• 제목/요약/키워드: P-N Curve

Search Result 456, Processing Time 0.028 seconds

Elution Patterns of Native Sulfate and Breakthough Curve′s of Anions from Bt Soils of Chungwon Series (청원통 Bt 토양에 내재된 황산이온의 용출특성과 음이온의 파쇄특성)

  • Chung Doug-Young;Jin Hyun-O
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.2 no.4
    • /
    • pp.190-197
    • /
    • 2000
  • Anions such as C $l^{[-10]}$ , N $O_3$$^{[-10]}$ , S $O_4$$^{2-}$, P $O_4$$^{3-}$, and organic anions, that do not become a part of the clay mineral crystal lattice, are of considerable interest in soils which are a potential sink caused by acid rain. In this paper, elution of native sulfate and breakthrough curves (BTC) were obtained from miscible displacement of non-specifically or specifically adsorbed anions through non-saturated or saturated Bt soil of Chungwon series. The shape and position of the BTC's could be affected by adsoprtion and ion exchange onto the soil particle surfaces. Measured BTC's for oxalic acid under unsaturated and saturated conditions showed that less pore volumes were required to displace the native S $O_4$$^{2-}$S from the soil column, and that maximum detection limit of oxalic acid reached earlier than under unsaturated. The retarded BTC's to the righthand side could be attributed by different adsorption behavior of each anion, although BTC's may be influenced by the smaller order of velocity change. The alternate breakthrough and elution curves show the rapid approach to the maximum detection limit of C/Co = 1, compared to progressive tailing of elution curve to reach to C/Co = 0. The probable explanation for asymmetric elution patterns for both anion is that the anion was selectively adsorbed on the positively charged soil surface from the solution passing in the soil column. On the other hand, the variations of pH in effluent showed that pH was increased to 7 in the first 6 pore volume and then gradually decreased to pH 4.

  • PDF

Plasma Vascular Endothelial Growth Factors A and C in Patients undergoing Prostatic Biopsy and TURP for Suspected Prostatic Neoplasia

  • Singh, A.N.;Gautam, Kirti A.;Dalela, D.;Sankhwar, S.N.;Natu, S.M.;Sankhwar, P.L.;Srivastava, A.N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.2053-2058
    • /
    • 2013
  • Background: Formation of new blood vessels is necessary for the development and spread of neoplasms more than 1 mm3 in volume, angiogenesis being responsible for formation of new from pre-existing blood vessels. Vascular endothelial growth factor (VEGF) is pivotal and the best studied angiogenic factor in all human cancers. Therefore we designed this study to investigate the role of VEGF-A and VEGF-C in prostate cancer in comparison with BPH controls in a north Indian population. Methods: In this case-control study a total of 100 subjects were included on the basis of confirmed histopathological reports, out of which 50 were prostate cancer patients and the other 50 were BPH patients with PSA levels >2 ng/ml and abnormal digital rectal examination (DRE) findings during September 2009 to August 2011 from the Department of Urology, KGMU, Lucknow, India. Plasma levels of VEGF were determined using quantitative immunoassay (ELISA-enzyme linked immunosorbent assay). Statistical analysis was carried out using SPSS 15.0 version. Results: The mean age of prostate cancer ($67.6{\pm}5.72$) patients was significantly higher (p=0.005) than BPH ($63.6{\pm}7.92$) patients. Expression of VEGF-A was not significantly higher in disease stage C1 than D1 or D2 and A or B (p=0.13) while the level of VEGF-A was significantly higher (p=0.04) in prostate cancer as compared to BPH subjects (PCa=13.0 pg/ml, BPH=6.8 pg/ml). Levels of VEGF-C were similar in both groups (PCa=832.6 pg/ml, BPH=823.7 pg/ml). In ROC curve, the area under curve (AUC) was 0.70 (95%CI: 0.60-0.80) and the cut-off value for which a higher proportion of patients was correctly classified (20%) was 26.0 pg/mL. Conclusion: Although VEGF-A is increased in cancer prostate patients a statistically significant correlation could not be established in this study. VEGF-C was not found to be a useful biomarker.

