• Title/Summary/Keyword: Oxygen capacity

Search Result 675, Processing Time 0.025 seconds

Selection of Oxygen Carrier Candidates for Chemical Looping Combustion by Measurement of Oxygen Transfer Capacity and Attrition Loss (산소전달량 및 마모손실 측정에 의한 매체순환연소용 산소전달입자 후보 선정)

  • KIM, HANA;PARK, JAEHYEON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.404-411
    • /
    • 2016
  • To select appropriate oxygen carrier candidates for chemical looping combustion, reduction characteristics of seven oxygen carriers were measured and discussed using three different reduction gases, such as $H_2$, CO, and $CH_4$. Moreover, attrition losses of those oxygen carriers also measured and compared. Among seven oxygen carrier particles, OCN703-1100 and NiO/bentonite particles showed higher oxygen transfer capacity than other particles, but these particles showed more attrition loss than other particles. C14 and C28 particles which used as cheap oxygen carriers in European country showed lower oxygen transfer capacity and less attrition loss. Based on the experimental results, we could select OCN717-R1SU, NC001, and N002 particles as candidates for future works because these oxygen carriers showed enough oxygen transfer capacity and good attrition resistance.

The Effect of Coenzyme Q10 Supplementation on Oxidative Stress Index and Antioxidant Capacity in the Elderly (Coenzyme Q10 섭취가 노인들의 혈중 산화적 스트레스 지표 및 항산화 능력에 미치는 영향)

  • Kim, Jung-Kyu;Roh, Seong-Kyu
    • Korean Journal of Exercise Nutrition
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2009
  • The purpose of this study was to investigate the effects of oral supplementation of coenzyme Q10 (CoQ10) for 4 weeks on the plasma free oxygen radical and total antioxidant capacity at resting and after one bout exercise in healthy old men. Thirty volunteers with an average (+/-SD) age of 62.59+/-5.3 years participated in this study and were divided with three groups; CoQ10 (200 mg daily) group, vitamin C & E (800mg, 400 IU daily) group, and placebo group. A cycle exercise (60% HRR) test was performed at the end of study. Blood samples were taken for the analyses at rest and pre-, post-, 30min after cycle exercise, before and after the 4 weeks of supplementation. After supplementation, there were no significant differences in the plasma free oxygen radical levels and total antioxidant capacity at resting. Plasma free oxygen radical level and total antioxidant capacity in three groups were significantly elevated after exercise, however, it did not vary significantly between groups. CoQ10 supplementation showed significant difference in total antioxidant capacity during recovery phase compared with placebo group. Our results demonstrated that supplementation of CoQ10 in healthy old men improve blood total antioxidant capacity after one bout exercise, despite no alteration of plasma free oxygen radical levels.

The Analysis of Old Person's Total Antioxidant Capacity and Free Oxygen Radical According to Exercise Frequency of Combination Exercise (빈도에 따른 복합운동프로그램이 노인들의 체내 총항산능 및 활성산소 유리기에 미치는 영향)

  • Jung, Jae-Min;Kim, Eun-Jung;Yoon, Young-Cho;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.3
    • /
    • pp.141-148
    • /
    • 2009
  • Purpose:The purpose of this study was analyze the effect combination exercise program on plasma total antioxidant capacity and free oxygen radical according to exercise frequency of elderly. Age range of subject is 65~70 years. Methods:Subjects divided into three groups: control group(0-time), week-3 times group(3-times), week-5 times group(5-times). Each group were performed combination exercise during 8 weeks. Results:The results of each group by ANOVA free oxygen radical have a change(p<.05). We performed comparison of total antioxidant capacity and free oxygen radical pre-test and post-test on each groups. Total antioxidant capacity was increased in the 3-times and 5-times groups but there have not significant. Total antioxidant capacity is improve better than to 5-times. Free oxygen radical is significant increased in the 0-time (p<.05). But 5-times but 3-times is no significant decrease. Free oxygen radical is improve better than to 3-times. Conclusion:In the old people, exercise frequency week 3 times doing appeared effectively in improvement of the free oxygen radical and 5 times doing appeared effectively in improvement of the total antioxidant capacity. So rightly must apply a exercise frequency well in characteristic of old person each person.

