• Title/Summary/Keyword: P/A ratio

Search Result 11,822, Processing Time 0.043 seconds

A New Analysis Method of the Consolidation Test Data for an Undisturbed Clay (불교란 점토 압밀시험 결과의 새로운 해석법)

  • 박종화;고우모또타쯔야
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.6
    • /
    • pp.106-114
    • /
    • 2002
  • In this study, the results of a series of consolidation test for undisturbed Ariake clay in Japan were analyzed by three methods, e-log p (e: void ratio, p: consolidation pressure), log e-log p and n-log p (n: porosity). Moreover, the characteristics of each analysis method were studied. For undisturbed Ariake clay, the log o-Log p and the n-log p relationships can be found as two groups of straight lines of different gradients, but both the elastic consolidation and plastic consolidation regions of e-log p relationship are expressed as a curve. In this paper, the porosity of consolidation yield n$\_$y/, consolidation yield stress p$\_$y/, and the gradient of the plastic consolidation region C$\_$p/ were represented by the log e-log p method, and n$\_$c/, P$\_$cn/ and C$\_$cn/ were represented by the n-log p method. The meaning and the relationships of each value were studied, and the interrelationships among compression indices i.e. C$\_$cn/, C$\_$p/ and C$\_$c/ are obtained from each analysis method as a function of initial porosity n$\_$0/.

Multi-threaded system to support reconfigurable hardware accelerators on Zynq SoC (Zynq SoC에서 재구성 가능한 하드웨어 가속기를 지원하는 멀티쓰레딩 시스템 설계)

  • Shin, Hyeon-Jun;Lee, Joo-Heung
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.186-193
    • /
    • 2020
  • In this paper, we propose a multi-threading system to support reconfigurable hardware accelerators on Zynq SoC. We implement high-performance JPEG decoder with reconfigurable 2D IDCT hardware accelerators to achieve maximum performance available on the platform. In this system, up to four reconfigurable hardware accelerators synchronized with SW threads can be dynamically reconfigured to provide adaptive computing capabilities according to the given image resolution and the compression ratio. JPEG decoding is operated using images with resolutions 480p, 720p, 1080p at the compression ratio of 7:1-109:1. We show that significant performance improvements are achieved as the image resolution or the compression ratio increase. For 1080p resolution, the performance improvement is up to 79.11 times with throughput speed of 99 fps at the compression ratio 17:1.

Effect of Rib Pitch on Heat Transfer and Friction Factor in a Two Wall Divergent Channel (2벽면 확대 사각채널에서 리브 피치가 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo Whan;Lee, Myung Sung;Jeong, Seong Soo;Bae, Sung Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Experimental investigations of the heat transfer and friction factors in the ribbed divergent rectangular channel with the channel exit hydraulic diameter to inlet hydraulic diameter ratio of 1.16 were performed. The surface heaters were mounted onto the two opposite walls. The main experimental parameter is the ratio of rib pitch (p) to height (e), at which the ratios (p/e) of 6, 10, and 14 are considered in the channel with ribs on one wall only. The straight ribbed square channel is also considered as a comparison. The major findings are that the ratio of p/e = 6 shows the highest values in the heat transfer and the ratio of p/e = 10 indicates the greatest friction factor in the ribbed divergent channel. Editor's note:No major changes or corrections needed. Well written.

The Influence of Transcutaneous Electrical Stimulation on Autonomic Function (경피신경전기자극이 자율신경계에 미치는 영향)

  • Kang, Jong-Ho;Kim, Yong-Nam
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.4
    • /
    • pp.241-247
    • /
    • 2009
  • Purpose:The purpose of this study is to investigate the effect of transcutaneous electrical stimulation on autonomic nervous system using heart rate variability analysis. Methods:31 subjects were evaluated with HRV before and after a single high-frequency TENS for 15minutes treatment. The standard deviation of all the normal RR-interval(SDNN) and lower frequency/high frequency ratio(LF/HF ratio) were recorded with TAS-9. Results:After single TENS treatment, autonomic adaptation as analyzed by SDNN was increased from $42.47\pm12.96$ to $4.43\pm16.76$(p>0.05) and autonomic balance as analyzed by LF/HF ratio was increased from $1.4\pm0.45$ to $1.45\pm0.41$(p>0.05). Conclusion:In this study, SDNN and LF/HF ratio changed in health young students as a result of single TENS treatment. But there is no significant difference between pre-treatment and post-treatment of SDNN and LF/HF ratio.