Stereo Vision based on Planar Algebraic Curves (평면대수곡선을 기반으로 한 스테레오 비젼)

  • Ahn, Min-Ho;Lee, Chung-Nim
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.1
    • /
    • pp.50-61
    • /
    • 2000
  • Recently the stereo vision based on conics has received much attention by many authors. Conics have many features such as their matrix expression, efficient correspondence checking, abundance of conical shapes in real world. Extensions to higher algebraic curves met with limited success. Although irreducible algebraic curves are rather rare in the real world, lines and conics are abundant whose products provide good examples of higher algebraic curves. We consider plane algebraic curves of an arbitrary degree $n{\geq}2$ with a fully calibrated stereo system. We present closed form solutions to both correspondence and reconstruction problems. Let $f_1,\;f_2,\;{\pi}$ be image curves and plane and $VC_P(g)$ the cone with generator (plane) curve g and vertex P. Then the relation $VC_{O1}(f_1)\;=\;VC_{O1}(VC_{O2}(f_2)\;∩\;{\pi})$ gives polynomial equations in the coefficient $d_1,\;d_2,\;d_3$ of the plane ${\pi}$. After some manipulations, we get an extremely simple polynomial equation in a single variable whose unique real positive root plays the key role. It is then followed by evaluating $O(n^2)$ polynomials of a single variable at the root. It is in contrast to the past works which usually involve a simultaneous system of multivariate polynomial equations. We checked our algorithm using synthetic as well as real world images.

  • PDF

Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream (황구지천 유역의 오염부하 특성 및 지류 영향 평가)

  • Lim, Su-Jin;Lim, Byung-Ran;Lee, Han-Saem;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.

Structural Analysis of Ag Agglomeration in Ag-based Ohmic Contact to p-type GaN (고분해능 X선 회절을 이용한 Ag 기반 p형 반사막 오믹 전극 집괴 분석)

  • Son, J.H.;Song, Y.H.;Lee, J.L.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2011
  • We investigate the crystallographic orientation and strain states of the Ni/Ag ohmic contacts on p-type GaN. The Ag film in the Ni/Ag contact was severely agglomerated during high temperature annealing in air ambient. As a results, after annealing for 24 h, the Ni/Ag contact shows non-linear I-V curve and low light reflectance of ~21% at 460 nm wavelength. High-resolution X-ray diffraction results show that the interplanar spacing of Ag (111) planes is almost same to that of bilk Ag after annealing for 24 hrs, indicating that the in-plane tensile strain in the Ag film was fully relaxed due to the Ag agglomeration.

Additional Value of Integrated 18F-FDG PET/MRI for Evaluating Biliary Tract Cancer: Comparison with Contrast-Enhanced CT

  • Jeongin Yoo;Jeong Min Lee;Jeong Hee Yoon;Ijin Joo;Dong Ho Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.714-724
    • /
    • 2021
  • Objective: To evaluate the value of 18F-fluorodeoxyglucose PET/MRI added to contrast-enhanced CT (CECT) in initial staging, assessment of resectability, and postoperative follow-up of biliary tract cancer. Materials and Methods: This retrospective study included 100 patients (initial workup [n = 65] and postoperative follow-up [n = 35]) who had undergone PET/MRI and CECT for bile duct or gallbladder lesions between January 2013 and March 2020. Two radiologists independently reviewed the CECT imaging set and CECT plus PET/MRI set to determine the likelihood of malignancy, local and overall resectability, and distant metastasis in the initial workup group, and local recurrence and distant metastasis in the follow-up group. Diagnostic performances of the two imaging sets were compared using clinical-surgical-pathologic findings as standards of reference. Results: The diagnostic performance of CECT significantly improved after the addition of PET/MRI for liver metastasis (area under the receiver operating characteristic curve [Az]: 0.77 vs. 0.91 [p = 0.027] for reviewer 1; 0.76 vs. 0.92 [p = 0.021] for reviewer 2), lymph node metastasis (0.73 vs. 0.92 [p = 0.004]; 0.81 vs. 0.92 [p = 0.023]), and overall resectability (0.79 vs. 0.92 [p = 0.007]; 0.82 vs. 0.94 [p = 0.021]) in the initial workup group. In the follow-up group, the diagnostic performance of CECT plus PET/MRI was significantly higher than that of CECT imaging for local recurrence (0.81 vs. 1.00 [p = 0.029]; 0.82 vs. 0.94 [p = 0.045]). Conclusion: PET/MRI may add value to CECT in patients with biliary tract cancer both in the initial workup for staging and determination of overall resectability and in follow-up for local recurrence.

