Impact of Characteristics of Polymeric Al Coagulants PACl and Alum on Membrane Flux and Fouling of Microfiltration (PACl 및 Alum 응집제 특성이 정밀여과막 투과수량 및 막오염에 미치는 영향)

  • Jin, Yong-Chul;Choi, Yang-Hun;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.231-240
    • /
    • 2011
  • The objectives of this research are to investigate coagulation efficiencies of two coagulants l.e., alum and polyaluminum chloride and to understand effects of the coagulants on membrane fouling in microfiltration. The turbidity of supernatant from alum coagulation was increased with increasing doses whereas the turbidity from PACl coagulation was maintained at the low values. The observed injection volume of PACl for the same removal was approximately 30 percent less than alum, which produced a low sludge volume. The settling velocity of PACl flocs was greater than alum flocs. The results corresponded well with floc size measurements. Flux decline from alum coagulation was significant due in part to small sizes of flocs. At the low dose, alum floc had less specific cake resistance than PACl floc. However, as the dosage was increased, the increases in specific cake resistances of alum was substantial. Alum coagulation pretreatment needs careful operation to reduce membrane fouling by flocs. In general, PACl coagulants were more effective than alum coagulants for pretreatment of membrane processes because PACl showed the better performance in coagulation and membrane fouling.

Chemical Coagulation Treatment Using Alum and PACl in Complex Wastewater (Alum과 PACl을 이용한 응집처리)

  • Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.53-57
    • /
    • 2009
  • In order to treat the complex wastewater containing organic compound and solids, pre-treatment system associated with molecular separation process were investigated. The reductions of COD and turbidity were obtained after coagulation processes using Alum (Aluminium sulfate, $Al_2(SO_4)_2{\cdot}18H_{2}O$) and PACl (poly aluminium chloride as 17% $Al_{2}O_{3}$). The results of study were as follows: using variable dosage of Alum, COD removal was highest at 4,000 mg/l, and the reduction of COD and turbidity was 42% and 92%, respectively. The optimum coagulation would be effective at pH 7.3 than pH 9.0 by the addition of alum at a concentration of 6,000 mg/l and PACl was add at 4.25% in raw complex wastewater with 2,000 mg/l alum at pH 7.3, the reduction of COD was reduced by 32%. But coagulation aid experiments indicated that PACl would be more effective in sludge separation ability than COD removal efficiency.

Comparison of Al(III) and Fe(III) Coagulants for Improving Coagulation Effectiveness in Water Treatment (정수처리 응집효율 개선을 위한 Al(III)염과 Fe(III)염 응집제의 비교)

  • Han, Seung woo;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.325-331
    • /
    • 2015
  • The experimental results of the characteristics of aluminum based and ferric based coagulants for the Nakdong River water showed that the main hydrolysis species contained in alum and $FeCl_3$ are monomeric species of 98% and 93.3%, respectively. The PACl of r=1.2 produced by the addition of base contained 31.2% of polymeric Al species and the PACl of r=2.2 contained 85.0% of polymeric Al species, as showing more polymeric Al species with increasing r value. Coagulation tests using Al(III) and Fe(III) salts coagulants for the Nakdong River water showed that the coagulation effectiveness of turbidity and organic matter was high in the order of $FeCl_3$ > PACl (r=2.2) > PACl (r=1.2) > alum. $FeCl_3$ has showed better flocculation efficiency than Al(III) salts coagulants. In addition, in case of Al(III) coagulants, the Al(III) coagulants of higher basicity, which contained more polymeric Al species, resulted in better coagulation efficiency for both turbidity and organic matter removed. The optimum pH range for all of the coagulants investigated was around pH 7.0 under the experimental pH range of 4.0~9.5. Especially, the highest basicity PACl (r=2.2) and $FeCl_3$ were considered as more appropriate coagulants for the removal of turbidity in the case of raw water exhibiting higher pH.

Addition of Coagulants for Phosphorus Removal from Combined Sewer Overflows (CSOs) (합류식 하수관거 월류수의 인제거를 위한 응집제 투여)

  • Son, Sang-Mi;Jutidamrongphan, Warangkana;Park, Ki-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.295-302
    • /
    • 2012
  • The coagulation of combined sewer overflows ($CSO_{s}$) was investigated by jar-testing with several commercial coagulants. $CSO_{s}$ sample showed different characteristics of coagulation from secondary wastewater with three common coagulants, aluminum sulfate, ferric chloride and polyaluminum chloride (PACl). Jar-tests showed that relatively wide range of optimal SS and T-P removal yielded with alum and ferric chloride compared with cationic polymers, though efficient SS and T-P removal can be achieved with all three coagulants. The decrease of pH was caused by the increase in dosage of aluminum sulfate, ferric chloride and PACl as coagulants. The pH was changed from 7.0 to 4.7 with the dosages of ferric chloride 25 mL/L. Aluminum sulfate revealed pH of 5.0 and PACl was highest pH of 5.4 after dosing of coagulants. The optimal pH to treat $CSO_{s}$ with aluminum sulfate were 6-6.5; with PACl 6-7, and with ferric chloride higher than 7.

