• Title/Summary/Keyword: P. A. 덕트

Search Result 39, Processing Time 0.03 seconds

Fundamental Experiment on the Flow Characteristics inside the Exhaust Duct of Cone Calorimeter (콘 칼로리미터의 배기 덕트 내부 유동 특성 기초 실험)

  • Shin, Yeon Je;You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.35-40
    • /
    • 2019
  • In this study, the mass flow rate of the heat release rate equation, which is the major factor of the oxygen consumption method, was analyzed for the fundamental investigation of the cone-calorimeter (5 m length and 0.3 m diameter). The shapes of a completely empty inside, 3 mm pore diameter mesh and pore diameter 10 mm honeycomb with 0.76 porosity were constructed using the cone-calorimeter. To calculate the mass flow rate, four bi-directional probes and thermocouples were installed in a uniform position in the vertical direction of flow. The velocity gradient and flow perturbation were measured from the increase in Reynolds number. As the flow capacity increased, the speed gradient increased in all three shapes relative to the turbulence intensity. In addition, the deviation of extended uncertainty to the mass flow was completely low in the order of empty space, mesh (dp = 3 mm) and honeycomb (dp = 10 mm and 𝜖 = 0.76) at the 95% confidence level. The results can be used in designs to improve the flow stability of the cone calorimeter.

Natural Convection Heat Transfer of an Inclined Helical Coil in a Duct (기울어진 덕트 내 헬리컬 코일의 자연대류 열전달)

  • Park, Joo-Hyun;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.13-20
    • /
    • 2014
  • The natural convection heat transfers of a helical coil in a duct were measured experimentally varying the inclination. To achieve high Rayleigh number, mass transfer experiments instead of heat transfer experiments were performed based upon the analogy. The $Ra_D$ was fixed to $4.55{\times}10^6$. The turn numbers were 1~10. the pitch to diameter ratio were 1.3~5, and the inclination of the helical coil $0^{\circ}{\sim}90^{\circ}$. The measured $Nu_D$ for a single turn of the helical coil was very close to that from McAdams heat transfer correlation for a horizontal cylinder. The heat transfers of the helical coil were varied by the pith, number of turns, and duct height in a complex manner showing the velocity, chimney, and pre-heating effects. The results of the study contributes to the phenomenological analyses of the natural convection heat transfer of a compact heat exchanger.

Detailed Measurement of Heat/Mass Transfer in a Rotating Two-Pass Duct (II) - Effects of Duct Aspect Ratio - (이차 냉각 유로를 가진 회전덕트에서 열/물질전달 특성 (II) - 덕트 종횡비에 따른 영향 -)

  • Kim Kyung Min;Kim Yun Young;Rhee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.921-928
    • /
    • 2004
  • Measurements of local heat/mass transfer coefficients in rotating two-pass ducts are presented. Ducts of three different aspect ratios (W/H), 0.5, 1.0 and 2.0, are employed with a fixed hydraulic diameter ($D_h$) of 26.7 nm. $90^{\circ}$-rib turbulators are attached on the leading and trailing walls symmetrically. The rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The experimental conditions are the same as those of the previous part of the study. As the rib height-to-duct height ratio (e/H) increases, the core flow is more disturbed and accelerated in the midsections of ribs. Therefore, the obtained data show higher heat/mass transfer in the higher aspect ratio duct. Dean vortices also augment heat/mass transfer in the turn and in the upstream region of the second pass. However, the effect becomes less significant for the higher aspect ratio because the surface area increases in the present geometric condition. The effect of rotation produces heat/mass transfer discrepancy.

