• 제목/요약/키워드: P.C.B

검색결과 8,302건 처리시간 0.039초

벼의 자연통풍건조에 있어서 통풍량이 건조에 미치는 영향에 관한 연구 (A Study on Effects of Air-delivery Rate upon Drying Rough Rice with Unheated Air.)

  • 이상우;정창주
    • 한국농공학회지
    • /
    • 제16권1호
    • /
    • pp.3293-3301
    • /
    • 1974
  • An experimental work was conducted by using a laboratory-made model dryer to investigate the effect of the rate of natural forced-air on the drying rate of rough rice which was deposited in the deep-bed. The dryer consisted of 8 cylinderical containers with grain holding screen at their bottoms, each of which having 30cm in diameter and 15cm in height. The containers were sacked vertically with keeping them air-tight by using paper tape during dryer operation. Two separate layers of containers were operated in the same time to have two replications. The moisture contents of grains within each bins after predetermined period of dryer operation were determined indirectly by measuring the weight of the individual containers. The air-rates were maintained at 6 levels, or 5, 8, 10, 15, 18 and 20 millimenters of static head of water. The roomair conditions during dryer operation were maintained in the range of 10-l5$^{\circ}C$ in temperature and 40-60% in relative humidity. The results of the study are summarized as follows: 1. Drying characteristics of the grains in the bottom layers were approximately the same regardless of airdelivery rates, giving the average drying rate as about 0.35 percent per hour after 40-hour drying period, during which moisture content (w. b.) reduced from 24 percent to about 10 percent. 2. After about 40-hour drying period, the mean drying rates increased from 0.163 percent per hour to 0.263 percent per hour as air-flow rates increased from 5mm to 87.16mm of static head of water. In the same time, the moisture differences of grains between lower and upper layers varied from 12.7 percent at the air rate of 5mm of water head to 7.5 percent at the air-flow rate of 20mn of water head. Thus, the greater the air-flow rate was, the more overall improvement in drying performance was. Additionally, from the result of ineffectiveness of drying grain positioned at 70cm depth or above by the air rate of 5mm of static head of water it may be suggested in practical application that the height of grain deposit would be maintained adequately within the limits of air-rates that may be actually delivered. 3. Drying after layer-turning operation was continued for about 30 hours to test the effectiveness of reducing moisture differences in the thick layers. As a result of this layer-turning operation, moisture distribution through layers approached to narrow ranges, giving the moisture range as about 7 percent at air-flow rate of 5mm head of water, about 3 percent at 10mm head about 2 percent at 15mm head, and less than 1 percent at 20mm head. In addition, from the desirable results that drying rate was rapid in the lower layers and dully in the upper layers, layer-turning operation may be very effective in natural air drying with deep-layer grain deposit, especially when the forced air was kept in low rate. 4. Even though the high rate of air delivery is very desirable for deep-layer natural-air drying of rough rice, it can be happened that the required air delivery rate could not be attained because of limitation of power source available on farms. To give a guide line for the practical application, the power required to perform the drying with the specified air rate was analyzed for different sizes of drying bin and is given in Table (5). If a farmer selects a motor of which size is 1 or {{{{1 { 1} over {2 } }}}} H.P. and air-delivery rate which ranges from 8~10mm of head, the diameter of grain bin may be suggested to choose about 2.4m, also power tiller or other moderate size of prime motor may be recommended when the diameter of grain bin is about 5.0m or more for about 120cm grain deposit.

  • PDF

암의 조기발견을 위한 CT촬영에서의 임상적 효능과 방사선위해에 대한 고찰 (Review of the Radiation Risk and Clinical Efficacy Associated with Computed Tomography Cancer Screening)

