• Title/Summary/Keyword: Oxygen indicator

Search Result 118, Processing Time 0.025 seconds

Bacteriological and Physiochemical Quality of Seawater and Surface Sediments in Sacheon Bay (사천만의 해수 및 표층 퇴적물의 세균학적 및 이화학적 특성)

  • Park, Jun-Yong;Kim, Yeong-In;Bae, Ki-Sung;Oh, Kwang-Soo;Choi, Jong-Duck
    • Journal of agriculture & life science
    • /
    • v.44 no.2
    • /
    • pp.7-15
    • /
    • 2010
  • This study was conducted to investigate the bacteriological and physiological quality of seawater and surface sediments in Sacheon Bay of Korea from January to September in 2009. During the study period, the means of temperature was range from 5.3 to $24.9^{\circ}C$ (mean $17.7{\pm}0.4^{\circ}C$), transparency range from 1.4 to 2.5 m (mean $1.8{\pm}0.5m$), suspended solid ranged from 16.2 to 35.8 mg/L (mean $24.2{\pm}2.2mg/L$), chemical oxygen demand ranged from 1.42 to $3.29mgO_2/L$ (mean $2.06{\pm}0.55mgO_2/L$), dissolved oxygen ranged from 6.7 to 9.5mg/L (mean $7.9{\pm}0.6mg/L$), respectively. Seafood, if eaten raw, carries the risk of food poisoning. Seafood poisoning is often cause by pathogenic microorganism originating from fecal contamination, such as Salmonella sp., Shigella sp. and norovirus. Fecal coliforms are an important indicator of fecal contamination. Therefor, data on fecal coliform are very important for evaluating the safety of fisheries in coastal areas. So, we investigated the sanitary indicate bacteria. In this study, 56 sea water samples were collected from the Sacheon Bay, and total and fecal coliforms were compared and analyzed. The coliform group and fecal coliform MPN's of sea water in Sacehon Bay were ranged from <1.8~7,900 MPN/100mL (GM 214.7 MPN/100mL) and <1.8~330 MPN/100mL (GM 9.7 MPN/ 100mL), respectively. Total coliforms were detected in 75.0% of the samples and 76.2% of the total coliforms were fecal coliforms. During the study period, the means of water content, ignition loss, COD, and acid volatile sulfates in sediments in Sacheon Bay were $53.28{\pm}2.58%$, $9.38{\pm}0.42%$, $14.23{\pm}3.36mgO_2/g$, $0.09{\pm}0.07mgS/g$, respectively.

Relationship between Stratum Corneum Carbonylated Protein (SCCP) and Skin Biophysical Parameters (Stratum Corneum Carbonylated Protein (SCCP)의 피부 생물학적 파라미터와의 관계)

  • Lee, Yongjik;Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.2
    • /
    • pp.131-138
    • /
    • 2019
  • Carbonylated proteins (CPs) are synthesized by the chemical reaction of basic amino acid residues in proteins with aldehyde compounds yielded by lipid peroxidation. CPs are excited by a range of light from UVA to blue light, and resulted in the generation of superoxide anion radicals ($^{\cdot}O_2{^-}$) by photosensitizing reaction. Then, they CPs induce new protein carbonylation in stratum corneum through ROS generation. Furthermore, the superoxide anion radicals produce CPs in the stratum corneum (SC) through lipid peroxidation and finally affects skin conditions including color and moisture functions. The purpose of this study was to investigate the relationship between the production of stratum corneum carbonylated protein (SCCP) and the skin elasticity. 46 healthy female Koream at the ages of 30 ~ 50 years old were participated in this study for 8 weeks. The skin test was experiment conducted into two groups; placebo group (N = 23) used cream that did not contain active ingredients, and the other group (N = 23) used cream containing the elasticity improving ingredients. Test areas were the crow 's feet and the cheek. Various non-invasive methods were carried out to measure biophysical parameters on human skin indicating that dermis density and skin wrinkle were measured by using DUB scanner and Primos premium, respectively. Skin elasticity were measured using dermal torque meter (DTM310) and balistometer (BLS780). SCCP was assessed in a simple and non-invasive method using skin surface biopsy on the cheek of the subject. The amount of SCCP was determined using image analysis. All measurements were taken at 0, 4 and 8 8week. Results revealed that the amount of CP in SC was reduced when the skin wrinkle and skin elasticity related parameters were improved. This indicates that the correlation between the elasticity improvement and the amount of CP can be used as a anti-aging indicator and applicable to the skin clinical test for the measurement of skin aging in the future.