  • PDF

CH4 Combustion Characteristics of Oxygen Carriers in a Bubbling Fluidized Bed (기포유동층에서 산소전달입자들의 메탄 연소특성)

  • RYU, HO-JUNG;PARK, YOUNGCHEOL;LEE, SEUNG-YONG;JO, SUNG-HO;SHUN, DOWON;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.581-588
    • /
    • 2016
  • To compare reduction reactivity of oxygen carrier particles, $CH_4$ combustion characteristics were measured and investigated in a bubbling fluidized bed reactor with increasing $CH_4$ concentration from 10 to 100 %. Among five oxygen carriers (OC-1, OC-2, SDN70, C14, C28), OC-1, OC-2, SDN70 particles were selected as better oxygen carriers from the viewpoints of fuel conversion and $CO_2$ selectivity. However, some oxygen carriers showed lower fuel conversion and $CO_2$ selectivity even though they have high oxygen transfer capacity. Therefore, we could conclude that not only TGA tests to measure the oxygen transfer capacity but also fluidized bed tests to analyze exhaust gas concentration should be performed to select better oxygen carrier without misunderstanding of carriers reactivity.

A Study on Active Oxygen and Antioxidant capacity of Qi Deficiency and Blood Deficiency Animal Model (기허(氣虛), 혈허(血虛) 동물모델에서의 활성산소 및 항산화력 연구)

  • Jeon, Sun-Woo;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.2
    • /
    • pp.74-81
    • /
    • 2009
  • Background and Objective : There are a lot of theories that explained the aging process, and the oxidative stress is one of the important theory that explained the aging process. The aim of this study was to investigate active oxygen and antioxidant capacity of Qi deficiency and Blood deficiency animal models. Material and Methods : Sprague-Dawley rats were divided into three groups: normal group, Qi deficiency group and Blood deficiency group. The Qi deficiency animal model was induced through restriction of food (12g/kg/day) for 20 days. Blood deficiency animal model was induced by bleeding from tail vein(0.4ml/time) 8 times. The normal animal model was kept without any intervention. The oxidative stress was observed by measuring the active oxygen and antioxidant capacity. Results and Conclusion : 1. Active oxygen was significantly increased in the Qi deficiency group and Blood deficiency group. (P=0.061) 2. Antioxidant capacity was increased in the Qi deficiency group and Blood deficiency group. But there is no significant difference. (P=0.113)

  • PDF

Polymer Waste Incineration by Oxygen Enriched Combustion (사업장폐기물의 순산소 소각기술)

  • Han, In-Ho;Choi, Kwang-Ho;Choung, Jin-Woo
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.132-139
    • /
    • 2000
  • Oxygen enriched incineration can increase the incineration capacity for wastes and dramatically reduce air pollutant emissions such as CO and dioxine by the allowing complete combustion of wastes in incinerator. Furthermore, this technology is proven to have many benefits including an energy-saving, cost-effective, and versatile application for diverse wastes compared with the conventional air incineration technology. The reduced pollutant emissions in flue gas and higher incineration efficiency are also available when the oxygen enriched air is used for the high temperature incineration systems. On the basis of the experimental results the oxygen enrichment system is successfully applied to the rotary kiln incinerator for industrial wastes. The oxygen enriched incineration system could be allowed more compact design of incinerator and flue gas treatment system due to both increasing incineration capacity and reducing flue gas volume. Therefore, oxygen enriched incineration technology is becoming highlighted in the waste incinerator which strongly require more stable efficiency and environmentally friendly and safe operationPut Abstract text here.

  • PDF

RF-Sputted Vanadium Oxide Thin Films:Effect of Oxygen Partial Pressure on Structural and Electrochemical Properties

  • Park, Yong Jun;Park, Nam Gyu;Ryu, Gwang Seon;Jang, Sun Ho;Park, Sin Jong;Yun, Seon Mi;Kim, Dong Guk
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.9
    • /
    • pp.1015-1018
    • /
    • 2001
  • Vanadium oxide thin films with thickness of about 2000 $\AA$ have been prepared by radio frequency sputter deposition using a V2O5 target in a mixed argon and oxygen atmosphere with different Ar/O2 ratio ranging from 99/1 to 90/10. X-ray diffraction and X-ray absorption near edge structure spectroscopic studies show that the oxygen content higher than 5% crystallizes a stoichiometric V2O5 phase, while oxygen deficient phase is formed in the lower oxygen content. The oxygen content in the mixed Ar + O2 has a significant influence on electrochemical lithium insertion/deinsertion property. The discharge-charge capacity of vanadium oxide film increases with increasing the reactive oxygen content. The V2O5 film deposited at the Ar/O2 ratio of 90/10 exhibits high discharge capacity of 100 ${\mu}Ah/cm2-{\mu}m$ along with good cycle performance.