  • 김현자
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.214-227
    • /
    • 2013
  • MDCT의 등장과 함께 병적 증상이 없는 개인이 조기검진을 위해 CT검사를 하는 예가 꾸준히 증가하고 있다. 이러한 검사의 임상적 효용성과 방사선에 의한 암 발생위험에 대한 여러 가지 논란을 살펴보았다. 1. 저선량흉부CT(LDCT)를 이용한 폐암의 조기 검진 효용성을 보기 위해 설계된 무작위배정대조검사(randomized controlled trial)인 NLST(National Lung Screening Trial)의 분석 결과, CT선별검사가 선별검사를 하지 않은 그룹의 사망률 1.67%를 1.33%로, 20% (p=0.004) 감소시키는 것으로 나타났다. CT선별검사군에서 양성결과를 보인 사람의 96.4%는 위양성(false-positive)이었다. 그리고 방사선에 의한 폐암의 ERR (excess radiation risk)은 다른 고형암과는 달리 나이와 함께 감소하지 않으며, 더욱이 흡연 위험과 방사선 위험이 상승작용을 하여 폐암 검진 대상인 고위험군에게 더욱 위험할 수 있는 것으로 평가되었다. 따라서 방사선에 의한 위험이 NLST에서 관측한 이득을 상쇄할 수도 있다. 아직은 최적의 전략이 확립되지 않은 상태이므로 임상에서 광범위하게 적용하기에는 한계가 있다. 2. 대장CT검사(CT colonography)는 10 mm보다 큰 용종의 검출에는 정확도가 뛰어나지만 이보다 작은 경우에는 민감도와 특이도가 급격히 감소하고, 용종이 발견되어 제거하고자 하는 경우 다시 기존의 대장내시경을 이용해야 하는 불편함이 있다. 현재 대장CT검사 1회 시행의 평균유효선량은 약 8-10 $mS{\nu}$로 보고되어, 만약 이 검사가 많은 사람들을 대상으로 일상적으로 행해지면 공중보건에 영향을 미칠 수 있다. 따라서 집단검진 방법으로 정착하기 위해서 는 용종 크기 6-10 mm 범위에서 높은 민감도와 특이도를 확립하고, 하제를 사용하지 않는 방법을 개발하여야 하며, 선량을 더 감소시킬 수 있는 최적화된 전략을 세워 표준화하여야만 한다. 3. 전신CT검사는 그 효용성이 검증된 선행연구가 없는 상태이다. 이 검사는 약 90%의 검사자들에게서 최소한 하나 이상의 이상소견을 확인하였지만 그 중 약 2%만이 임상적으로 중요한 질환으로 판명되었다. 전신CT검사 1회 시행으로 인한 평균유효선량은 약 12 $mS{\nu}$이며 45세부터 75세까지 매년 검사를 받는 경우 LAR (lifetime attributable risk)이 1.9%로 보고되었다. 현재 의학계의 어떤 단체도 이 검사를 권고하고 있지 않다. 현재까지 CT선별검사는 정당화에 대한 충분한 논의를 위해 심도 있는 다양한 연구가 필요하며 최적화된 프로토콜이 확립된 후 이용하는 것이 바람직하다.

벼 생육중기(生育中期) 피발생(發生) 원인(原因) 및 이들의 밀도(密度)에 따른 쌀수량(收量) 감소(減少) (Reason of Late Establishment of Barnyardgrass and Their Density Effects on Rice Yield Loss)

