Failure Mode Analysis for a Hyperbaric Oxygen Chamber (고압산소 치료기에 대한 고장모드 분석)

  • Jeon, Tae-Bo;Park, Seong-Bin
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.9-14
    • /
    • 2013
  • Reliability plays a pivotal role in the development of medical instruments. A hyperbaric oxygen chamber, as a medical/health device, is known to help medical therapy for diversity of diseases through provision of high purity oxygen. The use of hyperbaric oxygen chamber is expected to increase in the future and study to examine reliability and safety is needed. We have performed reliability assessment for a newly developed hyperbaric oxygen chamber in this study. We first briefly discussed the system structure and mechanism. We then performed FMEA (Failure Mode and Effect Analysis) for the chamber. We drew major failure modes affecting the system performance and performed in depth analysis for measuring the expected effects.

  • PDF

The Study of Effect on Oxygen Chamber for Recovery of Muscular Fatigue (산소 챔버의 근육 피로회복효과에 대한 연구)

  • Yoo, Su-Jeong;Nam, Eun-Young;Kim, Hyeong-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.2
    • /
    • pp.83-98
    • /
    • 2016
  • Objectives: This Study was designed to investigate the effect of Oxygen chamber to recover muscle fatigue. Methods: Twenty Subjects were divided into Oxygen Chamber Group (n=10) and Rest group (n=10). Subjects visited hospital two times, blood tests were performed 3 times for each visit. 1st blood test was performed in 4 hours hunger state. 2nd blood test was performed within 5 minutes after the 6 minutes bike exercise. 3rd blood test was performed after the 40 minutes Oxygen treatment or 40 minutes rest in bed. Blood test items were Lactate, Glucose, Lactate Dehydrogenase, Creatine Kinase, Free Fatty Acid. 2nd visit was applied 1st visit process, But Oxygen Chamber group was crossed over to Rest Group, Rest Group was crossed over to Oxygen Chamber group. The Blood test result was analyzed with paired T-test using SPSS for Windows version 21. Results: The reduction of Lactate in Oxygen Chamber Group (6.86±2.07 mmol/ℓ) was higher than Rest group (6.57±2.33 mmol/ℓ), but it was not statically significant (p=0.68). The reduction of Glucose in Oxygen Chamber Group (6.85±12.14 mg/dl) was lower than Rest group (7.60±9.83 mg/dl), but it was not statically significant (p=0.83). The reduction of Lactate Dehydrogenase in Oxygen Chamber Group (16.10±14.91 mmol/ℓ) was lower than Rest group (19.75±12.46 mg/dl), but it was not statically significant (p=0.41). The reduction of Creatine Kinase in Oxygen Chamber Group (13.40±5.69 U/ℓ) was lower than Rest group (15.25±8.01 U/ℓ), but it was not statically significant (p=0.41). The reduction of Free Fatty Acid in Oxygen Chamber Group (285.50±174.13 uEq/ℓ) was higher than Rest group (196.15±131.58 uEq/ℓ), but it was not statically significant (p=0.07). Conclusions: This study showed Oxygen chamber therapy could be effective to recover muscle fatigue.

Preliminary Hazard Analysis for a Hyperbaric Oxygen Chamber (고압 산소 치료기에 대한 예비위험분석)

  • Jeon, Tae-Bo
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.3-8
    • /
    • 2013
  • Reduction of risk plays a pivotal role in the development of medical instruments. A hyperbaric oxygen chamber, as a medical device, is known to help medical therapy for diversity of diseases through provision of high purity oxygen. The use of hyperbaric oxygen is expected to increase in the future and study to rigorously examine reliability and safety is needed. We have performed risk assessment for a newly developed hyperbaric oxygen chamber in this study. We first briefly discussed the system structure and concept of risk assessment for the study. Based on the hazards identified, we performed preliminary hazard analysis for the chamber.

