• 제목/요약/키워드: Oxygen demand

검색결과 925건 처리시간 0.037초

Estimation of BOD in wastewater treatment plant by using different ANN algorithms

  • BAKI, Osman Tugrul;ARAS, Egemen
    • Membrane and Water Treatment
    • /
    • 제9권6호
    • /
    • pp.455-462
    • /
    • 2018
  • The measurement and monitoring of the biochemical oxygen demand (BOD) play an important role in the planning and operation of wastewater treatment plants. The most basic method for determining biochemical oxygen demand is direct measurement. However, this method is both expensive and takes a long time. A five-day period is required to determine the biochemical oxygen demand. This study has been carried out in a wastewater treatment plant in Turkey (Hurma WWTP) in order to estimate the biochemical oxygen demand a shorter time and with a lower cost. Estimation was performed using artificial neural network (ANN) method. There are three different methods in the training of artificial neural networks, respectively, multi-layered (ML-ANN), teaching learning based algorithm (TLBO-ANN) and artificial bee colony algorithm (ABC-ANN). The input flow (Q), wastewater temperature (t), pH, chemical oxygen demand (COD), suspended sediment (SS), total phosphorus (tP), total nitrogen (tN), and electrical conductivity of wastewater (EC) are used as the input parameters to estimate the BOD. The root mean squared error (RMSE) and the mean absolute error (MAE) values were used in evaluating performance criteria for each model. As a result of the general evaluation, the ML-ANN method provided the best estimation results both training and test series with 0.8924 and 0.8442 determination coefficient, respectively.

해양퇴적물에서 중금속 용출 차단 및 퇴적물 산소 요구량 감소를 위한 석회석, 제올라이트 및 폐콘크리트의 피복 소재로서 적용 (Application of Limestone, Zeolite, and Crushed Concrete as Capping Material for Interrupting Heavy Metal Release from Marine Sediments and Reducing Sediment Oxygen Demand)

  • 강구;박성직
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.31-38
    • /
    • 2015
  • This study aims to assess the effectiveness of limestone, zeolite, and crushed concrete as capping material to block the release of heavy metals (As, Cu, Cr, Ni, and Pb) and reduce the sediment oxygen demand. The efficiency of limestone, zeolite, and crushed concrete was evaluated in a reactor in which a 1-cm thick layer of capping materials was placed on the sediments collected from Inchon north harbor. Dissolved oxygen concentration and heavy metal concentration in seawater above the uncapped sediments and capping material were monitored for 17 days. The sediment oxygen demand was in the following increasing order: crushed concrete ($288.37mg/m^2{\cdot}d$) < zeolite ($428.96mg/m^2{\cdot}d$) < limestone ($904.53mg/m^2{\cdot}d$) < uncapped ($981.34mg/m^2{\cdot}d$). The capping materials could reduce the sediment oxygen demand by blocking the release of biochemical matters consuming dissolved oxygen in seawater. It was also shown that zeolite and crushed concrete could effectively block the release of Cu, Ni, and Pb but those were not effective for the interruption of As and Cr release from marine contaminated sediments.

팔당호 수변부 퇴적물이 수층의 산소소모에 미치는 영향 (Effect of Bottom Sediments on Oxygen Demand of Overlying Water in Onshore of Lake)

