• Title/Summary/Keyword: Oxygen sensor

Search Result 308, Processing Time 0.033 seconds

Study on Characterization of Galvanic Oxygen Sensor (갈바니식 산소센서의 특성에 관한 연구)

  • Cho, Dong-Hoe;Park, Myon-Yong;Lee, Byoung-Cho;Chung, Koo-Chun;Park, Jongman;Lee, Kyeong-Jae;Chung, Sung-Sook;Park, Sun-Young;Lee, Kwang-Woo
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.371-378
    • /
    • 1994
  • The detection range of this galvanic oxygen sensor for oxygen concentration was 0.0% to 20.0%. By using gold or silver as cathode, reproducible response time and sensitivity to change of oxygen concentration were observed. The anode was Pb-Sn-Ca alloy. Oxygen selective permeable membrane was hydrophobic and porous Teflon film. The effect of the membranes varying in thickness have been studied on the temperature($10{\sim}50^{\circ}C$) and relative humidity(R. H 0~99%). Lead acetate buffer solution as the electrolyte has shown a high output voltage and longer life.

  • PDF

Synthesis of Nanostructured Ceria Powders for an Oxygen-sensor by Thermochemical Process (열화학적 방법에 의한 산소센서용 세리아 나노분말 합성)

  • Lee Dong-Won;Choi Joon-Hwan;Lim Tae-Soo;Kim Yong-Jin
    • Journal of Powder Materials
    • /
    • v.13 no.3 s.56
    • /
    • pp.192-198
    • /
    • 2006
  • The nanostructured cerium oxide powders were synthesized by spray thermal decomposition process for the use as the raw materials of resistive oxygen sensor. The synthesis routes consisted of 1) spray drying of water based organic solution made from cerium nitrate hydrate ($Ce(NO_3){_3}6H_2O$) and 2) heat treatment of spray dried precursor powders at $400^{\circ}C$ in air atmosphere to remove the volatile components and identically to oxidize the cerium component. The produced powders have shown the loose structure agglomerated with extremely fine cerium oxide particles with about 15 nm and very high specific surface area ($110m^2/g$). The oxygen sensitivity, n ($Log{\propto}Log (P_{O2}/P^o)^{-n}$ and the response time, $t_{90}$ measured at $600^{\circ}C$ in the sample sintered at $1000^{\circ}C$, were about 0.25 and 3 seconds, respectively, which had much higher performances than those known in micron or $100{\sim}200nm$ sized sensors.

Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp (HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구)

  • Dong Hyuk Jeong;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

Investigation of the Flow Dependence of a FET-Type Dissolved Oxygen Sensor and Its Reducing Method (FET형 용존 산소 센서의 유속에 의한 영향 조사와 감쇄 기법)

  • Jeong, H.;Kim, Y.J.;Lee, Y.C.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.180-186
    • /
    • 2001
  • Recently, FET type dissolved oxygen sensor was proposed to overcome the disadvantages of the amperometric Clark-type sensor. The inherent problem of the proposed sensor, however, is the flow dependence of the sensor performances since the proposed sensor detects the pH change in close proximity to the working electrode. In this study, we decided the direction which minimize the flow effect in FIA(flow injection analysis) system. And a hydrodynamic buffer layer which can reduce the flow dependence were proposed. The suggested buffer-layers were formed onto sensing area and working electrode with mixed polymer matrix of TEOS(tetraethylorthosilicate) and DEDMS(diethoxydimethylsilane).

  • PDF

Preparation of Ru-C Nano-composite Film by MOCVD and Electrode Properties for Oxygen Gas Sensor

  • Kimura, Teiichi;Goto, Takashi
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.358-359
    • /
    • 2006
  • Ru-C nano-composite films were prepared by MOCVD, and their microstructures and their electrode properties for oxygen gas sensors were investigated. Deposited films contained Ru particles of 5-20 nm in diameter dispersed in amorphous C matrix. The AC conductivities associating to the interface charge transfer between Ru-C composite electrode and YSZ electrolyte were 100-1000 times higher than that of conventional paste-Pt electrodes. The emf values of the oxygen gas concentration cell constructed from the nano-composite electrodes and YSZ electrolyte showed the Nernstian theoretical values at low temperatures around 500 K. The response time of the concentration cell was 900 s at 500 K.