  • PDF

Effects of Hyperbaric Oxygen Intervention on Alcohol-Induced Oxidative Stress and Hangover in Hyperbaric Oxygen Chamber (고압산소챔버 중재가 알코올에 의한 산화적 스트레스 및 숙취 해소에 미치는 영향)

  • Kwon, Hyeok Chan;Park, Soon Won;Cho, Hyun Jeong;Kang, Ji Hyun;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.175-182
    • /
    • 2018
  • The purpose of this study is to evaluate the reliability and effectiveness of hyperbaric oxygen chamber on alcohol-induced oxidative stress and hangover. In order to evaluate them, 20 healthy adults were tested for blood and hangover stress tests. When an exponential change was examined after 3 interventions (hangover drink, hyperbaric oxygen chamber, and normal chamber as placebo effect) of 1 hour, the heart rate of subjects experiencing a hyperbaric oxygen chamber showed a statistically significant decrease (p < 0.001). The tests of blood alcohol concentration (BAC) as for exquisite hematology analysis, glucose, creatinine, and AST (aspartate aminotransferase) as well as ALT (alanine aminotransferase) used as liver-damage indicator show that the hyperbaric chamber has the effective effect. In the test of lactic acid, CRP (c-reactive protein), cortisol, and creatinine, the hyperbaric chamber shows much more excellent effect than the hangover drink and normal chamber as control groups. Further studies on hyperbaric oxygen chamber intervention including this study could be very helpful for improving lives of both the patients and healthy people.

Effect and Safety of Oxygen Chamber Therapy on Cold Hypersensitivity: A Randomized, Controlled Trial (냉증에 대한 산소챔버의 임상 효능 및 안전성 연구)

  • Ha, Hun-Yong;Yoon, Dal-Hwan;Go, Ho-Yeon;Han, Yong-Dae;Kim, Nam-Sik;Nam, Eun-Young;Kim, Hyung-Jun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.123-139
    • /
    • 2013
  • Purpose: Cold hypersensitivity is regarded to be associated with blood circulation. This study is aims to evaluate the effects and safety of oxygen chamber therapy on cold hypersensitivity by comparing the temperature and Visual Analogue Scale. Methods: 42 outpatients who visited ${\bigcirc}{\bigcirc}$ University Oriental Hospital from July 11th, 2013 to August 28th, 2013 were analyzed. Patients were subjected to thermometer, and those with thermal difference greater than $0.3^{\circ}C$ between upper arm and palm and also with more than VAS 4 of cold hypersensitivity were diagnosed with cold hypersensitivity. 42 outpatients diagnosed with cold hypersensitivity are divided into two groups, one is the experimental group consisted of 21 patients and other was control group consisted of 21 patients. The experimental group had oxygen chamber therapy 10 times for 4 weeks. Thereafter the effects of oxygen chamber therapy on cold hypersensitivity was analyzed with t-text using SPSS for Windows version 21. Results: After the oxygen chamber therapy, experimental group had considerable improvement on cold hypersensitivity, in consequence of decreasing rate of thermal difference and VAS of cold hypersensitivity. Ear deafness and hand numbness were reported as an adverse effects in experimental group, but there was no serious adverse effects. Conclusions: This clinical trial showed oxygen chamber therapy could be effective and safe to reduce cold hypersensitivity.

Study on Co-incineration of Municipal Solid Waste and Organic Sludges (도시쓰레기와 유기성 하수 슬러지 혼합소각에 관한 연구)

  • Jurng, Jong-Soo;Chin, Sung-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.238-244
    • /
    • 2005
  • This study performs the pilot-plant experiments to evaluate the effect of the oxygen enrichment on the co-incineration of municipal solid waste and organic sludge from a wastewater treatment facility. The design capacity of the stoker-type incinerator pilot-plant is 150 kg/h. Combustion chamber temperatures were measured as well as the stack gas concentrations, i.e., NOx, CO, and the residual oxygen. The maximum ratio of organic sludge waste to the total waste input is 30%. Also the oxygen-enriched air with 23% of oxygen in supplied air is used for stable combustion. As the co-incineration ratio of the sludge increased up to 30% of the total waste input, the primary and the secondary combustion chamber temperature was decreased $to900^{\circ}C$ (primary combustion chamber), $750^{\circ}C$(secondary combustion chamber), respectively, approximately $200^{\circ}C$ below the incineration temperature of the domestic waste only (primary: $1,100^{\circ}C$, secondary: $950^{\circ}C$). However, if the supplied air was enriched to 22% oxygen content in air, the incinerator temperature was high enough to burn the waste mixture with 30% sludge, which has the heating value of 1,600 kcal/kg.

