• Title/Summary/Keyword: PC wall

Search Result 172, Processing Time 0.032 seconds

A Study on the Effect of Accelerated Curing on 28-Days Compressive Strength of Concrete (촉진양생이 콘크리트의 28일 압축강도에 미치는 영향에 관한 연구)

  • 최세규;유승룡;김생빈
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.4
    • /
    • pp.141-148
    • /
    • 1996
  • The pulished works on Accelerated Curing Effect were generally performed around from 1960 to 1970th century for 18 to 24 hours - total curing periods. It is not possible to define the effect of temperature rise because those results were obtaine mainly by using the manually operated steam-curing tank. Thus, it may not be available to apply those data immediately on the domestic PC wall production line. The testing specimens were made from the standard mix proportion according to those of domestic PC factories to establish a basic data for the Accelerated Curing Effect. The experimental tests were conducted according to the conditions of each sub-curing periods. By comparing the results of compression tests on de-molded and 28-day water-curing specimens, we find that the most effective curing condition to obtain more than the required design strength after 28 day of water curing may be as follows: the presteaming period does not affect seriously and less than$30^{circ}C/hr$- the rate of temperature rise andless than $82^{circ}C$ - maximum temperature are necessary. It seems that post-curing procedure is very important factor to increase the effect of accelerated curing.

Secondhand Smoke Exposure in Commercial Personal Computer Rooms (PC 방 금연구역의 간접흡연 노출)

  • Sohn, Hong-Ji;Oh, Ae-Ri;Kim, Ok-Gum;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.288-293
    • /
    • 2010
  • In this study, exposure to secondhand smoke (SHS) was evaluated in commercial personal computer (PC) rooms with different separation types of non-smoking areas. The particulate matter less than 2.5 ${\mu}m$ ($PM_{2.5}$) level was simultaneously measured by aerosol spectrometers in the non-smoking and smoking areas of these commercial PC rooms. Average $PM_{2.5}$ concentrations in non-smoking and smoking areas were $75\;{\mu}g/m^3$ and $136\;{\mu}g/m^3$, respectively. Although the $PM_{2.5}$ concentrations in non-smoking areas were significantly less than those in smoking areas (p<0.01), the levels still exceeded the US National Ambient Air Quality Standard of $35\;{\mu}g/m^3$. Average $PM_{2.5}$ concentrations in non-smoking areas were not significantly different with regard to area separation type, with $73\;{\mu}g/m^3$ in the no-wall type, $83\;{\mu}g/m^3$ in the wall-type, and $39\;{\mu}g/m^3$ in the separated-floor-type areas (p>0.1). Separation of the non-smoking area thus did not eliminate SHS exposure in commercial PC rooms, regardless of the type of area separation. This study demonstrates that simple separation of non-smoking areas in commercial PC rooms does not protect users from SHS.

Photoconductive Cell Characteristics of CdS Thin Films Grown by Hot-Wall Evaporation Technique (Hot-Wall Evaporation Technique으로 성장된 CdS 박막의 광전도 셀 특성)

  • Shin, Yeong-Jin;Jeong, Tae-Soo;Shin, Hyun-Keel;Kim, Taek-Sung;Jeong, Cheol-Hoon;lee, Hoon;Shin, Yeong-Shin;Rheu, Kee-Soo
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.1
    • /
    • pp.73-77
    • /
    • 1993
  • Hot-wall evaporation technique으로 세라믹 기판 위에 CdS 박막을 성장하였다. 이 때 증발원과 기판의 온도는 각각 570, 40$0^{\circ}C$이고 두께는 3$mu extrm{m}$이었다. 공기 중에서 열처리하여 감도(${\gamma}$), 광전류와 암전류의 비(pc/dc), 최대허용소비전력(MAPD), spectral response 및 응답시간 등을 측정하였다. $550^{\circ}C$, 30분간 열처리한 경우 가장 좋은 광전도 특성을 얻었으며 ${\gamma}$=0.89, pc/cd~104, MAPD: 492mW, rise time이 100ms, decay time이 260ms이었다.

