• Title/Summary/Keyword: P&G corporation

Search Result 195, Processing Time 0.025 seconds

Study on Consumer Exposure to Sun Spray and Sun Cream in South Korea

  • Oh, Mihyun;Kim, Seoyoung;Han, Jieun;Park, Sodam;Kim, Go Un;An, Susun
    • Toxicological Research
    • /
    • v.35 no.4
    • /
    • pp.389-394
    • /
    • 2019
  • When conducting risk assessments of cosmetic ingredients, it is important that reliable exposure information is obtained for cosmetic products. As cosmetics are becoming more diverse, continuous effort must be made to obtain exposure data that reflect their growth and usage trends. The usage pattern of cosmetics, such as the application area and amount used, may differ by product type and also by country. We conducted a survey to compare the amount of sun spray and sun cream used in a usage environment in South Korea. The study was conducted on Haeundae Beach, one of the most popular beaches in South Korea. A total of 1,255 beachgoers participated in this study; 604 and 651 participants used the sun spray and sun cream, respectively, while sunbathing and enjoying water activities on the beach for one day. Exposure was analyzed following a probabilistic method. On comparing all subjects, it was found that the group that used sun spray (mean: 44.52 g/day) used significantly more product (p = 0.000) than those who used sun cream (mean: 20.51 g/day). By analyzing the daily exposure of sun spray and sun cream per unit body weight according to age and gender, the exposure amount of sun spray and sun cream was found to be highest among 2~9 year-old girls (mean for sun spray: 2.51 g/kg/day, p95: 5.50 g/kg/day, mean for sun cream: 0.79 g/kg/day, p95: 1.79 g/kg/day). The amount of sun spray used is approximately twice that of sun cream. Among both the sun spray and sun cream groups, the exposure amount per unit body weight was highest in girls younger than 10. These factors should be considered when conducting risk assessments of sun spray and sun cream.

Distribution of Pollutant Content within Surface Sediment and Evaluation of Its Removal Efficiency in the Sihwa Constructed Wetland (시화호 인공습지에서 표층퇴적토의 오염물질 함량 분포와 제거효율 평가)

  • Choi, Don-Hyeok;Choi, Kwang-Soon;Kim, Dong-Sup;Kim, Sea-Won;Hwang, In-Seo;Lee, Mi-Kyung;Kang, Ho;Kim, Eun-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.755-764
    • /
    • 2009
  • To estimate the pollutant removal efficiency by surface sediment, matter content within surface sediment and its release from the sediment were investigated at 12 sites in the Sihwa constructed wetland. The content of COD, TOC, IL, TN, and TP within sediment varied temporally and spacially, showing ranges of 4.1~7.7 mg/g, 0.29~2.81%, 1.88~8.15%, 0.03~0.35%, 362~1,150 ${\mu}g$/g, respectively. The contents of organic matter and TN were significantly highest in March and decreased towards fall (March${\geq}$May${\geq}$July${\geq}$September, p=0.003 for COD, p=0.001 for TOC, p=0.017 for IL, p=0.015 for TN), whereas TP content was not significant statistically in difference between sampling times. The contents of heavy metals also varied largely with sampling sites and times (As:3.5~3.9 ${\mu}g$/g, Cd:0.08~0.38 ${\mu}g$/g, Cr:51.8~107.0 ${\mu}g$/g, Cu:16.4~81.8 ${\mu}g$/g, Pb:26.~81.8 ${\mu}g$/g, Zn:85~559 ${\mu}g$/g). As compared with sediment quality guideline, the content of organic matter within surface sediment of the Sihwa constructed wetland was classified as unpolluted level. In contrast, the contents of TN, TP and heavy metals were classified as medium or severe pollution state, except some heavy metals (Cu and Pb). From the results of release experiment, TN, Pb, and Zn tend to be removed by surface sediment, but TP, Cd, and Cu have a tendency to released from sediment. Therefore, a relevant plan to improve the removal efficiency of pollutant (especially phosphorus) by surface sediment in the Sihwa constructed wetland is needed.

