• 제목/요약/키워드: Oxygen Chamber

검색결과 350건 처리시간 0.024초

고압산소 치료기에 대한 고장모드 분석 (Failure Mode Analysis for a Hyperbaric Oxygen Chamber)

  • 전태보;박성빈
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.9-14
    • /
    • 2013
  • Reliability plays a pivotal role in the development of medical instruments. A hyperbaric oxygen chamber, as a medical/health device, is known to help medical therapy for diversity of diseases through provision of high purity oxygen. The use of hyperbaric oxygen chamber is expected to increase in the future and study to examine reliability and safety is needed. We have performed reliability assessment for a newly developed hyperbaric oxygen chamber in this study. We first briefly discussed the system structure and mechanism. We then performed FMEA (Failure Mode and Effect Analysis) for the chamber. We drew major failure modes affecting the system performance and performed in depth analysis for measuring the expected effects.

  • PDF

산소 챔버의 근육 피로회복효과에 대한 연구 (The Study of Effect on Oxygen Chamber for Recovery of Muscular Fatigue)

  • 유수정;남은영;김형준
    • 대한한방부인과학회지
    • /
    • 제29권2호
    • /
    • pp.83-98
    • /
    • 2016
  • Objectives: This Study was designed to investigate the effect of Oxygen chamber to recover muscle fatigue. Methods: Twenty Subjects were divided into Oxygen Chamber Group (n=10) and Rest group (n=10). Subjects visited hospital two times, blood tests were performed 3 times for each visit. 1st blood test was performed in 4 hours hunger state. 2nd blood test was performed within 5 minutes after the 6 minutes bike exercise. 3rd blood test was performed after the 40 minutes Oxygen treatment or 40 minutes rest in bed. Blood test items were Lactate, Glucose, Lactate Dehydrogenase, Creatine Kinase, Free Fatty Acid. 2nd visit was applied 1st visit process, But Oxygen Chamber group was crossed over to Rest Group, Rest Group was crossed over to Oxygen Chamber group. The Blood test result was analyzed with paired T-test using SPSS for Windows version 21. Results: The reduction of Lactate in Oxygen Chamber Group (6.86±2.07 mmol/ℓ) was higher than Rest group (6.57±2.33 mmol/ℓ), but it was not statically significant (p=0.68). The reduction of Glucose in Oxygen Chamber Group (6.85±12.14 mg/dl) was lower than Rest group (7.60±9.83 mg/dl), but it was not statically significant (p=0.83). The reduction of Lactate Dehydrogenase in Oxygen Chamber Group (16.10±14.91 mmol/ℓ) was lower than Rest group (19.75±12.46 mg/dl), but it was not statically significant (p=0.41). The reduction of Creatine Kinase in Oxygen Chamber Group (13.40±5.69 U/ℓ) was lower than Rest group (15.25±8.01 U/ℓ), but it was not statically significant (p=0.41). The reduction of Free Fatty Acid in Oxygen Chamber Group (285.50±174.13 uEq/ℓ) was higher than Rest group (196.15±131.58 uEq/ℓ), but it was not statically significant (p=0.07). Conclusions: This study showed Oxygen chamber therapy could be effective to recover muscle fatigue.

고압 산소 치료기에 대한 예비위험분석 (Preliminary Hazard Analysis for a Hyperbaric Oxygen Chamber)

  • 전태보
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.3-8
    • /
    • 2013
  • Reduction of risk plays a pivotal role in the development of medical instruments. A hyperbaric oxygen chamber, as a medical device, is known to help medical therapy for diversity of diseases through provision of high purity oxygen. The use of hyperbaric oxygen is expected to increase in the future and study to rigorously examine reliability and safety is needed. We have performed risk assessment for a newly developed hyperbaric oxygen chamber in this study. We first briefly discussed the system structure and concept of risk assessment for the study. Based on the hazards identified, we performed preliminary hazard analysis for the chamber.