  • 성기영;이상복;구연충;송득영;허일봉;김윤선
    • 한국잡초학회지
    • /
    • 제17권4호
    • /
    • pp.439-444
    • /
    • 1997
  • 벼 생육중기(生育中期)에 발생하는 피의 발생(發生) 원인(原因)을 구명(究明)하고 이들의 발생밀도(發生密度)에 따른 쌀수량(收量) 감소정도(減少程度)를 추정(推定)하기 위해 1996년과 1997년의 2년에 걸쳐 시험(試驗) 조사(調査)한 결과 1. 1998년과 1992년 5만정보(町步) 이상(以上) 사용된 제초제(除草劑)들 중 이앙후(移秧後) 5일 이후에 처리하는 일발처리(一發處理) 제초제(除草劑)가 1988년 6%에서 1992년 52.5%로 급격히 증가(增加)하고 있었으며, 이들 일발처리제(一發處理劑)들의 제초제의 성분중(成分中)에서 피를 방제(防除)하는 제초제(除草劑) 성분(成分)은 그 함량(含量)이 1988년에 비해 1992년에는 41.7~87.5%에 지나지 않음을 알 수 있었다. 2. 기계이앙재배시(機械移秧栽培時) 벼 생육중기(生育中期)에 발생하여 벼에 영향을 주는 피는 거의 재생(再生) 피로 5월 10일 담수직파재배(湛水直播栽培)의 경우 0.5주/$m^2$, 5월 23일 기계이앙재배시(機械移秧栽培時)의 경우 2.0주/$m^2$, 그리고 6월 9일 만기(晩期) 기계이앙재배시(機械移秧栽培時)의 경우 13.3주/$m^2$가 발생(發生)하였다. 3. 1996년 및 1997년 5월 23일 기계이앙답(機械移秧畓)에서 조사한 피 발생주수(發生株數)에 따른 쌀수량(收量)의 관계를 보면 1996년에는 y=543.3 4.7x, r=0.9039 로 고도의 유의성을 갖고 직선적(直線的)으로 감소하고 있었으며, 피1주당 쌀수량(收量) 감소(減少)는 대략 0.9%정도이었다. 반면에 1997년에는 y=515.8 10.4x+0.066$x^2$, $R^2$=0.9532로 고도의 유의성을 갖는 이차(二次)항식을 보여주고 있으며, 피발생수에 따른 쌀수량 감소정도가 1996년에 비해 더 크게 나타났다. 회귀식에 의하면 피발생수에 따른 이론적(理論的) 쌀수량(收量) 감소(減少)는 피 1주/$m^2$일 때 2%이었으며, 피 5주/$m^2$일 때 10%, 피 10주/$m^2$일 때 19%, 피 20주/$m^2$일 때 35%, 피 50주/$m^2$일 때 69%, 피 80주/$m^2$일 때 79% 감소(減少)한 것으로 추정(推定)되었다.

  • PDF

Ad-Hoc 네트워크에서 보조헤더를 이용한 개선된 클러스터 기반의 라우팅 프로토콜 (An Improved CBRP using Secondary Header in Ad-Hoc network)

