• Title/Summary/Keyword: Oxidation/Reduction

Search Result 1,442, Processing Time 0.034 seconds

Study of optimal reduction plan for wastewater sludge generated from oil refinery (정유 공장에서 발생된 폐수 슬러지의 최적 감량화 방안 연구)

  • Choi, Jae-Woo;Jung, Jong-Min;Shim, Natalia;Lee, Sang-Hyup;Park, Cheol-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.395-406
    • /
    • 2010
  • In this study, anaerobic digestion, electro-oxidation and electro-fenton oxidation processes were investigated to reduce oily refinery sludge. Anaerobic digestion process was not suitable for oily activated sludge reduction because of characteristics itself and, as experimental results revealed, reduction efficiency was low for electro-oxidation process. However, 40% total suspended solid reduction of oily activated sludge was obtained by electro-fenton oxidation process, operating at pH=1, 0.5 A and $Fe^{2+}$:$H_2O_2$ ratio = 1:30. In addition, higher reduction efficiency was obtained as reaction time was increased (30, 60, 90, 120 min) despite of low $H_2O_2$ concentration. From the results, it has been investigated that electro-fenton oxidation is efficient process for oily activated sludge reduction.

Characteristics of Powder Prepared from Unirradiated $UO_2$ Pellets by Oxidation and Reduction Method ($UO_2$ 소결체의 산화/환원에 의해 제조된 분말 특성)

  • 김봉구;송근우;이정원;배기광;양명승;박현수
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.4
    • /
    • pp.471-481
    • /
    • 1995
  • Unirradiated UO2 pellets were pulverized by oxidation in air at 40$0^{\circ}C$, and the oxidized powders were reduced in H2 and CO atmospheres at $600^{\circ}C$. During the oxidation of UO2 at 40$0^{\circ}C$, intergranular cracks which caused the spallation were mainly developed by the volume contraction due to the formation of intermediate phase (U4O9 or U3O7). As oxidation proceeded, U3O8 finally formed. As the oxidation/reduction cycles were repeated, the powder surface became coarser, specific surface area was increased and average particle size was decreased. The sintered densities of the powder were increased by the oxidation/reduction cycle due to the characteristic changes of the powder.

  • PDF

Effect of High Temperature Treatment and Subsequent Oxidation anil Reduction on Powder Property of Simulated Spent Fuel

  • Song, Kun-Woo;Kim, Young-Ho;Kim, Bong-Goo;Lee, Jung-Won;Kim, Han-Soo;Yang, Myung-Seung;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.366-372
    • /
    • 1996
  • The simulated spent PWR fuel pellet which is corresponding to the turnup of 33,000 MWD/MTU is prepared by adding 11 fission-product elements to UO$_2$. The simulated spent fuel pellet is treated at 40$0^{\circ}C$ in air (oxidation), at 110$0^{\circ}C$ in air (high-temperature treatment), and at $600^{\circ}C$ in hydrogen (reduction). The product is treated through additional addition and reduction up to 3 cycles. Pellets are completely pulverized by the first oxidation, and the high-temperature treatment causes particle and crystallite to grow and surface to be smooth, and thus particle size significantly increases and surface area decreases. The reduction following the high-temperature treatment decreases much the particle size by means of the formation of intercrystalline cracks. The particle size decreases a little during the second oxidation and reduction cycle and then remains nearly constant during the third and fourth cycles. Surface area of pounder increases progressively with the repetition of oxidation and reduction cycles, mainly due to the formation of Surface cracks. The degradation of surface area resulting from high-temperature treatment is restored by too subsequent resulting oxidation and reduction cycles.

  • PDF

NO Reduction and Oxidation over PAN based-ACF

  • Kim, Je-Young;Lee, Jong-Gyu;Hong, Ik-Pyo
    • Carbon letters
    • /
    • v.1 no.1
    • /
    • pp.17-21
    • /
    • 2000
  • Catalytic reduction and oxidation of NO over polyacrylonitrile based activated carbon fibers (PAN-ACF) under various conditions were carried out to develop removal process of NO from the flue gas. The effect of temperature, oxygen concentration and the moisture content for the reduction of NO with ammonia as a reducing agent was investigated. The reduction of NO increased with the oxygen concentration, but decreased with the increased temperature. The moisture content in the flue gas affects the reduction of NO as the inhibition of the adsorption of the other components and the reaction on the surface of ACE For the oxidation of NO to $NO_2$ over PAN-ACF without using a reducing gas, it showed the temperature and the oxygen concentration of the flue gas are the important factors for the NO conversion in which the conversion increased with oxygen concentration and decreased with the temperature increase and might be the alternative option for the selective catalytic reduction process.

  • PDF

Relationship Between Tyrosinase Inhibitory Action and Oxidation-Reduction Potential of Cosmetic Whitening Ingredients and Phenol Derivatives

  • Sakuma, Katsuya;Ogawa, Masayuki;Sugibayashi, Kenji;Yamada, Koh-ichi;Yamamoto, Katsumi
    • Archives of Pharmacal Research
    • /
    • v.22 no.4
    • /
    • pp.335-339
    • /
    • 1999
  • The oxidation-reduction potentials of cosmetic raw materials, showing tyrosinase inhibitory action, and phenolic compounds structurally similar to L-tyrosine were determined by cylcic voltammetry. The voltammograms obtained could be classified ito 4 patterns (patterns 1-4). Patterns 1, characterized by oxidation and reduction peaks as a pair, was observed with catechol, hydroquinone or phenol, and pattern 2 exhibiting another oxidation peak in addition to oxidation and reduction peaks as a pair was found with arbutin, kojic acid, resorcinol, methyl p-hydroxybenzoate and L-tyrosine as the substrate of tyrosinase. Pattern 3 with an independent oxidation peak only was expressed by L-ascorbic acid, and pattern 4 with a reduction peak only at high potentials, by hinokitiol. The tyrosinase inhibitory activity of these compounds was also evaluated using the 50% inhibitory concentration ($IC_{50}$) and the inhibition constant (Ki) as parameters. Hinokitiol, classified as patterns 4, showed the highest inhibitory activity (lowest $IC_{50}$ and Ki). Hydroquinone showing the second highest activity belonged to pattern 1, which also included compounds exhibiting pattern 2 was relatively low with Ki values being in the order of 10-4 M. Although there was no consistent relationship between oxidation-reduction potentials and tyrosinase inhibitory action, the voltammetry data can be used as an additional index to establish the relationship between the structure and the tyrosine inhibitory activity.