  • PDF

고압산소챔버 중재가 알코올에 의한 산화적 스트레스 및 숙취 해소에 미치는 영향 (Effects of Hyperbaric Oxygen Intervention on Alcohol-Induced Oxidative Stress and Hangover in Hyperbaric Oxygen Chamber)

  • 권혁찬;박순원;조현정;강지현;이현주;태기식
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권5호
    • /
    • pp.175-182
    • /
    • 2018
  • The purpose of this study is to evaluate the reliability and effectiveness of hyperbaric oxygen chamber on alcohol-induced oxidative stress and hangover. In order to evaluate them, 20 healthy adults were tested for blood and hangover stress tests. When an exponential change was examined after 3 interventions (hangover drink, hyperbaric oxygen chamber, and normal chamber as placebo effect) of 1 hour, the heart rate of subjects experiencing a hyperbaric oxygen chamber showed a statistically significant decrease (p < 0.001). The tests of blood alcohol concentration (BAC) as for exquisite hematology analysis, glucose, creatinine, and AST (aspartate aminotransferase) as well as ALT (alanine aminotransferase) used as liver-damage indicator show that the hyperbaric chamber has the effective effect. In the test of lactic acid, CRP (c-reactive protein), cortisol, and creatinine, the hyperbaric chamber shows much more excellent effect than the hangover drink and normal chamber as control groups. Further studies on hyperbaric oxygen chamber intervention including this study could be very helpful for improving lives of both the patients and healthy people.

냉증에 대한 산소챔버의 임상 효능 및 안전성 연구 (Effect and Safety of Oxygen Chamber Therapy on Cold Hypersensitivity: A Randomized, Controlled Trial)

  • 하헌용;윤달환;고호연;한용대;김남식;남은영;김형준
    • 대한한방부인과학회지
    • /
    • 제26권4호
    • /
    • pp.123-139
    • /
    • 2013
  • Purpose: Cold hypersensitivity is regarded to be associated with blood circulation. This study is aims to evaluate the effects and safety of oxygen chamber therapy on cold hypersensitivity by comparing the temperature and Visual Analogue Scale. Methods: 42 outpatients who visited ${\bigcirc}{\bigcirc}$ University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than $0.3^{\circ}C$ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold hypersensitivity. 42 outpatients diagnosed with cold hypersensitivity are divided into two groups, one is the experimental group consisted of 21 patients and other was control group consisted of 21 patients. The experimental group had oxygen chamber therapy 10 times for 4 weeks. Thereafter the effects of oxygen chamber therapy on cold hypersensitivity was analyzed with t-text using SPSS for Windows version 21. Results: After the oxygen chamber therapy, experimental group had considerable improvement on cold hypersensitivity, in consequence of decreasing rate of thermal difference and VAS of cold hypersensitivity. Ear deafness and hand numbness were reported as an adverse effects in experimental group, but there was no serious adverse effects. Conclusions: This clinical trial showed oxygen chamber therapy could be effective and safe to reduce cold hypersensitivity.

도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구 (Study on Co-incineration of Municipal Solid Waste and Organic Sludges)

  • 정종수;진성민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

Oxygen Plasma Characterization Analysis for Plasma Etch Process

  • Park, Jin-Su;Hong, Sang-Jeen
    • 동굴
    • /
    • 제78호
    • /
    • pp.29-31
    • /
    • 2007
  • This paper is devoted to a study of the characterization of the plasma state. For the purpose of monitoring plasma condition, we experiment on reactive ion etching (RIE) process. Without actual etch process, generated oxygen plasma, measurement of plasma emission intensity. Changing plasma process parameters, oxygen flow, RF power and chamber pressure have controlled. Using the optical emission spectroscopy (OES), we conform to the unique oxygen wavelength (777nm), the most powerful intensity region of the designated range. Increase of RF power and chamber pressure, emission intensity is increased. oxygen flow is not affect to emission intensity.