  • 허태성
    • 융합신호처리학회논문지
    • /
    • 제9권1호
    • /
    • pp.31-38
    • /
    • 2008
  • Ad-Hoc 네트워크는 군사적인 목적으로 시작되었으며, 네트워크 인프라 구조가 없거나, 네트워크 인프라의 설치가 용이하지 않거나, 전쟁 및 분쟁지역, 재해나 재난에 의해 통신 시설을 설치하기 어려운 지역에서 비상 통신 수단으로 사용되고 있다. 그러나 Ad-Hoc 네트워크는 기존의 유선망과 비교하여 대역폭이 좁고 신호간의 간섭이 상대적으로 심하여 망 형상이 수시로 변경될 수 있다. 따라서 기존의 라우팅 알고리즘을 적용할 수 없으며, 새로운 라우팅 알고리즘 연구가 활발히 이루어지고 있다. 본 연구는 기존에 제안된 라우팅 알고리즘 중 클러스터에 헤더(주헤더)를 두어 관리하는 클러스터 기반의 라우팅 프로토콜(CBRP)에서 클러스터 내의 주헤더 노드를 제외한 모든 노드가 주헤더 통신을 의존함으로써 발생하는 주헤더 이상시의 문제점을 최소화하기 위해 클러스터 내에 보조헤더를 두어 클러스터 및 클러스터내의 모든 노드를 관리하는 방안(ACBRP)을 제안한다. 보조헤더 역할은 주헤더가 비정상적으로 되어 노드들 간의 송수신에 더 이상 참가할 수 없을 경우, 별도의 주헤더 재선출 과정 없이 보조헤더가 즉시 주헤더로 교체되어 기존의 주헤더 역할을 담당한다. 이는 CBRP에서 클러스터 주헤더 노드가 클러스터 밖으로 이동하거나, 비정상적인 상태가 되어 다른 주헤더 노드를 선출해야 하는 부담을 효과적으로 줄이고, 이 때 통신 중인 모든 노드는 통신의 중단 없이 계속적으로 라우팅을 유지할 수 있다. 따라서 본 연구가 기존의 CBRP에 비해 효율적인 통신을 할 수 있으며, 모의실험을 통해 ACBRP의 성능 평가를 위한 주헤더 재선출을 위한 비용 계산을 위해 필요한 데이터 값들을 측정하고, 기존의 CBRP와 비교 평가하여, 타당성을 확인하였다.(12.7%), 폐렴 4례 (7.2%), 기관지확장증 4례 (7.2%), 무기폐 4례 (7.2%)의 순으로 많았다.경우보다 높은 2.0 unit/mL의 농도에서 알파-갈 항원결정인자가 제거되는 양상을 보였다. 걸론: 돼지의 대동맥 판막 조직과 심낭 조직의 알파-갈 항원결정인자는 eriffonia simplicifolia의 동종렉틴 B4를 사용한 면역조직형광염색에서 잘 염색되었으며 이를 알파-갈락토시다아제를 사용하여 제거하였을 때 각각 1.0 unit/mL, 2.0 unit/mL 농도의 녹색콩 알파-갈락토시다아제를 $4^{\circ}C$, pH 6.5의 조건에서 24시간 반응시켰을 때 효과적으로 상당량 제거할 수 있었다. 향후 돼지의 판막조직 및 심낭조직으로 만드는 조직판막의 내구성 증대에 대표적인 동물 면역항원인 알파-갈 항원결정인자의 제거가 유용한 도구가 될 수 있을 것이며 앞으로 알파-갈락토시다아제로 처리한 돼지의 조직판막에 대한 인간혈장의 항-갈 항체 및 항-갈 단클론항체를 이용한 직접적인 면역학적 연구가 필요하다.광학거울 (Fine-grade optical mirror)을 이 부위에 넣고 반사시야에서 수술적 처치를 시행할 것을 주장했으나, 수술시의 출혈등에 의한 명료시야의 확보에 문제점이 있어 널리 시행되지 않았다. Saito(1971)등은 Sinus tympani의 접근방법으로서 종래의 중이강내에서 접근방식 (Tympani approach) 보다 유양동을 통한 접근(mastoid approach)이 보다 편리하고 확실한 방법일 것이라는 생각으로 42개의 측두골에 대한 미세해부학적 계측을 실시하였다. 그러나 연구결과에서 그는 Sinus tympani의 상부는 안면신경과 지나치게 가까운 거리에 있어

  • PDF

화이버 기관지경 검사의 임상적 고찰 (A Clinical Study on Fiberoptic Bronchoscopy)