  • 강양미;송홍규
    • 생태와환경
    • /
    • 제33권1호통권89호
    • /
    • pp.23-30
    • /
    • 2000
  • 초록(한글) 입력자 : 퇴적층 산소요구는 수중의 퇴적층에서 생물학적 호기성 대사와 화학적 산화에 소모되는 용존산소량으로 1999년 4월부터 11월 사이에 팔당호 현장에서의 SOD는 조사시점에 따라 $4{\sim}5$ 시간동안 $1.57{\sim}12.55$ mg $O_{2}m^{-2}h^{-1}$로 나타났다. 또한 SOD는 퇴적유기물의 양과 퇴적층 내로의 산소 확산의 영향이 컸다. 초기 30분 동안에 물과 퇴적층의 산소요구를 비교하면 SOD가 수층 전체 산소소모의 $63.8{\sim}94$%를 차지하였다. 실험실 내의 SOD 측정에서 화학적 퇴적층 산소요구는 크게 일어나지 않았으며 퇴적층의 탄소성 산소요구는 전체 SOD보다 적게 나타났다. 이 결과로부터 팔당호의 SOD는 주로 생물학적 산소요구에 의한 것이며 질화작용에 의한 산소요구가 SOD에 큰 비중을 차지함을 알 수 있었다. 퇴적층의 두께가 SOD에 미치는 영향은 퇴적물의 특성에 크게 좌우되며 유속을 2배로 빠르게 한 경우에는 SOD가 $1.4{\sim}1.9$배 증가하였다. 본 연구를 통해 SOD가 수층의 용존산소를 감소시키는 주요한 요인임을 알 수 있었으며 상수원으로 이용되는 호수에서 이를 감안한 수질관리가 적용되어야 할 것으로 판단된다.

  • PDF

항공기용 산소 시스템 요건 분석 (Requirements Analysis for Aircraft Oxygen Systems)

  • 유승우;박근영;정봉구
    • 항공우주시스템공학회지
    • /
    • 제3권3호
    • /
    • pp.39-44
    • /
    • 2009
  • Humans rely on the availability of a supply of gaseous oxygen for survival. If the minimal requirements for oxygen are not met, both mental and physical abilities and performance are degraded rapidly. So oxygen systems are required for the aircraft operating at high altitude to prevent physical and psychological problems, or loss of consciousness in an aircraft pilot, flight crew, or passengers. If oxygen system and equipments are to be included in the type design of an airplane, applicant should consider applicable airworthiness requirements and operating rules. In this paper we analyze the various oxygen system requirements for the type of aircraft, oxygen system, and operating conditions.

  • PDF

하계 경기만의 수질오염과 생산력에 관한 연구 1

  • 이민재;홍순우;하영칠
    • 미생물학회지
    • /
    • 제10권3호
    • /
    • pp.97-104
    • /
    • 1972
  • The extent of water pollution was investigated at 4 stations in Kyonggi Bay during the summer seasons in 1970 and 1971. The concentrations of dissolved oxygen, total hardness, ammonia, nitrate, nitrite, phosphate, chemical oxygen demand, salinity, biochemical oxygen demand, coliform bacteria and facel coli were examined together with the measurement of pH and transparency. The relationship between the extent of pollution and the distance from the Inchon Bay also was examined. The concentrations of biochemical oxygen demand, chemical oxygen demand, ammonia, nitrate, nitrite, phosphate, coliform bacteria nad fecal coli were all highest at station 1, and lowest at station 4. Values were somewhat higher at low tide level in general. On the contrary, dissolved oxygen concentration was highest at station 4 and lowest at station 1. The highest and lowest values of biochemical oxygen demand were 10.88 ppm at station 1 and 0.27 ppm at station 4. The chemical oxygen demand concentrations at station 1 and 4 were 1.90 ppm and 0.63 ppm. Ammonia concnetration at station 1 was 0.43 pp, and was nearly 5 times as much as that at station 4. The values were $2.45{\times}10^{-4}$ ppm at station 1, and $6{\times}10^{-4}$ ppm at station 4. Nitrite concnetration at station 1 was $3{\times}10^{-4}$ppm and was the highest, while the lowest was $9.45{\times}10^{-5}$ ppm at station 4. Phosphate value at station 1 too was the highest and was about 4 times as much as that at station 4. Coliform bacteria were most abundant at station 1, and were counted to be 1.$1.7{\times}10^{-5}$cells/ml. At station 4, the number greatly reduced to 8 * 10$^{2}$ cells/ml. The number of fecal coli at station 1 was $2{\times}10^{-4}$ cells/ml. But at station 4, no fecal coli was detected at high tide level. At low tide level, 3 cells/ml were counted at station 4. In all of these, the highest data were obtained at low tide level, while most of the lowest value, at high tide level. Generally, values at statio 1 were 3-5 times as much as those at station 4. Concentration of dissolved oxygen at station 1 was 0.366 mg-atoms/1 and was the lowest. The highest value was 0.420 mg-atoms/1 and was recorded at station 4. The highest at station 4, which certainly were believed to be the result of the dilution by the fresh water of the Han river flowing into the Inchon Bay. As we can see from the data above, the extent of pollution was highest at station 1, the nearest from Inchon harbor, and lowest at station 4, where is the farthest, Station 1 and 2 were proved to be much polluted, but station 3 and 4, not.

