• 제목/요약/키워드: P. A. 덕트

검색결과 39건 처리시간 0.035초

회전하는 사각덕트 유로에서 벽면 유출홀에 따른 열전달 특성 변화( I ) -회전수 변화에 따른 영향 - (Change of Heat Transfer Characteristics in a Rotating Channel of Square Duct at Wall with Bleed Holes ( I ) - Effects of Rotation Speed -)

  • 김상인;김경민;이동현;전윤흥;조형희
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.898-906
    • /
    • 2005
  • The present study has been conducted to investigate convective heat/mass transfer in the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5mm and its spacing is ( p/d:4.9) about five times of hole diameter. Exit mass flow rate through bleed holes is $10\%$ of the main mass flow rate and relation number is changed form 0.0 to 0.4. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy The cooling performance is influenced by exit mass flow rate through bleed holes and Coriolis force of rotating channel for fixed Reynolds number. The heat transfer on the leading surface is decreased due to Coriolis force. However the total heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding.

회전하는 사각덕트 유로에서 벽면 유출홀에 따른 열전달 특성 변화( ll ) -유출유량 변화에 따른 영향 - (Change of Heat Transfer Characteristics in a Rotating Channel of . Square Duct at Wall with Bleed Holes ( II ) - Effects of Exit Mass Flow Rate -)

  • 김상인;김경민;이동현;전윤흥;조형희
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.907-913
    • /
    • 2005
  • The present study has been conducted to investigate convective heat/mass transfer in the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5mm and its spacing is ( p/d:4.9) about five times of hole diameter. Exit mass flow rate through bleed holes is $0\%,\;10\%\;and\;20\%$ of the main mass flow rate respectively. rotation number is fixed 0.2. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The cooling performance is influenced by exit mass flow rate through bleed holes and Coriolis force of rotating channel for fixed Reynolds number. The heat transfer on the leading surface is decreased due to Coriolis force. However the total heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding.

화력 발전용 보일러 Duct/Fan 시스템의 진동현상에 대한 연구 : Inlet Vortex에 의한 과대진동 사례 (A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers: Inlet Vortex Induced Excessive Vibration)

  • 김철홍;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.82-87
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF

거칠기 형상이 마찰 계수와 열전달에 미치는 영향 (Effects of Rib Geometries on the Friction Factors and Heat Transfer in the Channel)

  • 안수환;손강필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.241-247
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at e/De=0.0476, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.

  • PDF

채널유동에서 거친벽면이 열전달에 미치는 효과 (Effects of Rough Surfaces on Heat Transfer in Channel Flow)

  • 안수환
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.30-35
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with one wall roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to-height ratio, and aspect ratio of channel width to height are fixed at $e/D_e=0.0476$, P/e=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicate that the triangular type rib has a substantially higher efficiency index than any other ones in the range we studied.

  • PDF

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

초음속 유입 유동 조건에 따른 공동을 포함한 덕트 내 초음속 연소 현상에 관한 실험적 연구 (Experimental Study on Supersonic Combustion Phenomena in the Cavity Duct by the Supersonic Inflow Conditions)

  • 정은주;정인석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.209-219
    • /
    • 2006
  • The supersonic combustion experiments are carried out using T3 free-piston shock tunnel. Different shock tube fill pressures have various inflow conditions. $15^{\circ}$ inclined hydrogen fuel injection is located before the cavity. Oblique shock is generated at the trailing edge of the cavity and reflects off the top and bottom wall. For non-reacting flow, static pressures in low equivalence ratio are similar to those in no fuel injection. As equivalence ratio is increased, static pressures are increased in the duct. In the similar equivalence ratio, static pressures are increased when total enthalpy is decreased. For reacting flow, the flame is occurred near the cavity. The combustion is weak locally in the middle of the duct. The up and down pressure distribution in the duct means that the supersonic combustion is generated.

