• Title/Summary/Keyword: Ozone environment

Search Result 693, Processing Time 0.026 seconds

Yearly Variation and Influencing Factors of Ozone Concentration in the Ambient Air of Seoul (서울시 대기중 오존오염도의 연도별 변화와 그 영향인자 분석: 광화문 지역을 중심으로)

  • Lee, Ki-Won;Kwon, Sook-Pyo;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.107-115
    • /
    • 1993
  • This study was carried out to find the characteristics of surface ozone concentration data obtained during 1988-1991 by the Korea Ministry of Environment. Seasonal data (spring, summer, autumn and winter) wre obtained in May, August, November and February respectively at Kwanghwamun in Seoul. The pollutants analyzed in this study are $SO_2, TSP, CO, NO, NO_2 and NO_2/NO$. Atmospheric factors such as solar radiation, wind speed, relative humidity, cloud amount and atmospheric temperature are also analyzed. The influence of pollutants and atmospheric factors that affect ozone concentration were analyzed by statistical method. The results are summarized as follows : 1. The ozone concentration varied seasonally. The maximum values were 23 ppb in spring, 33 ppb in summer, 16 ppb in autumn and 13 ppb in winter. So the seasonal ozone value was highest in Summer. 2. Te diurnal concentration of ozone was highest during 2-4 P. M. and was very low in the morning and evening. 3. The maximal correlation coefficients of each season between ozone concentration and the influencing pollutants or atmospheric factors asr as follows ; a. spring, r = 0.44(solar radiation) b. summer, r = -0.59(relative humidity) c. autumn, r = -0.55(relative humidity) d. winter, r = -0.58($NO_2$) 4. The major factor affecting the ozone concentration in spring was solar radiation, Relative humidity was the first affecting factor in summer, autumn and $NO_2$ concentration was dominant in winter.

  • PDF

Seasonal and Diurnal Variations of Surface Ozone at Ieodo in the East China Sea (이어도 해양과학기지의 오존농도의 계절변화와 일변화 특징)

  • Shin, Beom-Cheol;Lee, Mee-Hye;Lee, Jae-Hak;Shim, Jae-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.631-639
    • /
    • 2007
  • We examined diurnal and seasonal variations of ozone ($O_3$) concentrations and its relation to meteorological parameters observed at the Ieodo Ocean Research Station ($32.07^{\circ}N$, $125.10^{\circ}E$, 36 m above sea level) during June 2003 and May 2005. Over the 2-year period, the mean ozone concentration was $49.5{\pm}15.5\;ppbv$. Ozone concentrations show great variability with a monthly mean up to 68.2 ppbv in May 2005 and seasonal variations with being highest in spring and fall, and lowest in summer. However, the amplitude of diurnal variation was less than ${\sim}4\;ppbv$ with a maximum at $3{\sim}4\;p.m.$ and minimum at $7{\sim}8\;a.m.$ HYSPLIT backward air trajectory indicated that the air masses with higher ozone came from the north or northwest and those with lower ozone arrived mainly via southerly or southeasterly. Ozone distributions at Ieodo Ocean Research Station were observed to be significantly impacted by long-range transport and regional scale air circulation.

Effect of Surface Ozone on Vegetation in Korea - Preliminary Study on Early Foliage of Robinia pseudo-acacia - (한국의 지면 오존이 식생에 미치는 영향에 관한 연구 - 아까시나무 조기낙엽 현상과 관련성 검토 예비 연구 -)

  • Cho, Seog-Yeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.1
    • /
    • pp.29-38
    • /
    • 2007
  • Recently, the tropospheric ozone has gained a global attention for its adverse effect on vegetation as well as its contribution to the global warming. Although a number of studies have been carried out for the urban ozone, the effect of ozone on vegetation is still largely unknown in Korea. The present work aimed at performing the first evaluation of forest damage by ozone using the national air monitoring data from the year 2000 to the year 2005. Moreover, it also explored the relevance of adverse effect of ozone to the recent events on leaf chlorosis of black locust, Robinia pseudo-acacia, leading to early foliage widely observed in Korea since 2001. In the nineties, forest damages caused by ozone such as leaf chlorosis occurred in Europe and North America and led to invoke comprehensive field and laboratory studies. As a result, AOT40, implying the accumulated dose over a threshold 40 ppb, was developed to assess the forest damage by ozone. 19 air monitoring stations were selected across Korea to calculate AOT40 from the year 2000 to the year 2005. The calculated AOT40 generally increased during April and May and reached the maximum after May. The increase of AOT40 diminished substantially from the mid-June as the rainy season started. The calculated AOT40 in the nine rural sites from the year 2002 to th ε year 2005 ranged from 6.8 to 29.4 ppm-hr. And all the AOT40 at th ε year 2005 exceeded the critical value of 10 ppm-hr for forest damage. Morevoer the calculated AOT40 of Korea appeared higher than the AOT40 of Europe in the year 2004/2005 and comparable to the AOT40 of China in the year 2000. Despite the high levels of the calculated AOT40 since the year 2001 and the consistency of time of seasons between high AOT40 values and occurrence of chlorosis of black locust, further studies are required to conclude that the chlorosis of black locust occurred from the year 2001 to the year 2005 were resulted from a damage by ozone.