Simulation of Inductively Coupled $Ar/O_2$ Plasma; Effects of Operating Conditions on Plasma Properties and Uniformity of Atomic Oxygen

  • Park, Seung-Kyu;Kim, Jin-Bae;Kim, Heon-Chang
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.59-63
    • /
    • 2009
  • This paper presents two dimensional simulation results of an inductively coupled $Ar/O_2$ plasma reactor. The effects of operating conditions on the plasma properties and the uniformity of atomic oxygen near the wafer were systematically investigated. The plasma density had the linear dependence on the chamber pressure, the flow rate of the feed gas and the power deposited into the plasma. On the other hand, the electron temperature decreased almost linearly with the chamber pressure and the flow rate of the feed gas. The power deposited into the plasma nearly unaffected the electron temperature. The simulation results showed that the uniformity of atomic oxygen near the wafer could be improved by lowering the chamber pressure and/or the flow rate of the feed gas. However, the power deposited into the plasma had an adverse effect on the uniformity.

  • PDF

저산소 농도 살충 챔버 시스템 시제작 및 박물관 해충 살충 성능 평가 (Trial Manufacture and Disinfection Evaluation of Anoxic Chamber System for Museum Insects)

  • 오준석;최정은;이장묵
    • 보존과학회지
    • /
    • 제28권4호
    • /
    • pp.377-385
    • /
    • 2012
  • 박물관에서 문화재 해충의 살충을 위해 사용되어 온 메틸브로마이드는 오존층 파괴물질로써 2015년 사용이 금지됨에 따라 대체법으로써 아르곤이나 질소를 사용한 저산소 농도 살충법이 도입되었다. 국립민속박물관에서는 국내 최초로 저산소 농도 살충법의 적용이 가능한 저산소 농도 살충 챔버 시스템을 시제작하여 설치하였다. 저산소 농도 살충 챔버 시스템은 챔버 내부 용량이 $0.5m^3$이며, 아르곤, 질소, 이산소탄소의 사용이 가능하다. 이 시스템은 산소 농도 0.01~20%, 온도 $10{\sim}50^{\circ}C$, 습도 30~80%를 자동적으로 제어가 가능하며, 산소 농도 제어는 설정값 이상으로 상승할 때마다 가습 가스와 건조 가스를 혼합하여 주입하는 방법을 채택하였다. 시운전을 위해 30일 동안 가동 결과, 산소 농도, 온도 및 습도가 일정하게 유지되었다. 그리고 권연벌레 애벌레와 성충, 애알락수시렁이 애벌레 대해 아르곤 가스를 사용하여 산소 농도 0.01%, 온도 $25^{\circ}C$ 및 습도 50% 환경에서 살충 성능을 평가한 결과, 권연벌레 성충은 3~5일, 애벌레는 7일, 애알락수시렁이 애벌레는 3일이 소요되어, 시제작된 저산소 농도 살충 챔버 시스템의 살충 성능을 확인할 수 있었다. 평가 결과로부터 저산소 농도 살충 챔버 시스템은 박물관에서 메틸브로마이드 대체법인 저산소 농도 살충법의 기술을 개발하는데 충분히 활용이 가능함을 확인하였다.

아연정광의 성분분석 및 챔버내 산소소모량 평가 (Analysis of Components and Oxygen Consumption Rate for Zinc Concentrates in a Closed Chamber)

  • 박해동;황은송
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.6-11
    • /
    • 2023
  • Objective: This study was conducted to identify the cause of suffocation accident. Methods: We analyzed the components of zinc concentrates by ICP-OES (inductively coupled plasma optical emission spectroscopy) and tested the oxygen consumption by zinc concentrates in a 13.2-liter closed chamber. Results: Zinc, sulfur and iron were the main components of the four types of zinc concentrates, and accounted for 76~89% by weight. Zinc concentrates (0.5 or 0.927 kg) depleted the oxygen concentration from 20.9% to 7.4~18.9% during seven days. The rate of oxygen consumption was in the range of 3.0~11.0 mM/day·kg-sample at 21~24℃ and around 95% of free air space within the closed chamber. Conclusion: Since zinc concentrate consumes oxygen in a confined space, measures should be taken to prevent suffocation accident (such as ventilation and monitoring of oxygen concentration).