  • 이상기;홍영호;권평중;김중환
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1981년도 제15차 학술대회연제순서 및 초록
    • /
    • pp.3.2-3
    • /
    • 1981
  • 1978년 2월부터 1981년 2월까지의 3년간 중앙대학교이비인후과에서 화이버기관지경 검사를 시행한 예중 화이버기관지경에 의한 진단이나, 병리조직학적 진단이 확실한 55례에 대하여 통계학적으로 분석 검토하여 다음과 같은 결과를 얻었기에 문헌적 고찰과 함께 보고하는 바이다. 1) 성별로는 남자 41명, 여자 14명으로 3 : 1로 남자가 더 많았다. 2) 연령별로는 50∼59세 군이 가장 많은 분포를 보였으며 (15례, 27.2%), 40대, 60대, 70대 사이에서는 커다란 차이점이 없음을 발견하였다. 3) 성별로는 가장 많은 빈도를 보인 50대 에서는 남자 12명 여자 3명으로 남녀간에 4 : 1의 비율을 보였다. 4) 주소는 기침(52%), 혈담(25%), 호홉곤란(23.6%), 흉통(18%), 가슴답답(9%)의 순으로 많았다. 5) 기관지 흡입물을 그람 염색하여 세균이 발견되지 않은 것이 33례(60%)로 가장 많았고, 그람양성구균 2례 (3.6%), 그람음성구균 2례 (3.6%), 그람양성간상균 1례 (1.8%), 그람음성간상균 2례 (3.6%), 혼합균이 15례 (27.2%)이고 혼합균중 그람음성간상균이 13예로서 가장 많았다. 6) 기관지 흡입물의 배양결과는 28례 (50.9%)에서, 자라지 않았고, 알파용혈성 연쇄상구균 10례 (18.2%), 나이세리아속 7례 (12.7%), 크레브시엘라 2례(3.6%) 슈도모나스 2례 (3.6%)이었고, 혼합균은 6례 (10.9%)이고 혼합균중 알파용혈성 연쇄상구균이 6례로서 가장 많았다. 7) 임상적, 검사실성적, 조직적, 기관지경검사에 의해 얻은 진단에 의하면 기관지암 21례 (38.1%), 폐결핵8례 (14.5%), 늑막염 3례 (5.4%), 기관지염 7례 (12.7%), 폐렴 4례 (7.2%), 기관지확장증 4례 (7.2%), 무기폐 4례 (7.2%)의 순으로 많았다.경우보다 높은 2.0 unit/mL의 농도에서 알파-갈 항원결정인자가 제거되는 양상을 보였다. 걸론: 돼지의 대동맥 판막 조직과 심낭 조직의 알파-갈 항원결정인자는 eriffonia simplicifolia의 동종렉틴 B4를 사용한 면역조직형광염색에서 잘 염색되었으며 이를 알파-갈락토시다아제를 사용하여 제거하였을 때 각각 1.0 unit/mL, 2.0 unit/mL 농도의 녹색콩 알파-갈락토시다아제를 $4^{\circ}C$, pH 6.5의 조건에서 24시간 반응시켰을 때 효과적으로 상당량 제거할 수 있었다. 향후 돼지의 판막조직 및 심낭조직으로 만드는 조직판막의 내구성 증대에 대표적인 동물 면역항원인 알파-갈 항원결정인자의 제거가 유용한 도구가 될 수 있을 것이며 앞으로 알파-갈락토시다아제로 처리한 돼지의 조직판막에 대한 인간혈장의 항-갈 항체 및 항-갈 단클론항체를 이용한 직접적인 면역학적 연구가 필요하다.광학거울 (Fine-grade optical mirror)을 이 부위에 넣고 반사시야에서 수술적 처치를 시행할 것을 주장했으나, 수술시의 출혈등에 의한 명료시야의 확보에 문제점이 있어 널리 시행되지 않았다. Saito(1971)등은 Sinus tympani의 접근방법으로서 종래의 중이강내에서 접근방식 (Tympani approach) 보다 유양동을 통한 접근(mastoid approach)이 보다 편리하고 확실한 방법일 것이라는 생각으로 42개의 측두골에 대한 미세해부학적 계측을 실시하였다. 그러나 연구결과에서 그는 Sinus tympani의 상부는 안면신경과 지나치게 가까운 거리에 있어 접근이 용이하지 않았고 후부는 이낭(Otic capsule)에서 발생한 중치밀골(Hard compact bone)로 되어 있으며 안면신경 과 후반규관 사이가 협소하여 수술시 micro-drill burr로서 제거하기가 용이치 않다

  • PDF

유채 지방산조성 개량육종에 관한 연구 제21보 지방산조성 개량품종 보급지역에서의 유질과 금후대책 (Breeding for Improvement of Fatty Acid Composition in Rapeseed XXI. Oil Quality of Fatty Acid Improved Varieties in Cheju Area and Future Production Strategy)