An Analysis of Influencing Factors on Ozone Concentration in the Ambient Air in Seoul (서울시 대기중 오존의 오염도와 그 영향인자 분석)

  • Chung, Yong;Jang, Jae-Yeon;Kwon, Sook-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.73-79
    • /
    • 1986
  • This study is carried out to determine the concentration of the ozone and the factors affecting the variation of ozone concentration in the ambient air in Seoul. The one-hour average concentration of ozone $(O_3)$, sulfur dioxide $(SO_2)$, nitrogen oxides (NO and $NO_2$), suspended particulate (TSP), carbon monoxide (CO) and non-methane hydrocarbon (NMHC) at 5 sites in Seoul measured from September to October in 1983 and 1984 were analysed statistically along with meteorological data for the same period. The results were as follows; 1. The average concentrations of ozone at 5 sites during the period ranged from 3.3 to 9.1 ppb, they were below 20 ppb of the ambient air quality standard of Korea. 2. The maximum hourly concentration of ozone occurred between 2 and 3 p.m. in a day and concentration at night were very low but higher concentrations were observed at around 4 a.m. 3. The concentration ratio between NO and $NO_2$ in Seoul was relatively lower than that for the cities of foreign countries reported so far. 4. The ozone concentration has negative correlationships with the concentration of other primary pollutants$(SO_2, NO, NO_2, CO and NMHC)$ in simple regression analyses. 5. The ozone concentration was positively correlated to wind speed, temperature and insolation intensity but negatively correlated to relative humidity. 6. Stepwise multiple regression analysis of the ozone concentration to the pollutants and meteorological factors indicate that insolation intensity and $[NO_2]/[NO]$ were the primary influencing factors. 7. The three factors of insolation intensity, $[NO_2]/[NO] and NO_2$ concentration had a significant combined effect on the ozone concentration $(r^2 = 0.47-0.57)$.

  • PDF

A Study on the Effect of Cumulus Parameterization and Microphysics on Ozone Simulations during Long-range Transport Process over Northeast Asia (동북아 장거리 수송 과정에서 적운 모수화 및 미세물리과정이 오존 모사농도에 미치는 영향 연구)

  • Kang, Jeong-Eon;Kim, Cheol-Hee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.135-151
    • /
    • 2013
  • This study has been carried out to analyze the sensitivity of ozone concentrations by employing different options of cumulus parameterization schemes (CPSs) and microphysics schemes in MM5 models. These sensitivity tests were applied to long-range transport case of higher ozone over Northeast Asia. Employed CPS schemes are Betts-Miller (BM), Grell (GR), Kain-Fritsch2 (KF2), Anthes-Kuo (AK), None scheme (grid scale physics only), and four microphysics used here are Simple ice, Reisner1, Reisner2, Schultz scheme in MM5. We chose two cases of high ozone long range transport case by employing both concentrations ozone level and backward trajectory model. The results showed that modeled ozone concentrations indicated about 10% differences among CPSs. Of the all options, GR and KF2 (for CPS), and Rersiner-1 and Resiner-2 (for microphysics) showed relatively good and stable variations against ensemble mean values. For both CPS and microphysics schemes, the difference of precipitation arising from different parameterization schemes was significant by itself, but the resultant ozone variations showed only marginal. But the cloud fraction differences arising from different parameterization schemes showed better correlation with ozone variations than precipitation differences, indicating that the photochemical ozone generation variations is more dominant by cloud fraction than wet removal process for high and long-ranged transported ozone cases over Northeast Asia.