The Study of Radon Activity and Uranium Concentration of Ground Water and Surface Water (지하수와 지표수에서의 라돈 및 우라늄의 실태 조사)

  • Oh, Youngmi;Lee, Jongbok;Shin, Kyungjin;Kim, Hakchul;Lee, Jaehee;Hwang, Sangchul;Jung, Sanggi;Lee, Sangtae
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.201-205
    • /
    • 2007
  • This paper reports the amount of $^{222}Rn$ and $^{238}U$ in 18 sites of ground water and 30 sites of surface water. The instrument used to count $^{222}Rn$ activity was the liquid scintillation counter (LSC) which could resolute ${\alpha}$ and ${\beta}$ radiations. And $^{238}U$ was analyzed by the inductively coupled plasma (ICP). Radon and Uranium were not detected in raw and treated water which were sampled in a water treatment plant. However, radon ($^{222}Rn$) was high concentration in ground water from Jeon-la, Gang-won. So was uranium ($^{238}U$) in case of ground water from Gang-won, Choong-chung. Radon ($^{222}Rn$) activities were detected less than 15 pCi/L at 5 sampling points, 15~300 pCi/L at 7 sampling points, 300~4000 pCi/L at 6 sampling points. However, Radon ($^{222}Rn$) activities of all ground water samples were less than 4,000 pCi/L, which was bellow American Alternative Maximum Contamination Level (AMCL). Uranium ($^{238}U$) concentrations were less than $0.1{\mu}g/L$ at 5 sampling points, from $0.1{\mu}g/L$ to $20{\mu}g/L$ at 13 sampling points. Uranium was not detected in about 30% of the whole samples, but the concentration ranged from relatively low to high concentrations depending on the sampling point. The minimum detectable activity (MDA) of radon was 15 pCi/L. and the detection limit of uranium was $0.1{\mu}g/L$.

A Study on the manufacturing Composite Insulator for 170kV D/S (170kV급 단로기용 Composite Insulator 제조기술에 관한 연구)

  • Jin, S.Y.;Bae, K.S.;Lee, D.W.;Song, W.P.;Song, H.S.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.34-36
    • /
    • 2002
  • The objective of this study is to develop the composite insulator for 170kA disconnecting switch. In this paper, we have investigated the test procedure about each component(FRP tube, flange, shed) through technical standard(IEC 61462) and obtained demand characteristics by mechanical & electrical property test.

  • PDF

Optimal Design of Urban MICROGRID using Economical Analysis Program (경제성분석 프로그램을 이용한 도심형 마이크로그리드 최적 설계)

  • Seung-Duck, Yu;SungWoo, Yim;Youseok, Lim;SungWook, Hwang;JuHak, Lee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.69-72
    • /
    • 2022
  • This paper actually investigates the load on major large-scale buildings in the downtown area, examines the economic feasibility of installing PV and ESS in a microgrid target building, and evaluates whether an electric vehicle capable of V2G through two buildings is effective as an economical analysis program (HOMER) was analyzed using. It is economical to install a mixture of ESS rather than using the whole PV, and it is shown that if there is an electric vehicle using the V2G function of EV, there is an economic effect to replace the PV. So that Incentives and policies are needed to replace a large area of PV and utilize the existing parking lot to lead EV as a resource of the microgrid. Currently, P2X technology that stores power as ESS or converts it to other energy to control when surplus renewable energy occurs in large-capacity solar power plants and wind farms, etc. This is being applied, and efforts are being made to maintain the stability of the system through the management of surplus power, such as replacing thermal energy through a heat pump. Due to the increase in electric vehicles, which were recognized only as a means of transportation, technologies for using electric vehicles are developing. Accordingly, existing gas stations do not only supply traditional chemical fuels, but electricity, and super stations that also produce electricity have appeared. Super Station is a new concept power plant that can produce and store electricity using solar power, ESS, V2G, and P2G. To take advantage of this, research on an urban microgrid that forms an independent system by tying a large building and several buildings together and supplies power through a super station around the microgrid is in full swing.

Surface Densification Coupled with Higher Density Processes Targeting High-performance Gearing

  • Hanejko, Francis;Rawlings, Arthur;King, Patrick;Poszmik, George
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.738-739
    • /
    • 2006
  • This paper will describe a powder and processing method that facilitates single press-single sintered densities approaching $7.5g/cm^3$. At this sintered density, mechanical properties of the powder metal (P/M) component are significantly improved over current P/M technologies and begin to approach the performance of wrought steels. High performance gears have the added requirement of rolling contact fatigue durability that is dependent upon localized density and thermal processing. Combining high density processing of engineered P/M materials with selective surface densification enables powder metal components to achieve rolling contact fatigue durability and mechanical property performance that satisfy the performance requirements of many high strength automotive transmission gears. Data will be presented that document P/M part performance in comparison to conventional wrought steel grades.

