• Title/Summary/Keyword: Oxidants Formation

Search Result 48, Processing Time 0.022 seconds

Formation of Mixed Oxidants and Inactivation of E. coil by the Electrochemical Process using a Grid Shape Pt/Ti Electrode (Pt/Ti 격자형 평판 전극을 이용한 혼합 산화제 생성 및 E. coli 불활성화)

  • Jung, Yeon Jung;Oh, Byung Soo;Park, Sang Yeon;Baek, ko Woon;Kang, Joon-Wun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.851-855
    • /
    • 2006
  • The aim of this study was to investigate characteristics of formation of mixed oxidants and some aspects of the performance of electrochemical process as an alternative disinfection strategy for water purification. The study of electrochemical process has shown free chlorine to be produced, but smaller amounts of stronger oxidants, such as ozone, hydrogen peroxide and OH radicals, were also generated. The formation of ozone and hydrogen peroxide increased with increasing electric conductivity, but was limited at conductivities greater than 0.6 mS/cm. Also, formation of OH radical was enhanced as electric conductivity was increased to 0.9 mS/cm and The stead-state concentrations of OH radical were calculated at $1.1{\sim}6.4{\times}10^{-14}M$. Using E. coti, inactivation kinetic studies were performed. With the exception of free chlorine, the role of mixed oxidants, especially OH radical, was investigated for enhancement of the inactivation rate.

Evaluation of Disinfection Characteristics for Mixed Oxidants Produced by Electro-chemical Method (전기분해 방식에 의한 혼합산화제 소독 특성 평가)

  • Lee, Kyung-Hyuk;Lim, Jae-Lim;Lee, Doo-Jin;Kim, Seong-Su;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.625-631
    • /
    • 2005
  • Disinfection characteristics of mixed oxidants produced by mean of electro-chemical method were evaluated. Inactivation rate of B. subtilis spore on the mixed oxidants were similar with that of chlorine. Based on the experimental results, activation energy of mixed oxidants and chlorine with B. subtilis spore at pH 8.3 were calculated as 30.8, $34.7kJ{\cdot}mol^{-1}$ respectively. UV absorption spectrum of both chlorine and mixed oxidants present similar. Molar extinction coefficients of chlorine and mixed oxidants at 292nm, which is maximum absorption wavelength of $OCl^-$ were 357, $377M^{-1}cm^{-1}$, respectively. Disinfectant decay rate and formation rate of THM in the S WTP filtrate also shows insignificant difference for both mixed oxidants and chlorine. In consequent, it was confirmed that high portion of chlorine presents in the mixed oxidants.

Numerical Simulation of Complicated Photochemical Reactions Occurring in the Atmosphere (대기내 발생하는 복잡한 광화학반응에 대한 수치실험)

  • Won Gyeong-Mee;Kim Yoo-Keun;Lee Haw-Woon;Kim Hee-Jeoung
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.203-209
    • /
    • 2006
  • In predicting oxidants concentration, the most important fact is to select a suitable photochemical reaction mechanism. Sensitivity analysis of $O_3$ and other important photochemical oxidants concentrations was conducted by using CBM-IV model. The predicted oxidants concentration was considerably related with the initial concentration of formaldehyde, $[NO_2]/[NO],\;NO_x$, RH and RCHO. As the initial concentration of formaldehyde increased, concentration of $NO_2$ increased. $O_3$ concentration was proportional to the $[NO_2]/[NO]$ ratio. When the initial concentrations of RH and RCHO were high, photochemical reaction was more reactive, including more rapid conversion of NO to $NO_2$ and increased oxidants. Also, the sensitivities of ozone formation to rate constants, $K_l,\;K_2\;and\;K_3$ in the $NO_2$ photolysis were studied.

