• Title/Summary/Keyword: PCL-5

Search Result 127, Processing Time 0.022 seconds

Preparation and Characterization of Nanoparticles Using Poly(N-isopropylacrylamide)-$Poly({\varepsilon}-caprolactone)$ and Poly(ethylene glycol)-$Poly({\varepsilon}-caprolactone)$ Block Copolymers with Thermosensitive Function

  • Choi, Chang-Yong;Jang, Mi-Kyeong;Nah, Jae-Woon
    • Macromolecular Research
    • /
    • v.15 no.7
    • /
    • pp.623-632
    • /
    • 2007
  • Thermosensitive nanoparticles were prepared via the self-assembly of two different $poly({\varepsilon}-caprolactone)$-based block copolymers of poly(N-isopropylacrylamide)-b-$poly({\varepsilon}-caprolactone)$ (PNPCL) and poly(ethylene glycol)-b-$poly({\varepsilon}-caprolactone)$ (PEGCL). The self-aggregation and thermosensitive behaviors of the mixed nanoparticles were investigated using $^1H-NMR$, turbidimetry, differential scanning microcalorimetry (micro-DSC), dynamic light scattering (DLS), and fluorescence spectroscopy. The copolymer mixtures (mixed nanoparticles, M1-M5, with different PNPCL content) formed nano-sized self-aggregates in an aqueous environment via the intra- and/or intermolecular association of hydrophobic PCL chains. The microscopic investigation of the mixed nanoparticles showed that the critical aggregation concentration (cac), the partition equilibrium constants $(K_v)$ of pyrene, and the aggregation number of PCL chains per one hydrophobic microdomain varied in accordance with the compositions of the mixed nanoparticles. Furthermore, the PNPCL harboring mixed nanoparticles evidenced phase transition behavior, originated by coil to the globule transition of PNiPAAm block upon heating, thereby resulting in the turbidity change, endothermic heat exchange, and particle size reduction upon heating. The drug release tests showed that the formation of the thermosensitive hydrogel layer enhanced the sustained drug release patterns by functioning as an additional diffusion barrier.

Drug Release Behavior of Poly($\varepsilon$-caprolactone )-b-Poly( acrylic acid) Shell Crosslinked Micelles below the Critical Micelle Concentration

  • Hong Sung Woo;Kim Keon Hyeong;Huh June;Ahn Cheol-Hee;Jo Won Ho
    • Macromolecular Research
    • /
    • v.13 no.5
    • /
    • pp.397-402
    • /
    • 2005
  • To explore the potential of shell crosslinked micelle (SCM) as a drug carrier, the drug release behavior of poly($\varepsilon$-caprolactone)-b-poly(acrylic acid) (PCL-b-PAA) SCMs was investigated. PCL-b-PAA was synthesized by ring opening polymerization of $\varepsilon$-caprolactone and atom transfer radical polymerization of tert-butyl acrylate, followed by selective hydrolysis of tert-butyl ester groups to acrylic acid groups. The resulting amphiphilic polymer was used to prepare SCMs by crosslinking of PAA corona via amidation chemistry. The drug release behavior of the SCMs was studied, using pyrene as a model drug, and was compared with that of non-crosslinked micelles, especially below the critical micelle concentration (CMC). When the shell layers were crosslinked, the drug release behavior of the SCMs was successfully modulated at a controlled rate compared with that of the non-crosslinked micelles, which showed a burst release of drug within a short time.

Open Posterior Approach versus Arthroscopic Suture Fixation for Displaced Posterior Cruciate Ligament Avulsion Fractures: Systematic Review

  • Song, Jae-Gwang;Nha, Kyung-Wook;Lee, Se-Won
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.275-283
    • /
    • 2018
  • Purpose: To compare the clinical outcomes between the open posterior approach and arthroscopic suture fixation for displaced posterior cruciate ligament (PCL) avulsion fractures. Methods: A literature search was performed on MEDLINE, EMBASE, and the Cochrane Library databases. The inclusion criteria were as follows: papers written in English on displaced PCL avulsion fractures, clinical trial(s) with clear description of surgical technique, adult subjects, a follow-up longer than 12 months and modified Coleman methodology score (CMS) more than 60 points. Results: Twelve studies were included with a mean CMS value of 72.4 (standard deviation, 7.6). Overall, 134 patients underwent the open posterior approach with a minimum 12-month follow-up, and 174 patients underwent arthroscopic suture fixation. At final follow-up, the range of Lysholm score was 85-100 for the open approach and 80-100 for the arthroscopic approach. Patients who were rated as normal or nearly normal in the International Knee Documentation Committee subjective knee assessment were 92%-100% for the open approach and 90%-100% for the arthroscopic approach. The range of side-to-side difference was 0-5 mm for both approaches. Conclusions: Both arthroscopic and open methods for the treatment of PCL tibial-side avulsion injuries resulted in comparably good clinical outcomes, radiological healing, and stable knees.

