• Title/Summary/Keyword: PCE17

Search Result 23, Processing Time 0.012 seconds

Remediation of PCE-contaminated Groundwater Using Permeable Reactive Barrier System with M0M-Bentonite (MOM-Bentonite 투수성반응벽체를 이용한 PCE로 오염된 지하수의 정화)

  • Chung, Sung-Lae;Lee, Dal-Heui
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.73-80
    • /
    • 2012
  • The objectives of this research were to study the applicability and limitations of permeable reactive barrier (PRB) for the removal of tetrachloroethylene (PCE) from the groundwater. PRB column tests were conducted using reactive material with Moringa Oleifera Mass - Bentonite (Mom-Bentonite). Most of the PCE in the groundwater was degraded and/or captured (sorpted) in the zone containing activated material (MOM-Bentonite). The removal rate of PCE from the groundwater was 90% and 75% after 30 days and 180 days, respectively. The effect of micro-organisms on the long-term permeability and reactivity of the barrier is not well understood. MOM-Bentonite PRB system in this research has the potential to be developed into an environmentally and economically acceptable technology for the in situ remediation of PCE-contaminated groundwater.

The effects of a Mixture of Puerariae Flos Extract and Citri Unshius Pericarpium Extract on Estrogenic Activities and Osteoclastogenesis (갈화(葛花)와 진피(陳皮) 추출물로 이루어진 복합물의 에스트로겐 활성과 파골세포 분화억제효과)

  • Cho, Hosong;Lee, Boyoung;Lee, Won Kyung;Lee, Jun Ho;Park, Dongjun;Choi, Changil;Jin, Mu Hyun;Roh, Seok-Seon;Ju, Young-Sung
    • The Korea Journal of Herbology
    • /
    • v.35 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • Objectives : In this study, we examined the estrogenic activities and anti-osteo clastogenesis effects of PCE17, a mixture of PE (an extract of Puerariae Flos), and CE (an extract of Citri Unshius Pericarpium). Methods : The estrogenic effect of PCE17, PE and CE were examined by ER-β/ERE reporter gene assay and proliferation assay in 293 T and MCF-7 cells. The expression of estrogen-responsive gene and protein were checked by Real Time-PCR (RT-PCR) and Western blotting in MCF-7 cells. Inhibitory effect of PCE17, PE and CE on RANKL-induced osteoclast differentiation were evaluated by TRAP staining and RT-PCR in primary osteoclast precursors from rat bone marrow cells. Results : PCE17 and PE bind to ERs (estrogen receptors) and show estrogenic activities in 293T cells. They also stimulated the proliferation of MCF-7 cells and increased the expression of ER response gene, pS2. Tectorigenin, an active ingredient of PE, shows similar estrogenic activities in MCF-7 cells. PCE17 and CE inhibited RANKL-induced osteoclastogenesis in rat primary osteoclast precursor cells and down-regulated the osteoclast-specific genes of Nfatc1, Ctsk, and Acp5. Conclusions : In conclusion, PCE17 may have therapeutic potential in cases of menopause and osteoporosis.

Gas phase Photocatalytic Oxidation of PCE with $TiO_2$ ($TiO_2$를 이용한 PCE의 기상 광산화처리)

  • 조인철;변종환;변은숙;이동근;김성우
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.57-66
    • /
    • 2001
  • Gas phase photocatalytic oxidation of tetrachloroethylene (PCE) under 370 nm ultra-violet irradiation was investigated with TiO$_2$ catalyst. During the photocatalytic oxidation of PCE vapor several kinds of intermediate were produced, and the reaction pathways were proposed on the basis of the production sequency of the intermediates. The intermediates in the pathways of PCE oxidation were hexachloroethane, pentachlotoethane, 1, 1, 2-trichloroethane, carbon tetrachl-oride, dichloroacetylchloride, chloroform, 1,1-dichloroethane, phosgene, CO, $CO_2$, HCl, Cl$_2$.

  • PDF

A Mathematical Model for Determination of PCE's Based on Delay for Two-Lane Two-Way Highway (양방향 2차로 도로의 지체시간 산정을 이용한 승용차환산계수 결정이론)

  • 이승준;최재성
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.2
    • /
    • pp.149-162
    • /
    • 1999
  • One of the most important steps of the design, capacity and operation analysis stapes in the two-lane two way highways is the effect of heavy vehicle to traffic flow quality. This heavy vehicle's effect on traffic flow can be represented as PCE, which is the number of passenger cars that are displaced by a single heavy vehicle of a particular type under prevailing roadway, traffic, and control conditions. In this paper, we focus on the heavy vehicles effect on volume, speed, delay, and the maneuver of freedom which are major MOE's in traffic operation analysis and PCE criterion which should be measurable, determinable and able to reflect the traffic flow characteristics. Therefore, the objective of the paper is to determine the PCE criterion and to develop a new PCE determination method. In this study, delay is adopted as PCE criterion and, for calculation of delay, the highway is divided into the passing zone and the no-passing zone. PCE is determined by comparing the delay due to total traffic flow interaction with the delay due to a single heavy vehicle, Also, this paper proposes a new method to determine the average PCE on the highway that has the passing zones and no-passing zones.