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(I) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(I))

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.49-60
    • /
    • 2009
  • Fabrication and oxidants formation of 1 and 2 component metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru, Pt, Sn, Sb and Gd) were used for the 1 and 2 component electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1 h. The removed RhB per 2 min and unit W for one component electrode decreased in the following sequences: Ru/Ti>Sb/Ti>Pt/Ti>Gd/Ti>Sn/Ti. The concentration of oxidants generated in 1 and 2 component electrodes was in the order of: $ClO_2$> free Cl>$H_2O_2>O_3$. OH radical was not generated from in entire one and two component electrodes. RhB degradation rate and generated oxidants of the Ru-Sn=9:1 electrode was higher than that of the two component electrode. The exact relationship between the removal of RhB and the generated oxidants concentration was not obvious. However, it was assumed that electrode with high RhB decolorization had high oxidant concentration.

Effect of Disinfection Process Combination on E. coli Deactivation and Oxidants Generation (E. coli 불활성화와 산화제 생성에 미치는 소독 공정 결합의 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.891-898
    • /
    • 2011
  • The aim of this research was to evaluate the effect of combination of disinfection process (electrolysis, UV process) on Escherichia coli (E. coli) disinfection and oxidants (OH radical, $ClO_2$, HOCl, $H_2O_2$ and $O_3$) generation. The effect of electrolyte type (NaCl, KCl and $Na_2SO_4$) on the E. coli disinfection and oxidants generation were evaluated. The experimental results showed that performance of E. coli disinfection of electrolysis and UV single process was similar. Combination of electrolysis and UV process enhanced the E. coli disinfection and 4-carboxybenzaldehyde (4-CBA, indicator of the generation of OH radical) degradation. It is clearly showed synergy effect on disinfection and OH radical formation. However chlorine ($ClO_2$, HOCl) and oxygen type ($H_2O_2$, $O_3$) oxidants were decreased with the combination of two process. In electrolysis + UV complex process, electro-generated $H_2O_2$ and $O_3$ were reacted with UV light of UV-C lamp and increased 4-CBA degradation(increase OH radical). Disinfection of electrolyte of chlorine type was higher than that of the sulfate type electrolyte due to the higher generation of OH radical and oxidants.

A Study on the Preparation of the Dimensionally Stable Anode(DSA) with High Generation Rate of Oxidants(II) (산화제 생성율이 높은 촉매성 산화물 전극(DSA)의 개발에 관한 연구(II))

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.61-72
    • /
    • 2009
  • Fabrication and oxidants production of 3 or 4 components metal oxide electrode, which is known to be so effective to destruct non-biodegradable organics in wastewater, were studied. Five electrode materials (Ru as main component and Pt, Sn, Sb and Gd as minor components) were used for the 3 or 4 components electrode. The metal oxide electrode was prepared by coating the electrode material on the surface of the titanium mesh and then thermal oxidation at $500^{\circ}C$ for 1h. The removed RhB per 2 min and unit W of 3 components electrode was in the order: Ru:Sn:Sb=9:1:1 > Ru:Pt:Gd=5:5:1 > Ru:Sn=9:1 > Ru:Sn:Gd=9:1:1 > Ru:Sb:Gd=9:1:1. Although RhB decolorization of Ru:Sn:Sb:Gd electrode was the highest among the 4 components electrode, the RhB decolorization and oxidants formation of the Ru:Sn:Sb=9:1:1 electrode was higher than that of the 3 and 4 components electrode. Electrogenerated oxidants (free Cl and $ClO_2$) of chlorine type in 3 and 4 components electrode were higher than other oxidants such as $H_2O_2\;and\;O_3$. It was assumed that electrode with high RhB decolorization showed high oxidant generation and COD removal efficiency. OH radical which is electrogenerated by the direct electrolysis was not generated the entire 3 and 4 components electrode, therefore main mechanism of RhB degradation by metal oxide electrode based Ru was considered indirect electrolysis using electrogenerated oxidants.

PULMONARY ANTIOXIDANT DEFENSE MECHANISM (호흡기계의 항산화 방어기전)

  • 이영구;손형옥;임흥빈;이동욱
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.14 no.2
    • /
    • pp.168-195
    • /
    • 1992
  • Pulmonary system is a target organ and primary defense mechanism against environmental oxidants and polutants. Enzymatic and nonenzymatic antioxdant defense mechanisms undoubtedly protect the lung from oxidants even endogenous oxidative stress. In addition, new ways of augmenting pulmonary antioxidant defenses are developed, which can be used to support the intrinsic antioxidants. Therefore, improved understanding of antioxidant defense mechanisms will increase our knowledge of the cause and will suggest rational approaches for treating and preventing oxidant-induced lung injury. In this review, we discuss the formation and scavenging of free radicals, and the strategies for antioxidant defense of pulmonary system.

