• Title/Summary/Keyword: P300 latency

Search Result 49, Processing Time 0.025 seconds

Analysis of Motor Performance and P300 during Serial Task Performance according to the Type of Cue (시열과제 수행 시 신호형태에 따른 운동수행력과 P300 분석)

  • Lee, Myoung-Hee;Kim, Myung-Chul;Park, Ju-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.281-287
    • /
    • 2013
  • PURPOSE: The study was designed to investigate the effects of visual, auditory, and visuoauditory cues on simple Serial Task Performance in heaithy adults. METHODS: Sixty-three right-handed heaithy adults without history of neurological dysfunction were participated. A modified version of the Serial Reaction Time Task (SRTT) using five blocks of perceptual motor sequences was administered. The blocked paradigm consisted of the five blocks with randomly repeated 8 digit sequences with 5 repetition. Three types of sensory cue were employed: visual cue, auditory cue and visuoauditory cue. All subjects were assigned to press the matched botton as quickly and accurately as possible, when one of 8 stimulations was presented(one, two, three, four, five, six, seven, eight). The reaction time, accuracy, and P300 latency were measured during serial task performance. The mean reaction time(ms), accuracy(%), and P300 latency(ms) were compared between three types of cue using ANOVA. RESULTS: The reaction time to auditory cue was significantly longer than visual and visuoauditory cues(p<.001). And accuracy to auditory cue was significantly lower than visual and visuoauditory cues(p<.001). All P300 latency(at Fz, Cz, Pz) were significantly longer than to visual and visuoauditory cues(p<.05). CONCLUSION: It is suggested that type of cues influence in choice reaction. These data may helpful in designing not only effective motor learning training programs for healthy persons but also reeducation programs for patients with neurological dysfunction.

A Study on the Auditory ERP measured in Sasang Constitutionally classified Three Groups (사상체질별 사건관련전위(ERP) 측정 연구 -청각 자극을 중심으로-)

  • Kim, Jeong-Ho;Song, Jeong-Mo;Kim, Lak-Hyung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.2
    • /
    • pp.65-70
    • /
    • 2004
  • 1. Objectives This study is to find the difference of ERP in Sasang Constitutional groups 2. Methods Auditory ERP were measured in 32 healthy males. Latency and amplitude of P300 component were analysed. 3. Results The latency of ERP P300 component in Taeumin group was more extended than that in other groups. It was significant statistically. The Amplitude of ERP P300 component in Soyahgin group was more extended than that in other groups. 4. Conclusions This results suggest that ERP measuring could be used in Sasang Constitutional diagnosis.

  • PDF

Comparison of P300 between Schizophrenia and Bipolar Disorder (정신분열병과 양극성 장애의 P300 비교)

  • Park, In-Joon;Jeong, Hee-Yeon;Kwon, Young-Joon
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.123-130
    • /
    • 2001
  • Objective : Asymmetries in evoked potential P300 topography of schizophrenia and bipolar disorder are still controversial. The purpose of this study was to examine the difference in P300 topography between schizophrenia and bipolar disorder. Method : P300 was recorded from 16 schizophrenic, 15 bipolar manic, and 16 control subjects. All were right-handed. Subjects silently counted target stimuli(2.0kHz) among trains of standard stimuli(1.0kHz). Averages were constructed from brain responses to target stimuli. Results : 1) Schizophrenics displayed significantly smaller peak amplitude of P300 over Cz, Pz, T3 than controls. 2) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than bipolar manics. 3) Schizophrenics displayed significantly smaller peak amplitude of P300 over T3 than their T4. 4) Schizophrenics displayed significantly delayed latency of P300 over T3 than bipolar manics. 5) Schizophrenics displayed significantly delayed latency of P300 over T3 than their T4. Conclusions : Left-sided P300 abnormality, especially left superior temporal gyrus, in schizophrenics relative to bipolar manics and controls suggests that psychophysiological cause of schizophrenia and bipolar disorder is different and P300 asymmetry is specific to the psychophysiological cause of schizophrenia.

  • PDF

Analysis of P300 Related Target Choice in Oddball Paradigm

  • Jang, Yun-Seok;Ryu, Soo-Ah;Park, Kyu-Chil
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.125-128
    • /
    • 2011
  • P300 component of the event-related brain potential (ERP) reflects fundamental cognitive processes. The P300 components have been employed in a wide variety of theoretical, empirical, and clinical applications. In oddball paradigm for eliciting P300, we need standard stimuli and target stimuli. Firstly, designated stimuli are presented to subjects. Nextly, a chosen target stimulus is presented. In this paper, we elicited the P300 components with experiment that the subjects select a chosen target stimulus. Therefore, we measured the P300 components to be related choice of the target stimuli. The experimental results and the P300 components to be analyzed were presented.

