• Title/Summary/Keyword: PCDDs

Search Result 86, Processing Time 0.025 seconds

Protective Effects of YCY against Hepatotoxicity Induced by 2,3,7,8-Tetrachlorodibenzo-p-dioxin(TCDD) in Rats

  • Woon Kwon;Chai, Hee-youl;Young min Cho;Park, Ehn-kyoung;Kim, Ik-soo;Ryu, Kang-sun;Hwang, Seock-Yeon;Yun, Chi-Young;Kang, Jong-Koo
    • Proceedings of the Korean Society of Veterinary Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.46-46
    • /
    • 2003
  • Polychlorinated dibenzo-p-dioxins (PCDDs) are widespread, persistant, and highly toxic environmental pollutants. TCDD is the most potent congener among PCDDs and the most thoroughly investigated model compound of this class of chemicals. These compounds elicit a variety of common biochemical and toxic response, including specific binding to the cytosolic AHR [1] and induces a variety of biological response ranging from induction of cytochrome P-450 1A (CYP1A) to liver damage and cancer [2]. This study was carried out to investigate the protective effects of YCY, extract of a cricket, Gryllus bimaculatus, on hepatotoxicity in 6-week-old SD rat exposured to TCDD (omitted)

  • PDF

Exposure Assessment of PCDD/Fs and Monitoring of Health Effects on Workers and Resident near the Waste Incinerators in Korea (국내 일부 소각장 근로자와 주변지역주민들의 PCDDs/Fs 노출과 건강 영향 평가)

  • Hong, Yun-Chul;Lee, Kwan-Hee;Kwon, Ho-Jang;Jang, Jae-Yeon;Leem, Jong-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.4
    • /
    • pp.314-322
    • /
    • 2003
  • Objectives : In this study, the exposure status of the hazardous substances from incinerators, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), were studied , and the relationship between the exposure of these hazardous substances and their heath effects on the workers and residents near municipal solid waste (MSW) incinerators and an industrial incinerator investigated. Methods : Between July 2001 and Jure 2002, 13 workers at two MSW incinerators, 16 residents from the area around the two MSW incinerators, 6 residents from the control area, and further 10 residents near an industrial incinerator, estimated to emit higher levels of hazardous substances, were interviewed. Information, including sociodemographic information, personal habits, and work history, detailed gynecologic and other medical history were collected through interviews. Blood samples were also collected from 45 subjects, and analyzed for PCDD/DFs, by high resolution gas chromatography -high resolution mass spectrometry, using the US EPA 1613 method. In addition to the questionnaire survey, urinary concentrations of 8-hydroxydeoxyguanosine (8-OH-dG) and malondialdehyde (MDA) were measured as oxidative injury biomarkers. The urinary concentrations of 8-OH-dG were determined by in vitro ELISA, and the MDA by HPLC, using u adduct with thiobarbituric acid. Results : The PCDD/DFs concentrations in the residents near the industrial incinerator were higher than those in the controls, workers and residents near the MSW incinerators. The average TEQ (Toxic Equivalencies) concentrations of the PCDD/DFs in residents near the industrial incinerator were 53.4pg I-TEQs/g lipid. The estimated daily intakes were within the tolerable daily intake range (1-4 pg I-TEQ/Kg bw/day) suggested by WHO (1997) in only 30% to the people near the industrial incinerator. Animal studies have already shown that even a low body border of PCDD/DFs, such as 10 ng TEQ/kg bw, can cause oxidative damage in laboratory animals. Our study also showed that the same body burden of PCDD/DFs can cause oxidative damage to humans. Conclusions : The exposures to PCDD/DFs and the oxidative stress of residents near the industrial incinerator, were higher than those in the controls, workers and residents near the MSW incinerators. Proper protection strategies against these hazardous chemicals are needed. Because a lower body burden of PCDD/Fs, such as 10ng TEQ/kg bw, can cause oxidative damage, the tolerable daily intake range should be restrictedly limited to 1pg I-TEQ/kg bw/day.

The Removal of Dioxins and the Formation of 2, 3, 7, 8-TeCDF in Drinking Water Treatment in Japan (정수처리에서의 다이옥신 제거 및 2, 3, 7, 8-TeCDF 생성)