Prediction of Turbidity in Treated Water and the Estimation of the Optimum Feed Concentration of Coagulants in Rapid Mixing Process using an Artificial Neural Network Model (인공신경망 모형을 이용한 급속혼화공정에서 적정 응집제 주입농도 결정 및 응집처리후 탁도의 예측)

  • Jeong, Dong-Hwan;Park, Kyoohong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.21-28
    • /
    • 2005
  • The training and prediction modeling using an artificial neural network was implemented to predict the turbidity of treated water as well as to estimate the optimized feed concentration of polyaluminium chloride (PACl) in a water treatment plant. The parameters used in the input layers were pH, temperature, turbidity and alkalinity, while those in output layers were PACl and turbidity of treated water. Levenberg-Marquadt method of feedforward back-propagation perceptron in the neural network toolbox of MATLAB program was used in this study. Correlation coefficients of the training data with the measured data were 0.9997 for PACl and 0.6850 for turbidity and those of the testing data with measured data were 0.9140 for PACl and 0.3828 for turbidity, when four parameters at input layer, 12-12 nodes each at both the first and the second hidden layers, and two parameters(PACl and turbidity) at output layer were used. Although the predictability of PACl was improved, compared to that of the previous studies to use the only coagulant dose as output layer, turbidity in treated water could not be predicted well. Acquisition of more data through several years obtained with the advanced on-line measuring system could make the artificial neural network useful and practical in actual water treatment plants.

Fluoride removal using Alum & PACl in batch & continuous mode with subsequent microfiltration

  • Dubey, Swati;Agarwal, Madhu;Gupta, A.B.
    • Membrane and Water Treatment
    • /
    • v.12 no.2
    • /
    • pp.83-93
    • /
    • 2021
  • In this study, defluoridation efficiency by aluminium sulphate (alum) and polyaluminium chloride (PACl) were compared for recommended Nalgonda dose (100%) and 80% of this dose in both batch and continuous modes. The residual turbidity was found to be higher in case of alum as compared to PACl with 80% dose representing lesser efficient settling of suspensions, which primarily comprise alumino-fluoro complexes that result in high residual aluminium in the treated water and this was confirmed by TEM and Zeta analysis. Moreover, the application of PACl also resulted in much lesser addition to the TDS and also required lesser lime for pH compensation due to its lower acidity. Hence this reduced dose was recommended for defluoridation. It was also observed that in case of alum, residual aluminium in treated water was 0.88 mg/L (100% dose) & 0.72 mg/L (80% dose) and in case of PACl, it was 0.52 mg/L(100% dose) & 0.41 mg/L(80% dose). After subsequent microfiltration, residual aluminium was 0.28 & 0.21 mg/L for 100% & 80% dose respectively and in case of alum and in case of PACl, it was 0.16 & 0.11 for 100% & 80% dose respectively, which conform to the Al standards(<0.2 mg/L).

Effects of Characterization of Polymeric Al(III) Coagulants on Coagulation of Surface Water (고분자성 Al(III) 응집제의 특성이 상수원수의 응집특성에 미치는 영향)

  • Lee, Sun Gi;Han, Seung Woo;Kang, Lim Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.99-105
    • /
    • 1998
  • This research explored the feasibility of preparing and utilizing a preformed polymeric solution of Al(III) for coagulation in water treatment. Slow base(NaOH) injection into supersaturated aluminum chloride solutions did produce high yields of the type of Al polymers useful to water treatment applications. PACl's characteristic analysis showed that the quantity of polymeric Al produced at value of $r(OH_{added}/Al)=2.2$ was 83% of the total aluminum in solution, as showing maximum contents and precipitate was dramatically increased when r was increased above 2.35. And PACl was stable during sitoring period so aging effect was negligible. Results of the coagulation of Nakdong river waters with three PACls showed that the effectiveness of the three coagulants can be considered as r = 2.2 > r = 2.0 > r = 2.35 which are also the order of higher polymeric aluminum contents. Coagulation results for synthetic water exhibited optimum dose of 0.25mM Al, for three PACls, but above optimum dose, r = 2.0 and 2.2 PACl impaired the coagulation and sedimentation of turbidity and humic acid because of the restabilization of particulate. The effect of pH for on coagulation of Nak Dong River water showed that it had much effect turbidity and TOC removal, especially near pH 7. But pH effect was little for turbidity and TOC removal when r = 2.35 PACl was used for coagulation, that PACl had much more precipitates content.

