• 제목/요약/키워드: P-closed

검색결과 1,016건 처리시간 0.032초

불안정 발판(Unstable Platform)에서 20대 연령의 균형능력 평가 (Evaluation of the Balance Ability for 20 to 29 Years Old on the Unstable Platform)

  • 권오윤;최홍식
    • 한국전문물리치료학회지
    • /
    • 제3권3호
    • /
    • pp.1-11
    • /
    • 1996
  • The purpose of this study were to evaluate and compare the balance ability at different conditions in normal 20 to 29 years old on unstable platform, KAT 2000(Breg, Inc., Vista, CA. 1994). Static and dynamic BI(balance index) were measured 3psi and 5psi surface conditions. Static tests were done on right and left leg separately, then both legs together with the feet apart 20cm with the eyes opened and closed. Dynamic tests were done on both legs together with apart 20cm with the eyes opened. A dynamic test was performed in which the subject moved platform in a circular manner to chase a moving object on a computer screen. Seventy healthy students(average 21.6 years, male, female) were tested. In this study applied the paired t-test and correlation to determine the statistical significance of result. The results were as follow: 1) The mean static balance index of the Rt leg was $119.9{\pm}75.72$ on 3psi surface condition with the eyes opened, and that of the Lt leg was $224.3{\pm}121.16$. 2) The mean static balance index of the Rt leg was $93.1{\pm}24.16$ on 5psi surface condition with the eyes opened, and that of the Lt leg was $180.5{\pm}61.76$. 3) The mean static and dynamic balance index of both legs were $76.4{\pm}31.86$, $2187.6{\pm}696.99$ on 3psi with the eyes opened, and $68.3{\pm}14.82$, $1938.7{\pm}525.41$ on 5psi respectively. 4) The mean static balance index of the Rt leg was $517.8{\pm}220.87$ on 3psi surface condition with the eyes closed, and that of the Lt leg was $588.6{\pm}204.81$. 5) The mean static balance index of the Rt leg was $271.9{\pm}192.151$ on 5psi surface condition with the eyes closed, and that of the Lt leg was $363.4{\pm}98.97$. 6) The mean static balance index of both legs was $332.6{\pm}137.31$ on 3psi surface condition with the eyes closed, and that of the 5psi was $288.5{\pm}133.07$. 7) The balance index on 3psi surface condition was significantly higher than that of 5psi (p<0.05, p<0.01). 8) The balance index with the eyes closed was significantly higher than that of the eyes opened (p<0.05). 9) The balance index on the left leg was significantly higher than that of the right leg (p<0.05, p<0.01). 10) There was no correlation between static balance index and dynamic balance index. 11) Therewas no correlation between weight or height and balance index.

  • PDF

Reduction of Nasal Bone Fracture using Ultrasound Imaging during Surgery

  • Hwang, So-Min;Pan, Hao-Ching;Kim, Hong-Il;Kim, Hyung-Do;Hwang, Min-Kyu;Kim, Min-Wook;Lee, Jong-Seo
    • 대한두개안면성형외과학회지
    • /
    • 제17권1호
    • /
    • pp.14-19
    • /
    • 2016
  • Background: Most nasal bone fractures are corrected using non-invasive methods. Often, patients are dissatisfied with surgical outcomes following such closed approach. In this study, we compare surgical outcomes following blind closed reduction to that of ultrasound-guided reduction. Methods: A single-institutional prospective study was performed for all nasal fracture patients (n=28) presenting between May 2013 and November 2013. Upon research consent, patients were randomly assigned to either the control group (n=14, blind reduction) or the experimental group (n=14, ultrasound-guided reduction). Surgical outcomes were evaluated using preoperative and 3-month postoperative X-ray images by two independent surgeons. Patient satisfaction was evaluated using a questionnaire survey. Results: The experimental group consisted of 4 patients with Plane I fracture and 10 patients with Plane II fracture. The control group consisted of 3 patients with Plane I fracture and 11 patients with Plane II fracture. The mean surgical outcomes score and the mean patient dissatisfaction score were found not to differ between the experimental and the control group in Plane I fracture (p=0.755, 0.578, respectively). In a subgroup analysis consisting of Plane II fractures only, surgeons graded outcomes for ultrasound-guided reduction higher than that for the control group (p=0.007). Likewise, among the Plane II fracture patients, those who underwent ultrasound-guided reduction were less dissatisfied than those who underwent blind reduction (p=0.043). Conclusion: Our study result suggests that ultrasound-guided closed reduction is superior to blind closed reduction in those patients with Plane II nasal fractures.

