• Title/Summary/Keyword: Oxidation efficiency

Search Result 952, Processing Time 0.033 seconds

Physical and Chemical Management Practices for Improving Water Quality in Channel Catfish Ictalurus punctatus Aquaculture

  • Seo, Jin-Won
    • Journal of Aquaculture
    • /
    • v.15 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Research on practices for improving water quality in channel catfish Ictalurus punctatus ponds was conducted at the Auburn University Fisheries Research Station, Auburn, Alabama, in 1998 and 1999. The objective of this two-year study was to determine better management practices to enhance water quality and improve production efficiency. In the first year, oxidation of bottom soil by drying, tilling, and applying sodium nitrate was performed (dry-till and dry-till with sodium nitrate treatments). The second year, based on the results obtained during the first year, precipitation of phosphorus (P) from water by applying gypsum was compared to the dry-till treatment (dry-till and dry-till with gypsum treatments). Control ponds were not subjected to bottom drying, tilling, sodium nitrate, or gypsum treatment. Channel catfish fingerings were stocked at 15,000/ha. In the first year, water in ponds from dry-till and dry-till with sodium nitrate treatments had lower concentrations (P < 0.01) of soluble reactive P, nitrate ($NO_{3} ^{-}) and nitrite ($NO_{2} ^{-}) nitrogen (N), total ammonia ($NH_3$) nitrogen, total suspended solids and turbidity, and higher values of pH, Secchi disk visibility, total alkalinity, total hardness, and calcium ($Ca^{2+}) hardness than water in control ponds. Ponds of the dry-till treatment also had lower concentrations (P < 0.01) of total P and total N than control ponds. Total fish production and survival rate did not differ among the treatments (P > 0.05). The findings suggested that drying and tiling pond bosoms between crops could achieve water quality improvement. Applying sodium nitrate to dry, tilled pond bosoms did not provide water quality improvement. In the second year, the treatment with the best results from the first year, dry-till, was compared with a dry-till with gypsum treatment. Enough gypsum was applied to give a total hardness of about 200 mg/L, and gypsum was reapplied as needed to maintain the hardness. Compared to the control, dry-till and dry-till with gypsum treatments had lower concentrations (P < 0.01) of total and soluble reactive P, total N, and total $NH_3$-N, and higher concentrations (P < 0.01) of dissolved oxygen. Ponds of the duty-till with gypsum treatment also had lower concentrations (P < 0.01) of chlorophyll $\alpha$, chemical oxygen demand, and total alkalinity than the control. Total fish production and survival rate did not differ (P > 0.05) among the treatments. These findings suggest that drying and tilling pond bosoms between crops and treating low hardness waters with gypsum could achieve water Quality improvement.

Effects of Multi-stage Pilot Split Injection Strategy on Combustion and Emission Characteristics in a Single-Cylinder Diesel Engine (단기통 디젤엔진에서 다단 파일럿 분할 분사 전략이 연소 및 배기가스 특성에 미치는 영향)

  • Lee, Hyungmin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.692-698
    • /
    • 2020
  • This paper examines the effects of a multi-stage pilot split injection strategy on combustion and exhaust emission factors in a single-cylinder diesel engine. One analysis noted that in the single-injection condition, the maximum in-cylinder pressure and rate of heat release were highest. The pilot injection quantity was evenly divided, showing a tendency to decrease as the number of injections increased. In another injection condition, when the multi-stage pilot split injection strategy was applied, IMEP, engine torque, and combustion increased. The COVIMEP was greatest with the lowest combustion efficiency. The combustion ability was poor. In a single injection condition, the O2 concentration in the exhaust gas was the lowest and the CO2 was the highest. When the multi-stage split injection strategy was applied, the low temperature combustion process proceeded, and the oxidation rate of CO2 decreased while the emission level increased. In a single injection condition in which a locally rich mixture was formed, the HC emission level showed the highest results. A 55.6% reduction of NOx emission occurred under a three-stage pilot injection condition while conducting a multi-stage pilot split injection strategy.