An Explanatory Model on Functional Capacity in Patients with Chronic Obstructive Pulmonary Disease (만성 폐쇄성 폐질환 환자의 기능적 용량 설명모형)

  • Bang, So-Youn
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.4
    • /
    • pp.652-663
    • /
    • 2008
  • Purpose: This study was conducted to develop and test an explanatory model on functional capacity in patients with chronic obstructive pulmonary disease using path analysis. Methods: Data were collected from 149 chronic obstructive pulmonary disease patients using 6-minute walk test, measurement of oxygen saturation, pulmonary function test, and self-reported questionnaires from June to October, 2005. The collected data were analyzed using SPSS/WIN 12.0 program and AMOS/WIN 4.0 program. Results: The overall fitness indices of modified model were good($x^2$ = 14.324, p = .281 GFI = .981, RMSEA = .006, AGFI = .944, NFI = .927, NNFI = .999, CFI = .999, PNFI = .613, $x^2$/df = 1.194). Functional capacity was influenced directly by age(${\beta}$ = -.304, p = .000), dyspnea(${\beta}$ = -.278, p = .000), self-efficacy(${\beta}$ = .240, p = .000), social support(${\beta}$ = .175, p = .004), pulmonary function(${\beta}$ = .169, p = .008), and oxygen saturation(${\beta}$ = .099, p = .048). These variables explained 39.3% in functional capacity. Conclusion: The findings of this study suggest that comprehensive nursing interventions should focus on decreasing dyspnea and increasing self-efficacy, social support, and oxygen saturation. In this perspective, pulmonary rehabilitation would be an effective strategy for improving functional capacity in patients with chronic obstructive pulmonary disease.

  • PDF

Studies on the Activity Properties of Pd-only Three-Way Catalyst for the Purification of Automobile Exhaust Emissions (자동차 배기가스 정화용 Pb-only 삼원촉매의 활성특성에 관한 연구)

  • 신병선;김상수;이길우;정명근;배재호;정석진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.667-676
    • /
    • 1999
  • The roles of ceria on three-way catalyst is to improve the noble metal dispersion and thermal stability of support ${\gamma}$-$Al_2O_3$. And, ceria has a oxygen storage capacity(OSC) under fuel rich/lean conditions to improve the operating windows of NOx, THC and CO conversion. However, ceria has weak thermal stability under high temperature due to the crystallite growth. So that, the OSC of ceria is decreased, and then the conversions of NOx, THC and CO is decreased. One way of enhancing the thermal stability and NOx, THC and CO conversion Pd-only catalyst is to improve as well as its thermal stability and oxygen storage capacity of the ceria. Especially, the appropriate mixing ratios of bulk and stabilized ceria are very important for designing principles of Pd-only three-way catalysts. In this paper, we discussed the thermal properties of stabilizedand unstabilized (bulk) ceria, and the oxygen storage capacity (OSC) of catalysts, and found the correlation between activity and the OSC of Pd-only catalysts with various different mixing ratios of bulk and stabilized ceria. Finally, we propose the design principles to improve the thermal stability of washcoated Pd-only catalysts.

  • PDF

Reduction Characteristics of Oxygen Carrier Particles for Chemical-looping Combustor with Different Fuels (매체순환식 가스연소기용 산소공여입자들의 연료별 연소특성)

  • Ryu, Ho-Jung;Kim, Kyung-Su;Park, Yeong-Seong;Park, Moon-Hee
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.1
    • /
    • pp.45-54
    • /
    • 2009
  • Reduction reactivity and carbon deposition characteristics of three oxygen carrier particles(OCN01, OCN02, OCN03) have been investigated by using hydrogen, methane, syngas, and natural gas as fuels. For all particles, the maximum conversion, the oxygen transfer capacity, and the degree of carbon deposition increased as the reactive carbon contents increased. The reduction rate and the oxygen transfer rate increased as the moles of required oxygen per input gas increased. The change of maximum conversion, reduction rate, oxygen transfer capacity, oxygen transfer rate and degree of carbon deposition for different fuels can be explained consistently by using parameters such as the reactive carbon contents and the moles of require oxygen per input gas.