• Title/Summary/Keyword: PAC 시스템

Search Result 99, Processing Time 0.029 seconds

Using CR System at the Department of Radiation Oncology PACS Evaluation (방사선 종양학과에서 CR System을 이용한 PACS 유용성 평가)

  • Hong, Seung-Il;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.143-149
    • /
    • 2012
  • Today each hospital is trend that change rapidly by up to date, digitization and introducing newest medical treatment equipment. So, we introduce new CR system and supplement film system's shortcoming and PACS, EMR, RTP system's network that is using in hospital harmoniously and accomplish quality improvement of medical treatment and service elevation about business efficiency enlargement and patient Accordingly, we wish to introduce our case that integrate reflex that happen with radiation oncology here upon to PACS using CR system and estimate the availability. We measured that is Gantry, Collimator Star Shot, Light vs. Radiation, HDR QA(Dwell position accuracy) with Medical LINAC(MEVATRON-MX) Then, PACS was implemented on the digital images on the monitor that can be confirmed through the QA. Also, for cooperation with OCS system that is using from present source and impose code that need in treatment in each treatment, did so that Order that connect to network, input to CR may appear, did so that can solve support data mistake (active Pinacle's case supports DICOM3 file from present source but PACS does not support DICOM3 files.) of Pinacle and PACS that is Planning System and look at Planning premier in PACS. All image and data constructed integration to PACS as can refer and conduct premier in Hospital anywhere using CR system. Use Dosimetry IP in Filmless environment and QA's trial such as Light/Radition field size correspondence, gantry rotation axis' accuracy, collimator rotation axis' accuracy, brachy therapy's Dwell position check is available. Business efficiency by decrease and so on of unnecessary human strength consumption was augmented accordingly with session shortening as that integrate premier that is neted with radiation oncology using CR system to PACS. and for the future patient information security is essential.

Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment (소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가)

  • An, Jin-Young;Kwon, Joong-Chun;Kim, Yun-Hak;Jeng, Yoo-Hoon;Kim, Doo-Eon;Ryu, Sun-Ho;Kim, Byung-Woo
    • Clean Technology
    • /
    • v.12 no.2
    • /
    • pp.67-77
    • /
    • 2006
  • A simple dual sludge process, called as $KNR^{(R)}$ (Kwon's Nutrient Removal) system, was developed for small sewage treatment. It is a hybrid system that consists of an UMBR (Upflow multi-layer bioreactor) as anaerobic and anoxic reactor with suspended denitrifier and a post aerobic biofilm reactor, filled with pellet-like media, with attached nitrifier. To evaluate the stability and performance of this system for small sewage treatment, the pilot-scale $KNR^{(R)}$ plant with a treatment capacity of $50m^3/d$ was practically applied to the actual sewage treatment plant, which was under retrofit construction during pilot plant operation, with a capacity of $50m^3/d$ in a small rural community. The HRTs of a UMBR and a post aerobic biofilm reactor were about 4.7 h and 7.2 h, respectively. The temperature in the reactor varied from $18.1^{\circ}C$ to $28.1^{\circ}C$. The pilot plant showed stable performance even though the pilot plant had been the severe fluctuation of influent flow rate and BOD/N ratio. During a whole period of this study, average concentrations of $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, and TP in the final effluent obtained from this system were 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, and 0.87/0.17 mg/L (with/without poly aluminium chloride(PAC)), which corresponded to a removal efficiency of 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, and 55.4/90.3%, respectively. Excess sludge production rates were $0.026kg-DS/m^3$-sewage and 0.220 kg-DS/kg-BOD lower 1.9 to 3.8 times than those in activated sludge based system such as $A_2O$ and Bardenpho.