Correlation Between the Prolongation of P300 Latency during Sleep Deprivation and Personality Variables (수면박탈에 의한 P300 잠복기 연장과 성격요소와의 연관성)

  • Lee, Heon-Jeong;Jeon, Hye-Yeon;Kim, Yong-Ku;Suh, Kwang-Yoon;Kim, Leen
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.1
    • /
    • pp.61-66
    • /
    • 2003
  • Objectives: The purpose of this study is to investigate the relationship between the extent of prolongation in P300 latency by sleep deprivation and personality variables. Methods: Eighteen healthy male college students participated in this study. Subjects remained awake for 37 hours under continuous surveillance. In the morning and evening of two consecutive study days, P300 was checked four times. MMPI and STAI-T were checked in the morning of the first day. The 18 subjects were divided into two groups according to their extent of P300 prolongation by sleep deprivation: Group A consisted of short P300 latency prolonged subjects, and group B of long latency prolonged subjects. The MMPI profiles and STAI-T scores of these two groups were compared. Results: Group B showed significantly higher scores in the Mf subscale (t=-2.16, df=16, p=0.046) and Pa subscale (t=-2.61, df=16, p=0.019) than group A. Group B also showed higher F subscale scores at a marginally significant level (t=-2.11, df=16, p=0.052). Conclusion: These results suggest that subjects with higher scores in F, Mf, and Pa subscales tend to have delayed cognitive process and decreased efficiency of mental process by sleep deprivation. It can be hypothesized that individuals who are sensitive, passive, dependent, and easily projecting are susceptible to the deterioration of cognitive function by total sleep deprivation.

  • PDF

Convergent Analysis of Old People Eye Movement Training on Change of Cognitive Ability (안구 운동이 노인의 인지능력 변화에 미치는 융합적 분석)

  • Bae, Seahyun;Kim, Kyung-Yoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.5
    • /
    • pp.121-127
    • /
    • 2018
  • The objective of the present study was to investigate the effect of eye movement on cognitive ability using Mini-Mental State Examination for Dementia Screening (MMSE-DS) and the amplitude and latency of P300 from event-related potentials after 55 elderly participants were randomly stratified into the saccadic eye movement (SEM) group and the smooth pursuit eye movement (SPEM) group, and performed eye movement for 4 weeks. As a result, P300 amplitude significantly increased and P300 latency significantly shortened in the SEM and SPEM groups. MMSE-DS showed a significant increase in both groups; upon comparing the groups, the SEM group showed a significant difference in orientation and the SPEM group in attention. In conclusion, it is thought that SEM and SPEM can improve and maintain the cognitive ability of the elderly and may be used as therapeutic tools for dementia prevention and mild dementia.

The P300 Source Localization in the Patients with Obsessive-Compulsive Disorder using the LORETA Imaging and SPM (강박장애에서 LORETA 영상을 이용한 P300 국소원의 통계적 분석)

  • Park, Sung-Kun;Choi, Jung-Seok;Yu, Soh-Young;Lee, Bo Reom;Kang, Seung-Suk;Roh, Kyu Sik;Ha, Tae-Hyun;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.10 no.2
    • /
    • pp.168-176
    • /
    • 2003
  • Objectives:We investigated the characteristics of P300 generators in obsessive-compulsive disorder(OCD) patients by using voxel-based statistical parametric mapping of current density images. Methods:P300 generators, produced by a rare target tone of 1500Hz under a frequent non-target tone of 1,000Hz, were measured in 15 right-handed OCD patients and 15 controls. Low Resolution Electromagnetic Tomography(LORETA), using a realistic head model of the boundary element method based on individual MRI, was applied to the 128-channel EEG. Statistical parametric mapping(SPM) was applied for the statistical analysis. Results:We found that both groups had the mean current density of P300 in the parietal, temporal and prefrontal lobe. There was a trend for decreased current density in the prefrontal area in OCD patients. The statistical comparison showed current density increase in the supraparietal area, a statistically significant longer P300 latency and a trend for reduced P300 amplitude in OCD patients. Conclusion:It suggests that P300 source of both groups exists in multiple brain regions at the same time. And both groups had no statistically significant differences in the current density of P300 except for increased current density in the supraparietal area in OCD patients. But, considering the statistically significant longer P300 latency, a trend for reduced P300 amplitude and relative mean current density reduction in the prefrontal area in OCD patients, this study suggests that the frontal lobe may have a reduced normal inhibitory process in OCD patients.