  • PDF

Estimation of Optimal Passenger Car Equivalents of TCS Vehicle Types for Expressway Travel Demand Models Using a Genetic Algorithm (고속도로 교통수요모형 구축을 위한 유전자 알고리즘 기반 TCS 차종별 최적 승용차환산계수 산정)

  • Kim, Kyung Hyun;Yoon, Jung Eun;Park, Jaebeom;Nam, Seung Tae;Ryu, Jong Deug;Yun, Ilsoo
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.97-105
    • /
    • 2015
  • PURPOSES : The Toll Collection System (TCS) operated by the Korea Expressway Corporation provides accurate traffic counts between tollgates within the expressway network under the closed-type toll collection system. However, although origin-destination (OD) matrices for a travel demand model can be constructed using these traffic counts, these matrices cannot be directly applied because it is technically difficult to determine appropriate passenger car equivalent (PCE) values for the vehicle types used in TCS. Therefore, this study was initiated to systematically determine the appropriate PCE values of TCS vehicle types for the travel demand model. METHODS : To search for the appropriate PCE values of TCS vehicle types, a traffic demand model based on TCS-based OD matrices and the expressway network was developed. Using the traffic demand model and a genetic algorithm, the appropriate PCE values were optimized through an approach that minimizes errors between actual link counts and estimated link volumes. RESULTS : As a result of the optimization, the optimal PCE values of TCS vehicle types 1 and 5 were determined to be 1 and 3.7, respectively. Those of TCS vehicle types 2 through 4 are found in the manual for the preliminary feasibility study. CONCLUSIONS : Based on the given vehicle delay functions and network properties (i.e., speeds and capacities), the travel demand model with the optimized PCE values produced a MAPE value of 37.7%, RMSE value of 17124.14, and correlation coefficient of 0.9506. Conclusively, the optimized PCE values were revealed to produce estimates of expressway link volumes sufficiently close to actual link counts.

Development of Practical Advanced Oxidation Treatment System for Decontamination of Soil and Groundwater Contaminated with Chlorinated Solvent (TCE, PCE) : Phase I (염소계 화합물(TCE, PCE)로 오염된 토양 및 지하수 처리를 위한 실용적 고도산화처리시스템 개발 (I))

  • Sohn, Seok-Gyu;Lee, Jong-Yeol;Jung, Jae-Sung;Lee, Hong-Kyun;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.105-114
    • /
    • 2007
  • The most advanced oxidation processes (AOPs) are based on reactivity of strong and non-selective oxidants such as hydroxyl radical (${\cdot}OH$). Decomposition of typical DNAPL chlorinated compounds (TCE, PCE) using various advanced oxidation processes ($UV/Fe^{3+}$-chelating agent/$H_2O_2$ process, $UV/H_2O_2$ process) was approached to develop appropriate methods treating chlorinated compound (TCE, PCE) for further field application. $UV/H_2O_2$ oxidation system was most efficient for degrading TCE and PCE at neutral pH and the system could remove 99.92% of TCE after 150 min reaction time at pH 6($[H_2O_2]$ = 147 mM, UVdose = 17.4 kwh/L) and degrade 99.99% of PCE within 120 min ($[H_2O_2]$ = 29.4 mM, UVdose = 52.2 kwh/L). Whereas, $UV/Fe^{3+}$-chelating agent/$H_2O_2$ system removed TCE and PCE ca. > 90% (UVdose = 34.8 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 147 mM) and 98% after 6hrs (UVdose = 17.4 kwh/L, $[Fe^{3+}]$ = 0.1 mM, [Oxalate] = 0.6 mM, $[H_2O_2]$ = 29.4 mM), respectively. We improved the reproduction system with addition of UV light to modified Fenton reaction by increasing reduction rate of $Fe^{3+}$ to $Fe^{2+}$. We expect that the system save the treatment time and improve the removal efficiencies. Moreover, we expect the activity of low molecular organic compounds such as acetate or oxalate be effective for maintaining pH condition as neutral. This oxidation system could be an economical, environmental friendly, and practical treatment process since the organic compounds and iron minerals exist in nature soil conditions.