  • PDF

A Study on the Behavior of a Spinning Flexible Disk near a Curved Wall (곡률이 있는 벽면근처에서 고속회전하는 유연디스크의 거동 해석)

  • Lee, Ho-Ryul;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.201-207
    • /
    • 2006
  • Information storage devices have been studied to increase the storage capacity and the data transfer rate as well as to decrease the access time and their physical sizes. Optical information storage devices have been achieved high-capacity by reducing optical spot size remarkably due to the development of Blue-ray technology. Optical information storage devices usually use 1.2mm-thick polycarbonate(PC) media to get high enough stiffness. However, it would be better if we can decrease the thickness of a disk for achieving thinner device while keeping the capacity as large as possible. Decreasing the thickness of the storage media makes it difficult to read and write data because it increases the transverse vibration of the rotating disk due to the interaction with surrounding air and the vibration characteristics of thin flexible disk itself, Therefore, a special design based on the fluid mechanics is required to suppress the transverse vibration of the disk in non-contact manner so that the optical pickup can read/write data successfully. In this study, a curved wall is proposed as a stabilizer to suppress the transverse vibration of a $95{\mu}m$-thick PC disk. The characteristics of disk vibration due to a curved wall have been studied through numerical and experimental analysis from the fluid mechanics point of view. The proposed shapes are possible candidates as stabilizers to suppress the transverse vibration of a flexible disk which rotates at high speed.

  • PDF

Ultraviolet Microscopic Study on Lignin Distribution in the Fiber Cell Wall of BCTMP

  • Yoon, Seung-Lak;Yasuo Kojina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.61-66
    • /
    • 2004
  • Bleached chemithermomechanical pulp (BCTMP) was produced from CTMP of Betula maximowicziana Regel by two staged ozone-hydrogen peroxide bleaching in order to improve the optical properties of high yield pulp. This pulp was used for the evaluation of optical properties improvement, chemical characteristics of lignin in fiber and the relationship between lignin and optical properties in fiber cell wall. Hydrogen peroxide treatment improved the brightness, but the post color number (PC No.). There was little improvement on optical properties by ozone treatment, but this could be improved more by using two staged ozone-hydrogen peroxide bleaching. The hydrogen peroxide treatment did not make any change on chemical characteristics of lignin in cell wall, but by ozone treatment, it was found that the non-aromatic conjugated structure was existed in the surface of cell wall, but this could be removed by hydrogen peroxide treatment in two staged ozone-hydrogen peroxide treatment. Therefore, the optical properties was significantly improved, due to the removal of non-aromatic conjugated structure.

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • v.22 no.4
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.

Bronchoalveolar Lavage of Pneumocystis carinii Pneumonia: Cytological and Ultrastructural Features (Pneumocystis carinii 폐렴의 기관지 폐포세정액: 세포학적 및 전자현미경적 소견)

  • Kwon, Kun-Young;Yun, Cheol-Hee;Kim, Sang-Pyo;Park, Kwan-Kyu;Chang, Eun-Sook
    • The Korean Journal of Cytopathology
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1994
  • The cytological and ultrastructural findings of Pneumocystis carinii(PC) obtained from rats by bronchoalveolar lavage (BAL) are described. All developmental forms of the PC organisms were obtained in the lavage fluid. Papanicolaou stain revealed conglomeration of PC as a foamy cast. The cystic walls of PC were well identified on Gomori's methenamine silver stain. Trophozoites and intracystic bodies were stained by Giemsa and Diff-Quik techniques. Some PC organisms were seen within the alveolar macrophages. Ultrastructurally, the cysts were almost circular in shape, and were nearly devoid of surface tubular extensions. The wall of the cyst was composed of an unit membrane, an intermediate electron lucent layer and an external electron dense layer The cysts frequently contained intracystic bodies, so called sporozoites. Occasionally empty or collapsed cysts with no intracystic bodies, and precysts were found. Trophozoites were variable in size and shape with abundant tubular extensions along the single electron dense pellicle. BAL is a useful method for concentrating the various morphologic forms of PC organisms, and is a rapid diagnostic method for PC pneumonia.