Effects of Nutrient Solution Application Methods and Rhizospheric Ventilation on Vegetative Growth of Young Moth Orchids without a Potting Medium in a Closed-Type Plant Factory

  • Min, Sang Yoon;Oh, Wook
    • 인간식물환경학회지
    • /
    • 제23권5호
    • /
    • pp.545-554
    • /
    • 2020
  • Background and objective: Moth orchids in the vegetative stage are suitable for a multi-layer growing environment in a closed-type plant factory which can be a good alternative that can reduce production costs by reducing cultivation time and energy cost per plant. This study was conducted to find out the optimal rhizospheric environment for different irrigation methods without a potting medium and rhizospheric ventilation for the vegetative growth of young Phalaenopsis hybrid 'Blanc Rouge' (P. KV600 × P. Kang 1) and Phalaenopsis Queen Beer 'Mantefon' in a closed-type plant factory system. Methods: The one-month-old clonal micropropagules with bare roots rapped with a sponges were fixed on the holes of styrofoam plates above growth beds, and were watered using the ebb-and-flow (EBB) and aeroponic (AER) methods with Ichihashi solution (0.5 strength) once a day at 06:00 (P) or 18:00 (S), and both (PS). Rhizospheric ventilation (V) was also applied to change the temperature, relative humidity, and CO2 concentration of the beds. Plants potted into sphagnum moss and watered once a week were used as the control group. Results: After 12 months of treatment, the growth characteristics of the EBB groups were the best among the treatment groups without a medium, but no effect of irrigation timing was observed. V reduced the temperature, relative humidity and CO2 concentration of the beds. Whereas, EBB+V (ebb-and-flow with ventilation) improved plant growth and reduced the occurrence of disorders and withering. Especially, EBB+V showed a similar performance to the control group. Conclusion: The results indicated that the optimal irrigation method without a potting medium for producing middle-aged potted moth orchids was the EBB system with forced rhizospheric ventilation. Therefore, further studies on the optimal ventilation method and moisture control of the crown need to be carried out to develop the irrigation system without a potting medium for vertical farming in closed-type plant factories.

한국 남동지역 상류 하천에서의 낙엽 분해기작과 shredder 분포 유형 (Leaf Litter Processing and Patterns of Shredder Distribution in Headwater Steams in Southeastern Korea)

  • Kim Hyun-woo;Gea-Jae Joo;Jong-hoon Choi
    • The Korean Journal of Ecology
    • /
    • 제19권6호
    • /
    • pp.529-541
    • /
    • 1996
  • During the period of December 1992 (winter-spring) and from February 1995 (winter-spring), the leaf processing rates of oak (Quercus serrata) and tulip (Liriodendron tulipifera) tree was investigated in the headwater streams in southeastern part of Korea in conjunction with the distribution pattern of macroinvertebrate fauna. Using two types of bags ($10\times30cm$ with 5 g of dry leaves; open bag with holes, closed bag without holes), decomposition rates of oak and tulip tree by shredder and/or microbiota at a reatively undisturbed 2nd-order stream were compared, Regardless of leaf type, leaves in the open bage decomposed slightly faster than those in the closed bags. In the 1992 experiment, osk leaves decomposed much slower than tulip leaves (after 138 degree days, osk : closed, 0.006% loss/day ; open, 0.008 ; tulip: closed, 0.021 ; open, 0.023; n=2). The of the first experiment using oak leaves in 1995 were similar to those of the first experiment (after 151 degree days, oak: closed, 0.005% loss / day; open, 0.006; n=6). Over 50% of invertebrates from 122 leaf pack samples collected from 12 streams during the winter period of 1994 were identified as shredders (shredder, 56.2; collector, 32.7; scraper, 8.65; predator, 2.45%). Among shredders, Gammarus sp. and Tipula sp. were dominant species in terms of number and biomass (8.2 ind./g, 1.0 ind./g AFDW of leaves). Among many physico-chemical parameters, the width of stream channel was found to be the most influential factor in the distribution of Gammarus and Tipula (Gammarus: r=-0.34, P<0.001;Tipula:r=0.40, P<0.001). Considering the fact that oak is one the dominant riparian vegetation in the southeastern part of korea, the patterns of oak processing and shredder distribution shown in theis study may well represent some of the important characteristics of headwater steams in southeastern Korea.

