• Title/Summary/Keyword: PCB 52

Search Result 51, Processing Time 0.027 seconds

Dielectric characteristics of PMMA-PZT coated Ni Composites (PMMA-PZT coated Ni 복합체의 유전특성)

  • Jeong, Won-Chae;Lee, Hee Young;Kim, Jeong-Joo;Im, Eun-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.349-349
    • /
    • 2005
  • 수동소자를 PCB(Printed Circuit Board) 안으로 집적하기 위한 방법의 일환으로 polymer-metal, polymer-ceramic composite에 연구가 국내외 연구 국내외 연구기관에서 광범위하게 진행되고 있다. 본 연구에서는 polymer-metal-ceramic composite 에서 PZT-coated Ni의 volume fraction에 따른 유전율 변화에 대하여 조사하였다. 원료로는 PZT(52/48) solution. 니켈금속분말, PMMA(polymethyl methacrylate)를 사용하였다. 전기적 특성은 임피던스분석기를 이용하여 측정하였으며 mixing rule과 percolation theory를 이용하여 결과를 해석하였다.

  • PDF

Effect of Cutting Conditions on Burr Formation in Micro-drilling of A6061 (A6060의 미소 드릴링시 절삭조건이 Burr 형성에 미치는 영향)

  • Park, Dong-Sam;Choi, Jong-Soon;Kwon, Sang-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.47-52
    • /
    • 1999
  • Theoretical and experimental studies on burr formation and deburring in many manufacturing processes have been actively pursued. Though micro-drilling has become more important in the production of precision parts such as PCB, air bearing, camera and nozzle, most studies on drilling burr formation have focused on the conventional drilling process. This paper describes burr formation process and the effect of cutting conditions such as spindle speed, feedrate and drilling depth per one step on burr formation in drilling A6061 with drills of diameter 1.0mm and 0.6mm. Experimental results showed that burr with cap were formed at relatively low feedrates, while petal burrs with several large burr fragments were formed at high feedrates. Burr height appeared to increase at the hight feedrates and lower spindle speeds. The effect of final cutting depth on burr height was negligible.

  • PDF

On the Distribution of PCBs and Organochlorine Pesticides in Fish and Sediment of the Asan Bay (아산만해역 어류체내와 퇴적물중의 PCB와 유기염소계농약 분포)

  • Choi, Jin-Young;Lee, Sung-Gyu;Bang, Jae-Hyun;Yang, Dong-Beom;Hong, Gi-Hoon;Shin, Kyoung-Hoon
    • Ocean and Polar Research
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2011
  • Distribution of Polychlorinated biphenyls (PCBs) and organochlorine pesticides in sediments, seawater and fish tissues were examined. Concentrations of ${\Sigma}PCBs$ and ${\Sigma}DDTs$ in the intertidal sediments of Asan Bay ranged from $1.90{\sim}3.27\;ng\;g^{-1}$ dw (dry weight) and $0.51{\sim}1.26\;ng\;g^{-1}$ dw, respectively. ${\Sigma}PCBs$ concentrations in the tissue of greenling (Hexagrammos otakii), olive flounder (Paralichthys olivaceus) and finespotted flounder (Pleuronichthys cornutus) were $1.27{\pm}0.55$, $1.30{\pm}0.71$ and $1.19{\pm}0.43\;ng\;g^{-1}$ ww (wet weight), respectively. The profile of PCBs in the sediments and the 3 species of fish differed as witnessed by the dominance of tetra- to penta-chlorinated congeners in sediments while penta- to hexa-chlorinated congeners dominated in fish. ${\Sigma}DDTs$ concentrations were $0.67{\pm}0.52$, $0.79{\pm}0.61$, $1.58{\pm}1.05\;ng\;g^{-1}$ ww respectively in the tissue of greenling, olive flounder and finespotted flounder. The p,p'-DDE appeared to be the most important metabolite of DDT in studied fishes. The concentrations of PCBs and organochlorine pesticides measured in this study for fish were generally lower than those of previous studies. Compared to the pollutant concentration quality guidelines in marine fish, the environment of Asan Bay appears to be in a healthy state.