  • PDF

Effects of Obesity on Presentation of Breast Cancer, Lymph Node Metastasis and Patient Survival: A Retrospective Review

  • Kaviani, Ahmad;Neishaboury, MohamadReza;Mohammadzadeh, Narjes;Ansari-Damavandi, Maryam;Jamei, Khatereh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2225-2229
    • /
    • 2013
  • Background: As data on the relation between obesity and lymph node ratio are missing in the literature, we here aimed to assess the impact of obesity on this parameter and other clinicopathological features of breast cancer cases and patient survival. Materials and Methods: Medical data of 646 patients, all referred to two centers in Tehran, Iran, were reviewed. Factors that showed significant association on univariate analysis were entered in a regression model. Kaplan-Meier and Cox-regression were employed for survival analysis. Results: Obesity was correlated with the expression of estrogen and progesterone receptor (p=0.004 and p=0.039, respectively), metastasis to axillary lymph nodes (p=0.017), higher lymph node rate (p<0.001) and larger tumor size (p<0.001). The effect of obesity was stronger in premenopausal women. There was no association between obesity and expression of human epidermal growth factor receptor. Three factors showed independent association with BMI on multivariate analysis; tumor size, estrogen receptor and lymph node ratio. Obesity was predictive of shorter disease-free survival with a hazard ratio of 3.324 (95%CI: 1.225-9.017) after controlling for the above-mentioned variables. Conclusions: The findings of this study support the idea that obese women experience more advanced disease with higher axillary lymph node ratio, and therefore higher stage at the time of diagnosis. Furthermore, obesity was associated with poorer survival independent of lymph node rate.

Comparison of various dietary intake assessment method in monitoring the adherence to fat-modified diet (저지방.저콜레스테롤 식이요법 환자군의 식이섭취실태 평가법에 대한 비교 연구)

  • 장남수
    • Journal of Nutrition and Health
    • /
    • v.22 no.6
    • /
    • pp.438-446
    • /
    • 1989
  • This study was designed to compare various dietary assessment methods and to determine the appropriate method that would be reliable for monitoring the adherence to a fat-modified diet. Dietary intake data was collected from the twenty-two (12 males, 10 females), type IIa hypercholesterolemic patients by the 24-hour dietary recall and the food records of various durations(9, 7, 4, 3days). Intakes of energy, protein, fat, carbohydrates, cholesterol, polyunsaturated fatty acids, saturated fatty acids, monounsaturated fatty acids, P/S ratio, and alcohol were analyzed by a computer-assisted method using the Natinal Heart, Lungand Blood Institute Nutrition Data System. The nutrient intake data of the 24-hour recall method were consistently higher than tat of the food record method. In all subjects, food record keeping of the 7 consecutive days provided acceptable dietary data (within 5% difference) when compared to that of the 9 consecutive days. Food records of 4 consecutive days however, were found to be adequate for female subjects, showing a sex difference. Except for P/S ratio, nutrient intakes did not vary significantly between weekdays and weekend-days. Among other components, alcohol and P/S ratio were shown to be the two most varied components in this study.

  • PDF

Comparison of Dissolved Air and Micro-Bubble Concentration by a Micro-Bubble Generating Pump (미세기포 발생 펌프에서 생성되는 기포농도와 용존공기농도의 비교)

  • Lee, Chang-Han;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1835-1842
    • /
    • 2014
  • The goal of this study was to evaluate micro-bubble concentration ($C_{air}$) in water by air/water ratio (A/W ratio) with a micro-bubble generating pump. The estimation of micro-bubble concentration is based on the balance of inlet/outlet air and water flow rate. On net A/W ratio to be generated micro-bubble, we found that the obtained the $C_{air}$ are shown as a function of discharge pressure ($P_g$) of the micro-bubble generating pump. The correlation of the $C_{air}$ and the $P_g$ ($C_{air}=3.261P_g-1.754$) was adequately described by the least square methods with a high correlation coefficient (r = 0.9459) and calculated values fit the experimental data quite well. The $C_{air}$ was lower than theoretical dissolved air concentration ($C_{aq}$) calculated by Henry's law. The $C_{air}$ for being operated the micro-bubble generating pump was 6.75 - 39.53 mL/L, however, we found that the optimum of the $C_{air}$ to generate micro-bubble was the range from 10 to 12 mL/L.

Effects of the dietary digestible fiber-to-starch ratio on pellet quality, growth and cecal microbiota of Angora rabbits

