• 제목/요약/키워드: Ozone pollution

검색결과 389건 처리시간 0.025초

CB4를 이용하여 부산 지역의 오존 전구 물질의 배출량에 대한 오존 농도의 민감도 (Sensitivity of Ozone Concentrations to Ozone Precursor Emissions In Busan Metropolitan Area Using the Carbon Bond Mechanism IV)

  • Lee, Hwa-Woon;Roh, Soon-A;Kim, Heon-Sook
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.362-363
    • /
    • 2003
  • Photochemical ozone is formed from nitrogen oxides (NOx) and volatile organic compounds(VOCs) through non-linear interactions between chemical reactions and meteorology, and the relationship between precursors and photochemical ozone will be changed to match the emission distribution and meteorological fields. It is generally known that for some conditions the process of ozone formation is controlled almost entirely by NOx and is largely independent of VOC, while for other conditions ozone production increases with increasing VOC and does not increase(or sometimes even decreases) with increasing NOx (omitted)

  • PDF

GMAP 2021 캠페인 기간 용인지역 오존 연직 분포 관측 (The Observation of Ozone Vertical Profile in Yongin, Korea During the GMAP 2021 Field Campaign)

  • 류호선;구자호;김형규;이나현;이원진;김주완
    • 대기
    • /
    • 제32권3호
    • /
    • pp.247-261
    • /
    • 2022
  • The importance of ozone monitoring has been growing due to the polar ozone depletion and increasing tropospheric ozone concentration over many Asian countries, including South Korea. In-situ measurement of the vertical ozone structure has advantages for ozone research, but observations are not sufficient. In this study, ozonesonde measurements were performed from October to November in Yongin during the GMAP (The GEMS Map of Air Pollution) 2021 campaign. The procedure for ozonesonde preparation and initial analysis of the observed ozone profile are documented. The observed ozone concentrations are in good agreement with previous studies in the troposphere, and they capture the stratospheric ozone distribution as well, including stratosphere-troposphere exchange event. These balloon-borne in situ measurements can contribute to the evaluation of remote sensing measurements such as Geostationary Environment Monitoring Spectrometer (GEMS). This document focuses on providing essential information of ozonesonde preparation and measurement for domestic researchers.

콘크리트 표면처리방법에 따른 금속용사 피막의 투수성 평가에 관한 실험적 연구 (An Experimental Study on the Permeability Evaluation of Metal Spray System by Concrete Surface Treatment)

  • 박진호;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.34-35
    • /
    • 2015
  • Recently, introduction of Advanced water treatment facilities has been increasing due to serious domestic water pollution. Ozone is a strong oxidizing materials in the advanced water treatment facilities. However, due to such a strong oxidation, Ozone eroded waterproofing/corrosion on the concrete surface and caused performance degradation. Therefore, in this study, permeability experiment of metal spraying system by concrete surface treatment was conducted.

  • PDF

해수면으로의 오존침적 (Ozone deposition to the sea surface)

  • Jang Won-Il;Lee Mi-Hye
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.121-122
    • /
    • 2003
  • Deposition to the sea surface is one of ozone's principal loss mechanisms (Galbally and Roy, 1980; Levy et al., 1985; Kramm, 1995). However, since complicated physical and chemical processes are involved, large uncertainties remain in evaluating this loss mechanism that need to be better characterized. In this study we attempted to explore possible causes that give rise to large variability of ozone deposition velocity in terms of wind speed and chemical reactivity in the aqueous-phase film. (omitted)

  • PDF

오존발생기와 저온 유전체장벽 플라즈마를 이용한 오존 발생 및 살균력 (Disinfective Properties and Ozone Concentrations in Water and Air from an Ozone Generator and a Low-temperature Dielectric Barrier Discharge Plasma Generator)

  • 이영식;전형주;한형균;정정조
    • 한국환경과학회지
    • /
    • 제22권8호
    • /
    • pp.937-944
    • /
    • 2013
  • Ozone concentrations in water and air, and resulting disinfective properties, were measured following generation by either an ozone generator or a low-temperature dielectric barrier discharge plasma generator. In freshwater, ozone concentrations of 0.81 and 0.48 mg/L $O_3$ were observed after the ozone and plasma generators had been operated for five minutes, respectively. Higher levels of dissolved $O_3$ were attained more easily with the ozone generator. In seawater, both systems were capable of creating concentrations greater than 3.00 mg/L $O_3$ after 5minutes of operation. Higher ozone levels were attained more easily in seawater than in freshwater. Rates of bacterial sterilization in seawater after three minutes were 96% and 88%, using the plasma and ozone generators, respectively. In freshwater, higher concentrations of ozone were released into the atmosphere by the ozone generator than by the plasma generator. In creating equivalent levels of dissolved ozone in freshwater, the plasma generator released 4.5 times more ozone into the atmosphere than did the ozone generator. This shows that ozone generators are more effective than plasma generators for creating ozonated water. For the same concentration of dissolved ozone in seawater, more ozone was released into the atmosphere using the ozone generator than using the plasma generator. Therefore, with regard to air pollution, plasma generators seem to be less expensive than ozone generators.