  • 이정일;정동희;류수노
    • 한국작물학회지
    • /
    • 제39권2호
    • /
    • pp.165-170
    • /
    • 1994
  • 유채 지방산조성개량 및 무독박 성분개량육종의 성과로 13년전부터 무에루진산 양질품종을 장여보급한 제주도산 유채가 에루진산 함량이 높아 식용유로의 이용이 어렵게 됨에 따라 '92년산 정부수매유채종자와 '93년산 유채의 포장등숙중 시료의 에루진산 함량을 분석, 그 원인을 추적확인함과 동시에 금후의 유채 연구방향을 재정립하고자 이 시험을 수행하였다. 그 결과를 요약하면 1. 제주도 '92년산 정부수매유채는 에루진산 평균 함량에서 전체평균 47.7% 함유되어 있어 유채 유의 국제품질규격의 에루진산 함량 3∼5% 보다 10배나 높으므로 식용유로는 부적한 것으로 판단되었음. 2. 제주도 '93년산 유채의 농가포장 등숙중 시료를 채취, 분석한 결과 포장에 따라 에루진산이 최저 25%로부터 48.5%까지 평균 37% 함유하고 있어 제주도의 농가포장에서는 무에루진산 장여품종이 재배되지 않음이 확인되었음. 3. 제주도에는 중국산 유채와 캐나다산 제유용 유채종실원료가 도입되어 있는바 중국산은 46.6%의 고함유 에루진산 원료였고 캐나다산은 50%인 것과 4% 에루진산을 함유한 원료가 도입되어 있었음. 4. '92 정부수매유채가 '93 포장농가유채보다 에루진산 함량이 훨씬 높고 고함량 에루진산의 외국산유채 도입이 되고 있는 점으로 미루어 값싼 외국산 고에루진산 도입유채가 농가수매유채에 포함되었을 가능성이 있음. 5. 제주도산 유채는 품질로나 경영적인 면에서 경쟁력을 갖출 가능성이 없고 무에루진산 성분개량 품종의 수용에 무관심하므로 현재의 제주도 대상 유채육종은 중단하고 남부지역의 구조개선 2모작답을 대상으로 한 대형기계화 유채재배 적응품종육성으로 방향을 전환함이 바람직하다.tters of western interests, but "health".gs. Notable economic benefit has been achieved.d. 평가를 하고자 하며 기계적 특성과 관능적 특성간의 상호 관련성에 대하여 연구를 계속하고자 한다.았다. 6. 강남콩 전체가루 (13%, db)의 아밀로그래프에 의한 호화는 시료 모두 최고 점도를 보이지 않았고 가열중 점도는 계속 증가하였으며 시료 A가 가장 높은 점도를 보였고 시료 B와 C는 비슷한 경향을 보였다.첨가하여 제조한 마요네즈는 색을 제외하고는 모든 항목에서 표준 마요네즈와 유의적인 차이를 보이지 않았다. 반면에, 난황을 전혀 첨가하지 않고 5%의 Bovine Plasma만으로 제조한 마요네즈는 표준 마요네즈와 비교했을 때 다소 강한 기름냄새와 기름맛, 난황이 첨가되지 않아 색에 대한 기호도의 저하 등 관능적인 면에서 전반적으로 낮은 결과를 보였다.sim}30$명 편성, 현장 학습으로 수업 진행, 수업 시 이론과 실습의 3:1 비율 운영, 절대 평가에 의한 합격여부 판정 등에 대한 요구가 있었다. 따라서 사회의 변화를 반영하고 교사의 현장 요구를 적극 수용한 프로그램 개발이 이루어져야 할 것이다. 넷째, 연수자의 일반적 특성 변인에 따른 만족도 차이를 분석한 결과, 연수 기관이 유의미한 변수로 작용하였다. 즉, 어느 연수 기관에서 연수를 받았느냐에 따라 연수에 대한 만족도가 다르게 나타났다(p<.05). 즉 교과교육을 가장 많이 개설하고 운영하였던 기관에서 만족도가 가장 높았다. 따라서 현직 교사들의 요구가 많았던 교과교육에 대한 교과 개설이 확대된 표준화된 자격연수 프로그램 개발되어야