  • PDF

Construction of Simple Synthetic Testing Facility Using LC Resonance Circuit (L-C 공진회로를 이용한 대용량 간이 합성시험 설비 구축)

  • Kwon, G.J.;Kim, D.S.;Song, W.P.;Kwon, G.Y.;Chung, J.M.;Park, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.409-411
    • /
    • 1999
  • This paper proposes the circuit of the simple synthetic testing facility using LC resonance circuit. EMTP has been used to analyze the circuit. The obtained results indicate that the simple synthetic testing facility using LC resonance circuit can be easily designed and used very usefully for the research and development for the switchgears.

  • PDF

The Study on the Removal Process of Heavy Metals from Mine Drainage Using Coal Bottom Ash (석탄 바닥회를 이용한 광산배수의 중금속 제거 공정 연구)

  • Kim, Hye Rim;Lee, Jung Mi;Han, In Kyu
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.41-47
    • /
    • 2020
  • This study was carried out to utilize the coal bottom ash generated in a circulating fluidized bed combustion boiler as a treatment agent for heavy metal ions, and experiments were conducted to remove heavy metal ions from the acid mine drainage. The batch experiments were conducted to investigate the influence of dosage of ash, initial concentration of solution on the removal capacity of heavy metal ions (Cu, Cd, Cr, Pb). The results of the experiment showed that the total removal capacity of heavy metals was 30.8 mg/L and 46.4 mg/g, respectively, under the condition that the concentration of coal ash was added as 15 g/L of heavy materials and 10 g/L of light materials. After that, a long-term column experiment was performed to determine the maximum removal capacity of heavy metal ions (Cu, Cd, Cr, Pb, As), and the removal capacity for each metal component was investigated. After approximately 60 days of operation, the maximum removal capacity of heavy metals was 23.6 mg/g at pH 9.25.

Serum Immunoglobulin Levels in Coal Workers' Pneumoconiosis (탄광부진폐증자의 혈청 면역단백 농도에 관한 연구)

  • Chung, Ho-Keun;Cheon, Yong-Hee;Hong, Jeong-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.247-254
    • /
    • 1987
  • Serum immunoglobulin(Ig)A, IgG, IgM, levels were measured in 99 coal workers' pneumoconiosis (CWP) patients and 12 healthy coal workers and 9 non-miners to compare with each group by the radiological categories, its complications and working period in coal mine. Serum were measured by nephelometry, The findings were as follows: 1) Serum IgA levels were significantly different between three groups of CWP patient, healthy coal worker and non-miner ($mean{\pm}standard$ deviation: $226.4{\pm}87.7,\;221.3{\pm}45.1,\;170.1{\pm}65.7$ respectively). 2) There were no significant differences of Ig levels among radiological categories of CWP. 3) There were no significant differences of Ig levels among simple pneumoconiosis and its complicated disorders. 4) The three Ig levels were slightly increased in the group of mining years less than 20 years (IgA: r=0.1869, p<0.10 IgG: r=0.2902, p<0.05 IgM: r=0.2889, p<0.05).

  • PDF

Management Plan for Rural Groundwater Resources in the Era of Post COVID-19 (포스트 코로나 시대 농어촌지하수 관리 방안)

  • Lee, Byung Sun;Seo, Sangjin;Lee, Gyusang;Yoon, Seok-Hwan;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.4
    • /
    • pp.1-9
    • /
    • 2022
  • This study was conducted to supplement new-normal strategies on management plans of rural groundwater resources in the era of Post COVID-19. Global outbreak of COVID-19 has damaged across all areas including public policy, economics, industrial services, and others without exception, which has resulted in establishing new-normal strategies in order to restore balance and functions as for these areas. The new-normal ones were represented as enhancing preventative management on infectious diseases, expanding non face-to-face services, enhancing protective trades and food securities, and preparing growth policies on public services using the 4th industrial revolution techniques. In this study, G-WASH_AD (Groundwater supply, sanitation, and hygiene with attraction and digitization) was suggested to be new-normal strategies on rural groundwater resources. The G-WASH_AD was consisted of three detailed action plans: a preventative plan on waterborne-diseases of groundwater (PP), a groundwater-tourism plan with rural heritage (GP), and an application plan of the 4th industrial revolution techniques to groundwater facilities and its data (P4). The PP can contribute to protect human health from waterborne-diseases and minimize hazardous effects on crop cultivation. The GP accompanied with high-quality groundwater resources is able to strengthen rural tourism, to promote marketing activities on local agricultural products, and to increase household incomes of rural communities. The P4 can reinforce fast, comfortable, and scientific management on groundwater facilities and its data, creating a virtuous cycle between innovative management on groundwater and growth of technology related to it. Results of the G-WASH_AD strategies can encourage a green growth engine in field of rural groundwater management keeping up with Post COVID-19.