  • PDF

Water Treatment Method for Removal of Trihalomethanes, Pesticides, Heavy Metals and Detergent in Drinking Water (1). -Effective Removal Method of Trihalomethanes in Drinking Water- (상수중 Trihalomethanes, 농약, 중금속 및 합성세제의 효율적인 제거를 위한 수처리 방법 제 1보. -상수중 Trihalomethanes의 효율적인 제거방법-)

  • Park, Jong-Woo;Kim, Jang-Eok
    • Applied Biological Chemistry
    • /
    • v.37 no.6
    • /
    • pp.472-479
    • /
    • 1994
  • This study was conducted to determine the effective removal method of THMs and humic material in drinking water when the doses of oxidants, coagulants, and activated carbon, and the points of oxidants treatment were changed in the drinking water treatment process. The inhibition of THMs formation and the removal of humic matter were more effectively achieved by $ClO_2$ than by other oxidants, $Cl_2,\;NH_2Cl,\;KMnO_4\;and\;O_3$. By changing the point of oxidant treatment, the formation of THMs was reduced by about 36.7 to 8.2% on treatment after coagulation, but the content of humic matter was not affected. The coagulation efficiency of alum and ferric sulfate to coagulate organic materials in water was affected by the molecular weight of humic matter in drinking water. The treatment of activated carbon after filtration was found to be more effective than that before oxidation in inhibiting THMs formation and removing THMs.

  • PDF

Formation Mechanism of Chlorate ($ClO_3\;^-$) by Electrochemical Process (전기화학적 공정에 의한 클로레이트의 생성메커니즘)

  • Baek, Ko-Woon;Jung, Yeon-Jung;Kang, Joon-Wun;Oh, Byung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.627-634
    • /
    • 2009
  • This study was done to find out the formation mechanism of chlorate by electrochemical process using chloride ion ($Cl^-$) as an electrolyte. Firstly, the effective factors such as pH and initial chloride concentration were figured out to see the formation property of chlorate during electrolysis. And the relation of free chlorine, and mixed oxidants such as OH radical and ozone with chlorate were estimated to concretize the formation mechanism. As a result, it was found that the major reaction of chlorate formation would be electrochemical reaction with free chlorine, and also the direct oxidation of chloride ion and the reaction by OH radical were participated in the formation of chlorate. Moreover, it was observed that formed chlorate was oxidized to perchlorate. Lastly, the optimum condition was recommended by comparing free chlorine with chlorate concentration during the electrochemical process with the different electrode separation.

Effect of Water Quality of Artificial Sewage on E. coli Disinfection Using Electrolysis Process (전기분해 공정을 이용한 E. coli 소독에 미치는 인공하수 수질의 영향)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1115-1124
    • /
    • 2011
  • There is an increasing incidence in health problems related to environmental issues that originate from inadequate treatment of sewage. This has compelled scientists to engage in innovative technologies to achieve a effective disinfection process. Electrolysis has emerged as one of the more feasible alternatives to conventional disinfection process. The objectives of the present paper were to investigate the effect of chemical characteristics on oxidant formation and Escherichia coli (E. coli) disinfection in synthetic sewage effluents. The influence of parameters such as COD, SS, T-N and T-P were investigated using laboratory scale batch reactor. The results showed that the higher COD, T-N and T-P concentration, the lower N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) degradation and E. coli disinfection was observed. The order of effect of RNO degradation and E. coli disinfection was T-P > COD > T-N > SS. When 4 parameter of water quality were worked simultaneously, oxidants formation and disinfection was decreased with increase of the concentration of sewage. To increase of the disinfection performance, the increase of disinfection time or electric power was need.