  • PDF

Analytical Study on Seismic Behavior of Precast Concrete Slabs with Different Aspect Ratios (형상비에 따른 프리캐스트 콘크리트 슬래브의 지진 거동에 대한 해석적 연구)

  • Lim, Gyu Seok;Jang, Won Seok;Jeong, Seong-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.103-111
    • /
    • 2024
  • Due to the recent increase in domestic seismic activity and the proliferation of PC structure buildings, there is a pressing need for a fundamental study to develop and revise the design criteria for Half-PC slabs. In this study, we propose criteria for determining the rigid diaphragm based on the aspect ratio of Half-PC slabs and investigate the structural effects based on the presence of chord element installation. This study concluded that Half-PC slabs with an aspect ratio of 3.0 or lower can be designed as rigid diaphragms. When chord elements are installed, it is possible to design Half-PC slabs with an aspect ratio of 4.0 or lower as rigid diaphragms. In addition, the increase in the aspect ratio of the Half-PC slab leads to a decrease in the in-plane stiffness of the structure, confirming that the reduction effect of the maximum displacement in force direction (𝜟max ) due to the increase in wall stiffness is predominantly influenced by flexibility.

A Study on the User Evaluation for Media Form of Virtual Environment (가상환경의 미디어 형식에 대한 사용자 평가 연구)

  • Park, Soo-Been;Yoon, So-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.5
    • /
    • pp.166-174
    • /
    • 2008
  • As the use of virtual environment for decision-making interior or architectural design has been increasingly broaden, the choice of media form-physical, objective properties of a display medium-became and important issue to take into consideration. This research deals with the effects and differences between two types of media for a virtual environment; wall projection screen(120") and PC monitor(17"). In addition, efficient adoption of the two media forms was also proposed in this research. A total of 90 subjects participated in pre-designed three experimental groups(A group: experiment with a wall projection screen, B group: experiment with PC monitor, C group: both) and answer the seating preferences, the presence inventory, and the decision confidence using a simulated virtual restaurant environment. The results are as follows: (1) seating preferences for the tables located in frequent traffic area and near other spaces such as restroom and th kitchen are significantly different by the media form. While there is no significant difference found in seating preferences for most tables except high traffic areas near entrances between the two media. This result demonstrates the effects of media type or screen size on user perception for the areas near structural or interior design elements. (2) The presence measure in this research consist of in this research consist of four factors: 'spatial presence,' 'object presence,' 'positive effects,' and 'the factor of negative effects. 'The mean values of the items involving engagement or interaction in the spatial presence factor and the object presence factor are significantly different by the media form. A higher sense of presence of presence was observed in the wall projection screen. (3) PC monitor condition was shown to provide a higher level of decision confidence. Based on the research finding, conclusions and implications are discussed.

A Study on the History of Technology in Korean Modern Architecture (한국 현대건축의 기술역사에 관한 연구)

  • Jung, In-Ha;Kim, Jin
    • Journal of architectural history
    • /
    • v.9 no.3 s.24
    • /
    • pp.51-69
    • /
    • 2000
  • This study tries to analyze the development of architectural technologies appeared in several tall buildings and large spatial structures from 1955 to 1999 in Korea. We suppose that these buildings represent the development of technology in Korean modern architecture. By the detailed analysis of these buildings, we can arrive at a conclusion as such; During the years 1955-1999, there existed a great changement in the eighties. We can find this fact very well in the domain of structural system and curtain wall system. In large spatial structures, the structural-system of shell and steel truss dome was replaced by that of space frame, space truss and cable truss with membrane. In tall building, the structural system of rigid frame and shear wall was replaced by tubular system, core and outrigger system. Korean architects introduced the aluminum curtain wall in the sixties, but its low technological level caused many problems in reality. Therefore, precast concrete curtain wall appeared from seventies as the main method for an outer wall in tall building. With the augmentation of height after 1980, PC curtain wall was replaced by the aluminum curtain wall of unit type and structural glass wall system. These systems help to stress the transparency in a tall building.

  • PDF