• Title/Summary/Keyword: PC Resin

Search Result 61, Processing Time 0.021 seconds

A PHOTOELASTIC STUDY ON THE STRESS ANALYSIS UNDER MADIBULAR DISTAL-EXTENSION REMOVABLE PARTIAL DENTURE WITH DIFFERENT DESIGN OF THE MAJOR CONNECTOR (주 연결장치의 설계변화에 따른 하악 유리단 국소의치의 광탄성 응력 분석에 관한 연구)

  • Lee, Kyw-Chil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.177-194
    • /
    • 1991
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a distal extension removable partial dentures with three kinds of mandibular major connectors, that is, lingual bar, linguoplate, and swing-lock attachment. A photoelastic model was made of the epoxy resin(PC-1) and hardener(PCH-1) and coated with plastic cement-1 (PC-1) at the lingual surface of the epoxy model and set with three kinds of chrome-cobalt removable partial dentures. A bilateral vertical load of 15kg to the middle portion of the metal bar crossing both the first molars of the right and the left, and a unilateral vertical load of 12.5kg to the right first molar were applied with the use of specially designed loading device and the reflective circular polariscope was used to analyze the photoelastic model under each condition. The following results were obtained : 1. When the bilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 2. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 3. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the termial abutment or adjacent teeth on the non-loaded side showed the least stress distribution in case of swing-lock attachment. 4. When the bilateral vertical load and the unilateral vertical load were applied the swing-lock attachment showed the mildest uniform stress distribution on the edentulous area and the alveolar bone around the abutment teeth.

  • PDF

Analysis of defects caused by halo defects during injection molding (사출성형 중 달무리 현상에 의한 불량에 대한 분석)

  • Lee, Soon-Young;Park, Eun-Min;Kim, Do-Hun;Kim, Yong-Chul;Yang, Chul-Seung;Jin, Gyeong-Min;Kim, Sun-Kyoung
    • Design & Manufacturing
    • /
    • v.13 no.4
    • /
    • pp.57-62
    • /
    • 2019
  • In this study, we investigated the halo surface defection of various phenomenon occurred during the injection molding process which is caused by the thinning of the product thickness and the importance of the appearance. Surface analysis was performed to observe the difference between the surface where defects appeared and the surface which did not appear. Based on these results, we analyzed the phenomenon of halo surface defects was caused by unstable flow of resin generated in injection molding and velocity change of flow front. Furthermore, we will conduct a clear analysis of halo surface defects through observations through optical microscopy and subsequent observations with atomic force microscope. It has been analyzed that halo in PP is due to the rheological difference between the crystalline and amorphous regions while that in PC/ABS is due to shear separation of PC and ABS.

Determination of Synthetic Food Colours by HPLC with Photodiode Array Detector (HPLC를 이용한 타르색소의 분리정량)

  • Yang, Ho-Chul;Heo, Nam-Chil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • A simple, rapid, efficient method is for extraction of 13 synthetic water-soluble food colours (Tartrazine, Amarnth, Indigo carmine, New coccine, Sunset yellow FCF, Allura red AC, Eosine, Fast Green FCF, Brilliant Blue FCF, Erythrosine, Acid red, phloxine, Rose Bengal) by polyamide resin and for their quantitative by high performance liquid chromatography (HPLC). Colours (coal-tar dyes) were extracted with polyamide resin and then determinated by HPLC. The HPLC conditions using a reverse phase partition type column $(Nova-pak\;C_{18})$, photodiode array (PDA) detector and 1% Ammonium acetate / 60% acetonitrile in water as eluent, were acceptable for various kinds of colorants. By the use of the proposed method, a survey of coal-tar dyes was carried out on 20 samples and that were detected $4.76{\sim}133.47\;ppm$.