  • PDF

High Oxygen Sensitivity of Nanocrystalline Ceria Prepared by a Thermochemical Process

  • Lee, Dong-Won;Yu, Ji-Hoon;Lim, Tae-Soo;Jang, Tae-Suk
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.416-417
    • /
    • 2006
  • Nanostructured ceria powder was synthesized by a thermochemical process and investigated its applicability for an oxygen gas sensor. An amorphous precursor powders prepared by spray drying a cerium-nitrate solution were transformed successfully into nanostructured ceria by heat-treatment in air atmosphere. The powders were a loose agglomerated structure with extremely fine $CeO_2$ particles about 15 nm in size, resulting in a very high specific surface area $(110\;m^2/g)$. The oxygen sensitivity and the response time $t_{90}$ measured at sintered sample at $1000^{\circ}C$ was about -0.25 and very short, i.e., $3{\sim}5$ seconds, respectively.

  • PDF

YSZ(yttria-stablilized ziroconia) 박막을 이용한 센서셀의 산소감응

  • 배정운;박준용;황순원;김기동;조영아;전진석;최동수;염근영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.128-128
    • /
    • 1999
  • 산소이온 전도체로 잘 알려진 Yttira-Stabilizd Ziroconia(TSZ)는 연료전지, oxygen pumps, chemical gas sensor 등 다양한 electrochemical divices에 이용되는 고체 전해질의 하나이다. 특히 YSZ는 oxygen 및 oxygen과 평형상태에 있는 gas들을 검출하는 sensor의 electrolyte로서 가장 많이 쓰이고 있다. 현재 상용화되어 있는 YSZ Sensor는 전통적인 bulk 형태의 ceramic으로 제작된 것으로 충분한 ionic conductivity를 얻기 위해서는 $600^{\circ}C$이상의 operating temperature를 필요로 하나 YSZ를 박막으로 제조시 낮은 operating temperature를 뿐만 아니라 sensor의 소형화, 낮은 ohmic loss 및 다양한 응용이 가능한 장점을 가질 수 있다. 본 실험에서는 산소 이온 전도체로서 8mol%-YSZ 고체전해질을 RF-magnetron bias sputtering 법을 이용하여 증착하였다. 제조된 YSZ 박막을 이용한 산소감응 센서셀 구조는 SiO2/Ni-NiO/Pt/YSZ/Pt-기판이다. 센서셀의 정상상태에서의 기전력(electromotive force ; EMF)을 산소분압(Po:1.013$\times$103Ta ~1.013$\times$105Pa)과 측정온도(30$0^{\circ}C$~$700^{\circ}C$)를 변화시키며 측정하였다. 이론적인 기전력과 측정값 사이의 편차는 Po:1.565$\times$104Pa 이하의 산소분압에서는 컸지만 이 이상의 분압에서는 이론치에 근접한 값을 가졌다. 증착한 YSZ와 Ni-NiO 박막의 구조는 X-ray diffractometer(XRD)를 이용하여 결정구조를 알아 보았고, TSZ 박막의 표면 morphology 관찰은 Scanning electron microscopy(SEM) 이용하였다. 박막의 조성분석은 X-ray energy dispersive analysis(EDX)을 사용하였다.

  • PDF

A Study of Aging of Oxygen Sensor (1) (산소센서의 열화에 관한 연구(1))

  • 손건석;윤승원;이귀영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.85-91
    • /
    • 2000
  • Oxygen sensors taken from the aftertreatment systems of 4 vehicles which had been aged in domestic filed were examined for aging pattern using a idle engine bench. The sensors were then cut into each layers along their components and characterized for poisoning, surface area and morphology. This study shows that amplitude and mean value of aged sensors are seriously affected by high temperature and oil components of exhaust gas.

  • PDF