  • PDF

Effect of lidocaine on pain caused by nasal pack removal after closed reduction of nasal bone fractures

  • Sung, Ji Yoon;Kang, Kyung Dong;Kim, Min Wook;Kim, Joo Hyoung
    • Archives of Plastic Surgery
    • /
    • 제47권1호
    • /
    • pp.15-19
    • /
    • 2020
  • Background Pain caused by nasal pack removal after closed reduction of nasal bone fractures is a common problem. This study investigated the effect of infiltrating lidocaine into nasal packs on the pain caused by pack removal after closed reduction of nasal bone fractures. Methods Seventy-five patients who underwent closed reduction of nasal bone fractures between March 2016 and March 2018 were enrolled in this prospective, randomized, single-blind study. Merocel (hydroxylated polyvinyl acetate) packs were applied bilaterally and retained for 5 days. Twenty minutes before removal, both packs were rehydrated with 6 mL of 2% lidocaine in 26 patients and with 6 mL of saline in 24 patients; the packs were not rehydrated in 25 patients. Visual analog scale (VAS) scores for pain on removal were recorded. Results The mean VAS score was 5.3±2.0 in all patients, 3.8±1.5 in the lidocaine group, 5.8±1.4 in the saline group, and 6.3±2.1 in the non-rehydrated group. There was a significant difference in the pain score between the lidocaine and saline groups (P<0.001) but not between the saline and non-rehydrated groups (P=0.186). Conclusions Infiltration of lidocaine into Merocel packs reduced the pain caused by pack removal after closed reduction of nasal bone fractures.

${H^1}({\Omega})$-NORM ERROR ANALYSIS UNDER NUMERICAL QUADRATURE RULES BY THE P-VERSION OF THE FINITE ELEMENT METHOD

  • Kim, Ik-Sung;Kim, Chang-Geun;Song, Man-Suk
    • 대한수학회논문집
    • /
    • 제9권2호
    • /
    • pp.467-489
    • /
    • 1994
  • Let $\Omega$ be a closed and bounded polygonal domain in R$^2$, or a closed line segment in R$^1$ with boundary $\Gamma$, such that there exists an invertible mapping T : $\Omega$ \longrightarrow $\Omega$ with the following correspondence: x$\in$$\Omega$ ↔ x = T(x) $\in$$\Omega$, (1.1) and (1.2) t $\in$ U$\sub$p/($\Omega$) ↔ t = to T$\^$-1/ $\in$ U$\sub$p/($\Omega$), where $\Omega$ denotes the corresponding reference elements I = [-1,1] and I ${\times}$ I in R$^1$ and R$^2$ respectively, (1.3) U$\sub$p/($\Omega$) = {t : t is a polynomial of degree $\leq$ p in each variable on $\Omega$}, and (1.4) U$\sub$p/($\Omega$) = {t : t = to T $\in$ U$\sub$p/($\Omega$)}.(omitted)

  • PDF

경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구 (Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model)