A study on a uniformity of flow field in a duct cooler of FGD system (배연탈황설비 덕트쿨러에서의 유동균일화에 관한 연구)

  • 배진효;김광추;박만흥;박경석;이종원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.120-130
    • /
    • 2000
  • A flow uniformity in a duct cooler of duct system of FGD(Flue Gas Desulfurization) linking a reheater and a absorber has been investigated in the present study. For this purpose, the flow characteristics according to the geometry of a vertical and horizontal vane in a curved duct of the duct system has been examined with the aid of a numerical simulation. The results indicate that the vertical vane with a little deflection toward a recirculation region makes the flow distribution in the duct cooler more uniform than that without deflection, and horizontal vane does not effect the change of the flow distribution for an angle of inclination. The mean flow uniform factor shows its maximum for duct system without the vane(case NP) and its minimum for the vertical vane with a little deflection(case P-0.8-0) .

  • PDF

A Study on the Vibration Phenomena of the Duct-fan Systems in Fossil Fueled Boilers : Inlet Vortex Induced Excessive Vibration (화력 발전용 보일러 덕트-홴 시스템의 진동현상에 대한 연구 : 입구측 와류에 의한 과대진동 사례)

  • 김철홍;주영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in a fan-duct system of fossil fueled boilers. We measured static pressure variation (pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this Paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

Evaluation of Heating Performance and Analysis of Heating Loads in Single Span Plastic Greenhouses with an Electrical or Hot-Air Heating (전기히터식 난방, 온풍난방시스템을 채용한 단동 플라스틱 하우스의 열부하 해석 및 난방성능 평가)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.136-146
    • /
    • 1999
  • A series of experiments were carried out in winter to investigate the indoor thermal environment in greenhouses with different kinds of heating systems, and characterize the energy consumption, heat transport and thermal energy efficiency of each system. By the Quantitative calculation of heat losses which transmit through the covers of greenhouse, the fundamental data of energy-saving of the particular heating system were obtained. And from the analysis of air temperature differences between indoor and outside, it was possible to select more effective energy-saving and comfortable heating system in greenhouses. The electric heater was more stable in thermal environment and cheaper in cost, since it could be used during the surplus time of electric power from 10:00 p.M. to 8:00 A.M. But the low air temperature in greenhouses besides these times resulted in a chilling problem of the crops. The heating system by hot air had the advantage to show nearly uniform temperature difference by the height above the ground. But the system had the disadvantage to require more energy consumption than the electric heating system.

  • PDF

Effects of Rib Shapes on the Friction Factors and Heat Transfer in a Rectangular Duct (사각 덕트에서 거칠기 형상이 마찰계수와 열전달에 미치는 효과)

  • 안수환;손강필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.341-347
    • /
    • 2001
  • A comparison of fully developed heat transfer and friction factor characteristics has been made in rectangular ducts with ones roughened by five different shapes. The effects of rib shape geometries and Reynolds number are examined. The rib height-to-duct hydraulic diameter, pitch-to height ratio, and aspect ratio of channel width to height are fixed at $e$/De=0.0476, P/$e$=8, and W/H=2.33, respectively. To understand the mechanisms of the heat transfer enhancements, the measurements of the friction factors are also conducted in the smooth and rough channels. The data indicates that the triangular type rib has a substantially higher heat transfer performance than any other ones in the range we studied.

  • PDF

Excessive Vibration of the Fan-duct Systems in 500 MW Power Plant Boilers Due to Inlet Cone Vortex (Inlet Cone Vortex에 의한 500 MW급 발전용 보일러 홴-덕트 시스템의 과대진동)

  • Kim, Cheol Hong;Ju, Young Ho;Byun, Hyung Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.116-121
    • /
    • 2000
  • During the operation, fatigue failures and cracks of duct plate due to excessive duct vibration occurred in the fan-duct systems of fossil fueled boilers. We measured static pressure variation(pressure pulsation) in the outlet, and also measured vibration at the outlet duct of a centrifugal fan. It was found that strong pressure Pulsation caused by the inlet vortex occurred in inlet vane of centrifugal fan in the middle range of vane opening. Thus, excessive duct vibration is caused by strong pressure pulsation. In this paper, it is shown that the frequency and amplitude of pressure pulsation depend mainly on vane opening and are compared with duct vibration. Also, effective solution for reducing pressure pulsation and vibration are presented.

  • PDF