• Title/Summary/Keyword: PAD Response

Search Result 128, Processing Time 0.028 seconds

Analgesic Effects of Triptolide via Peripheral and Central Administration in Rat Model of Inflammatory Orofacial Pain (Triptolide의 말초와 중추투여에 의한 흰 쥐의 안면부 통증경감효과)

  • Kim, Yun-Kyung;Choi, Ja-Hyeong;Lee, Hyun-Jung;Son, Yoo-Jin;Yoon, So-Yeong;Lee, Jung-Hwa;Lee, Min-Kyung
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.424-429
    • /
    • 2015
  • The aim of this study was to investigate whether peripheral or central administration of triptolide is involved in pain modulation in inflammatory orofacial pain. The inflammatory orofacial pain was induced by the injection of 5% formalin into right vibrissa pad of rats. The pain behavioral response was measured the number of grooming or scratching on the orofacial area for 9 successive 5 minutes intervals. Triptolide was administrated into the identified vibrissa pad (12.5, 25, $50{\mu}g/50{\mu}l$) or intracisternal space (0.01, 0.1, $1{\mu}g/10{\mu}l$) 10 min before formalin injection. The nociceptive responses were reduced in the 2nd phase (11~45 minutes), particularly 20, 30 minutes after fomalin injection following administration of triptolide into vibrissa pad (25, $50{\mu}g/50{\mu}l$). Intracisternal ($1{\mu}g/10{\mu}l$) administration of triptolide alleviated the formalin-induced pain behaviors in the 2nd phase, especially 25~40 minutes after formalin injection. Triptolide could be a promising analgesic agent in the treatment of inflammatory orofacial pain.

Structural Evaluation Method to Determination Safe Working Load of Block Handling Lugs (블록 이동용 러그의 안전사용하중 결정에 관한 구조 평가법)

  • O-Hyun Kwon;Joo-Shin Park;Jung-Kwan Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.4
    • /
    • pp.363-371
    • /
    • 2023
  • To construct a ship, blocks of various sizes must be moved and erected . In this process, lugs are used such that they match the block fastening method and various functions suitable for the characteristics of each shipyard facility. The sizes and shapes of the lugs vary depending on the weight and shape of the block structures. The structure is reinforced by welding the doubling pads to compensate for insufficient rigidity around the holes where the shackle is fastened. As for the method of designing lugs according to lifting loading conditions, a simple calculation based on the beam theory and structural analysis using numerical modeling are performed. In the case of the analytical method, a standardized evaluation method must be established because results may differ depending on the type of element and modeling method. The application of this ambiguous methodology may cause serious safety problems during the process of moving and turning-over blocks. In this study , the effects of various parameters are compared and analyzed through numerical structural analysis to determine the modeling conditions and evaluation method that can evaluate the actual structural response of the lug. The modeling technique that represents the plate part and weld bead around the lug hole provides the most realistic behavior results. The modeling results with the same conditions as those of the actual lug where only the weld bead is connected to the main body of the lug, showed a lower ulimated strength compared with the results obtained by applying the MPC load. The two-dimensional shell element is applied to reduce the modeling and analysis time, and a safety working load was verified to be predicted by reducing the thickness of the doubling pad by 85%. The results of the effects of various parameters reviewed in the study are expected to be used as good reference data for the lug design and safe working load prediction.

Using Chlorophyll Fluorescence and Vegetation Indices to Predict the Timing of Nitrogen Demand in Pentas lanceolata

  • Wu, Chun-Wei;Lin, Kuan-Hung;Lee, Ming-Chih;Peng, Yung-Liang;Chou, Ting-Yi;Chang, Yu-Sen
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.845-853
    • /
    • 2015
  • The objective of this study was to predict the timing of nitrogen (N) demand through analyzing chlorophyll fluorescence (ChlF), soil-plant analysis development (SPAD), and normalized difference vegetation index (NDVI), which are positively correlated with foliar N concentration in star cluster (Pentas lanceolata). The plants were grown in potting soil under optimal conditions for 30 d, followed by weekly irrigation with five concentrations (0, 4, 8, 16, and 24 mM) of N for an additional 30 d. These five N application levels corresponded to leaf N concentrations of 2.62, 3.48, 4.00, 4.23, and 4.69%, respectively. We measured 13 morphological and physiological parameters, as well as the responses of these parameters to various N-fertilizer treatments. The general increases in Dickson's quality index (DQI), above-ground dry weight (DW), total DW, flowering rate, ${\Delta}F/Fm$', and qP in response to treatment with 0 to 8 mM N were similar to those of SPAD, NDVI, and Fv/Fm. Consistent and strong correlations ($R^2$= 0.60 to 0.85) were observed between leaf N concentration (%) and SPAD, NDVI, ${\Delta}F/Fm$', and above-ground DW. Validation of leaf S PAD, NDVI, and ${\Delta}F/Fm$' revealed that these vegetation indices are accurate predictors of leaf N concentration that can be used for non-destructive estimation of the proper timing for N-solution irrigation of P. lanceolata. Moreover, irrigation with 8 mM N-fertilizer i s recommended w hen leaf N concentration, SPAD, NVDI, and ${\Delta}F/Fm$' ratios are reduced from their saturation values of 4.00, 50.68, 0.64, and 0.137%, respectively.