  • PDF

A study of recognition of public health center members to usefulness of PACS system (보건소 직원의 PACS 시스템 유용성에 대한 인식 연구)

  • Hwang, Kwan-Young;Na, Baeg-Ju;Lee, Moo-Sik;Lee, Jin-Yong;Hong, Jee-Young;Bae, Seok-Hwan;Yoo, Se-Jong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.992-995
    • /
    • 2010
  • 본 연구는 기존의 필름 운영체계에서 PACS 운영체계로 전환 시 업무 변화에 따른 보건소 구성원 간의 인식을 조사하고 이들이 가지고 있는 새로운 업무에 대한 저항감을 줄여 새로운 시스템 도입에 적극적으로 적응할 수 있도록 하여 업무의 효율성을 높일 수 있는 기초 자료를 제공하고자 시행하였다. 연구기간은 2009년 6월1일부터 2009년 12월 16일까지이며 연구방법은 대전, 충남북에 소재하고 있는 필름운영체계에서 PACS 체계로 바뀐 보건소의 의사, 방사선사, 간호사, 기타 직종을 대상으로 하였으며 70부의 설문이 분석에 사용되었다. 임상적 유용성 인식은 방사선사(2.8) > 의사(2.7) > 간호사(2.4) > 기타(2.0)로 모든 직종이 향상된 것으로 인식하고 있었으며 PACS 가 필름시스템 보다 임상적으로 사용자 편리서, 접근 용이성 등이 모두 우수하며 임상적으로 유용하다고 답했다. 업무변화 및 효율성 인식은 방사선사(3.2) > 간호사(2.0) > 의사(1.988) > 기타(1.983) 순으로 직종별 차이를 보여 PACS 운영이후 업무가 효율적으로 변화되었다고 인식하고 있었다. 진료 및 근무환경 인식은 방사선사(3.6) > 의사(3.2) > 간호사(3.1) > 기타(3.0) 순으로 진료 및 근무환경이 향상되었다고 답했다. 교육적절성에 관한 인식은 기타(3.5) >간호사(3.0) > 의사(2.8) > 방사선사(2.5) 순으로 직종별 차이를 보였다. 적응 및 만족도 인식에서는 방사선사(2.9) > 기타(1.7) > 간호사(1.6) > 의사(1.5) 순으로 직종별 차이를 보였으며 PACS 운영이후 사용자의 적응도와 만족도가 높다는 것을 알 수가 있었다. 병원정보시스템의 핵심인 PACS 도입과 같은 보건소정보화 과정에서의 보건소 구성원의 인식을 알아본 결과, 임상적 유용성 인식, 교육 적절성에 관한 인식에서는 근무 년 수가 적을수록, 유용성이 높다고 했으며, 업무 변화 및 효율성 인식, 진료 및 근무환경 인식, 적응 및 만족도 의식에서는 근무 연수가 길수록 유용성이 높다고 인식하고 있었다. 성별에 따른 임상적 유용성 인식과 업무 변화 및 효율성 인식에서는 남자가 여자보다 유용하다고 인식하고 있었다. 연령별 차이에 따른 임상적 유용성 인식, 업무 변화 및 효율성 인식, 진료 및 근무 환경 인식은 40대 이상에서 높다고 인식하였다. PACS 도입으로 인해 보건소 구성원의 거부반응과 같은 저항감이나 부담감, 소극적 참여의지 등의 태도나 인식이 예상되었으나 연구 결과 대체적으로 모두 긍정적으로 인식하였으며 PACS가 보건소 구성원들에게 기존 필름체계를 대체할 수 있는 수단으로 유용하게 인식하고 있었다. 다만 본 연구결과는 향후 새로운 PACS 도입 시 성공적인 운영을 위해 직종에 따른 정보 제공 및 맞춤형 훈련 교육이 필요함을 시사하고 있다.

  • PDF

Fuzzy-based Segmentation Algorithm for Brain Images (퍼지기반의 두뇌영상 영역분할 알고리듬)

  • Lee, Hyo-Jong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.12
    • /
    • pp.102-107
    • /
    • 2009
  • As technology gets developed, medical equipments are also modernized and leading-edge systems, such as PACS become popular. Many scientists noticed importance of medical image processing technology. Technique of region segmentation is the first step of digital medical image processing. Segmentation technique helps doctors to find out abnormal symptoms early, such as tumors, edema, and necrotic tissue, and helps to diagnoses correctly. Segmentation of white matter, gray matter and CSF of a brain image is very crucial part. However, the segmentation is not easy due to ambiguous boundaries and inhomogeneous physical characteristics. The rate of incorrect segmentation is high because of these difficulties. Fuzzy-based segmentation algorithms are robust to even ambiguous boundaries. In this paper a modified Fuzzy-based segmentation algorithm is proposed to handle the noise of MR scanners. A proposed algorithm requires minimal computations of mean and variance of neighbor pixels to adjust a new neighbor list. With the addition of minimal compuation, the modified FCM(mFCM) lowers the rate of incorrect clustering below 30% approximately compared the traditional FCM.