Rearing Density of a Flounder, Paralichthys olivaceus Juveniles in a Closed Recirculating Sea Water System - Possibility of High-density Rearing - (폐쇄순환여과시스템에서의 넙치, Paralichthys olivaceus 치어의 사육밀도 - 고밀도사육의 가능성 -)

  • CHANG Young Jin;YOO Sung Kyoo
    • Journal of Aquaculture
    • /
    • v.1 no.1
    • /
    • pp.13-24
    • /
    • 1988
  • In order to investigate a reasonable rearing density and the possibility of high-density rearing, flounder, Paralichthys olivaceus, juveniles of 2.53$\pm$0.24 cm in total length and 1.12$\pm$0.12 cm in body height were used in this study. The initial rearing density of them was 10 (D10), 20 (D20), 30 (D30) and 40 (D40) individuals per 137.75 $cm^2$ of bottom area, respectively. Ranges of water temperature and specific gravity during the rearing period of 65 days were $21.0\~27.0^{\circ}C$ and 1.024$\~$1.026, respectively, showing relatively higher values than that of natural sea water. Dissolved oxygen during the rearing period was 5.4$\~$7.5 ml/$\iota$ and inorganic nitrate was 0.07$\~$0.48 ppm in $NH_4^+-N$, 0.006$\~$0.33 ppm in $NO_2^{-}-N$ and 3.89$\~$34.06 ppm in $NO_3^{-}-N$. Growth in total length and body height of the juveniles in four rearing density at the end of the experiment was 8.17$\pm$0.80 em and 4.16$\pm$0.39 em, the highest in D20 and 7.72$\pm$0.40 cm and 3.94$\pm$0.21 cm, the lowest in D10. Significant differences, however, were not recognized between the slope values of growth regressions in four rearing density. Slope values of the relative growth between total length and body height of the juveniles in four rearing density were 0.5346, the highest in D10 and 0.5165, the lowest in D30, but there were no significant differences in those values. Survival rate of juveniles at the end of the experiment was $90\%$ in D10, D20 and D30, but that of D40 was $75\%$. The relationship between total length X body height (X) and body surface area of ocular side (Y) to calculate the rate of Y to bottom area in rearing tank (covering rate) as an indicator of rearing density was expressed by a linear regression, Y=0.5994X+0.1840. Covering rate in four rearing density at the end of the experiment was ranged 1.2$\~$4.1 times. Judging from the covering rate above 4 times, it seems to be possible rearing the flounder juveniles in high-density.

  • PDF

Comparative Assessment of Specific Genes of Bacteria and Enzyme over Water Quality Parameters by Quantitative PCR in Uncontrolled Landfill (정량 PCR을 이용한 비위생 매립지의 특정 세균 및 효소 유전자와 수질인자와의 상관관계 평가)

  • Han, Ji-Sun;Sung, Eun-Hae;Park, Hun-Ju;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.895-903
    • /
    • 2007
  • As for the increasing demanding on the development of direct-ecological landfill monitoring methods, it is needed for critically defining the condition of landfills and their influence on the environment, quantifying the amount of enzymes and bacteria mainly concerned with biochemical reaction in the landfills. This study was thus conducted to understand the fates of contaminants in association with groundwater quality parameters. For the study, groundwater was seasonally sampled from four closed unsanitary landfills(i.e. Cheonan(C), Wonju(W), Nonsan(N), Pyeongtaek(P) sites) in which microbial diversity was simultaneously obtained by 16S rDNA methods. Subsequently, a number of primer sets were prepared for quantifying the specific gene of representative bacteria and the gene of encoding enzymes dominantly found in the landfills. The relationship between water quality parameters and gene quantification were compared based on correlation factors. Correlation between DSR(Sulfate reduction bacteria) gene and BOD(Biochemical Oxygen Demand) was greater than 0.8 while NSR(Nitrification bacteria-Nitrospira sp.) gene and nitrate were related more than 0.9. A stabilization indicator(BOD/COD) and MTOT(Methane Oxidation bacteria), MCR(Methyl coenzyme M reductase), Dde(Dechloromonas denitrificans) genes were correlated over 0.8, but ferric iron and Fli(Ferribacterium limineticm) gene were at the lowest of 0.7. For MTOT, it was at the highest related at 100% over BOD/COD. In addition, anaerobic genes(i.e., nirS-Nitrite reductase, MCR. Dde, DSR) and DO were also related more than 0.8, which showing anaerobic reactions generally dependant upon DO. As demonstrated in the study, molecular biological investigation and water quality parameters are highly co-linked, so that quantitative real-time PCR could be cooperatively used for assessing landfill stabilization in association with the conventional monitoring parameters.