The Influence of Restrictions toward Online Game Misbehavior on Users' Emotional States and Intention to Reuse (온라인 게임 부정사용 억제가 감정과 재사용의도에 미치는 영향에 관한 연구)

  • Yang, Chang-Gyu;Huang, Yunchu;Hwang, Yousub
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.3
    • /
    • pp.111-121
    • /
    • 2015
  • Owing to the wide distribution of smart devices, more people enjoy online games. Previous research related to online game has mainly focused on the factors that increase users' intention to reuse and less focused on the influence of restrictions toward online game misbehavior. This study proposes a research model that considers factors that either increase or decrease the use of online games and presents the outcomes. The research results showed that: (1) Restriction policy had no impact on online game users' feelings of pleasure and arousal. (2) Restriction system had negative impact on users' feelings of pleasure and arousal. (3) In an environment where online game misbehavior was restricted, users' emotional states still had positive influence on users' intention to reuse. This research results implies that in order to lead to healthy online game environment, compared to repressive and systematic restriction methods, it is preferable to establish restriction policies that have no negative impact on users' emotional states and to change users' perception through education, so to achieve successful restrictions toward online game misbehavior without jeopardizing revitalization of online game industry.

  • PDF

Analysis of Dynamics Characteristics of Water Injection Pump through the 2D Finite Element (2D 유한요소 해석을 통한 물 분사 펌프의 동특성 분석)

  • Lee, Jong-Myeong;Kim, Yong-Hwi;Kim, Jun-Ho;Choi, Hyeon-Cheol;Choi, Byeong Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.6
    • /
    • pp.462-469
    • /
    • 2014
  • After drilling operations at the offshore plant, crude oil is producted under high pressure. After that time, oil recovery is reduced, because the pressure of the pipe inside is low during the secondary produce. At that time injection sea water at the pipe inside through water injection pump that the device increase to recovery. A variety of mathematical analysis during the detailed design analysis was not made through the dynamics characteristic at the domestic company. 2D model has reliability of analysis results for the uncomplicated model. Also element and the node the number of significantly less than in the 3D model. So, the temporal part is very effective. In addition, depending on the quality of mesh 3D is a real model and FEM model occurs error. So, user needs a lot of skill. In this paper, a 2D finite element analysis was performed through the dynamics analysis and the study model was validated.

Clinical Characteristics of Thermal Injuries Following Free TRAM Flap Breast Reconstruction (확장 광배근 근피판술을 이용한 유방재건술)

  • Park, Jae Hee;Bang, Sa Ik;Kim, Suk Han;Im, So Young;Mun, Goo Hyun;Hyon, Won Sok;Oh, Kap Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.408-415
    • /
    • 2005
  • Following a transverse rectus abdominis musculocutaneous(TRAM) flap breast reconstruction, denervated state of the flap causes the flap skin prone to thermal injury, calling for special attention. During the last 5 years, 69 breast reconstruction with 72 free TRAM flaps, were performed. Four out of thesse 69 patients sustained burn injury. Heat sources were a warm bag(n=2), heating pad(n=1) and warming light (n=1). The thermal injuries occured from 2 days to 3 months following the reconstruction. Three patients healed with conservative treatment, but one patient required debridement and skin graft. Initially 3 out of 4 patients with the burn had shown superficial 2nd degree burn with small blebs or bullae. However all 4 patients healed with scars. Mechanism of burn injuries of the denervated flap are known to be resulting from; 1) loss of behavioral protection due to denervation of flap with flap elevation and transfer, 2) loss of autonomic thermoregulatory control with heat dissipation on skin flap vasculature contributing to susceptibility of burn injury. 3) changes of immunologic and normal inflammatory response increasing thromboxane, and a fall in substance P & NGF (nerve growth factor). Including the abdominal flap donor site, sensory recovery of the reconstructed breast varies individually from 6 month even to 5 years postoperatively. During this period, wound healing is delayed, resulting in easier scarring compared to that observed in the sensate skin. Patients should be carefully informed and warned of possible burn injuries and taught to avoid exposure to heat source at least until 3 years postoperatively.