  • PDF

Interval estimate of physiological fluctuation of peak latency of ERP waveform based on a limited number of single sweep records

  • Nishida, Shigeto;Nakamura, Masatoshi;Suwazono, Shugo;Honda, Manabu;Nagamine, Takashi;Shibasaki, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.1.1-5
    • /
    • 1994
  • In the single sweep record of event-related potential (ERP), the peak latency of P300, which is one of the most prominent positive peaks in the ERP record, might fluctuate according to the recording conditions. The fluctuation of the peak latency (measurement fluctuation) is the summation of the fluctuation caused by physiological factor (physiological fluctuation) and one by noise of background EEG (noise fluctuation). We propsed a method for estimating the interval of the physiological fluctuation based on a limited number of single sweep records. The noise fluctuation was estimated by using the relationship between the signal-to-noise (SN) ratio and the noise fluctuation based on the P300 model and the background EEG model. The interval estimate of the physiological fluctuation were obtained by subtracting the interval estimate of the noise fluctuation from that of the measurement fluctuation. The proposed method was tested by using simulation data of ERP and applied to actual ERP and data of normal subjects, and gave satisfactory results.

  • PDF

Event-related Potentials of Pre- and Post-Hemodialysis in Patients with Chronic Renal Failure (만성신부전 환자에서 혈액투석 전후의 P300 인지유발전위검사)

  • Bae, Jae-Chun;Lee, Sang-Moo
    • Annals of Clinical Neurophysiology
    • /
    • v.3 no.2
    • /
    • pp.136-142
    • /
    • 2001
  • Background : Nervous system dysfunction is a major complication of end stage renal disease. Although severe neurologic symptoms are partially or completely reversed by adequate hemodialysis, even optimally dialyzed patients will usually not return to normal neurocognitive function. To investigate the influence of chronic renal failure and hemodialysis on higher cognitive function electrophysiologically, we studied auditory P300 event-related potentials in 14 hemodialysis patients and 14 age- and sex-matched normal healthy controls. Methods : The subjects consisted of 14 patients(M: 6, F: 8) with chronic renal failure(CRF) for 1 to 10 years and 14 age- and sex-matched healthy controls(M: 5, F: 9). For the reliability of study, patients with diabetes mellitus, abnormal brain CT findings, or low mini-mental state score(below 20) were excluded. Event related potentials(ERPs) for hemodialysis patients were performed at pre- and post-hemodialysis. To obtain ERPs, subjects underwent 2-tone auditory discrimination test(oddball paradigm). Results : Although the age(control: $48.79{\pm}10.31years$, CRF: $51.21{\pm}7.61years$) and mini-mental state score(control: $27.00{\pm}1.71points$, predialysis CRF: $25.07{\pm}3.58points$) were not different in normal control and CRF groups significantly(P>0.05), P300 latencies at Cz(control: $288.11{\pm}17.36msec$, predialysis CRF: $332.35{\pm}42.34msec$) were significantly delayed(P<0.05)and the duration of Trail making test A was significantly prolonged(control: $64.2{\pm}24.2sec$, CRF: $118.9{\pm}101sec$) in CRF group. P300 latencies between pre- and post-hemodialysis CRF patients(predialysis CRF: $332.35{\pm}42.34msec$, postdialysis CRF: $325.82{\pm}38.69msec$) were not significantly different. The P300 latency was not related with the duration of CRF(Spearman's correlation test, r=0.25, P>0.05) and the frequency of hemodialysis(Spearman's correlation test, r=0.28, P>0.05). Conclusions : From these results, we suggest that P300 latency is valuable in evaluating cognitive brain dysfunction in patients with CRF and hemodialysis does not have a significant effect on cognitive brain dysfunction in patients with CRF.

  • PDF

Auditory and Visual P300 in ADHD Children with Higher and Lower IQ : Pilot Study

  • Wang, Sheng-Min;Jeon, Yang-Whan;Han, Sang-Ick;Park, E-Jin
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.22 no.4
    • /
    • pp.211-218
    • /
    • 2011
  • Objectives : Intellectual impairment in children with attention-deficit hyperactivity disorder (ADHD) is often associated with relatively severe cognitive dysfunction. This study was designed to investigate cognitive function using auditory and visual event-related potential P300 in children with ADHD with relatively higher and lower IQ. Methods : A total of 20 children aged 6-12 years with DSM-IV-TR diagnosis of ADHD-combined type were recruited. For 10 children with lower IQ (${\leq}$100) and 10 children with higher IQ (>100), auditory and visual P300 using oddball paradigm (target 0.2, standard 0.8, in probability) were employed. Results : No significant differences were found in P300 amplitude and latency between ADHD children with higher and lower IQ in both modalities. However, auditory P300 amplitude in the right parietal area (P8 electrode) was negatively correlated with verbal IQ in ADHD subjects (R=-.50, p<.05). Visual P300 amplitude in the left parietal area (P3 electrode) was positively correlated with performance IQ in ADHD subjects (R=.57, p<.01). Conclusion : This study suggests intellectual impairment, as evidenced by lower IQ, could not be associated with cognitive dysfunction reflected in event-related potential P300 in ADHD children. However, cognitive function reflected in intellectual subcomponents and P300 might be processed in a stimulus modality-specific and asymmetric pattern.