  • PDF

Improvement of Water Treatment Efficiency by Poly Aluminum Chloride Overdosing in High pH Raw Water (폴리염화알루미늄 과량주입에 의한 고(高) pH 원수의 수처리효율 개선)

  • Lim, Jaecheol;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.39-46
    • /
    • 2009
  • A method to improve water treatment efficiency by coagulant overdosing for high pH raw water at a drinking water treatment plant (WTP) which had no pH adjusting facilities was investigated. Poly aluminum chloride (PACl) was used for coagulant, and turbidity removal efficiency was evaluated as a function of PACl dosage increases. pH and turbidity of supernatant of jar-tester were 7.10 and 0.50 NTU respectively, when the turbidity, pH, alkalinity, water temperature, conductivity of raw water were 1.75 NTU, 9.38, 46.5 mg/L, $6.4^{\circ}C$, $400{\mu}s/cm$, respectively. Turbidity of settled water was reduced from 2.18 NTU to 0.28 NTU (87% reduction) when PACl dosage was increased from 16 mg/L to 45 mg/L at a full scale WTP. This can be attributed to the recovery of coagulant efficiency by pH reduction with the increase of coagulant dose, however coagulation efficiency was reduced with the formation of Al(OH)4- by PACl addition at higher pH. Coagulant overdosing was proven to be a rapid and effective method for high pH raw water, which can be applied at drinking WTP.

Anaerobic Digestion Biochemical Sludge Produced from Municipal Sewage Treatment Process (하수처리시설에서 발생된 약품 잉여슬러지의 혐기성 소화 특성)

  • Cho, Sang Sun;Kang, Ho;Lim, Bong Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.561-569
    • /
    • 2014
  • This study was carried out to get the characteristics of anaerobic digestion for chemical/biological sludge produced from municipal sewage treatment plant for phosphorus. Anaerobic mesophilic batch tests showed that the ultimate biodegradability of waste activated sludge showed 31%, PACl sludge 24%, Alum sludge 26%, respectively. At the S/I 1.0, 75% of total biodegradable volatile solids (TBVS) of waste activated sludge was degraded with an initial rapid decay coefficient, k1 of $0.1129day^{-1}$ and 74% of TBVS of PACl sludge with k1 of $0.0998day^{-1}$, and 76% of TBVS of Alum sludge with k1 of $0.1091day^{-1}$ for 20 days. During the operation of SCFMRs, the 3 reactor (Control, PACl, Alum) pH maintained 6.7~7.0 and the reactor alkalinity maintained 1,800~ 2,200 mg/L as $CaCO_3$. The average biogas production rates of SCFMRs fed with PACl sludge and Alum sludge were 0.089 v/v-d and 0.091 v/v-d, respectively, which was 27~28% lower than that of the control (0.124 v/v-d) at an HRT (hydraulic retention times) of 20 days. And the methane content during the operation ranged 70~76% in 3 reactor. The average TVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 19.6% and 19.9%, respectively, at an HRT of 20 days, which showed 4% lower than that of the control (23.8%). The average BVS removal efficiency of SCFMRs fed with PACl sludge and Alum sludge were 25.8% and 26.9%, respectively, at an HRT of 20 days, which was 8~9% lower than that of the control (34.5%).

Changes in the Removal Efficiency of Total Phosphorus by the Basicity of Al(III) Coagulant (Al(III) 응집제의 염기도에 따른 총인 제거효율의 변화)

  • Han, Seung-Woo;Lee, Chul-Hee;Lee, Jae-Kwan;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.229-236
    • /
    • 2012
  • The analysis of Al (III) hydrolysis species with PACls prepared by different basicity showed that mononmeric Al species were reduced while precipitate Al species were increased with an increase in basicity for PACls. In the case of the PACl with 13.6% basicity, monomeric Al species were 81%, polymeric Al (III) species 19%, precipitate Al (III) species was 0%, as showing the dominant monomeric Al species. The PACl with 13.6% basicity showed above 80% of turbidity removal efficiency without any restabilization. In addition, the PACl with 13.6% basicity showed higher organic removal expressed by $UV_{254}$ which was caused by lower coagulation pH. The PACl containing the higher amount of monomeric Al species was the most beneficial for T-P and $PO_{4}-P$ removal.