Fabrication of Nanofiber-Combined 3D Scaffolds using Dual-Head Deposition Technology (듀얼헤드 적층 기술을 이용한 나노섬유로 결합된 3D 인공지지체 제작)

  • Sa, Min-Woo;Lee, Chang-Hee;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.108-115
    • /
    • 2018
  • In bone tissue engineering, polycaprolactone (PCL) is one of the most widely used biomaterials to manufacture scaffolds as a synthetic polymer with biodegradability and biocompatibility. The polymer deposition system (PDS) with four axis heads, which can dispense bio-polymers, has been used in scaffold fabrication for tissue engineering applications. A dual-head deposition technology of PDS is an effective technique to fabricate 3D scaffolds. The electrospinning technology has been widely used to fabricate porous and highly interconnected polymer fibers. Thus, PDS can fabricate nanofiber-combined hybrid scaffolds using fused deposition modeling (FDM) and electrospinning methods. This study aims to fabricate nanofiber-combined scaffolds with uniform nanofibers using PDS. The PCL nanofibers were fabricated and evaluated according to the fabrication process parameters. PCL nanofibers were successfully fabricated when the applied voltage, tip-to-collector distance, flow rate, and solution concentration were 5 kV, 1 cm, 0.1 ml/h, and 8 wt%, respectively. The cell proliferation was evaluated according to the electrospinning time. Scanning electron microscopy was used to acquire images of the cross-sectioned hybrid scaffolds. The cell proliferation test of the PCL and nanofiber-combined hybrid scaffolds was performed using a CCK-8 assay according to the electrospinning time. The result of in-vitro cell proliferation using osteosarcoma MG-63 cells shows that the hybrid scaffold has good potential for bone regeneration.

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Controlled Production of Monodisperse Polycaprolactone Microparticles using Microfluidic Device (미세유체장치를 이용한 생분해성 Polycarprolactone의 단분산성 미세입자 생성제어)

  • Jeong, Heon-Ho
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.283-288
    • /
    • 2019
  • Monodisperse microparticles has been particularly enabling for various applications in the encapsulation and delivery of pharmaceutical agents. The microfluidic devices are attractive candidates to produce highly uniform droplets that serve as templates to form monodisperse microparticles. The microfluidic devices that have micro-scale channel allow precise control of the balance between surface tension and viscous forces in two-phase flows. One of its essential abilities is to generate highly monodisperse droplets. In this paper, a microfluidic approach for preparing monodisperse polycaprolactone (PCL) microparticles is presented. The microfluidic devices that have a flow-focusing generator are manufactured by soft-lithography using polydimethylsiloxane (PDMS). The crucial factors in the droplet generation are the controllability of size and monodispersity of the microdroplets. For this, the volumetric flow rates of the dispersed phase of oil solution and the continuous phase of water to generate monodisperse droplets are optimized. As a result, the optimal flow condition for droplet dripping region that is able to generate uniform droplet is found. Furthermore, the droplets containing PCL polymer by solvent evaporation after collection of droplet from device is solidified to generate the microparticle. The particle size can be controlled by tuning the flow rate and the size of the microchannel. The monodispersity of the PCL particles is measured by a coefficient of variation (CV) below 5%.

PCL Reconstruction using Arthroscopic Posterior Transseptal technique (관절경하 후격막 통과 도달법을 이용한 후방 십자 인대의 재건술)

  • Kim, Jin-Goo;Kang, Yeong-Hun;Kang, Kyoung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.111-116
    • /
    • 2000
  • Purpose : We reviewed the results of arthroscopic posterior cruciate ligament reconstruction using Achilles tendon allograft, and the efficacy of the surgical technique using gradual tibial tunneling and posterior transseptal technique. Materials and Methods : From september 1997 to September 1999, 8 patients with complete PCL injury were treated by arthroscopic PCL reconstruction using Achilles tendon allograft. Mean follow-up period was 21.7 months. Mean preoperative posterior laxity was 14mm. The clinical outcome was assessed by Telos stress test, Lysholm knee score and IKDC score. Result : There was no complication such as infection and neurovascular injury. Posterior translation using Telos device was less than 5mm in 6 cases$(75\%)$, and between 6 to 10mm in 2 cases$(25\%)$. The mean Lysholm knee score was 45 preoperatively and improved to 87 postoperatively. In IKDC system, 2 of 8 patients were group A and 6 were group B. Conclusion : Arthroscopic PCL reconstruction using achilles tendon allograft and posterior transseptal technique shows reliable stability, short operative time and minimizing donor site morbidity but needs more long term follow-up.