Corrosion Behavior of High Pressure Die Cast Al-Ni and Al-Ni-Ca Alloys in 3.5% NaCl Solution

  • Arthanari, Srinivasan;Jang, Jae Cheol;Shin, Kwang Seon
    • Corrosion Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.100-108
    • /
    • 2017
  • In this investigation corrosion behavior of newly developed high-pressure die cast Al-Ni (N15) and Al-Ni-Ca (NX1503) alloys was studied in 3.5% NaCl solution. The electrochemical corrosion behavior was evaluated using open circuit potential (OCP) measurement, potentiodynamic polarization, and electrochemical impedance spectroscopy (EIS) techniques. Potentiodynamic polarization results validated that NX1503 alloy exhibited lower corrosion current density ($i_{corr}$) value ($5.969{\mu}A/cm^2$) compared to N15 ($7.387{\mu}A/cm^2$). EIS-Bode plots revealed a higher impedance (${\mid}Z{\mid}$) value and maximum phase angle value for NX1503 than N15 alloy. Equivalent circuit curve fitting analysis revealed that surface layer ($R_1$) and charge transfer resistance ($R_{ct}$) values of NX1503 alloy was higher compared to N15 alloy. Immersion corrosion studies were also conducted for alloys using fishing line specimen arrangement to simultaneously measure corrosion rates from weight loss ($P_W$) and hydrogen volume ($P_H$) after 72 hours and NX1503 alloy had lower corrosion rate compared to N15 alloy. The addition of Ca to N15 alloy significantly reduced the Al3Ni intermetallic phase and further grain refinement may be attributed for reduction in the corrosion rate.

Variations in Tribological Characteristics of SM45C by PVD Coating and Thin Films (SM45C재의 PVD코팅과 필름에 의한 트라이볼러지 특성)

  • Shim, Hyun-Bo;Suh, Chang-Min;Kim, Jong-Hyoung;Suh, Min-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.502-510
    • /
    • 2018
  • In order to accumulate data to lower the friction coefficient of a press mold, tribological tests were performed before and after coating SM45C with a PVC/PO film and plasma coating (CrN, concept). The ultrasonic nanocrystal surface modification (UNSM)-treated material had a nano-size surface texture, high surface hardness, and large and deep compressive residual stress formation. Even when the load was doubled, the small amount of abrasion, small weight of the abrasion, and width and depth of the abrasion did not increase as much as those of untreated materials. A comparison of the weight change before and after the tribological test with the CrN and the concept coating material and that of the untreated material showed that the wear loss of the concept coating material and P-UNSM treated material (that is, the UNSM treated material treated with the concept coating) showed a tendency to decrease by approximately 55-75%. Concept 100N had a lower friction coefficient of about 0.6, and P-UNSM-30-100N showed almost the same curve as concept 100N and had a low coefficient of friction of about 0.6. The concept multilayer coating had a thickness of $5.32{\mu}m$. In the beginning, the coefficient of friction decreased because of the plasma coating, but it started to increase from about 250-300 s. After about 350 s, the coefficient of friction tended to approach the friction coefficient of the SM45C base metal. The SGV-280F film-attached test specimen was slightly pushed back and forth, but the SM45C base material was not exposed due to abrasion. The friction coefficient was 0.22, which was the lowest, and the tribological property was the best in this study.