  • PDF

Synthesis and characterization of PPG-based urethane-modified epoxy resin for enhancing impact resistance of epoxy composite resin (에폭시 복합수지의 내충격성을 향상을 위한 PPG 기반 우레탄 변성 에폭시 합성 및 특성 분석)

  • Hwang, Chiwon;Jeon, Jaehee;Ahn, Dowon;Yu, Youngchang;Lee, Wonjoo
    • Journal of Adhesion and Interface
    • /
    • v.23 no.2
    • /
    • pp.44-52
    • /
    • 2022
  • Epoxy resin has the disadvantage of being easily destroyed by instantaneous impact due to its high crosslinking density despite its high glass transition temperature (Tg) and excellent properties. To compensate for this, in this study, polyol was synthesized by ring opening polymerization of propylene glycol (PPG) diamine, Jeffamine D 2000 and propylene carbonate, and urethane modified epoxy was synthesized using this. The properties of the synthesized urethane modified epoxy were confirmed by FT-IR, H-NMR. To confirm the degree of improvement in impact resistance as an adhesive, a urethane modified epoxy adhesive was prepared by mixing a digylcidyl ether bisphenol A (DGEBA) with curing agent and curing accelerator. Properties test of urethane modified epoxy were shear strength, tensile strength and impact strength. As a result, excellent results were obtained in all test when the ratio of DGEBA : urethane modified epoxy was 8:2.

Investigation of Molding Characteristics in Injection Compression Molding According to Molding Conditions through Birefringence (사출압축성형에서 복굴절을 통한 성형조건에 따른 성형특성 고찰)

  • Lee, Dan Bi;Nam, Yun Hyo;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.193-198
    • /
    • 2014
  • Lens and DVD require high quality of optical property. Conventional injection molded products contain high residual stress and this invokes birefringence since high cavity pressure and high temperature variation are involved in a molding process. Thus these products are often molded by injection compression molding in order to minimize the residual stress through reducing cavity pressure and uniform cavity pressure. In this study, molding parameters affecting molding quality such as property uniformity in injection compression molding were investigated through experiment. Molding quality deviations among the cavities in multi-cavity mold were also studied. Transparent resins, PC and PS were used in this study. Compression gap, compression speed, compression force, and compression delay time for processing variables in injection compression molding were applied in experiment. Compression force, compression delay time, and compression gap significantly affected the optical property of product. The degree of influence of process variable on the product quality was different in different resins. This implies that the optimal operational conditions in injection compression molding existed for each resin according to flow property.

Cellular responses to 3D printed dental resins produced using a manufacturer recommended printer versus a third party printer

  • Beatriz Sona Cardoso;Mariana Brito da Cruz;Joana Faria Marques;Joao Carlos Roque;Joao Paulo Martins;Rodrigo Cordeiro Malheiro;Antonio Duarte da Mata
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.126-138
    • /
    • 2024
  • PURPOSE. The aim of this study was to evaluate the influence of different 3D dental resins, using a manufacturer recommended printer and a third-party printer, on cellular responses of human gingival cells. MATERIALS AND METHODS. Three NextDent resins (Denture 3D+, C&B MFH and Crowntec) were used to produce specimens on printers NextDent 5100 (groups ND, NC and NT, respectively) and Phrozen Sonic Mini 4K (groups PD, PC and PT, respectively). Human gingival fibroblasts were cultured and biocompatibility was evaluated on days 1, 3 and 7. IL-6 and IL-8 concentrations were evaluated at 3 days using ELISA. Surface roughness was evaluated by a contact profilometer. SEM and fluorescence micrographs were analyzed at days 1 and 7. Statistical analyses were performed using SPSS and mean differences were tested using ANOVA and post-hoc Tukey tests (P < .05). RESULTS. There was an increase in cellular viability after 7 days in groups PC and PT, when compared to group PD. ND group resulted in higher concentration of IL-6 when compared to PT group. SEM and fluorescence micrographs showed less adhesion and thinner morphology of fibroblasts from group PD. No significant differences were found regarding surface roughness. CONCLUSION. The use of different printers or resins did not seem to influence surface roughness. NextDent 5100 and Phrozen Sonic Mini 4K produced resins with similar cellular responses in human gingival fibroblasts. However, Denture 3D+ resin resulted in significantly lower biocompatibility, when compared to C&B MFH and Crowntec resins. Further testing is required to support its long-term use, required for complete dentures.