Sewage Treatment Using Electric Field Pretreatment and Metal Membrane Microfiltration Process (전기장 전처리 및 금속 정밀여과 공정을 이용한 하수처리)

  • Jung, Jongtae;Kim, Jongoh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.15-21
    • /
    • 2007
  • This study was investigated to evaluate the effect of electric fields application for the reduction of membrane fouling, the inactivation of microorganisms and the enhancement of particle coagulation in microfiltration/coagulation. Cumulative permeate in the case with electric field treatment showed high value compared to the case without electric field. Particularly, the increase of HRT (Hydraulic retention time) showed the increase of cumulative permeate as well as the decrease of total resistance. By electric field treatment, the amount of small particle size less than 100 ${\mu}m$ is increased and the survival fraction is reduced by the increase of electric field intensity. This may be attributed to the cleavage of particle or cytological destruction resulting from the inactivation of microorganism. Coagulant dosage of PAC compared with no electric field application could also be saved about 75% for the 95% of turbidity removal at 10 kV/cm.

  • PDF

THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES (다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구)

  • Choi, Nam-Ki;Cho, Seong-Hoon;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • The objective of this study was to compare the shear bond strengths of five dentin adhesive systems cured with three different light curing sources. Seventy five noncarious permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), G-Bond (GB). And three light curing unit systems were used: Elipar Free light 2(LED), OptiLux 501 (Halogen), Flipo (PAC). For the shear bonding test, the labial and lingual surfaces of permanent teeth were used. To obtain a flat dentin surface, the labial and lingual surfaces of the teeth were sanded on SiO2 with number 600 grit and then divided into 15 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. When cured with Freelight 2, the shear bond strength of SM was significantly higher than that of PL, GB (p<0.05), whereas no significant difference was found among those of any other bonding agents. 2. When cured with Optilux 501, the shear bond strength of SM was significantly higher than those of any other bonding agents (p<0.05), whereas no singnificant difference was found among those of andy other bonding agents. 3. When cured with Flipo, the shear bond strength of SM was significantly higher than those of SB, SE, GB (p<0.05), whereas no significant differences was found among those of any other bonding agents. 4. For comparison according to three different light cure unit system, except SB and GB, each three dentin bonding agents showed no significant difference. For SB, only Freelight 2 was significantly higher than the others, with no significant difference between Optilux 501 and Flip. For GB, Statistically significant difference was found only between Freelight and Flipo.

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

Evaluation of High Flux Combined with Pretreatment Process for Application of Decentralized Water Supply System with Ceramic Membrane (세라믹 분리막의 분산형 용수공급 시스템 적용을 위한 전처리 연계공정의 고플럭스 평가)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.61-72
    • /
    • 2018
  • In this study, applicability of the decentralized water supply system were investigated by the high flux evaluation using ceramic membrane with combined pretreatment process. A) filtration process increased the transmembrane pressure of 1.4 kPa and 89.5 kPa on 2 and $5m^3/m^2{\cdot}d$ of filtration flux, respectively, the physical backwashing recovery rate were less than 28.6%. The (B) Coag./Floc. - Sedi. combined process with 4 mg / L of A-PAC showed that the transmembrane pressure increased to within 6 kPa, the physical backwashing recovery rate was over 37.9 % higher than (A) Filtration process. (C) Coag./Floc. combined process showed an increase of transmembrane pressure compared with (B) Coag./Floc. - Sedi. combined process, physical backwashing recovery rate was over 84%. As a result of the membrane fouling analysis using the resistance in series model, the combined pretreatment process showed that the cake resistance (Rc) was more than 92% at membrane filtration flux of $2m^3/m^2{\cdot}d$. In the (C) Coag./Floc. combined process, cake resistance(Rc) was over 86% on high flux conditions. The coagulation floc contained in influent was removed by the membrane, and the cake layer formed with the removed floc was identified as reversible fouling resistance which could be recovered by physical backwashing. The decentralized water supply system, which has the limitation of site area and installation space, is considered to could be operation of high flux of ceramic membrane by applying (C) Coag./Floc. combined process without sedimentation process.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF