• 제목/요약/키워드: P+Resonant controller

검색결과 21건 처리시간 0.024초

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

비선형 부하를 고려한 배전용 정지형 보상기의 전류제어 기법 (Current Control Method of Distribution Static Compensator Considering Non-Linear Loads)

  • 김동근;최종우;김흥근
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1342-1348
    • /
    • 2009
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensated current and the other part is the current control. This paper proposes a proportional-resonant-repetitive current controller. Improved performance of instantaneous power compensation has been shown by simulations and experiments.

0.35 um 2P3M BCD 공정을 이용한 LLC 공진 제어 IC 설계 (A Design of LLC Resonant Controller IC in 0.35 um 2P3M BCD Process)

  • 조후현;홍성화;한대훈;천정인;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제47권5호
    • /
    • pp.71-79
    • /
    • 2010
  • 본 논문은 LLC 공진 제어 IC(Integrated Circuit) 설계에 관한 것이다. LLC 공진 제어 IC는 DC/DC 변환하기 위해서 외부의 공진 회로에 입력되는 주파수를 조정하여 트랜스포머를 통해서 2차 측의 출력 전압을 조정한다. 공진회로에 펄스를 공급하기 위한 클럭 생성기가 내장되어 있고, 클럭 주파수는 외부 저항을 사용하여 튜닝이 가능하다. 또한 외부 피드백 입력되는 전압을 이용해 주파수 조정이 가능하도록 VCO(Voltage Controlled Oscillator) 기능을 내장하였다. 동작의 신뢰성을 높이고 회로를 보호하기 위해서 UVLO(Under Voltage Lock Out), brown out, fault detector의 보호회로를 내장하였고, 입력 커패시턴스가 큰 용량의 IGBT(Insulated Gate Bipolar Transistor)를 구동하기 위해서 높은 전압, 전류의 제공이 가능한 HVG(High Side Driver), LVG(Low Side Driver) 드라이버 회로를 내장하였다. LLC 공진 제어 회로를 하나의 칩으로 구현하여 LLC 공진 회로를 제어하는데 있어 필요한 회로들을 설계하였다. 설계한 LLC 공진 제어 IC는 0.35 um 2P3M BCD 공정으로 제작하였다. 칩의 면적은 $1400um{\times}1450um$ 이고, 5V, 15V 두 가지의 전원 전압을 사용한다.

스위칭 소자의 전도손실과 스트레스를 저감하기 위한 디지털 위상천이 공진형 컨버터에 관한 연구 (A Study of the Digital Phase-shift Resonant Converter to Reduce the conduction Loss and Stress of the Switching Device)

  • 신동률;황영민;김동완;우정인
    • 전기학회논문지P
    • /
    • 제51권1호
    • /
    • pp.10-17
    • /
    • 2002
  • Due to the development of information communication field, the interest of the SMPS(Switched Mode Power Supply) is increased. The size and weight of SMPS are decided by inductor, capacitor and transformer. Thus, the low loss converter which is operated in high speed switching is required. The resonant FB DC-DC converter is able to operate in high speed switching and apply to high power field because the switching loss is low. In this thesis, it is proposed to control strategy for constant output power of resonant FB DC-DC converter in variable input voltage. The proposed control system is a digital I-PD type control and apply to phase-shift resonant type controller. The output voltage tracks reference without steady state error in variable input voltage. The validity of proposed control strategy is verified from results of simulation and experiment.

전력MOSFET를 이용한 고주파 공진형 DC-DC Converier의 설계와 해석에 관한 연구 (A Study on the Design and Analysis of H.F Resonant Converter using power MOSFET)

  • 차인수;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.510-514
    • /
    • 1989
  • This paper presents a new converter composed of a P.W.M controller and a resonant converter which operates at a constant frequency. This converter has relatively simple control circuits and high conversion efficiency. The optimum operating point corresponding to maximum efficient for the S.R.C and P.R.C operating above resonance is obtained.

  • PDF

UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구 (Control Strategy of Resonant DC Link Inverter for UPS)

  • 백주원;유동욱;민병권;류승표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

UPS 인버터의 성능 개선을 위한 강인한 2중 디지털 제어기의 설계 (Design of Robust Double Digital Controller to Improve Performance for UPS Inverter)

  • 박지호;노태균;김춘삼;안인모;우정인
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.116-127
    • /
    • 2003
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 채택하였다 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출련전압의 과도상태 응답특실을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 진압제어기를 제안하였다.

UPS 인버터의 디지털 제어기 및 모니터링 시스템의 개발 (Development of Digital Controller and Monitoring System for UPS Inverter)

  • 박지호;황기현;김동완
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 논문에서는 UPS 인버터의 성능 개선을 위하여 출력측 LC 필터의 커패시터 전압과 전류의 2중 제어루프를 구성하고, 2중 제어루프에 디지털 제어시스템을 설계하였다. 또한, 디지털 제어기의 연산지연시간을 보상하기 위하여 이러한 연산지연시간을 인버터 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. UPS 인버터 출력전압의 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 2중 제어루프에서 내부 전류 제어루프는 내부 모델 제어기를 제안하였다. UPS 인버터 출력전압의 0의 정상상태 오차를 얻기 위하여 외부 전압 제어루프는 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다. 또한, 사용자에게 쉽게 UPS의 동작 상태를 표시하기 위하여 그래픽 사용자 인터페이스를 이용한 UPS의 모니터링 시스템을 구현하였다.

오존발생장치용 정출력 전원장치의 개발 (Development of Constant Output Power Supply System for Ozonizer)

  • 우정인;우성훈;노인배;박지호;김동완
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.113-121
    • /
    • 2005
  • 본 논문에서는 오존발생장치의 전원측 파형에 포함되는 고주파수의 노이즈를 제거하고, 디지털 궤환 제어에 의해 오존 출력을 제어하기 위하여 전원장치의 출력측 LC 필터와 방전관 용량으로부터 커패시터 전압과 전류를 검출하여 2중의 제어루프를 설계하였다. 디지털 제어기의 연산지연시간을 보상하기 위하여 연산지연시간을 전원장치 플랜트의 고유한 파라미터로 가정하고, 플랜트 모델에 포함시켜 모델링 하였다. 오존발생장치의 부하변동에 따르는 과도상태 응답특성을 개선하고, 파라미터 변동에 강인한 특성을 얻기 위하여 내부 전류 모델 제어기를 제안하였다. 또한 오존발생장치용 전원장치에서 영 오차의 정상 상태를 얻기 위하여 외부 전압 제어루프를 구성하여 비례 제어기와 공진 제어기를 병렬로 연결한 비례-공진 전압제어기를 제안하였다.

광범위 입력전압을 갖는 준공진형 플라이백 파워서플라이의 연구 (A Study of Quasi-Resonant Flyback Power Supply with Very Wide Input Voltage)

  • 이용근;나재두
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.143-145
    • /
    • 2015
  • One of the many problems besetting the converter designer is being able to design a switching power supply that can operate in the range of very wide input voltage. Specially, in an emergency diesel generator system, the AVR(Automatic Voltage Regulator) is a regulator which regulates the output voltage of the generator at a nominal constant voltage level. In addition, the AVR must be operated in very wide input voltage. Therefore, a power supply for the AVR must be operated at the very wide input voltage range. In this paper, a quasi-resonant flyback power supply with very wide input voltage range is proposed. Also, the performance of the proposed power supply is demonstrated through experiments.