  • PDF

지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 - (Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.128-137
    • /
    • 2002
  • 개발된 알루히트를 이용하여 지하수 이용 열교환기를 개발하였다. 시작기는 600mm, 700mm 알루히트 19개의 끝을 U자 용접을 하여 지하수가 직렬흐름이 되도록 2가지로 제작하였다. 성능시험은 개방된 공간에서 지하수 유량과 공기양의 변화를 주면서 상온에서 실시하였다. 1. 시작기의 열전달 계수는 33~156(W/m2℃) 범위로 나타나 설계가정 값에 잘 일치하는 것으로 판단되었다. 2. 열전달 면적이 증가할수록, 지하수 입·출구의 온도 차이가 클수록, 공기의 입·출구 온도 차이가 클수록, 또 송풍량이 증가할수록 에너지 전달량이 증가하였다. 3. 지하수 입·출구 온도 차이가 6℃ 이고 송풍량이 6,000m3/h일 때 전달 열용량은 6,825W였으며, 공기의 입·출구 온도 차이는 25.8℃에서 23.2℃로 -2.6℃의 강화 효과가 있었고, 대류열전달계수는 88.5W/m2℃ 였다. 4. 지하수 입·출구 온도 차이가 2℃ 이고 송풍량이 4,000m3/h일 때 전달 열용량은 2,625W으로 작았지만, 공기의 입·출구 온도 차이는 27℃에서 22.5℃로 -4.5℃의 강화 효과가 있었고, 대류열전달계수는 33.6W/m2℃였다. 5. 시작기 I, II, III의 전달 열용량 데이터 각각의 상관계수 R2은 0.9141, 0.8935, 0.9393이었으며, 공기유량이 6,000m3/h, 5,000m3/h, 4,000m3/h일 때 각각의 데이터 상관계수 R2은 0.9513, 0.9414, 0.9003으로 신뢰할 수 있었다.

지하수 이용을 위한 열교환기 개발. I - 냉각핀의 설계제작 - (Development of heat exchanger by the utilization of underground water. I - Design for plat fin tube -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.119-127
    • /
    • 2002
  • 지하수의 열(15℃)을 농업시설의 난방과 냉방에 사용하기 위하여, 관에 종방향으로 부착되는 plat fin tube 형 알루미늄(Al 6063) 열교환기를 개발하여 알루히트(의장등록 : 0247164)로 명명하였다. 열교환 핀을 관에 종방향으로 배치하여 송풍과 대류에 유체 흐름저항을 최소화 하였으며, 핀표면에 돌기를 만들어 결로와 fouling factor를 감소시켰다. 1. 알루히트의 제원은 관 내경 0.03m, 외경 0.036m, 두께 0.003m이며, 냉각핀의 두께 0.0012m, 핀 길이 0.032m로 하였다. 2. 단위 길이당 관 외부의 전열면적은 1.3946m2이며, 관내부 전열면적은 0.0942m2였고, 내외면적비 Ra = 14.805였다. 3. 핀의 길이 0.032m로 하였을 때, 핀의 효율이 93%정도인 것으로 나타났으며, 핀두께 0.0012m는 h𝛿/k<0.2를 만족하여 적합한 것으로 판단된다. 4. 알루히트의 온수 방열 성능실험에서 열매체의 온도가 높고 유량이 많을수록 방열 열량이 많은 것으로 나타났고, 열매체의 온도 60℃, 유량 10 𝑙/min일 때 방열열량은 504kJ/h·m 였으며, 80℃, 40 𝑙/min일 때는 방열열량이 6,048kJ/h·m로 나타났다. 5. 방열성능에서 각각의 열매체 온도간 상관계수 $R^2_1=0.9898$, 유량간 상관계수 $R^2_2=0.9721$로 실험 데이터를 신뢰할 수 있었다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

원발성 간암의 국소 방사선치료 시 선량반응 관계 (Dose Response Relationship in Local Radiotherapy for Hepatocellular Carcinoma)