  • PDF

Effects of Organic Matter and pH on Chromium Oxidation Potential of Soil

  • Chung, Jong-Bae;Eum, Jin-Sup
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.5
    • /
    • pp.346-351
    • /
    • 2001
  • Oxidation of Cr(III) to Cr(VI) can increase availability and toxicity of chromium. In this study, possible mechanisms by which pH and organic matter can control the chromium oxidation and reduction in soil system were examined using four soils of different pHs and organic matter contents. Reduction of Mn-oxides occurred in the soils of higher organic matter content (4.0%), but Mn-oxide was quite stable during the incubation in the soil of pH 7.0 and 0.5% organic matter content. Manganese oxides can be reductively dissolved at lower pH and higher organic matter conditions. The soil of pH 7.0 and 4.0% organic matter content showed the highest Cr-oxidation potential. Reduction of soluble Cr(VI) was observed in all the soils examined. The most rapid reduction was found in soil of pH 5.5 and 4.0% organic matter content, but the reduction was slow in soil of pH 7.0 and 0.5% organic matter content. Thus, the reductive capacity of organic matter added soils was much higher as compared to other two soils of lower organic matter content. In all the soils examined, the reductive capacity of soluble chromium was much higher than the oxidative capacity. Organic matter was found to be the most important controlling factor in the chromium oxidation and reduction. Reduction of Cr(VI) to Cr(III) could be a potentially useful remediation or detoxification process, and availability and toxicity of chromium in soil would be controlled by controlling organic matter content and pH of the soils.

  • PDF

Improving the Reactivity and Harmlessness of Recalcitrant Contaminants by Reduction-oxidation-linked Process (환원-산화 연계처리를 통한 니트로벤젠의 반응성 향상 및 무해화 연구)

  • Kwon, Hee-Won;Hwang, Inseong;Kim, Young-Hun
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1205-1211
    • /
    • 2020
  • In this study, the applicability of reduction-oxidation-linked treatment was evaluated for nitrobenzene and a by-product by analyzing the reaction kinetics. Nitrobenzene showed very low reactivity to persulfate that was activated using various methods. Nitrobenzene effectively reacted through the reduction process using Zero-Valent Iron (ZVI). However, aniline, a toxic substance, was produced as a by-product. Reduction-oxidation-linked treatment is a method that can allow the oxidative degradation of aniline after reducing nitrobenzene to aniline. The experimental results show improved reactivity and complete decomposition of the by-product. Improved reactivity and decomposition of the by-product were observed even under conditions in which the reduction-oxidation reaction was induced simultaneously. No activator was injected for persulfate activation in the process of reducing oxidant linkage, and the activation reaction was induced by ferrous iron eluted from the ZVI. This indicates that this method can be implemented relatively simply.

Effect of Electrochemical Oxidation-Reduction Cycles on Surface Structures and Electrocatalytic Oxygen Reduction Activity of Au Electrodes

  • Lim, Taejung;Kim, Jongwon
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.5
    • /
    • pp.310-316
    • /
    • 2016
  • Oxidation-reduction cycling (ORC) procedures are widely used for cleaning nanoparticle surfaces when investigating their electrocatalytic activities. In this work, the effect of ORC on the surface structures and electrocatalytic oxygen reduction activity of Au electrodes is analyzed. Different structural changes and variations in electrocatalysis are observed depending on the initial structure of the Au electrodes, such as flat bulk, nanoporous, nanoplate, or dendritic Au. In particular, dendritic Au structures lost their sharp-edge morphology during the ORC process, resulting in a significant decrease in its electrocatalytic oxygen reduction activity. The results shown in this paper provide an insight into the pretreatment of nanoparticle-based electrodes during investigation of their electrocatalytic activities.

Dyeability and Antibacterial Activity of Ginkgo Biloba Leaf Extract Using Three Kinds of Aqueous Extraction Solvents. (세가지 수계 추출 용매를 사용한 은행잎 추출액의 염색성 및 항균성)

  • 김정임;최영희;권오경
    • Textile Coloration and Finishing
    • /
    • v.16 no.2
    • /
    • pp.8-14
    • /
    • 2004
  • The purpose of this study was to investigate dyeing properties and antibacterial activities of cotton and silk fabrics treated with Ginkgo biloba leaf extracted with three kinds of aqueous solvents: distilled water, electrolytic reduction water and electrolytic oxidation water. The optimum dyeing condition of Ginkgo biloba leaf was 120 min at 8$0^{\circ}C$. Electrolytic reduction water had the highest dyeability to both cotton and silk compared with electrolytic oxidation water and distilled water. A color of extract by distilled water and electrolytic oxidation water showed yellowish Yellow Red, extract by electrolytic reduction water showed reddish Yellow Red. Irrespective of kinds of extraction solvents, appropriate acidity of medium was pH 9∼11 and pH 3 for cotton and silk fabrics, respectively. Colorfastness to laundering and Light fastness showed generally low but crocking fastness was excellent. Antibacterial activities of the treated fabrics above were 99.9%.