  • Yang, Guiqin;Zhao, Fei;Tian, He;Li, Jiantao;Guo, Dongxin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.4
    • /
    • pp.623-633
    • /
    • 2020
  • Objective: Substituting starch with digestible fiber (dF) can improve digestive health of rabbits and reduce costs. Therefore, it is necessary to develop a criterion for dF and starch supply. Effects of the dietary dF-to-starch ratio on pellet quality, growth and cecal microbiota of Angora rabbits were evaluated. Methods: Five isoenergetic and isoproteic diets with increasing dF/starch ratios (0.59, 0.66, 0.71, 1.05, and 1.44) were formulated. A total of 120 Angora rabbits with an average live weight of 2.19 kg were randomly divided into five groups with four replicates. At the end of 40 day feeding trial, cecal digesta were collected to analyse microbiota. Results: The results showed that the dF/starch ratio had linear effects on pellet variables (p<0.01). When the dF/starch ratio was 1.44, the pellets had the lowest powder and highest durability. The dF/starch ratio had unfavorable linear effects on growth variables (p<0.001). When analyzed by quadratic regression, the optimal dF/starch ratios for average weight gain and feed/gain were 0.59 and 0.74, respectively. There were differences in wool yield, fiber length and fiber diameter caused by the dF/starch ratio (p<0.05), and the dF/starch ratios that ranged from 0.66 to 1.06 were appropriate for good results. The cecal microbiota operational taxonomic unit (OTU) number index in the 1.05 dF/starch treatment was higher than that in the 0.66 and 0.71 dF/starch treatments. The higher dF/starch ratio resulted in a higher cecal microbiota OTU number index (p<0.05). The proportion of Ruminococcus in the 0.71 dF/starch treatment was higher than that in the 0.59 dF/starch treatment (p<0.05) Conclusion: The most suitable dF/starch ratio for feed pellet quality is 1.44, and for rabbit growth the optimal range of ratios is from 0.59 to 0.74. With combination of the wool growth, output cost, and cecal microbiota, we suggest that a dietary dF/starch ratio ranging from 0.74 to 1.06 is optimal.

A Study on the Guided Search Method for Transcoding MPEG2 P frame to H.263 P frame in a Compressed Domain (압축상태에서 MPEG2 P 프레임을 H.263 P 프레임으로 변환하기 위한 가이드 탐색 방법 연구)

  • Um, Sung-Min;Kang, Eui-Seon;Lim, Young-Wan;Hwang, Jae-Gak
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.745-752
    • /
    • 2002
  • The purpose of the paper is to enable a format transcoding between a heterogeneous compression format in a real time, and to enhance the compression ratio using characteristics of the compressed frame. In this paper, for the heterogeneous format transcoding, we tried to transcode from MPEG2 having a lower compression ratio to H.263 having a higher compression ratio. After analyzing MPEG 2 bit stream and H.263 bit stream of the same original video, we found that the number of intra coded macro blocks in MPEG 2 data is much higher than the number of the intra coded macro blocks in H.263 data. In the process of P frame generation, a intra coded macro block is generated when a motion estimation value representing the similarity between the previous frame and current frame does not meet a threshold. Especially the intra coded macro block has a great impact on the compression ratio. Hence the paper, we tried to minimize the number of intra coded macro blocks in H.263 data stream which is transcoded from MPEG 2 in a compressed domain. For the purpose, we propose a guided search method for transcoding the INTRA coded block into INTER coded block using the information about motion vectors surrounding the intra macro block in order to minimize the complexity of the motion estimation process. The experimental results show that the transcoding of MPEG 2 into H.263 can be done in a real time successfully.

A Report to Improve Satisfaction and Hospital Length of Stay of Gamma Knife Surgery Patients (감마나이프수술 환자의 만족도 및 재원일수에 대한 고찰)

  • Jeong, Sang Soon;Chung, Hyun-Tai;Paek, Sun Ha;Kim, Dong Gyu
    • Quality Improvement in Health Care
    • /
    • v.8 no.1
    • /
    • pp.74-83
    • /
    • 2001
  • Background : Since a Gamma Knife had been installed on December 1997, 405 patients have been treated until December 1999 at department of neurosurgery of Seoul National University hospital. The authors analyzed results of a work to improve satisfaction of Gamma Knife surgery patients and to reduce hospital length of stay. Methods : To understand main discontent of patients, a pre-survey was performed from October 1998 to December 1999 using a questionnaire. By Analyzing 93 questionnaire received from 234 patients, pain on frame application, explanation before surgery, waiting time before surgery, waiting time before medical procedure were main discontent factor and overall satisfaction ratio was 71.0%. To improve satisfaction ratio, several quality improvement activity works were designed and applied to 123 patients during the period between January 2000 and September 2000. The same questionnaire were analyzed. Works to reduce the patient hospital LOS were devised and applied during the same period. Results : The overall satisfaction ratio of Gamma Knife radiosurgery patients was increased to 83.7%(P=0.10). The main factor to improve satisfaction ratio was to reduce waiting time(P=0.05) and improvement of discomfort during the surgery(P=0.06). The average LOS was reduced from 3.1 to 2.7 days(P=0.003). Conclusion : As a result of quality assurance activities, the overall satisfaction ratio of patients was improved and LOS was reduced. The pain during frame application was remained as a main discontent factor and a further study is required to reduce this pain.

  • PDF