  • PDF

Oxygen Plasma Characterization Analysis for Plasma Etch Process

  • Park, Jin-Su;Hong, Sang-Jeen
    • Journal of the Speleological Society of Korea
    • /
    • no.78
    • /
    • pp.29-31
    • /
    • 2007
  • This paper is devoted to a study of the characterization of the plasma state. For the purpose of monitoring plasma condition, we experiment on reactive ion etching (RIE) process. Without actual etch process, generated oxygen plasma, measurement of plasma emission intensity. Changing plasma process parameters, oxygen flow, RF power and chamber pressure have controlled. Using the optical emission spectroscopy (OES), we conform to the unique oxygen wavelength (777nm), the most powerful intensity region of the designated range. Increase of RF power and chamber pressure, emission intensity is increased. oxygen flow is not affect to emission intensity.

Simulation of Inductively Coupled $Ar/O_2$ Plasma; Effects of Operating Conditions on Plasma Properties and Uniformity of Atomic Oxygen

  • Park, Seung-Kyu;Kim, Jin-Bae;Kim, Heon-Chang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.59-63
    • /
    • 2009
  • This paper presents two dimensional simulation results of an inductively coupled $Ar/O_2$ plasma reactor. The effects of operating conditions on the plasma properties and the uniformity of atomic oxygen near the wafer were systematically investigated. The plasma density had the linear dependence on the chamber pressure, the flow rate of the feed gas and the power deposited into the plasma. On the other hand, the electron temperature decreased almost linearly with the chamber pressure and the flow rate of the feed gas. The power deposited into the plasma nearly unaffected the electron temperature. The simulation results showed that the uniformity of atomic oxygen near the wafer could be improved by lowering the chamber pressure and/or the flow rate of the feed gas. However, the power deposited into the plasma had an adverse effect on the uniformity.

  • PDF

Trial Manufacture and Disinfection Evaluation of Anoxic Chamber System for Museum Insects (저산소 농도 살충 챔버 시스템 시제작 및 박물관 해충 살충 성능 평가)

  • Oh, Joonsuk;Choi, Jungeun;Lee, Jangmook
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.377-385
    • /
    • 2012
  • Anoxic treatments using argon and nitrogen gas in controlled atmospheres have been used as a alternative to methyl bromide for insect disinfection in museums. Anoxic chamber system was manufactured and installed at The National Folk Museum of Korea for the first time in Korea. The internal capacity of anoxic chamber is 0.5m3 in which is able to use argon, nitrogen and carbon dioxide gas. This system is equipped with oxygen concentration, temperature and ralative humidity control devices and automatically controlled oxygen concentration from 0.01 to 20%, temperature from 10 to $50^{\circ}C$ and relative humidity 30 to 80%. To control the oxygen concentration, anoxic chamber system is adopted semi-dynamic method which supplies mixture of humidified gas and dry gas whenever oxygen concentration in chamber becomes higher than setting value. It has kept regularly oxygen concentration, temperature and relative humidity for 20 days using argon gas. To evaluate the disinfection of cigarette beetle larvae and adults and varied carpet beetle larvae, the anoxic chamber system maintained 0.01% of oxygen concentration, $25^{\circ}C$ in temperature and 50% in relative humidity for 30 days. Cigarette beetle larvae were killed in 7 days and adults in 3~5 days. And varied carpet beetle larvae were killed in 3 days. It reaches the conclusion form the evaluation this anoxic chamber system can be used to develop anoxic treatment as an alternative of methyl bromide for insect disinfection of infested cultural properties in museums.

Analysis of Components and Oxygen Consumption Rate for Zinc Concentrates in a Closed Chamber (아연정광의 성분분석 및 챔버내 산소소모량 평가)

  • Hae Dong Park;Eun Song Hwang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.1
    • /
    • pp.6-11
    • /
    • 2023
  • Objective: This study was conducted to identify the cause of suffocation accident. Methods: We analyzed the components of zinc concentrates by ICP-OES (inductively coupled plasma optical emission spectroscopy) and tested the oxygen consumption by zinc concentrates in a 13.2-liter closed chamber. Results: Zinc, sulfur and iron were the main components of the four types of zinc concentrates, and accounted for 76~89% by weight. Zinc concentrates (0.5 or 0.927 kg) depleted the oxygen concentration from 20.9% to 7.4~18.9% during seven days. The rate of oxygen consumption was in the range of 3.0~11.0 mM/day·kg-sample at 21~24℃ and around 95% of free air space within the closed chamber. Conclusion: Since zinc concentrate consumes oxygen in a confined space, measures should be taken to prevent suffocation accident (such as ventilation and monitoring of oxygen concentration).