• 제목/요약/키워드: P removal rate

검색결과 1,095건 처리시간 0.024초

Developing numerical method to predict the removal of Microcystin-LR in a clear well

  • Yeo, Inhee;Park, Yong-Gyun;Kim, Dooil
    • Membrane and Water Treatment
    • /
    • 제9권3호
    • /
    • pp.173-179
    • /
    • 2018
  • Microcystin-LR, one of algal toxins induced by the eutrophication of a reservoir, is known to be harmful to human by adversely affecting our liver and brain. Hypochlorous acid is very efficient to remove Microcystin-LR in a clear well. The previous researches showed that CT, pH and temperature affected removal rate in batch tests. It was noted that hydrodynamic properties of clear well could also influence its removal rate. A mathematical model was built using an axial dispersion reactor model and software was used to simulate the removal rate. The model consisted of the second order differential equations including dispersion, convection, Microcystin-LR reaction with chlorine. Kinetic constants were obtained through batch tests with chlorine. They were $0.430{\times}10^{-3}L/mg/sec$ and $0.143{\times}10^{-3}L/mg/sec$ for pH 7.0 and 8.1, respectively. The axial dispersion reactor model was shown to be useful for the numerical model through conservative tracer tests. The numerical model successfully estimated the removal rate of Microcyctin-LR in a clear well. Numerical simulations showed that a small dispersion number, low pH and long hydraulic retention time were critical for higher removal rate with same chlorine dosage. This model could be used to optimize the operation of a clear well during an eutrophication season.

회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거 (Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients)

  • 박종안;허준무;손부순
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.132-140
    • /
    • 1998
  • 회전원판공정(rotating biological contactorRBC)과 화학적 처리공정을 결합한 처리시스템을 이용하여 도시하수내 포함된 유기물과 영양염류를 제거할 경우에 수리학적 부하 (hydraulic loading)와 처리수 반송율 (recirculation rate)의 시스템 처리효율에 미치는 영향을 알아보고자 하였다. 각각의 수리학적 부하 0.031, 0.0535 및 0.076 $m^3/m^2/d에서 반송율을 100%, 200%, 300%로 변화시켰고, 질산화에 필요한 알카리도의 보충 및 화학적 처리를 위하여 lime(CaCO$_3$)을 가하여 유입수의 pH를 10.4-11.0으로 유지시켰다. 실험결과 수리학적 부하 0.0535 $m^3/m^2/d에서 BOD, COD의 제거효율이 가장 높게 나타났으며, 질산화 효율 및 질소 제거효율에서는 수리학작 부하 0.035 $m^3/m^2/d, 반송율 300%에서 가장 높았으며, 반송율별에서는 수리학적 부하를 고려할 때 300% 반송하는 것이 가장 높은 유기물 제거효율을 보였다. 반송율과 수리학적 부하를 증가시킬 경우에 발생되는 슬러지내 유기물 함량은 점점 증가하였고, 수리학적 부하 0.076 $m^3/m^2/d, 반송율 300%일 경우에는 유기물 함량이 47%로 매우 높았다. 이는 부하증가에 따른 미생물 성장의 증가와 더불어 수리학적 부하 증가에 따른 전단력의 증가가 영향을 미쳤기 때문이다. 인을 제거하기 위하여 pH를 10.4-11.0으로 유지시킨 경우에 인을 90%이상 제거할 수 있었으며, 유출수내 평균 SS농도는 40 mg/l를 상회하였다.

  • PDF

생물난분해성 유기물질 함유 폐수처리를 위한 Fenton 산화법의 효율적 적용방안에 관한 연구 (A Study on the Efficient Applicability of Fenton Oxidation for the Wastewater Containing Non-biodegradable Organics)

  • 전세진;김미정
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.76-83
    • /
    • 2000
  • This research is about wastewater containing non-biodegradable TDI(Toluene Diisocyanate) that is treated by the activated carbon adsorption method. In the case of the Fenton oxidation process being applied to the existing process, optimal pH, reaction time, chemical dosing amount, removal rate, and cost were investigated. A pilot plant test was applied after finding optimal conditions with lab experiments. The optimal conditions were pH 3~5(COD removal rate 84~88%) and reaction time 30min~1hr. In higher $H_2O_2$ dosing amount, COD removal rate was a little higher. But there was little difference in the removal rate according to $FeSO_4{\cdot}7H_2O$ dosing amount. Treatment cost was economical in the case of the Fenton oxidation process being operated earlier than activated carbon adsorption system. But chemical dosing point, chemical mixing effect, chemical dosing amount, removal rate, and the cost of facility and others must be considered in practical process.

  • PDF

질소원 및 pH 조절빈도에 따른 Chlorella vulgaris의 성장특성 및 하수고도처리능 평가 (Growth and N, P removal efficiency of Chlorella vulgaris according to the nitrogen sources and pH condition)

  • 한수현;김선진;김태형;조기주;이윤희;황선진
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.833-840
    • /
    • 2012
  • This study aimed to investigate growth rate and nutrient removal efficiency of Chlorella vulgaris according to nitrogen sources and frequency of pH adjustment. Nitrogen and phosphorus removal efficiencies were evaluated in the three different conditions using $NO_3{^-}$, $NH_4{^+}$ as a sole nitrogen source and mixed condition. Initial nutrient concentrations in artificial wastewater were 30 mg-N/L and 3 mg-P/L similar to secondary wastewater effluent. When nitrogen source was $NO_3{^-}$, there was no inhibition on the growth of C. vulgaris with adjusting pH every 24 hr while growth inhibition occurred with $NH_4{^+}$ caused by pH drop. N, P removal efficiencies were no significant depending on the nitrogen sources. As pH was adjusted to 7 by pH-stat, growth rate and nutrient removal efficiencies were increased compared to adjusting pH every 24 hr, however, growth rate and nutrient removal efficiencies were no significant depending on the nitrogen sources.