  • Kim, Hyun-koo
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.758-766
    • /
    • 2008
  • To evaluate homologue patterns and removal efficiency before and after water treatment, the concentrations of dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and coplanar polychlorinated biphenyls (Co-PCBs) were determined in 122 samples from 42 drinking water treatment plants throughout Japan over a two year period. The mean concentrations and toxic equivalent (TEQ) values of dioxins in raw and treated waters were 60.24 pg/L (0.14 pg-WHO-TEQ/L) and 4.15 pg/L (0.016 pg-WHO-TEQ/L), respectively. The dioxins contribution ratio of drinking water in relation to dioxins tolerable daily intake (TDI, 4 pg-TEQ/kg/day) was 0.016%. The mean TEQ removal rate of dioxins by drinking water treatment was over 88%. However, the mean removal rate of 2, 3, 7, 8-TeCDF (tetrachlorodibenzofuran) by water treatment in the 122 samples was minus 17%. Therefore, to identify which process affected the level of 2, 3, 7, 8-TeCDF, the removal efficiencies at both the advanced and conventional water treatment plants were investigated. For the TEQ removal rate across the processes, the dioxin congeners, TeCDF and non-ortho-PCBs remarkably indicated minus values after chlorination in both the advanced and conventional water treatments plant. From this study, the level of 2, 3, 7, 8-TeCDF was found to be increased as a result of chlorination.

Dioxin Distributions from Combustion: Incinerator Data, Thermodynamic Data, and Kinetic Hypotheses

  • James A. Mulholland;Ryu, Jae-Yong
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.225-228
    • /
    • 1999
  • The formation of dioxin (term used here to refer to both polychlorinated dibenzo-p-dioxins, PCDDS, and dibenzofurans, PCBFs) in combustion processes is of concern because of the extreme toxicities of some of these compounds and because of their resistance to degradation in the environment. The number and location of chlorine substituents differentiate dioxin homologues and isomers, respectively. There are a total of 75 PCDD congeners and 135 PCDF congeners.(omitted)

  • PDF

A Study on the Contents of PCDDs/PCDFs in Ambient Air (대기중의 Dioxin 농도 분포에 대한 연구)

  • 김연제;김명수;양세현;이선영;유성옥;김신도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.47-49
    • /
    • 1999
  • 월남전 고엽제 피해와 도시 폐기물 소각로 문제로 일반에게 알려진 다이옥신(Dioxins and Furans)은 기존의 연구결과 토양, 호수와 강의 바닥, 대기, 수계생물, 동식물 및 인체조직 등 거의 모든 자연환경에 존재하는 것으로 밝혀졌다. 특히 도시의 대기는 도시 폐기물 소각로나 자동차 등 화것 연료의 연소에 의해 배출되는 다이옥신, PCBs, PAH 등 많은 오염 물질을 함유하고 있는데 이 중 독성이 가장 높은 물질이 다이옥신이다.(중략)

  • PDF

Environmental Endocrine Disruptors and Endometriosis

  • K.E. Joung;Kim, J.S.;H.W. Song;Y.Y. Sheen;S.K. Hong;S.B. Kang;Kim, H.;S.I. Cho
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2003.05a
    • /
    • pp.62-63
    • /
    • 2003
  • A case-control study was designed to determine the possible association between dioxin like compounds (such as TCDD, PCDDs, PCDFs, and PCBs) and the occurrence and severity of endometriosis using CALUX bioassay method.(omitted)

  • PDF

Application of Calux Bioassay for Determining Dioxin Toxicity Equivalents

  • Joung, Ki-Eun;An, Jin-Young;Sheen, Yhun-Yhong
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2003.10b
    • /
    • pp.172-173
    • /
    • 2003
  • There are growing concerns about human health effects of dioxin and dioxin like compounds such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs). Earlier studies recognized that 2.3.7.8-tetrachloro dibenzo-p-dioxin (TCDD) and structually related dioxin like compounds invoke a number of common toxic responses that are mediated through a high-affinity cytosolic receptor protein, the AhR.(omitted)

  • PDF

Analysis of PCDD/Fs and PCBs in Human Blood and Characteristics of Contamination Sources (국내 혈액에서의 PCDD/Fs 및 PCBs 분석과 오염원 특성에 관한 연구)

  • Yang, Yoon Hee;Kim, Byung Hoon;Chang, Yoon Seok
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.147-158
    • /
    • 2001
  • Polychlorinated dibenzo-p-dioxins(PCDDs), dibenzofurans(PCDFs), and biphenyls(PCBs) were analyzed by HRGC/HRMS in human blood samples from the Siwha industrial area in Korea. The PCDD/F and PCB concentrations in workers were higher than those in residents. The average TEQ concentrations of PCDD/Fs in workers and residents were 40.3 pg I-TEQs/g lipid and 16.6 pg I-TEQs/g lipid, respectively, and the total PCB concentrations were 174.1 ng/g lipid and 151.0 ng/g lipid, respectively. When applied to principal component analysis, the PCDD/F congener distributions of workers were differentiated from those of residents. But, all of them were similar to the distribution in several Korean foods. Estimated daily intake(EDI) of each person was calculated, and then only 40% to the total people were within the tolerable daily intake range(1-4pg I-TEQ/kg bw/day) suggested by WHO(1997).

  • PDF