오존 SRP의 제작과 측정 불확도 평가 (Development of a Candidate Equipment for Ozone SRP and its Uncertainty Evaluation)

  • 정규백;우진춘;이진홍
    • 한국대기환경학회지
    • /
    • 제17권4호
    • /
    • pp.313-319
    • /
    • 2001
  • The development of ozone SRP (Standard Reference Photometer) designated as a G-7 project by the Korean Ministry of Environment began 1997 and is now nearly completed. With the completion of the ozone SRP we will not only acquire a qualification to participate in the international ozone calibration system but also enhance calibration credibility of ozone similarly to that of other ambient air pollution monitors. As the ozone SRP uses highly cleaned blank air that can be distinguished from general ozone analyzer, it is possible to reduce errors associated with the determination of ozone via elongation of the absorption length as long as 1 meter In addition, gas chopping method hat been adopted to cut down interference of other substances and time drift. Furthermore, the system has also been modified to minimize the strayed ultra-violet noise along the light path. In this paper, a new method for uncertainty evaluation has been introduced, which is guided by the ISO (International Standard Organization) GUM (Guide to the Expression of Uncertainty in Measurement) through assessments of the uncertainty type B (that was impossible to estimate before) as well as the uncertainty type A (based on statistics).

  • PDF

A Commentary on Air Pollution Monitoring Programs in Korea

  • Ghim, Young-Sung;Kim, Jin-Young;Shim, Shang-Gyoo;Moon, Kill-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E1호
    • /
    • pp.21-28
    • /
    • 2002
  • Air quality issues in Korea rapidly changed at the beginning of the 1990s from primary to secondary pollutants starting in Seoul, the capital of Korea. The present frame of national air pollution monitoring networks was established between the end of the 1980s and the beginning of the 1990s. Background monitoring was initiated in the middle of the 1990s in response to increasing public concern about the long-range transport of air pollutants. Apart from the national monitoring, both routine and intensive measurements of fine particles have been made for research purposes since the middle of the 1990s at several background sites. However, air pollution monitoring in urban areas for other purposes was relatively scarce as national monitoring has been concentrated in these areas. Although ozone pollution has become a significant issue in major metropolitan areas every summer, only a little information on ozone precursors is available. During the past few years, the number of national monitoring stations has greatly increased. The government has a plan to gradually expand monitoring items as well as stations. It is anticipated that highly detailed information on both photochemical reactants and products will be available within the next several years. More emphasis will be placed on toxic substances based on risk assessment in monitoring for both research and policy making.

대기오염 수준이 교통수단별 통행시간에 미치는 영향 분석 (The Impact of Air Quality on Traveling Time by Transportation Mode)

  • 조은정;김현철
    • 자원ㆍ환경경제연구
    • /
    • 제30권2호
    • /
    • pp.207-235
    • /
    • 2021
  • 본 논문은 오존과 미세먼지 수준이 도보, 자가용, 버스, 전철의 통행시간에 미치는 영향을 분석한다. 가구통행실태조사 자료와 SUR 모형을 이용하여 분석한 결과, 대기오염 농도가 높아질수록 자가용 통행시간이 증가하고, 버스의 통행시간이 감소하는 것으로 나타난다. 그러나 대기오염 경보가 발령되면 버스의 통행시간이 증가하는 공익적 행위가 일부 나타나지만, 자가용의 통행시간이 증가하거나 변화가 없고, 전철의 통행시간이 증가하지 않는 것으로 나타난다. 이는 경보의 발령으로 제공되는 정보가 배출 저감을 위한 통행행태 변화보다는 오염상황에의 노출을 줄이는 회피행동에 더 큰 영향을 미쳤음을 시사한다.

경기도 남부지역 지표오존농도의 시계열모형 연구 (Analysis of Time Series Models for Ozone at the Southern Part of Gyeonggi-Do in Korea)

  • 이훈자
    • 한국대기환경학회지
    • /
    • 제23권3호
    • /
    • pp.364-372
    • /
    • 2007
  • The ozone concentration is one of the important environmental issue for measurement of the atmospheric condition of the country. In this article, two time series ARE models, the direct ARE model and applied ARE model have been considered for analyzing the ozone data at southern part of the Gyeonggi-Do, Pyeongtaek, Osan and Suwon monitoring sites in Korea. The result shows that the direct ARE model is better suited for describing the ozone concentration in all three sites. In both of the ARE models, eight meteorological variables and four pollution variables are used as the explanatory variables. Also the high level of ozone data (over 80 ppb) have been analyzed at the Pyeongtaek, Osan and Suwon monitoring sites.

오존간이 측정기에 대한 연구(II)-간섭현상 및 현장 적용성 (A Study on Ozone Passive Sampler (II) -Interference and Field Application)

  • 정상진;양희준
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.904-911
    • /
    • 2006
  • Passive sampler is simple and inexpensive measuring equipment for air pollution. In this study we developed colorimetric ozone passive sampler which was coated a colorimetric reagent to a filter substrate. Interference of criteria all pollutant ($SO_2,\;NO_2,\;CO$) on ozone passive sampler was investigated through experimental chamber. Field measurement of developed ozone passive samper was compared automatic sampler result in Suwon area. The results shows interference of $SO_2$ gas is larger than other gases. Developed passive sampler can be roughly applicable to wind speed range from 0.8 to 3.3 m/s, temperature range from 3.9 to $27.5^{\circ}C$ and relative humidity range from 48 to 84%.