  • PDF

Prevalence of posttraumatic stress disorder in orthopedic trauma patients and a call to implement the Injured Trauma Survivor Screen as a prospective screening protocol in the United States

  • Victoria J. Nedder;Mary A. Breslin;Vanessa P. Ho;Heather A. Vallier
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.67-73
    • /
    • 2024
  • Purpose: Posttraumatic stress disorder (PTSD) is prevalent and is associated with protracted recovery and worse outcomes after injury. This study compared PTSD prevalence using the PTSD Checklist for DSM-5 (PCL-5) with the prevalence of PTSD risk using the Injured Trauma Survivor Screen (ITSS). Methods: Adult trauma patients at a level I trauma center were screened with the PCL-5 (sample 1) at follow-up visits or using the ITSS as inpatients (sample 2). Results: Sample 1 (n=285) had significantly fewer patients with gunshot wounds than sample 2 (n=45) (8.1% vs. 22.2%, P=0.003), nonsignificantly fewer patients with a fall from a height (17.2% vs. 28.9%, P=0.06), and similar numbers of patients with motor vehicle collision (40.7% vs. 37.8%, P=0.07). Screening was performed at a mean of 154 days following injury for sample 1 versus 7.1 days in sample 2. The mean age of the patients in sample 1 was 45.4 years, and the mean age of those in sample 2 was 46.1 years. The two samples had similar proportions of female patients (38.2% vs. 40.0%, P=0.80). The positive screening rate was 18.9% in sample 1 and 40.0% in sample 2 (P=0.001). For specific mechanisms, the positive rates were as follows: motor vehicle collisions, 17.2% in sample 1 and 17.6% in sample 2 (P>0.999); fall from height, 12.2% in sample 1 and 30.8% in sample 2 (P=0.20); and gunshot wounds, 39.1% in sample 1 and 80.0% in sample 2 (P=0.06). Conclusions: The ITSS was obtained earlier than PCL-5 and may identify PTSD in more orthopedic trauma patients. Differences in the frequency of PTSD may also be related to the screening tool itself, or underlying patient risk factors, such as mechanism of injury, or mental or social health.

An Analysis on Characteristics of Turbulence Energy Dissipation Rate from Comparison of Wind Profiler and Rawinsonde (연직바람관측장비와 레윈존데의 비교를 통한 난류 에너지 감소률의 특성 분석)

  • Kang, Woo Kyeong;Moon, Yun Seob;Jung, Ok Jin
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.448-464
    • /
    • 2016
  • The purpose of this study is to optimize the parameters related to consensus coherency within the PCL 1300, the operating program of wind profiler, from a validation of wind data between rawinsonde and wind profiler at Chupungryeong ($36^{\circ}13^{\prime}$, $127^{\circ}59^{\prime}$) site in Korea. It is then to analyze the diurnal and seasonal characteristics of the turbulence energy dissipation rate (${\varepsilon}$) in clear and rainy days from March 2009 to February 2010. In comparison of the wind data between wind profiler and rawinsonde during April 22-23, 2010, it was shown in a big error more than $10ms^{-1}$ over the height of 3,000 meters in the zonal (u) and meridional (v) wind components. When removing more than $10ms^{-1}$ in each wind speed difference of u an v components between the two instruments, the correlation coefficients of these wind components were 0.92 and 0.88, respectively, and the root mean square errors were 3.07 and $1.06ms^{-1}$. Based on these results, when the data processing time and the minimum available data within the PCL 1300 program were adjusted as 30 minutes and 60%, respectively, the bias errors were small. In addition, as a result of an analysis of sensitivity to consensus coherency of u and v components within the PCL1300 program, u components were underestimated in radial coherency, instantaneous and winbarbs coherency, whereas v components were overestimated. Finally by optimizing parameters of the PCL1300 program, the diurnal and seasonal means of ${\varepsilon}$ at each height were higher in rainy days than those in clear days because of increasing in the vertical wind speed due to upward and downward motions. The mean ${\varepsilon}$ for clear and rainy days in winter was lower than those of other seasons, due to stronger horizontal wind speed in winter than those in other seasons. Consequently, when the turbulence energy dissipation rates in the vertical wind speed of more than ${\pm}10cm\;s^{-1}$ were excluded for clear and rainy days, the mean ${\varepsilon}$ in rainy days was 6-7 times higher than that in clear days, but when considering them, it was 4-5 times higher.

Beckmann Rearrangement of Ring A Steroidal Oxime Using the Carbon tetrachloride-triphenylphosphine (사염화탄소와 트리페닐포스핀을 사용한 스테로이드 링 A 옥심의 벡크만 자리옮김반응)

  • Kim Jack C.;Choi Soon-Kyu;Park Won-Woo;Lee Yong-Tae
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.42-45
    • /
    • 1979
  • The experimental procedures of Beckmann rearrangement mostly involve the use of vigorous conditions such as strongly acidic reagents (conc. HCl, $H_2SO_4$, $PCl_5$, etc.) or elevated temperatures, which frequently cause isomerization of ketooximes prior to rearrangement.We have effected the Beckmann rearrangement on $5{\alpha}$-cholestan-3-one oxime using the carbon tetrachloride-triphenylphosphine reagent under mild, neutral conditions to give 3-aza-A-homo-$5{\alpha}$-cholestan-4-one. This new, mild, facile and rapid general method of Beckmann rearrangement is presented, and compared with the classical (more conventional) Beckmann reagent of polyphosphoric acid.

  • PDF