  • PDF

3 Types of Set Point Controllers for Biological Wastewater Treatment Process

  • Kim, D.;Lee, I.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.97.1-97
    • /
    • 2001
  • One of the main problems to constitute control method on biologically oriented wastewater purification processes, e.g. activated sludge process, sequential batch reactor, rotating bio-disk contactor, etc. is that it is hard to control the target component directly. For instance, while biochemical oxygen demand, suspended solids, and chemical oxygen demand are the key components to check the process performance, one may not control them directly since they are the results of microbial activities related to numerous physiochemical factors. Therefore controllers for bioprocess should be designed to make favorable condition for microorganisms´ living, e.g. dissolved oxygen level favorable, mixed liquor suspended solids concentration suitable ...

  • PDF

하수처리장 유출수의 NOD를 고려한 BOD 측정에 관한 연구 (Effect of NOD on BOD Test for the Effluents of Biological Treatment Plant)

  • 장세주;이성호;박해식;박청길
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.188-192
    • /
    • 2007
  • The biochemical oxygen demand (BOD) test is widely used to determine the pollution strength of water, to evaluate the performance of wastewater treatment plants and to judge compliance with discharge permits. However, nitrification is a cause of significant errors in measuring BOD, particularly when a large population of nitrifying organisms is existing in water such as effluents from biological treatment plants. In order to investigate the amount of nitrogenous oxygen demand (NOD), BOD with and without inhibitor was measured as samples in the biological treatment plants. About 81% of effluent BOD from the biological treatment plant used in this experiment was comprised of NOD. In the case of influents, the NOD accounted for about 9% of BOD. The inhibited 5-day BOD (Carbonaceous BOD) test must be considered in evaluating the performance of wastewater treatment plant and judging compliance with discharge permit limitations.

수중(水中) 수은(水銀) 및 鉛(연)의 농도(濃度)가 BOD값에 미치는 영향(影響)에 관(關)하여 (Effect of Mercury and Lead on the Biochemical Oxygen Demand (BOD))

  • 문재동
    • Journal of Preventive Medicine and Public Health
    • /
    • 제17권1호
    • /
    • pp.217-221
    • /
    • 1984
  • In order to estimate interfering effects of mercury and lead on biochemical oxygen demand (BOD), BOD in 18 effluent samples were measured under three different concentrations of mercury and lead. The results obtained were as follows: 1. Biochemical oxygen demand(BOD) was decreased under the presence of mercury and lead, with parallel correlation of mercury concentration. 2. High correlations were noted between original BOD concentration and decreasing amount of BOD when concentrations of mercury or lead were increased. 3. When the lead concentration was high, the close correlation was observed between total organic carbon(TOC) and decreasing amount of BOD. 4. There was a negative correlation between TOC/BOD ratio and decreasing amount of BOD when the mercury concentrations were high.

  • PDF

Electrochemical Determination of Chemical Oxygen Demand Based on Boron-Doped Diamond Electrode

  • Dian S. Latifah;Subin Jeon;Ilwhan Oh
    • Journal of Electrochemical Science and Technology
    • /
    • 제14권3호
    • /
    • pp.215-221
    • /
    • 2023
  • A rapid and environment-friendly electrochemical sensor to determine the chemical oxygen demand (COD) has been developed. The boron-doped diamond (BDD) thin-film electrode is employed as the anode, which fully oxidizes organic pollutants and provides a current response in proportion to the COD values of the sample solution. The BDD-based amperometric COD sensor is optimized in terms of the applied potential and the solution pH. At the optimized conditions, the COD sensor exhibits a linear range of 0 to 80 mg/L and the detection limit of 1.1 mg/L. Using a set of model organic compounds, the electrochemical COD sensor is compared with the conventional dichromate COD method. The result shows an excellent correlation between the two methods.