Experimental Investigation for Ablation Characteristics of Polyimide Layer and Cu-metal Layer using High Power Nd:YAG UV Laser (고출력 Nd:YAG UV레이저를 이용한 polyimide층과 Cu-metal층의 가공상태에 대한 실험적 고찰)

  • Choi, Kyung-Jin;Lee, Young-Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • In this paper, the laser cutting characteristics of the flexible PCB using high power Nd:YAG UV laser were investigated. A specific FPCB model was selected for the experiment. Test sheets were made, which had equal materials and layer structure to those of the outline (OL) region and the contact pad (CP) region in the FPCB. The experiment is made up of two stages. In the first stage of the experiment, the laser cutting fluence was found, which is the threshold fluence to cut the test sheets completely. The laser cutting fluence of the OL sheet is $1781.26{\sim}1970.16\;J/cm^2$ and that of the CP sheet is $2109.34{\sim}2134.34\;J/cm^2$. In the second stage, cutting performance and its qualities were analyzed by the experiment. The laser cutting performance remained almost unchanged for all laser and process parameter sets. The average cutting width (top side/bottom side) of the OL sheet was $40.45\;{\mu}m/11.52\;{\mu}m$ and that of the CP sheet was $22.14\;{\mu}m/10.93\;{\mu}m$. However, the laser cutting qualities were different according to the parameters. The adjacent region of the cutting line on the OL sheet was carbonized as the beam speed was low and the overlap coefficient was high. The surface quality around the cutting line of the CP sheet was about the same. Carbonization and debris occurred on the surface of the cutting line. As a result of the experiment, the cutting qualities were better as the overlap coefficient was made low and beam speed high. Therefore, the overlap coefficient 2 or 3 is proper for the FPCB laser cutting.

  • PDF

A Simulation Investigation on the Spurious Emission Reduction of the Automotive DC-DC Converter (자동차용 DC-DC 컨버터의 전자파 방사 감소 방법에 대한 시뮬레이션 연구)

  • Chae, Gyoo-Soo
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.8
    • /
    • pp.47-52
    • /
    • 2020
  • In this study, a simulation investigation was conducted on the method of reducing switching noise and spurious emission among design methods for step-down DC-DC converter modules for automotive. A typical 4-layer converter circuit using a PMIC(Power Management Integrated Circuit) chip was presented, and the simulation results of conductive emissions at two input terminals (+, -) and the point between the input filter and the PMIC was performed in the 1.0~5.0MHz band and the 100MHz band. The results for the conducted and radiated emissions in the HF(3~30MHz) and VHF(30-300MHz) bands were presented. It showed an improvement of about 10dB over the bands by routing the output terminal placed on the 3 or 4-layer in the opposite direction to the input terminal. The result of this study is expected to be useful in the design of the DC-DC converter modules in the future because it gives a better improvement compared to the existing methods.

Assessment of the Potential Environmental Impact of Smart Phone using LCA Methodology (LCA 기법을 활용한 스마트폰의 잠재적 환경영향평가)

  • Heo, Young-chai;Bae, Dae-sik;Oh, Chi-young;Suh, Young-jin;Lee, Kun-mo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.527-533
    • /
    • 2017
  • Environmental concern about smart phone is growing because it has short product life span while having intensive production technology and cost. In this study environmental impact of the smart phone is quantified using the LCA methodology based on the ISO 14040 series standards. The assessment considers potential environmental impacts across the whole life cycle of the smart phone including; pre-manufacturing; manufacturing; distribution; product use; and end-of-life stages. The pre-manufacturing stage is the most dominant life cycle stage causing the highest environmental impacts among all 10 impact categories assessed. The global warming impacts of the smart phone in the pre-manufacturing, distribution, use, manufacturing, and end-of-life stages were 52.6% 23.9%, 15.7%, 7.0%, and 0.8%, respectively. Sensitivity of the life cycle impact assessment results to the system boundary definition and assumptions made were quite high. Three components of the smart phone, PCB, battery, and display module were identified as the key components causing majority of the potential environmental impact in the pre-manufacturing stage. As such the slim and light-weight design and the use of environmental friendly materials are important design factors for reducing the environmental impact of the smart phone.