A Study OH the Character and Activity of $TiO_2$ Photocatalysts Prepared With Various Condition (다양한 조건에서 제조된 $TiO_2$ 광촉매 특성 및 활성에 관한 연구)

  • Kim, Seung-Min;Youn, Tae-Kawun;Hong, Dae-Il;Kim, Sung-Kuk;Park, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.932-938
    • /
    • 2005
  • [ $TiO_2$ ] nanoparticles were prepared from the precipitation in $TiCl_4$ and the sol-gel profess in $Ti(OC_3H_7)_4$ as starting materials with various synthetic conditions. The samples were characterized by XRD, SEM, and TEM testing techniques. The photocatalytic degradation of congo red has been investigated in $TiO_2/UV$ process to evaluate photocatalytic activities for the samples. $TiO_2$ nanoparticles calcined at $400^{\circ}C$ had the best photocatalytic activity with the rate constant of the degradation of congo red as $0.0319\;min^{-1}$. The rate constant of $TiO_2$ photocatalysts was increased with the calcination temperature under $400^{\circ}C$ and decreased with the calcination temperature upper $400^{\circ}C$. In the case of $TiO_2$ photocatalysts, the photocatalytic activity wasn't greatly affected by the frequencies of usage. In the similar synthesis condition, the degradation efficiency of the $TiO_2$ particle prepared by $TiCl_4$ was increased to 8.8%, when the rate was compared with the sample prepared by $Ti(OC_3H_7)_4$. The photocatalytic activities of $TiO_2$ photocatalysts synthesized by $Ti(OC_3H_7)_4$ with various conditions were also discussed.

Removal of Natural Organic Matter using Potassium ferrate(VI) (Potassium ferrate(VI)를 이용한 자연유기물질 제거)

  • Lim, Mi-Hee;Kim, Myoung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.12
    • /
    • pp.1337-1344
    • /
    • 2007
  • In this research, we synthesized potassium ferrate(VI) acting as an oxidant, disinfectant, and coagulant, and used it to treat natural organic matter(NOM, HA and FA) in river water. The removal efficiencies obtained by $UV_{254}$ ranged from 20.7 to 73.6% for 10 mg/L HA and from 52.6 to 77.5% for 10 mg/L FA in Nakdong river sample as the ferrate dose varied from 2 to 46 mg/L(as Fe). However, the removal efficiencies by TOC analysis ranged from 0 to 20.3% for HA and from 0 to 26.6% for FA at the same ferrate doses. The removal efficiencies of NOM increased either with decreasing pH or with increasing temperature. The removal efficiency of HA by ferrate was comparable to those by traditional coagulants such as $Al_2(SO_4)_3{\cdot}18H_2O$, $FeSO_4{\cdot}7H_2O$, and FeO(OH). The reaction between ferrate and HA reached a steady state within 60 seconds, showing first-order with respect to the reaction time. The removal efficiencies of HA by traditional coagulants were improved by pretreatment of HA using a small amount of ferrate.

Bilolgical Activities of Conjugated Linoleic Acid (CLA) and Animal Products (Conjugated Linoleic Acid (CLA)의 생리활성과 축산식품)