Study on the Characteristics of Surface Ozone Distributions and the Ozone Critical Levels to Vegetation in the South Korea (남한 지역의 지면 오존 농도 특성과 식생에 대한 임계값 적용 연구)

  • Koo, Hae-Jung;Park, Soon-Ung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.310-320
    • /
    • 2008
  • Concentration of tropospheric ozone ($O_3$) was investigated for the South Korea. And then the critical ozone levels, expressed as AOT40 (Accumulated exposure over a threshold of 40 ppb) to vegetation have been used in this region within the UNECE (United Nations Economic Commission for Europe) Convention on Long-Range Trans-boundary Air Pollution (CLRTAP). Hourly ozone concentration data from 1996 to 2001 at 26 air monitoring stations was used to estimate the exceedance of the critical levels. It was calculated for daylight hours for each station, and mapped using surface interpolation over the South Korea. The critical levels of ozone have shown the highly exceeded value in the Gyeonggi region, southern coastal region and central inland of the South Korea. It was some different from the typical ozone distribution which represented highly in the western inland and coastal regions. The area exceeding the critical level for crops was founded to be more than 40% of the whole South Korean territory. While that for trees was to be about 17% of the South Korea. The critical ozone critical level was based upon data from experiments on specific species, and thus may not be fully representative for all types of vegetation. Nevertheless, the critical level and its exceedance of the ozone concentration would be one of the useful tools for international agreements on abatement strategies to prevent ecosystem damage.

Prediction of Cryptosporidium parvum Inactivation in Advanced Ozone Drinking Water Treatment with Lab Scale Experiments (실험실 규모 크립토스포리디움의 불활성화 실험을 통한 오존 고도정수처리 정수장에서 소독 효과 예측)

  • Cho, Min;Chung, Hyenmi;Kim, Reeho;Shon, Jinsik;Park, Sangjung;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • With the appearance of pathogenic microorganisms, which were resistant to free chlorine, the significant attention to the necessity of powerful alternative disinfection methods such as ozone, chlorine dioxide, LTV irradiation to inactivating pathogens has been increased in water treatment. Among these alternative disinfection methods, ozone is well known as strong biocidal method and the usage of ozone is also increasing in Korea. However, in Korea, there has been no report on the quantitative study of Cryptosporidium parvum with ozone and its evaluation in advanced drinking water treatments. This study reports on the methodology for predicting the ozone inactivation of Cryptosporidium parvum by ozone disinfection in advanced drinking water treatment. The method is based on the fact that a specific inactivation level of microorganisms is achieved at a unique value of ozone exposures, independent of ozone dose and type of water, and quantitatively described by a delayed Chick-Watson model. The required values ${\bar{C}}T$ for 2 log inactivation of Cryptosporidium parvum was $6.0mg/L{\cdot}min$ and $15.5mg/L{\cdot}min$ at $20^{\circ}C$ and $5^{\circ}C$, respectively. From this obtained Cryptosporidium parvum inactivation curves and calculated ${\bar{C}}T$ values of advanced drinking water treatment water in Korea with FIA (Flow injection alaysis), we can predict that water treatment plant can achieve a 1.1~1.8 log inactivation and 0~0.4 log inactivation at $20^{\circ}C$ and $5^{\circ}C$, respectively. This methodology will be useful for drinking water treatment plants which intend to evaluate the disinfection efficiencies of their ozonation process without full scale test and direct experiments with Cryptosporidium parvum.

Evaluation of Remediation Efficiency of In-Situ Chemical Oxidation Technology Applying Micro Bubble Ozone Oxidizer Coupled with Pneumatic Fracturing Equipment (마이크로버블 오존 산화제와 공압파쇄 장치를 연계 적용한 지중 화학적 산화법의 정화효율 평가)

  • Oh, Seung-Taek;Oh, Cham-Teut;Kim, Guk-Jin;Seok, So-Hee;Kim, Chul-Kyung;Lim, Jin-Hwan;Ryu, Jae-Bong;Chang, Yoon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.44-50
    • /
    • 2012
  • A new type of chemical oxidation technology utilizing micro bubble ozone oxidizer and a pneumatic fracturing equipment was developed to enhance field applicability of a traditional chemical oxidation technology using hydrogen peroxide as an oxidizer for in-situ soil remediation. To find an efficient way to dissolve gaseous ozone into hydrogen peroxide, ozone was injected into water as micro bubble form then dissolved ozone concentration and its duration time were measured compared to those of simple aeration of gaseous ozone. As a result, dissolved ozone concentration in water increased by 31% (1.6 ppm ${\rightarrow}$ 2.1 ppm) and elapsed time for which maximum ozone concentration decreased by half lengthened from 9 min to 33 min. When the developed pneumatic fracturing technology was applied in sandy loam, cracks were developed and grown in soil for 5~30 seconds so that the radius of influence got longer by 71% from 392 cm to 671 cm. The remediation system using the micro bubble ozone oxidizer and the pneumatic fracturing equipment for field application was made and demonstrated its remediation efficiency at petroleum contaminated site. The system showed enhanced remediation capacity than the traditional chemical oxidation technology using hydrogen peroxide with reduced remediation time by about 33%.