  • PDF

냉각유로 내 곡관부 및 유로의 회전이 압력강하에 미치는 영향 (Pressure Drop Characteristics in a Coolant Passage With Turning Region and Rotation)

  • 김경민;조형희
    • 한국유체기계학회 논문집
    • /
    • 제10권2호
    • /
    • pp.32-40
    • /
    • 2007
  • The present study investigated local pressure drop in a rotating smooth square duct with turning region. The duct has a hydraulic diameter $(D_h)$ of 26.7mm and a divider wall of 6.0mm or $0.225D_h$. The distance between the tip of the divider and the outer wall of the duct is $1.0D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000, and the rotation number (Ro) is varied from 0.0 to 0.20. The pressure coefficient distribution $(C_p)$, the friction factor (f) and the thermal performance $({\eta})$ are presented on the leading, the trailing and the outer surfaces. It is found that the curvature of the $180^{\circ}-turn$ produces Dean vortices that cause the high pressure drop in the turning region. The duct rotation results in the pressure coefficient discrepancy between the leading and trailing surfaces. That is, the high pressure values appear on the trailing surface in the first-pass and on the leading and side surfaces in the second-pass. As the rotation number increases, the pressure discrepancy enlarges. In the fuming region, a pair of the Dean vortices in the stationary case transform into one large asymmetric vortex cell, and then the pressure drop characteristics also change.

거친 사각채널에서 가열 벽면의 수가 열전달에 미치는 효과 (Effect of Number of Heating Walls on Heat Transfer in Ribbed Rectangular Channel)

  • 배성택;안수환;김명호;이대희;강호근
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.514-520
    • /
    • 2005
  • Surface heat transfer of a fully developed turbulent air flow in a $45^{\circ}$ inclined ribbed square duct with two and four heating walls was experimentally investigated, at which the experimental works were peformed for Reynolds numbers ranging from 7,600 to 26,000. The pitch-to-rib height ratio, p/e, was kept at 8 and rib-height-to-channel hydraulic diameter ratio, $e/D_h$ was kept at 0.0667. The channel length-to-hydraulic diameter ratio, $L/D_h$ was 60. The heat transfer coefficient values were decreased with the increase in the number of heat-ing walls. Results of this investigation could be used in various applications of internal channel turbulent flow involving roughened walls.

고온기 야간시간 근권냉방이 파프리카 배지온도와 생리적 반응에 미치는 영향 (The Effect of Root Zone Cooling at Night on Substrate Temperature and Physiological Response of Paprika in Hot Climate)

  • 최기영;고지연;최은영;이한철;이성은;이용범
    • 생물환경조절학회지
    • /
    • 제22권4호
    • /
    • pp.349-354
    • /
    • 2013
  • 본 실험은 고온기 근권냉방이 파프리카의 배지온도 하강과 파프리카의 생리적 반응에 미치는 영향을 알아보고자 7월 16일부터 10월 15일까지 코이어 배지에서 재배하였다. 냉방방식은 공기순환 덕트(지름 12cm, 미세구멍(0.1mm)으로 찬 공기(7월~8월; $20{\pm}2^{\circ}C$, 9월; $23{\pm}2^{\circ}C$)를 야간시간(오후 5시~오전 3시) 공급하였다. 고온기(7월 23일부터 8월 31일) 중 파프리카 배지의 일평균 온도가 냉방처리구는 $24.7^{\circ}C$, 대조구는 $28.2^{\circ}C$로, 냉방처리구에서 대조구보다 $3.0{\sim}5.6^{\circ}C$ 배지온도가 낮아졌다. 하루 중 맑은 날($650{\sim}700W{\cdot}m^{-2}$) 주간(오전 5시~오후 8시)/야간(오후8시~오전5시) 냉방처리구 배지 온도는 대조구보다 $1.7^{\circ}C/3.3^{\circ}C$ 낮아졌다. 오후 6시에서 8시까지 초저녁 배지온도 하강속도가 냉방처리구에서는 평균 $0.5^{\circ}C/h$, 대조구는 $0^{\circ}C/h$였다. 배지 상부와 하부 간의 대조구 대비 냉방처리구의 온도차도 각각 $1.3^{\circ}C$, $0.6^{\circ}C$였다. 냉방처리는 고온($28{\sim}32^{\circ}C$) 배지 온도 노출율을 대조구 대비 32.5% 감소시켰다. 냉방처리구의 파프리카 광합성, 증산율 및 수분포텐셜은 대조구보다 높았다. 첫 개화시기도 대조구보다 4일 앞당겨지고, 착과수도 증가하였다. 냉방처리구의 엽장은 짧아졌으나, 초장, 경경, 분지수, 엽폭 등은 차이가 없었다. 야간 근권냉방으로 배지 온도가 $3.0{\sim}5.6^{\circ}C$를 낮추었으나, 고온기 온실 온도가 고온에서는 파프리카 착과가 지연되므로, 지상부 온도 하강 방법을 병행하면 파프리카 생육과 착과에 효과적이라 판단된다.