고정화 질화세균을 이용한 저농도 암모니아의 고도처리 (II) 초기 암모니아 농도, 온도 그리고 pH의 영향

  • 이정훈;김병진;이민수;나인걸;서근학
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.346-348
    • /
    • 2002
  • This study estimated the effect of influent TAN concentration. temperature and pH in the airlift bioreactor(aeration rate; 1.5 vvm, HRT 0.35hr) using immobilized nitrifiers by PVA. At the effect of influent TAN concentration, removal rate was increased with increasing it and removal efficiency maintained 93${\pm}$2%. The optimum temperature for nitrification was $30^{\circ}C$ and at this point. removal efficiency was 95.5${\pm}$1.5%. It was effective to nitrify at $10^{\circ}C$ of low temperature. In the pH range from 7 to 9 in the bioreactor. removal rate and removal efficiency was 310${\pm}$10 $g/m^3$ day and 94${\pm}$3%.

  • PDF

인공습지 실험시설의 5년간 결과 및 고찰(지역환경 \circled3) (Review of 5-year Experimental Data from Treatment Wetland)

  • 김민희;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.649-654
    • /
    • 2000
  • Field experiment was performed from August 1996 to June 2000. The pilot plant was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand and reed. Average removal rate of BOD, SS was about 75.9%, 73.4%, respectively. T-P removal rate was about 47.3%, and T-N removal rate was 19.6%. The reason for poor T-N removal might be due to high influent concentration and short retention times. As operation period increased, BOD removal rates were increased, and SS and T-P removal rates did not change significantly, but T-N removal rates were decreased.

  • PDF

3상 유동층생물반응기를 이용한 메탄처리에 관한 연구 (Removal of Methane Using a Three Phase Fluidized Bed Bioreactor)

  • 김동욱;서혁상
    • KSBB Journal
    • /
    • 제13권2호
    • /
    • pp.141-146
    • /
    • 1998
  • To remove the low concentration of methane biologically, a three phase fluidized bed bioreactor immobilized with Methylosinus trichosporium OB3b was used. Optimum pH, temperature and bed height for the operation were pH7.0, 30$^\circ C$ and 150cm, respectively. For the inlet methane concentration of 100-400ppm and flow rate of 2-4L/min, the removal efficiencies of the bioreactor using the activated carbon as a carrier were the range of 54-71%, whereas those using the biosand were the range of 45-56%. It was found that activated carbon was more efficient than the biosand for the removal of methane. When aeration tank was equipped with the bioreactor, the removal efficiency increased to 6-13% and maximum removal rate obtained in the experiment was 1184mg.CH$_4$/min.

  • PDF

UV-OXIDATIVE TREATMENT OF BIO-REFRACTORY ORGANIC HALOGENS IN LEACHATE: Comparison Between UV/O3, UV/H2O2, and UV/H2O2/O3 Processes

  • Qureshi, Tahir Imran;Kim, Young-Ju
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.84-90
    • /
    • 2006
  • UV-catalytic oxidation technique was applied for the treatment of bio-refractory character of the leachate, which is generally present in the form of adsorbable organic halogens (AOX). Destruction of AOX was likely to be governed by pH adjustment, quantitative measurement of oxidants, and the selection of oxidation model type. Peroxide induced degradation ($UV/H_2O_2$) facilitated the chemical oxidation of organic halides in acidic medium, however, the system showed least AOX removal efficiency than the other two systems. Increased dosage of hydrogen peroxide (from 0.5 time to 1.0 time concentration) even did not contribute to a significant increase in the removal rate of AOX. In ozone induced degradation system ($UV/O_3$), alkaline medium (pH 10) favored the removal of AOX and the removal rate was found 11% higher than the rate at pH 3. Since efficiency of the $UV/O_3$ increases with the increase of pH, therefore, more OH-radicals were available for the destruction of organic halides. UV-light with the combination of both ozone and hydrogen peroxide ($UV/H_2O_2$ 0.5 time/$O_3$ 25 mg/min) showed the highest removal rate of AOX and the removal efficiency was found 26% higher than the removal efficiency of $UV/O_3$. The system $UV/H2O_2/O_3$ got the economic preference over the other two systems since lower dose of hydrogen peroxide and relatively shorter reaction time were found enough to get the highest AOX removal rate.

수계 내 조류 제거를 위한 전기응집 운전 특성 평가 (Evaluation of Operation Parameters for the Removal of Algae by Electro-Coagulation)

  • 정권;김도군;김석구;김원재;고석오
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.94-102
    • /
    • 2015
  • Electro-coagulation experiments were conducted with aluminum (Al) or iron (Fe) electrode in order to determine the optimal electrode material and operation conditions for algae removal. Al electrode showed higher removal rate of algae than Fe electrode because Al flocs have positive surface charges which electrostatically attract algae species having negative surface charges. Removal rate of algae and total phosphorous (T-P) was increased as current density and electrode area increases. It was also found that initial pH with neutral range was optimum for T-P removal by electro-coagulation. Bench-scale continuous flow experiments consisted of electro-coagulation reactor, agitation tank and settling tank were conducted. In electro-coagulation reactor, a large fraction of Al flocs were distributed to scum layer, due to the gas bubbles generated by electrolysis reaction. In agitation tank, most of Al flocs were settled and the optimal mixing intensity was found to be 50 rpm to achieve good settleability. The removal rate of algae was about 90-95%. Additionally, the removal rate of the T-P and COD was observed to be $73.8{\pm}8.0%$ and $75.0{\pm}3.8%$, respectively. Meanwhile, the removal rate of total nitrogen (T-N) was relatively low at only 24%.

축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향 (Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.