Analysis of dioxin-like PCBs in Soil samples (토양 중 dioxin-like PCBs의 분석)

  • Kim, Kyeo Keun;Shin, Sun Kyoung;Kim, Tae Seung;Chang, JunYoung;Kim, Jeong-Gyu
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.466-474
    • /
    • 2002
  • The analytical method of 14 kinds of coplanar - PCBs was established and applied the soil sample. The three kinds of extraction solvents (toluene, acetone: n-hexane, dichloromethane) were selected to apply the soil sample. The silica gel, florisil and alumina column cleanup also performed to compare the elution recovery. The average recovery of selected solvents in soil A, B and C was surveyed the 84.25%, 56.09% and 44.69% for toluene, 52.56%, 81.42% and 58.53% for acetone : n - hexane and 55.94%, 71.33% and 61.05% for dichloromethane. The average recovery is represented 49.99% for silica gel (n - hexane 100 mL), 69.65% for florisil (6% ether/n - hexane 100 mL), and 65.23% for alumina (2% DCM : n - hexane 100 mL, 50% DCM: n-hexane 150 mL). In silica gel (n - hexane) and florisil (6% ether : n - hexane) cleanup, the 14 kinds of coplanar PCBs eluted until 40 mL. In the silica gel and florisil columns cleanup, the amounts of elution solvent can be reduced from these results, but the researcher has to confirm the elution amounts before performing the experiments. In alumina cleanup process, the result was obtained to the 100 mL of elution solvents (2% DCM: n-hexane 100 mL and 50% DCM: n-hexane 40 mL), therefore the change of elution solvent is necessary to develop the simple procedure.

PROTECTION EFFECT OF GINSENG EXTRACT AGAINST APOPTOTIC CELL DEATH INDUCED BY 2,2,5,5-TETRACHLOROBIPHENYL IN NEURONAL SK-N-MC CELLS

  • Lee, Ji-Young;Kim, Jae-Won;Song, Ji-Eun;Kim, Soo-Jung;Chung, Weon-Gu;Kim, Yong-Hoon;Lee, Bo-Ram;Kim, Jin-Hee;Choi, Young-Keun;Joo, Woo-Hong;Cho, Yong-Kweon;Moon, Ja-Young
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.112-112
    • /
    • 2001
  • Oxidative stress plays an important role in the pathological process of neurodegenerative diseases. Polychlorinated biphenyls (PCBs) are ubiquitous environmental contaminants, some of which may be neurotoxic. Our previous studies showed that 2,2',5,5'-TetracWorobiphenyl (PCB 52) induced apoptotic death in human neuronal SK-N-MC cells, which was demonstrated on gel electrophoresis by visualization of the proteolytic cleavages of $\beta$-catenin and poly (ADP-ribose) polymerase (PARP) and of the production of characteristic ladder patterns of DNA fragmentation.

  • PDF

Characteristics of Tool Wear and Surface Roughness using for Hybrid Lubrication in Micro-Milling Process of Flexible Fine Die (플렉서블 양각금형의 마이크로 밀링가공에서 하이브리드 윤활공정에 따른 공구마멸과 표면조도 특성)

  • Kim, Min-Wook;Ryu, Ki-Teak;Kang, Myung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.30-36
    • /
    • 2013
  • An FFD(flexible fine die) is an embossed mold that consists of a thin plate ranging from 0.6 to 3 mm in thickness. FFDs are primarily used for cutting LCD films and F-PCB sheets. In the high-speed micro-milling process of flexible fine dies, the lubrication and cooling of the cutting edges is very important from the aspect of eco machining and cutting performance. In this paper, a comparative study of tool wear and surface roughness between cutting fluid and hybrid lubrication for eco-machining of FFD was conducted for processes of high-speed machining of highly hardened material (STC5, HRC52). Especially, the incorporated fluid method for eco machining, in which the cutting performances can be simultaneously measured, was introduced. The machining results show that hybrid lubrication, instead of conventional cutting fluid, leads to excellent tool wear and surface roughness and represents the proper conditions for eco micro-machining of flexible fine dies.

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.