  • Hur, S.J.;Lee, J.I.;Ha, Y.L.;Park, G.B.;Joo, S.T.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.427-442
    • /
    • 2002
  • Conjugated linoleic acid(CLA) is a collective term for a group of positional (c8, c10; c9, c11; c10, c12, and c11, c13) and geometric(cis,cis; cis,trans; trans,cis; and trans,trans) isomers of octadecadienoic acid (linoleic acid) with conjugated double bond system. CLA has been shown to have a variety of biological effects. Major effects of CLA on health, such as anti-cancer, anti-oxidation, anti-atherosclerosis and improving immuno-responses, might be derived or partially derived from the alternated lipid metabolism after CLA feeding. Most of studies on the effect of CLA on fat metabolism are concentrated on rats, mice, pigs and other mammals. The CLA inhibited carcinogen-induced neoplasia in several animal models and inhibited the proliferation of human malignant melanoma, colorectal and breast cancer cells and CLA reduced the atherosclerosis. Several studies have determined the antioxidant property of CLA; however, the property still remains controversial. Some of the studies have shown that CLA acted as an antioxidant, whereas some other studies have demonstrated that CLA might be a prooxidant. Several studies suggested that CLA could reduce fat accumulation in mammals. CLA was suggested to promote muscle growth and reduce fat deposition in mouse, and improve feed efficiency in rats. CLA has been shown to inhibit the activity of stearoyl-CoA reductase. CLA also reduced the content of arachidonic acid. Since arachidonic acid, and eicosapentaenoic acid (EPA) and docosahexenoic acid (DHA) are synthesized by different pathways, reducing the synthesis of arachidonic acid may not mean reducing that of EPA and DHA. Many sutdies have been shown biological effects of CLA. Therefore, further research is needed to answer the following questions: 1) how to synthesize the new CLA by new methods, 2) why CLA has shown biological effects, 3) how to increase CLA effects in animal products.

Removal of As(III) by Pilot-Scale Filtration System Separately Packed with Iron-Coated Sand and Manganese-Coated Sand (철 및 망간코팅사를 분리 충진시킨 파일럿 여과시스템에 의한 3가 비소 제거)

  • Kim, Kwang-Seob;Song, Ki-Hoon;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.8
    • /
    • pp.878-883
    • /
    • 2006
  • Removal efficiency of As(III) was investigated with a pilot-scale filtration system packed with an equal amount(each 21.5 kg) of manganese-coated sand(MCS) in the bottom and iron-coated sand(ICS) in the top. Height and diameter of the used column was 200 cm and 15 cm, respectively. The As(III) solution was introduced into the bottom of the filtration system with a peristaltic pump at a speed of $5{\times}10^{-3}$ cm/s over 148 days. Breakthrough of total arsenic in the mid-sampling position(end of the MCS bed) and final-sampling position(end of the ICS bed) was started after 18 and 44 days, respectively, and then showed a complete breakthrough after 148 days. Although the breakthrough of total arsenic in the mid-sampling position was started after 18 days, the concentration of As(III) in this effluent was below 50 ppb up to 61 days. This result indicates that MCS has a sufficient oxidizing capacity to As(III) and can oxidize 92 mg of As(III) with 1 kg of MCS up to 61 days. When a complete breakthrough of total arsenic occurred, the removed total arsenic by MCS was calculated as 79.0 mg with 1 kg MCS. As variation of head loss is small at each sampling position over the entire reaction time, it was possible to operate the filtration system with ICS and MCS for a long time without a significant head loss.

Characterization of Diethyl Phthalate(DEP) Removal using Ozone, UV, and Ozone/UV Combined Processes (오존, UV, 오존/UV 혼합 공정을 이용한 Diethyl Phthalate(DEP)의 제거특성 연구)

  • Jung, Yeon-Jung;Oh, Byung-Soo;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2006
  • Three candidate processes(ozone alone, UV alone and ozone/UV combined processes) were evaluated for the removal of diethyl phthalate(DEP). Of the candidates, the ozone/UV process showed the highest removal efficiency of DEP. To elucidate a major oxidant for DEP oxidation in the ozone/UV process, the effects of pH and hydroxyl radical($OH^{\circ}$) scavenger were investigated. As a result, it was found that $OH^{\circ}$ plays a important role for DEP elimination. Meanwhile, the direct reaction between ozone and DEP was negligible. Observing the pseudo first-order rate of DEP removal in ozone alone and ozone/UV processes, the different pattern was obtained from two processes. The ozone/UV process was well plotted following the pseudo first-order. but in the ozone alone process the rate was divided into fast and slow phases. DEP degradation characteristics in ozone alone and ozone/UV was also investigated by observing the HPLC spectrum. We detected unknown compounds that were guessed to DEP byproducts and observed the formation and disappearance of the unknown compounds according to reaction time. Observing of high removal of TOC in ozone/UV combined process, it was found that DEP and DEP byproducts are completely oxidized by ozone/UV combined process.