Perspectives on the Landscape Ecological Function of Dangsan Forests and Rural Community Forests as a Stream Landscape (하천경관으로서 당산숲.마을숲의 경관생태학적 기능 고찰)

  • Choi, Jai-Ung;Kim, Dong-Yeob
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.31-55
    • /
    • 2005
  • Dangsan forests and Rural Community Forests(RCF) have been historical assets for the rural communities of more than 40,000 in Korea and they have provided an identity through the cultural heritage. The Dangsan forests and the RCF are parts of a unique cultural landscape in the rural areas as components of stream landscape. In many cases, the Dangsan forests and the RCF are located close to stream corridors. The objective of this study was to understand the function of the Dangsan forests and the RCF on stream water quality and to evaluate its ecological landscape values. Through the consideration of international concensus and domestic government policy for close-to-nature stream, we could find out that Dangsan forests and RCF's have close relationship with the close-to-nature streams. The water quality of the streams close to the Dangsan forests and the RCF are maintained with local culture. It is also compared to the streams located where Dangsan forests and the RCF are absent. Eight study sites were selected. Water samples were collected at three different locations at each study site. Water samples were analyzed for temperature, pH, total P, total N, dissolved oxygen, EC, BOD, COD and SS. Aquatic invertebrates were observed as water quality indicator species. The results showed that the number of aquatic invertebrate species, GPI, DO, EC, BOD, and SS were significantly improved in stream water due to the presence of the Dangsan forests and the RCF. The role of Dangsan forests and the RCF was evident in the conservation of stream landscape and rural culture as well as in maintaining stream water quality. The management schemes of the streams with Dangsan forests and the RCF's are also suggested.

  • PDF

Benthic Environments and Macrobenthic Polychaete Community Structure in the winter of 2005-2006 in Gamak Bay, Korea (가막만의 2005년과 2006년 동계 저서환경 및 대형저서다모류군집구조)

  • Yoon, Sang-Pil;Kim, Youn-Jung;Jung, Rae-Hong;Moon, Chang-Ho;Hong, Sok-Jin;Lee, Won-Chan;Park, Jong-Soo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.1
    • /
    • pp.67-82
    • /
    • 2008
  • This study was performed to investigate changes in benthic environment and macrobenthic polychaete communities in Gamak Bay where various environmental quality improvement projects have been implemented in recent years. Field surveys were carried out in February, 2005 and February, 2006 and twenty stations were selected to explore whether or not there were between-year differences in biotic and abiotic variables. Of 10 environmental variables measured, only three variables including dissolved oxygen (DO), total ignition loss (IL), acid volatile sulfide (AVS) showed significant between-year differences. Specifically, IL and AVS were, on average, 1.5 and 3 times lower in 2006 compared to those in 2005, respectively, which was more pronounced in the northern part of the bay. A total of 95 polychaete species was sampled from the two sampling occasions. Between-year differences in the number of species, abundance, and diversity were varied from place to place. In the northern part of the bay, fewer species were found in 2006 rather than in 2005, but diversity increased in 2006 due to the reduction in dominance of a few species. On the contrary, in the central part of the bay, the number of species, abundance and diversity prominently increased in 2006. In the southern part of the bay, all the biological indices maintained similarly during the two years. Dominant species in 2005 were such opportunistic or organic pollution indicator species as Lumbrineris longifolia, Capitella capitata, Mediomastus californiensis, Pseudopolydora paucibranchiata, etc. and most of them were mainly distributed in the northern part of the bay and in the proximity of it. In 2006, however, Euchone alicaudata, L. longifolia, Paraprionospio pinnata, Flabelligeridae sp., etc. were dominant and distributed mainly in the central part of the bay. Multivariate analyses showed that the whole polychaete community could be divided into 5 groups reflecting the geographical positions of the sampling stations and temporal variation particularly in the northern part of the bay. According to the results of BIO-ENV procedure, TOC (${\rho}=0.52$) and AVS (${\rho}=0.49$) as a single variable best explained the polychaete community structure. The best combination was made by such variables as TOC, AVS, sorting coefficient, and water temperature (${\rho}=0.60$). In conclusion, between-year differences in biotic and abiotic variables imply that recent efforts for the environmental improvement produced positive influences on the benthic environment of Gamak Bay, particularly the northern part of the bay.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.