Capacity Variation of a Microcell due to Power Control Error in and Overlaid Macrocell/Microcell CDMA System (매크로셀내에 마이크로셀이 중첩된 CDMA 시스템에서 전력제어오차로 의한 마이크로셀의 용량 변화)

  • 강희곡;김영철;노재성;조성준
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.8-17
    • /
    • 2000
  • The BER performance and the capacity variation of a microcell due to power control error(PCE) is analyzed on service types(data and voice, respectively) for the reverse link of an overlaid cell CDMA system. The procedure of analysis is followed as: First, we calculate BER performance according to PCE. Next, we find the minimum SNR for voice service, BER=TEX>$10^{-3}$, and data service, BER=TEX>$10^{-5}$. Then, according to the calculated SNR, we find the maximum capacity of a microcell and macrocell and the capacity of a microcell where interference is considered is found and analyzed with that in perfect power control. We get to the results as follows. The BER performance in 1 dB PCE is similar to that in perfect power control, however, with a increase in PCE, the BER performance is largely degraded. In terms of capacity, it is shown that if the PCE is equal or less than 2 dB, the effect of the PCE on voice service is more than that on data service, but if the PCE is equal or more than 3 dB, effect of the PCE on data service is more than that on voice. Besides, if the PCE is equal or less than 2 dB, both PCE and interference should be considered to calculate the capacity of a microcell, but if the PCE is equal or more than 3 dB, interference can be negligible since the effect of PCE is much stronger than that of interference. Therefore, the microcell should be located where $R_d$, the ratio of a microcell to a macrocell radius, is equal to 0.1, and d, the ratio of the distance between a microcell and a macrocell to the macrocell radius, is equal or more than 0.5, in order to obtain a appropriate microcell capacity against interference. If $\sigma$ is adjusted to less than 2 dB, we may get equal or more than 70% of the maximum microcell capacity.

  • PDF

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Development of Practical Advanced Oxidation Treatment System for Decontamination of Soil and Groundwater Contaminated with Chlorinated Solvents (TCE, PCE): Phase II (염소계 화합물(TCE, PCE)로 오염된 토양 및 지하수 처리를 위한 실용적 고도산화처리시스템 개발 (II))

  • Kim, Sang-Yeek;Sohn, Seok-Gyu;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.2
    • /
    • pp.10-17
    • /
    • 2010
  • Advanced oxidation processes (AOPs) have advantages to reduce the processing time and mineralize contaminants dissolved in groundwater. Recently, remediation techniques for organic contamination in groundwater have been studied, and technology using $UV/H_2O_2$ is generally accepted as one of the most powerful and reliable alternative for the remediation of groundwater contamination. In this study, $UV/H_2O_2$ technology, which generates hydroxyl radical ($\cdot$ OH) as known for strong non-selective oxidant, was used to degrade chlorinated solvents (TCE and PCE), and it was expanded to apply continuous stirred tank reactor (CSTR) system (i.e. combinations of three CSTR). The tested parameters for CSTR system were retention time and groundwater/$H_2O_2$ injection volume ratio. To find optimum parameters for CSTR system, various retention time (6 min ~ 90 min) and groundwater/$H_2O_2$ injection volume ratio (5/1 ~ 119/1) were tested. Other conditions for CSTR were adapted from the batch test results, which concentration of $H_2O_2$ and UV dose were 29.4 mM (0.1%) and 4.3 kWh/L, respectively. Based on the experimental results, the optimum parameters for CSTR system were 20 min for retention time and 119/1 for groundwater/$H_2O_2$ injection volume ratio. Applying these optimum conditions, chlorinated solvents (TCE and PCE) were removed at 99.9% and 99.6%. Moreover, the effluent concentrations of TCE and PCE are 0.036 mg/L and 0.087 mg/L, respectively, which are satisfied the regulatory level (TCE 0.3 mg/L, PCE 0.1 mg/L). Consequently, the CSTR system using $UV/H_2O_2$ technology can achieve high removal efficiency in the event of treatment of groundwater contaminated by chlorinated solvents (TCE and PCE).

Human Risk Assessment of Perchloroethylene Considering Multi-media Exposure (다매체 노출을 고려한 Perchloroethylene의 인체위해성평가연구)

  • Seo, Jungkwan;Kim, Taksoo;Jo, Areum;Kim, Pilje;Choi, Kyunghee
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.5
    • /
    • pp.397-406
    • /
    • 2014
  • Objectives: Perchloroethylene (PCE) is a volatile chemical widely used as a solvent in the dry-cleaning and textile processing industries. It was evaluated as Group 2 "probably carcinogenic to humans" by the Integrated Risk Information System (IRIS) of the United State Environmental Protection Agency (U.S. EPA) in 2012. In order to provide a scientific basis for establishing risk management measures for chemicals on the national priority substances list, aggregate risk assessment was conducted for PCE, included in the top-10 substances. Methods: We conducted the investigation and monitoring of PCE exposure (e.g., exposure scenario, detection levels, and exposure factors, etc.) and assessed its multi-media (e.g., outdoor air, indoor air, and ground water) exposure risk with a deterministic and probabilistic approach. Results: In human risk assessment (HRA), the level of human exposure was higher in the younger age group. The exposure level through inhalation at home was the highest among the exposure routes. Outdoor air or uptake of drinking water represented less than 1% of total contributions to PCE exposure. These findings suggested that the level of risk was negligible since the Hazard Index (HI) induced by HRA was below one among all age groups, with a maximum HI value of 0.17 when reasonable maximum exposure was applied. Conclusion: In conclusion, it was suggested that despite low exposure risk, further studies are needed considering main sources, including occupational exposure.