  • 박희철;성진실;한광협;전재윤;문영명;송재석;서창옥
    • Radiation Oncology Journal
    • /
    • 제19권2호
    • /
    • pp.118-126
    • /
    • 2001
  • 목적 : 본 연구에서는 원발성 간암의 국소 방사선치료 시 조사선량을 높여준 것이 종양의 반응의 향상을 유도하였는지 분석하고자 하였다. 또한, 저선량을 조사하였던 환자들과 고선량을 조사하였던 환자들의 종양의 반응 및 부작용과 이에 영향을 미치는 인자들을 분석함으로써 향후 적절한 조사선량 범위를 결정하는데 유용한 기준을 제시하고자 하였다. 대상 및 방법 : 대상 환자의 선정 기준은 방사선치료의 과거력이 없는 경우, 간외전이가 없는 경우, 간경변증의 정도가 Child's class A 또는 B군인 경우, 종양이 전체 간 용적의 2/3를 넘지 않는 경우, 전신수행도가 ECOG 3기 이상으로 악화되지 않은 경우로 하였다. 1992년 1월부터 2000년 3월까지 원발성 간암에 국소 방사선치료를 시행 받은 환자들 중 158명이 연구 대상에 포함되었다. 조사영역은 종양과 주변 부위 $2\~3\;cm$를 포함하였고 일일 1.8 Gy씩 주 5회 조사되었다. 방사선치료 전과 종료 후 $4\~6$주째의 컴퓨터 단층 촬영 영상 및 자기 공명 영상, 간동맥 혈관 촬영 영상 등을 이용하여 조사영역 내의 종양의 반응을 평가하였다. 주 1회 혈액 검사를 시행하여 말초 혈액 혈구수 및 간기능을 관찰하였다. 치료의 종료 후 체중 증가, 복수, 간종대 등의 소견을 관찰하였고 4주와 8주에 간기능 검사를 시행하였다. 위장관계의 부작용은 상부위장관 내시경을 시행하여 확인하였다. 종양의 관해 정도에 따라 반응군과 비반응군으로 구분한 후 조사선량의 분포를 통계적으로 분석하였다. 또한, 연구대상을 조사선량에 따라 세 군으로 분류하고 종양의 반응과 임상적 특성을 분석하였다. 결과 : 종양의 반응은 106명이 부분 관해를 보여서 반응군의 비율은 $67.1\%$이었다. 완전 관해는 없었다. 종양이 $50\%$ 이하로 감소된 경우가 41명$(25.9\%)$, 종양의 진행을 보인 경우가 11명$(7\%)$이었다. 반응군의 평균 조사선량은 $50.1{\pm}6.6\;Gy$이었고 비반응군의 평균 조사선량은 $44.3{\pm}9.0\;Gy$로 통계적으로 의미 있는 차이를 보였다. 다변량 분석에서도 조사선량이 p-value 0.001로 유일하게 의미 있는 인자로 나타났다. 종양의 반응률은 조사선량이 40 Gy 미만인 군에서 $29.2\%$, 40 Gy에서 50 Gy사이인 군에서 $68.6\%$, 50 Gy를 넘는 환자 군에서 $77.1\%$로 나타났다. 종양의 크기는 40 Gy 미만인 군에서 $9.8{\pm}2.6\;cm$, 40 Gy에서 50 Gy사이인 군에서 $9.8{\pm}2.6\;cm$, 50 Gy를 넘는 환자 군에서 $8.3{\pm}3.2\;cm$로 고선량을 조사한 군에서 작았다. 간문맥 혈전증은 각각 $66.7\%,\;64.7\%,\;37.3\%$에서 양성으로 50 Gy를 넘는 선량이 조사된 군에서 상대적으로 간문맥 혈전증의 양성률이 낮았다. 방사선 간염, 십이지장의 궤양은 조사선량을 증가시킬수록 증가하는 경향을 나타내었다. 경미한 정도의 복수가 발생하거나 전형적인 방사선 간염의 발생, 위장관계의 염증 등이 치료 전 간경변증이 심할수록 현저히 많이 발생하는 경향을 보였다. 결론 : 원발성 간암에서 국소 방사선치료를 시행하는 경우 고선량이 조사될수록 반응군의 비율이 증가하는 선량반응 관계가 성립함을 확인할 수 있었다. 고선량이 조사될수록 대상 환자의 종양의 크기가 작았고 간문맥 혈전증의 비율도 적었는데 이는 병기가 낮은 경우 완치를 목표로 오히려 고선량을 투여하는 경향 때문으로 생각되었다. 조사선량이 50 Gy를 넘는 경우 조사선량의 증가에 따른 반응률의 향상이 현저하지 않은 반면 방사선 간염의 발생은 간경변증의 정도에 크게 영향을 받는다는 점을 고려할 때, 조사선량의 증가는 반드시 치료를 받는 대상 환자의 간기능과 간경변증의 정도 등을 고려하여 조심스럽게 진행되어야 할 것으로 생각된다.

  • PDF