  • 이혁재;김창회;임영준;김명주
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.201-208
    • /
    • 2008
  • 연구목적: 시멘트 유지형 지대주를 인상용 코핑으로 이용하고 레진이나 금속 구조물에 접착하여 스플린팅하는 새로운 인상법을 시도하였다. 연구의 목적은 첫 번째, 3개의 임플랜트가 $15^{\circ}$ 경사지게 식립된 모형에서 closed tray 인상법과 레진 스플린팅한 open tray 인상법의 정확성을 비교하는 것이고 두 번째, 새로운 인상법의 정확성을 앞의 두 가지 인상법과 비교하는 것이다. 연구 재료 및 방법: 3개의 임플랜트 아날로그가 선상으로 배열되고 가운데 아날로그는 모형에 수직이고 양쪽 끝 아날로그는 이것에 앞뒤로 $15^{\circ}$ 경사지게 배열된 주모형과 주모형에 잘 적합되는 기준구조물을 제작하였다. closed tray 인상법, 레진 스플린팅한 open tray 인상법, 지대주-레진구조물 접착 인상법, 지대주-금속구조물 접착 인상법, 각 10개씩 40번의 인상을 채득하여 복제모형을 제작하였다. 이미지 처리할 수 있는 광학 현미경을 이용하여 기준구조물과 복제모형내의 아날로그와의 수직간격을 측정하여 인상의 정확성을 평가하였다. 통계처리는 one-way ANOVA와 사후 검정으로 Tukey test를 5% 유의수준으로 시행하였다. 결과: closed tray 인상법;74.3 (${\pm}33.4$)${\mu}m$의 간격은 레진 스플린팅한 open tray 인상법과 다른 두 가지 새로운 인상법보다 간격의 크기가 통계적 유의성 있게 컸다(P<.05). 지대주-금속구조물 접착 인상법;42.5 (${\pm}11.9$)${\mu}m$은 다른 인상법들 보다 간격의 크기가 통계적 유의성 있게 작았다(P<.05). 지대주-레진구조물 접착 인상법;51.0 (${\pm}14.1$)${\mu}m$은 레진 스플린팅한 open tray 인상법50.3 (${\pm}16.9$)${\mu}m$과 통계적 유의성 있는 차이를 보이지 않았다(P>.05). 결론: 이 연구의 한계 내에서, 레진 스플린팅한 open tray 인상법은 closed tray 인상법보다 우수한 정확성을 나타내었고, 지대주를 금속구조물에 접착하는 새로운 인상법의 정확성은 레진 스플린팅한 open tray 인상법보다 우수하였다.

A note on k-nil radicals in BCI-algebras

  • Hong, Sung-Min;Xiaolong Xin
    • 대한수학회보
    • /
    • 제34권2호
    • /
    • pp.205-209
    • /
    • 1997
  • Hong et al. [2] and Jun et al. [4] introduced the notion of k-nil radical in a BCI-algebra, and investigated its some properties. In this paper, we discuss the further properties on the k-nil radical. Let A be a subset of a BCI-algebra X. We show that the k-nil radical of A is the union of branches. We prove that if A is an ideal then the k-nil radical [A;k] is a p-ideal of X, and that if A is a subalgebra, then the k-nil radical [A;k] is a closed p-ideal, and hence a strong ideal of X.

  • PDF

첨가제 사용에 의한 Epoxy Resin 용액의 인화점 측정 (Measurement of Flash Points of Epoxy Resin Solutions by Using Additives)

  • 하동명
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.22-27
    • /
    • 2007
  • The knowledge of the flash point of the various liquid substances is required because of process safety and control in industrial fire protection. The epoxy resin is one of versatile resins that has wide selection of using curing agents and additives to achieve various applications such as coatings, adhesives, interior materials, reinforced plastics and electrical insulation. In this study, the lower flash points for p-xylene+epoxy resin, o-xylene+epoxy resin and n-butanol+epoxy resin systems were measured by using Pensky-Martens closed cup tester. The lower flash points for p-xylene+epoxy resin, o-xylene+epoxy resin and n-butanol+epoxy resin systems rapidly increased 80wt%, 90wt% and 95wt% of epoxy resin concentration, respectively. This results serve as a guide to estimate flash point of any epoxy resin solution.

Two Extensions of a Star Operation on D to the Polynomial Ring D[X]

  • Chang, Gyu Whan;Kim, Hwankoo
    • Kyungpook Mathematical Journal
    • /
    • 제61권1호
    • /
    • pp.23-32
    • /
    • 2021
  • Let D be an integral domain with quotient field K, X an indeterminate over D, ∗ a star operation on D, and Cl∗ (D) be the ∗-class group of D. The ∗w-operation on D is a star operation defined by I∗w = {x ∈ K | xJ ⊆ I for a nonzero finitely generated ideal J of D with J∗ = D}. In this paper, we study two star operations {∗} and [∗] on D[X] defined by A{∗} = ∩P∈∗w-Max(D) ADP [X] and A[∗] = (∩P∈∗w-Max(D) AD[X]P[X]) ∩ AK[X]. Among other things, we show that Cl∗(D) ≅ Cl[∗](D[X]) if and only if D is integrally closed.