Clinical Characteristics of Thermal Injuries Following Free TRAM Flap Breast Reconstruction (횡복직근 유리피판술로 유방재건 후 발생한 화상의 임상적 특성)

  • Lee, Paik Kwon;Bae, Joon Sung;Ahn, Sang Tae;Oh, Deuk Young;Rhie, Jong Won;Han, Ki Taik
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.403-407
    • /
    • 2005
  • Following a transverse rectus abdominis musculocutaneous(TRAM) flap breast reconstruction, denervated state of the flap causes the flap skin prone to thermal injury, calling for special attention. During the last 5 years, 69 breast reconstruction with 72 free TRAM flaps, were performed. Four out of thesse 69 patients sustained burn injury. Heat sources were a warm bag(n=2), heating pad(n=1) and warming light (n=1). The thermal injuries occured from 2 days to 3 months following the reconstruction. Three patients healed with conservative treatment, but one patient required debridement and skin graft. Initially 3 out of 4 patients with the burn had shown superficial 2nd degree burn with small blebs or bullae. However all 4 patients healed with scars. Mechanism of burn injuries of the denervated flap are known to be resulting from; 1) loss of behavioral protection due to denervation of flap with flap elevation and transfer, 2) loss of autonomic thermoregulatory control with heat dissipation on skin flap vasculature contributing to susceptibility of burn injury. 3) changes of immunologic and normal inflammatory response increasing thromboxane, and a fall in substance P & NGF (nerve growth factor). Including the abdominal flap donor site, sensory recovery of the reconstructed breast varies individually from 6 month even to 5 years postoperatively. During this period, wound healing is delayed, resulting in easier scarring compared to that observed in the sensate skin. Patients should be carefully informed and warned of possible burn injuries and taught to avoid exposure to heat source at least until 3 years postoperatively.

Differentiation and Labeling of Mouse Preadipocytes for Allogenic Transplantation Study (동종이식 연구를 위한 마우스 지방전구세포의 표지 및 분화 방법의 확립)

  • Kim, In Ok;Kim, Taek Seung;Kim, Mi Hyung;Hyon, Won Sok;Mun, Goo Hyun;Oh, Kap Sung;Bang, Sa Ik
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.533-538
    • /
    • 2005
  • Due to its safety and softness, autologous fat transplantation has been commonly performed for soft tissue correction. However, the injected fat is absorbed resulting in the reduction of volume of the graft by 40-60% within a few months. Thus, there was an attempt to use adipocytes differentiated from preadipocytes in vitro for transplantation. Differentiated adipocytes were biocompatible and matured with gradual volume increase at transplantation site in clinical study(unpublished data). In addition, they did not induce immune rejection in response to nonself lymphocytes in a mixed lymphocyte reaction(MLR)(unpublished data). The purpose of this study is to differentiate mouse preadipocytes following labeling into adipocytes to establish an animal model for allogenic transplantation. Preadipocytes isolated from inguinal and retroperitoneal fat pad of C57BL/6 mice were proliferated with growth medium by passage 3 and differentiated into adipocytes with different culture conditions after labeled with BrdU. At most suitable conditions, above 90% of preadipocytes were differentiated and BrdU labeling did not affect differentiation rate and function of differentiated adipocytes. These results demonstrate that BrdU-labeled adipocytes resulting from this in vitro differentiation protocol are useful for allogenic transplantation study.

The study of the packaging for Ti:LiN$bO_3$optical modulator device and its electrical and optical characteristics (Ti:LiN$bO_3$ 광변조기 소자의 패키징 및 전기.광학적 특성)

  • 윤형도;김성구;이한영;윤대원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.72-78
    • /
    • 1998
  • An optical modulator Ti:LiNbO$_3$optical waveguide and CPW electrode structure were fabricated. The optical modulator was packaged using components such as ferrules, dirmy LN block and glass, vibration and shock absorbption pad, and alumina feeder through processings of pigtailing. Au wire bonding, epoxing, SMA connecting, sealing. The electrical and optical characteristics were measured after packaging. The electrical properties of S$_{21}$ and S$_{11}$ were obtained as 9.8 GHz at -3 dB and -8.9dB at 14.4GHz, respectively. Optical waveguide prepared met requirements for a single mode at a 1550nm wavelength range. Insertion loss was 4.3dB at room temperature after packaging, and was varied 4.3~6.4dB at various temperatures, 5~45$^{\circ}C$. E-O bandwidth measurement showed 3dB optical response at 7.8GHz, which means that it is applicable for 10Gbps optical communicationon

  • PDF

Junction Capacitance Dependence of Response Time for Magnetic Tunnel Junction (터널링 자기저항 소자의 접합면 정전용량에 따른 전기적 응답특성)

  • Park, S.Y.;Choi, Y.B.;Jo, S.C.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.68-72
    • /
    • 2002
  • In this research, the effects of capacitance to the access time were studied at the junction area of tunneling magnetoresistance when these were used as memory devices. These results were obtained by applying electric signal input and magnetic field was not used. We applied bipolar square waves of 1MHz to the MTJ samples to obtain the results and time constant ($\tau$) calculated by observing wave responses utilizing an oscilloscope. And time constant was compared with junction area. Each part of MTJ sample, such as electrical pad, lead and contact area, was modeled as an electrical equivalent circuit based on experimental results. For the 200㎛$\times$200㎛ cell, junction capacitance was 90 pF. Also, measurement and simulation results were compared, which showed those similarity.