경험)

  • Ryu, Kyoung-Min;Kim, Sam-Hyun;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon;Kim, Young-Hwa;Park, Seong-Sik
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.329-334
    • /
    • 2008
  • Background: Percutaneous cardiopulmonary support. (PCPS) has the potential to rescue patients in cardiogenic shock who might otherwise die. PCPS has been a therapeutic option in a variety of the clinical settings such as for patients with myocardial Infarction, high-risk coronary intervention and postcardiotomy cardiogenic shock, and the PCPS device is easy to install. We report our early experience with PCPS as a life saving procedure in cardiogenic shock patients due to acute myocardial infarction. Material and Method: From January 2005 to December 2006, eight patients in cardiogenic shock with acute myocardial infarction underwent PCPS using the CAPIOX emergency bypass system($EBS^{(R)}$, Terumo, Tokyo, Japan). Uptake cannulae were inserted deep into the femoral vein up to the right atrium and return cannulae were inserted into the femoral artery with Seldinger techniques using 20 and 16-French cannulae, respectively. Simultaneously, autopriming was performed at the $EBS^{(R)}$ circuit. The $EBS^{(R)}$ flow rate was maintained between $2.5{\sim}3.0L/min/m^2$ and anticoagulation was performed using intravenous heparin with an ACT level above 200 seconds. Result: The mean age of patients was $61.1{\pm}14.2$ years (range, 39 to 77 years). Three patients were under control of the $EBS^{(R)}$ before percutaneous coronary intervention (PCI), three patients were under control of the $EBS^{(R)}$ during PCI, one patient was under control of the $EBS^{(R)}$ after PCI, and one patient was under control of the $EBS^{(R)}$ after coronary bypass surgery. The mean support time was $47.5{\pm}27.9$ hours (range, 8 to 76 hours). Five patients (62.5%) could be weaned from the $EBS^{(R)}$ after $53.6{\pm}27.2$ hours. (range, 12 to 68 hours) of support. All of the patients who could successfully be weaned from support were discharged from the hospital. There were three complications: one case of gastrointestinal bleeding and two cases of acute renal failure. Two of the three mortality cases were under cardiac arrest before $EBS^{(R)}$ support, and one patient had an intractable ventricular arrhythmia during the support. All of the discharged patients are still surviving at $16.8{\pm}3.1$ months (range, 12 to 20 months) of follow-up. Conclusion: The use of $EBS^{(R)}$ for cardiogenic shock caused by an acute myocardial infarction could rescue patients who might otherwise have died. Successfully recovered patients after $EBS^{(R)}$ treatment have survived without severe complications. More experience and additional clinical investigations are necessary to elucidate the proper installation timing and management protocol of the $EBS^{(R)}$ in the future.

Ergonomic Evaluation and Safety Countermeasures of Personal Cassette Player Noise (휴대용 카세트 소음의 인간공학적 평가 및 안전대책)

  • Park, Min-Yong;Hong, Seong-Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.47-55
    • /
    • 1999
  • Recently, noise from personal cassette players (PCP) poses growing concerns together with occupational noise-induced hearing loss. Eighteen male and female volunteer subjects participated to determine preferred noise levels for PCP usage before, during, and after 2-hour subway riding according to sources (types) of PCP listening (language/news, soft music, and hard music). Audiometric tests were conducted before and after the 2-hour exposure of PCP noise under subway riding. Statistical analyses showed some significant hearing losses with the greatest loss of more than 6 dB at 4000 Hz for both ears, indicating that serious noise-induced hearing loss would potentially occurred due to prolonged use of PCPs. Practical safety countermeasures against PCP noise are further discussed.

  • PDF

Directonal Square Pulse Generator construct for Blumlein lain (Blumlein 회로로 구성한 단방향 구형파 펄스 발생기)

  • Kim, Jung-Dal;Chang, Gi-Hyuk;Joo, Sung-Chul;Jung, Jang-Gun;Lee, Duck-Jin;Lee, Yong-Gill
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1779-1781
    • /
    • 1998
  • We are going to design the Square Pulse Generator use of PCPS (Photo-Conductive Power Switch) for Blumlein lain. The circeuit is made of LC device and it is simulated by Schematics Evaluation Version 8.0 of MicroSim. After charged by DC voltage 15[kV]. When the switch is ON, Square pulse is generated after pause time 1.7857[${\mu}s$]. The square pulse is maximum peak voltage 13.987[kV], pulsed width 3.4017[${\mu}s$], rising time 0.7474[${\mu}s$], falling time 1.1718[${\mu}s$].

  • PDF

Colon Cancer among Older Saudis: Awareness of Risk Factors and Early Signs, and Perceived Barriers to Screening

  • Galal, Yasmine Samir;Amin, Tarek Tawfik;Alarfaj, Abdulelah Khalid;Almulhim, Abdulaziz Abdullah;Aljughaiman, Abdullah Abdulmohsen;Almulla, Abdulrhaman Khaled;Abdelhai, Rehab Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1837-1846
    • /
    • 2016
  • Background: Colon cancer screening (CRCS) uptake is markedly affected by public awareness of the disease. This study was conducted to assess levels of knowledge of CRC, to explore the pattern of CRCS uptake and identify possible barriers to screening among Saudis older than 50 years of age and primary care providers (PCPs) in Al Hassa region, Saudi Arabia. Materials and Methods: This cross-sectional study was conducted in randomly selected primary health care (PHC) centers, 884 Saudis and 39 PCPs being enrolled for data collection. Structured interviews were conducted to obtain information regarding socio-demographic characteristics, personal information relevant to CRC, awareness about early signs/symptoms and risk factors, and barriers to CRCS. Also, a self- administered data collection form was used to assess barriers to CRCS from the physicians' perspectives. Results: More than 66% of participants were lacking knowledge about CRC. Participants with higher educational levels, having ever heard about CRC, and having relatives with CRC had a significantly higher awareness of the disease. The rate of reported CRCS was low (8.6%). After conducting a logistic regression analysis, it was observed that female gender (OR=0.28; 95% CI=0.14-0.57; P=0.001), being unmarried (OR=0.11; 95% CI=0.10-0.23; P=0.001), lower levels of education (OR=0.36; 95% CI=0.16-0.82; P=0.015), and having no relatives with CRC (OR=0.30; 95% CI=0.17-0.56; P=0.001) were significantly associated with a lower CRCS uptake. There was a significant difference between most of the perceived barriers to CRCS and gender. Exploratory factor analysis showed that personal fear (especially fear of the screening results and shyness) was the major factor that hindered CRCS with high loading Eigen value of 2.951, explaining 34.8% of the barriers of the included sample toward utilization of CRCS, followed by lack of awareness of both person and providers (high Eigen value of 2.132, and explaining 23.7% of the barriers). The most frequently cited barriers to CRCS from the physicians' perspectives were lack of public awareness, lack of symptoms and signs, and fear of painful procedures. Conclusions: Poor levels of knowledge about CRC were found among older Saudis attending PHC centers in Al Hassa, Saudi Arabia. It is crucial to implement an organized national screening program in Saudi Arabia to increase public awareness.