Effects of Annealing on Ni/Au Ohmic Contact to Nonpolar p-type GaN

  • Lee, Dong-Min;Kim, Jae-Gwan;Yang, Su-Hwan;Kim, Jun-Yeong;Lee, Seong-Nam;Lee, Ji-Myeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.358-359
    • /
    • 2012
  • 최근 분극 특성이 상이한 무분극 GaN 에피성장에 관한 심도 있는 연구와 함께 전자-전공 캐리어의 주입 및 캐리어의 거동, 방출되는 편광 특성 및 다양한 물리적 특성들에 대해 보고되고 있으며, 광학적 특성 및 물리적 특성의 확보를 위한 많은 연구가 활발히 진행 중이다 [1]. GaN의 ohmic 접촉(ohmic contact)의 형성은 발광 다이오드(light emitting diode), 레이저 다이오드(Laser), 태양전지(solar cell)와 같은 고신뢰도, 고효율 광전자 소자를 제조하기 위해서는 매우 중요하다 [2]. 그러나 이와 함께 병행 되어야 할 무분극 p-GaN 의 ohmic contact에 관한 연구는 많이 이루어지고 있지 않는 실정이다. 따라서 본 논문에서는 r-plane 사파이어 기판 상에 성장된 p-GaN에서의 ohmic 접촉 형성 연구를 위하여 Ni/Au ohmic 전극의 접촉저항 특성을 연구하였다. 본 실험에서는 성장된 a-plane GaN의 Hole농도가 $3.09{\times}1017cm3$ 인 시편을 사용하였다. E-beam evaporation 장비를 이용하여 Ni/Au를 각각 20 nm 그리고80 nm 증착 하였으며 비접촉저항을 측정하기 위해 Circle-Transfer Length Method (C-TLM) 패턴을 사용하였다. 샘플은 RTA (Rapid Thermal Annealing)를 사용하여 $300^{\circ}C$에서 $700^{\circ}C$까지 온도를 변화시키며 전기적 특성을 비교하여 그림 1(a) 나타내었다. 그림에서 알 수 있듯이 $400^{\circ}C$에서 가장 낮은 비접촉저항 값인 $6.95{\times}10-3{\Omega}cm2$를 얻을 수 있음을 발견하였다. 이 때의 I-V curve 도 그림1(b)에 나타낸 바와 같이 열처리에 의해 크게 향상됨을 알 수 있다. 그러나, $500^{\circ}C$ 이상 온도를 증가시키면 다시 비접촉 저항이 증가하는 것을 관찰하였다. XRD (x-Ray Diffraction) 분석을 통하여 $400^{\circ}C$ 이상열처리 온도가 증가하면 금속 표면에 $NiO_2$가 형성되며, 이에 따라 오믹특성이 저하 된다고 사료된다. 또한 $Ni_3N$의 존재를 확인 하였으며 이는 nonpolar surface의 특성으로 인해 nitrogen out diffusion 현상이 동시에 발생하여 계면에는 dopant로 작용하는 질소 공공을 남기고 표면에 $Ni_3N$을 형성하여 ohmic contact의 특성이 저하되기 때문인 것으로 사료된다.

  • PDF

Estimation of Reliability of Real-time Control Parameters for Animal Wastewater Treatment Process and Establishment of an Index for Supplemental Carbon Source Addition (가축분뇨처리공정의 자동제어 인자 신뢰성 평가 및 적정 외부탄소원 공급량 지표 확립)

  • Pak, JaeIn;Ra, Jae In-
    • Journal of Animal Science and Technology
    • /
    • v.50 no.4
    • /
    • pp.561-572
    • /
    • 2008
  • Responses of real-time control parameters, such as ORP, DO and pH, to the conditions of biological animal wastewater treatment process were examined to evaluate the stability of real-time control using each parameter. Also an optimum index for supplemental carbon source addition based on NOx-N level was determined under a consideration of denitrification rate by endogenous respiration of microorganism and residual organic matter in liquor. Experiment was performed with lab-scale sequencing batch reactor(SBR) and working volume of the process was 45L. The distinctive nitrogen break point(NBP) on ORP-and DO-time profiles, which mean the termination of nitrification, started disappearing with the maintenance of low NH4-N loading rate. Also the NBP on ORP-and DO-time profiles was no longer observed when high NOx-N was loaded into the reactor, and the sensitivity of ORP became dull with the increase of NOx-N level. However, the distinctive NBP was constantly occurred on pH(mV)-time profile, maintaining unique profile patterns. This stable occurrence of NBP on pH(mV)-time profile was lasted even at very high NOx-N:NH4-N ratio(over 80:1) in reactor, and the specific point could be easily detected by tracking moving slope change(MSC) of the curve. Revelation of NBP on pH(mV)-time profile and recognition of the realtime control point using MSC were stable at a condition of over 300mg/L NOx-N level in reactor. The occurrence of distinctive NBP was persistent on pH(mV)-time profile even at a level of 10,000mg/L STOC(soluble total organic carbon) and the recognition of NBP was feasible by tracing MSC, but that point on ORP and DO-time profiles began to disappear with the increase of STOC level in reactor. The denitrfication rate by endogenous respiration and residual organic matter was about 0.4mg/L.hr., and it was found that 0.83 would be accepted as an index for supplemental carbon source addition when 0.1 of safety factor was applied.