Observation of Castability of Dental DLP 3D Printer Materials (치과용 DLP 3D Printer 가공체의 주조성 관찰)

  • Song, Joon-boo;Park, Yu-jin;Choi, Sung-min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2019
  • Purpose: Recently, the production technology of dental prosthesis using 3D Printer workpeices has been developed. However, the lack of information on the work processes and casting techniques of materials for 3D printing casting is expected to require research. Therefore, in this study, we intend to cast a Dental DLP 3D Printer workpiece, which is being commercialized, to identify its appearance and internal clearance, and to observe its castability. Methods: Castability of the 3D Printer workpiece was evaluated. The specimen is prepared in a cylindrical shape and in a 1 mm thick coping shape. The control specimen is made of wax and the experimental specimen is made of resin using two types of 3D printers. After casting, the appearance of the casting body was observed and the internal clearance of the coping was measured. Results: RP1 and RP2, cylindrical specimens, were partially cast or fin. When coping-type specimens were measured before casting, the internal clearance of PE2 was more accurate than that of PC and PE1. When coping-type specimens were measured after casting, CE1 was the most accurate in occlusal clearance and CE2n was the most accurate in axial clearance. Conclusion: 1. Exterior observations of the casting body indicated casting defects and fins. 2. Internal clearance observations show that the occlusal clearance of the castings is larger after casting, and the axial clearance of the castings is smaller after casting. 3. It is judged that the RP2 specimen is more likely to be applied for casting than the RP1 specimen.

A PHOTOELASTIC STRESS ANALYSIS IN MANDIBULAR DISTAL - EXTENSION REMOVABLE PARTIAL DENTURES WITH VARIOUSLY DESIGNEO INDIRECT RETAINERS (간접유치장치 설계변화에 따른 하악유리단 국소의치의 광탄성 응력분석)

  • Kang, Seung-Jong;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.183-197
    • /
    • 1990
  • The purpose of this study was to analyse the magnitude and distribution of stresses using a Photoelastic model from and distal - extension removable partial dentures With four designed indirect retainers. The designs of the indirect retainers were as follows : Design No. 1 : Aker's clasp on 1st bicuspid with no indirect retainer. Design No. 2 : Aker's clasp on 1st bicuspid with indirect retainer on canine. Design No. 3 : Extension of the reciprocal arm of Aker's clasp toward incisal rest on canine. Design No. 4 : Connection with the indirect retainer as in No. 2 and extension of reciprocal arm of Aker' s clasp. A photoelastic model was made of the epoxy resin(PL - 1) and hardner(PLH - 1) and coated with plastic cement -1(PC -1) at the lingual surface of the epoxy model and set with chrome - cobalt partial dentures. A unilateral vertical load of 10kg to the right 1st molar and a vertical load of 10kg to the middle portion of the metal bar crossing both the 1st molars of the right and left, were applied. With the use of specially designed jig, fixture; loading device and the reflective circular polariscope, we obtained the following results : 1. When the unilateral vertical load and the vertical load of the middle portion of the metal bar were applied, design No. 2, 3 and 4 exhibited the higher stress concentration at the root apices and their surrounding tissues of the primary and secondary abutment teeth. 2. When the unilateral vertical load applied to design No. 2,3 and 4 the root apices of the primary and secondary abutment teeth and their surrounding tissues and the nonloaded side of edentulous area exhibited and even stress distribution. 3. When the vertical load was applied, the stress concentration fringe in the primary and secondary abutment teeth was in the order of No. 1,4,2 and 3. 4. No.1 and 4 exhibited the higher distrorted stress concentration at the primary teeth and the edentulous area in the nonloaded side. 5. No.2 design reduced the stresses at the apices of the alveoli of the primary abutment teeth bilaterally as well as on the crest of the residual ridge on the nonloaded side. 6. No. 2 design exhibited the most favorable stress distribution.