Development of Various Pilot Scale's Ultrasound Systems and Sonodegradation of Naphthalene in Water (다양한 형태의 Pilot Scale 초음파 시스템 개발 및 나프탈렌 분해효율 검증)

  • Park, Jong-Sung;Lee, Ha-Yun;Han, Jong-Hun;Her, Nam-Guk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.281-288
    • /
    • 2011
  • Recently, researches that a variety of contaminants in water are removed by sonolysis technology with oxidation and pyrolysis process from cavitation were conducted. However, there are few studies for sonochemical treatment by a pilot-scale ultrasound system. This research focused on developing pilot-scale ultrasound systems, which could be an continuously effective treatment for a large volumes of contaminants, and demonstrating the feasibility of utilizing these systems to remove naphthalene from groundwater. V-120 type reactor was found to be 1.4~2.2 times higher effective than the normal type. A total of three different pilot scale's systems consisted of installing effluent and irrigation water in order to be a continuos system, including supplemental additives, and applying a V-120 type reactor and a external cooling cycle system. Naphthalene levels treated by three systems were lower than a recommended guideline of naphthalene for drinking water in EPA. Especially, the naphthalene removal efficiencies of PS1 and PS2 systems were over 97%. The pilot-scale continuous ultrasound clean-up system delivered over 84~95% naphthalene removal efficiency for treatment of 10~20 liter of groundwater. In addition, the ultrasound system could be successfully applied to the conditions of artificial and genuine groundwater contaminated with naphthalene.

Identification of Internal Resistance of Microbial Fuel Cell by Electrochemical Technique and Its Effect on Voltage Change and Organic Matter Reduction Associated with Power Management System (전기화학적 기법에 의한 미생물연료전지 내부저항 특성 파악 및 전력관리시스템 연계 전압 변화와 유기물 저감에 미치는 영향)

  • Jang, Jae Kyung;Park, Hyemin;Kim, Taeyoung;Yang, Yoonseok;Yeo, Jeongjin;Kang, Sukwon;Paek, Yee;Kwon, Jin Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.220-228
    • /
    • 2018
  • The internal resistance of microbial fuel cell (MFC) using stainless steel skein for oxidizing electrode was investigated and the factors affecting the voltage generation were identified. We also investigated the effect of power management system (PMS) on the usability for MFC and the removal efficiency of organic pollutants. The performance of a stack microbial fuel cell connected with (PMS) or PMS+LED was analyzed by the voltage generation and organic matter reduction. The maximum power density of the unit cells was found to be $5.82W/m^3$ at $200{\Omega}$. The maximum current density was $47.53A/m^3$ without power overshoot even under $1{\Omega}$. The ohmic resistance ($R_s$) and the charge transfer resistance ($R_{ct}$) of the oxidation electrode using stainless steel skein electrode, were $0.56{\Omega}$ and $0.02{\Omega}$, respectively. However, the sum of internal resistance for reduction electrode using graphite felts loaded Pt/C catalyst was $6.64{\Omega}$. Also, in order to understand the internal resistance, the current interruption method was used by changing the external resistance as $50{\Omega}$, $300{\Omega}$, $5k{\Omega}$. It has been shown that the ohm resistance ($R_s$) decreased with the external resistance. In the case of a series-connected microbial fuel cell, the reversal phenomenon occurred even though two cells having the similar performance. However, the output of the PMS constantly remained for 20 hours even when voltage reversal occurred. Also the removal ability of organic pollutants (SCOD) was not reduced. As a result of this study, it was found that buffering effect for a certain period of time when the voltage reversal occurred during the operation of the microbial fuel cell did not have a serious effect on the energy loss or the operation of the microbial fuel cell.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.