  • PDF

Subhective Symptoms and Work-related Health Risk Factors in Korean Dental Laboratory Technicians (우리 나라 치과 기공사의 신체 자각 증상과 직업 관련 건강 위험 요인)

  • Kim, Woong-Chul;Lee, Se-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.89-112
    • /
    • 2000
  • Although dental laboratory technicians are prone to be exposed to various work-related health hazardous materials such as dusts, chemicals, etc., the prevalence and nature of work-related health problems of them have not been a matter of great concern in the field of occupational health service in Korea. The purpose of the present investigation was to describe a collected profile of subjective health symptoms and their attributable factors in Korean dental laboratory technicians. A questionnaire listing five groups of health symptoms and five health symptom-related factors was mailed to randomly selected 1,900 dental laboratory technicians. Among them, 1,344 dental laboratory technicians filled out the questionnaires and returnde them. Five groups of health symptoms included musculoskeletal symptom, dermal symptoms, respiratory symptoms, eys symptoms, and ear symptoms. Five health symptom-related factors were occupational environment-related health risk factors, work history, health related habits and status, use of personal protective equipment and general characteristics. Detailed parameters of health risk factors were work posture, vibration, and chemical or physical hazards such as dust, fume, vapor, solvent, light, and noise for occupational environment-related factors; work place, area, number of employees, work hours, career, work part, and work load for work history; Broca's index, hours of sleep, eating, smoking, alcohol, exercise, health examination, and self assessed health status for health habits and status; face masks, goggles, and so on for use of personal protective equipment, and; age, sex, marital status, and education for general characteristics. Before the start of main survey, a pilot survey was carried out for validity and reliability tests of the questionnaire. All the data obtained were coded and analyzed with PC/SAS 6.12 program. The prevalence of health symptoms was the highest in musculoskelton (87.3%), and followde by eyes (78.9%), respiratory organs (64.3%), ears (57.8%), and skin (52.2%) in descending order. Statistically significant risk factors by multiple logistic regression analyses were sex, health examination, self assessed health status, and hand/finger posture in musculoskeletal symptoms; sex, self assessed health status, career, acid gas, and hand contact with resin mixture in deraml symptoms; Broka's smoking, exercise, self assessed health status, and face mask in respiratory symptoms; sex, hours of sleep, self assessed health status, work hours, work load, plaster dust, inadequate lighting, and goggle in eys symptoms, and eating, smoking, self assessed health status, and work load in ear symptoms. With the above considerations in mind, prevalence of subjective symptoms among Korean dental laboratory technicians was relatively high, and they were attributable to most of the occupational environment-related factors, work history, use of personal protective equipment, health habits and status, and general characteristics. Particularly, it is suggested that health promotion programs for promoting self- assessed health status and smoking cessation, preventive measures for protection of the female technicians’health, and reducing work load be necessary, since those factors were associated with more than one subjective symptom.

  • PDF

Comparison of biological activities of essential oils from Foeniculum vulgare Mill, Boswellia carteii Birew and Juniperus rigida Sieb. by a supercritical fluid extraction system (초임계 추출 공법을 이용해 회향, 유향 및 노간주나무로부터 분리한 정유 성분의 생리활성 비교)

  • Lee, Hyun-Soo;Mun, Chul-Hyung;Park, Jin-Hong;Kim, Dae-Ho;Yoo, Jae-Eun;Park, Young-Sik;Ryu, Lee-Ha;Choi, Keun-Pyo;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.11 no.2
    • /
    • pp.115-121
    • /
    • 2003
  • Essential oils from Fennel fruit(Foeniculum vulgare Mill), Olibanum resin(Boswellia carteii Birew) and Needl Juniperus stem(Juniperus rigida Sieb.) were extracted by a supercritical fluid extraction system(SFE) and biological activity of each essential oils were observed. SFE technique was applied for the isolation and purification of nonpolar biologically active essential oils from each samples. The quantitative analysis of essential oils was carried out by gas chromatography-mass spectrometer(GC/MS). About 60% of the growth of AGS and A549 cells were inhibited by adding 1.0g/l of the crude essential oils and below 40% was observed by the control. Cytotoxicity on human normal lung cell(HEL299) was scored as $15{\sim}18%$ for the crude essential oils and 12% for control, respectively. It meant that the essential oils were more effective than the control in anti-mutagenecity tested by CHO V79 cells. The effect of the essential oils on the growth of nerve cells, PC12 was observed as follows: The viable cell density was about two times higher than control.