• Title/Summary/Keyword: Overload condition

검색결과 116건 처리시간 0.035초

수열합성법을 이용한 Flower-Like 형상의 Al2O3 Nanostructure 제조 및 BN/Al2O3 복합체의 방열 특성 연구 (Preparation of Flower-Like Al2O3 Nanostructures by Hydrothermal Synthesis and Study of Thermal Properties of BN/Al2O3 Composites)

  • 송노건;정용진
    • 한국전기전자재료학회논문지
    • /
    • 제36권6호
    • /
    • pp.633-637
    • /
    • 2023
  • Recently, with the development of the smart device market, the integration of high-functional devices has increased the heat density, causing overload of the device, and resulting in various problems such as shortened lifespan, performance degradation, and failure. Therefore, research on heat dissipation materials is being actively conducted to realize next-generation electronic products. The heat dissipation material is characterized in that it is easy to dissipate heat due to its high thermal conductivity and minimizes leakage current flowing through the heat dissipation material due to its low electrical conductivity. In this study, flower-shaped Al2O3 and BN composites were engineered with a simple hydrothermal synthesis approach, and their thermal conductivity characteristics were compared and evaluated for each synthesis condition for the application to a heat dissipation material. Spherical BN and flower-shaped Al2O3 were easily obtained, and SEM/EDS analyses confirmed the uniform presence of BN between the Al2O3, and it can be expected that these shapes can affect the thermal conductivity.

A real-time hybrid testing method for vehicle-bridge coupling systems

  • Guoshan Xu;Yutong Jiang;Xizhan Ning;Zhipeng Liu
    • Smart Structures and Systems
    • /
    • 제33권1호
    • /
    • pp.1-16
    • /
    • 2024
  • The investigation on vehicle-bridge coupling system (VBCS) is crucial in bridge design, bridge condition evaluation, and vehicle overload control. A real-time hybrid testing (RTHT) method for VBCS (RTHT-VBCS) is proposed in this paper for accurately and economically disclosing the dynamic performance of VBCSs. In the proposed method, one of the carriages is chosen as the experimental substructure loaded by servo-hydraulic actuator loading system in the laboratory, and the remaining carriages as well as the bridge structure are chosen as the numerical substructure numerically simulated in one computer. The numerical substructure and the experimental substructure are synchronized at their coupling points in terms of force equilibrium and deformation compatibility. Compared to the traditional iteration experimental method and the numerical simulation method, the proposed RTHT-VBCS method could not only obtain the dynamic response of VBCS, but also economically analyze various working conditions. Firstly, the theory of RTHT-VBCS is proposed. Secondly, numerical models of VBCS for RTHT method are presented. Finally, the feasibility and accuracy of the RTHT-VBCS are preliminarily validated by real-time hybrid simulations (RTHSs). It is shown that, the proposed RTHT-VBCS is feasible and shows great advantages over the traditional methods, and the proposed models can effectively represent the VBCS for RTHT method in terms of the force equilibrium and deformation compatibility at the coupling point. It is shown that the results of the single-degree-of-freedom model and the train vehicle model are match well with the referenced results. The RTHS results preliminarily prove the effectiveness and accuracy of the proposed RTHT-VBCS.

유한요소분석법을 이용한 치근형 임플랜트의 응력분포에 관한 연구 (A STUDY ON THE STRESS ANALYSIS OF THREE ROOT-FORM IMPLANTS WITH FNITE ELEMENT ANALYSIS)

  • 문병화;양재호
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.129-150
    • /
    • 1993
  • Since the restoration or masticatory function is the most important aim of implants, it should be substituted for the role of natural teeth and deliver the stress to the bone under the continous load during function. In natural teeth, stress distribution can be obtained through enamel, dentin and cementum and the elasticity of the periodontal ligament play a role of buffering action. In contrast, implant prosthesis has a very unique characteristics that it delvers the load directly to bone through the implant and superstructure. This fact arise the needs to evaluate the stress distribution of the implant in the mechnical aspects, which has a similar role of natural teeth but different pathway of stress. With 3 kinds of implant in prevalent use, 2 types of experimental PEA implant models were made, axisymmetric and 2-dimensional type. In axisymmetric model, the stiffness of the part including the prosthesis and implant which extrude out of bony surface could be calculated with displacement of the superstructure un er 100N vertical load and then damping effects could be determined through this stiffness. In axisymmetric FEA model, load to the bone could be deduced by evaluation the stress distribution of the designed surface under the 100N vertical force and in 2-dimensional model, 100N eccentric vertical load and 20N horizontal loda. The result are as follows. 1. In every implant, stress to the bone tends to be concenturated on the cortical bone. 2. Though the stress of the cancellous bone is larger at the apex of implants, it is less compared with cortical bone. 3. Under 20N horizontal load, stress of the left and right sides of implant shows a symmetrical pattern. But under 100N eccentric vertical load, loaded side shows much larger stress value. 4. In the 1mm interface, stress distribution among implants tend to have a similar pattern. But under 20N horizontal load apposite side of being loaded shows less stress in IMZ. 5. In the case of screw type implant, stress tends to vary along with screw shape. 6. According to the result determined with microstrain, cancellous bone id generally under the condition of overload, while cortical bone is usually within the limitation of physiologic load. 7. In the Branemark implant, maximum stress to the cortical bone is larger than any other implant except for the condition of 20N horizontal force and 0.05mm interface. 8. Damping effects of implants is maximum in IMZ.

  • PDF

인지 무선 애드혹 네트워크에서 경로 신뢰성을 고려한 효율적인 라우팅 기법 (An Efficient Routing Protocol Considering Path Reliability in Cognitive Radio Ad-hoc Networks)

  • 최준호;유상조
    • 한국통신학회논문지
    • /
    • 제39B권11호
    • /
    • pp.730-742
    • /
    • 2014
  • 인지무선 애드혹 네트워크(Cognitive Radio Ad-hoc Networks)에서 요구기반 라우팅을 수행할 경우, 경로 탐색 과정에서 발생하는 경로탐색 메시지의 브로드캐스팅은 공통 제어 채널의 과부하를 유발하고 패킷 간의 충돌을 발생시킨다. 이런 현상은 경로탐색의 오버헤드를 증가 시키며, 정확하고 신뢰성있는 경로의 탐색에 제한을 받게 된다. 이로 인하여 신뢰성있는 채널을 찾는 경로가 제한되기 때문에 경로의 생존 시간이 단축되고 경로의 안정성이 감소된다. 본 논문에서는 인지무선 ad-hoc네트워크에서 주사용자의 출현 가능성과 주변 사용자의 상황을 고려하여 패킷 충돌을 감소시키고 경로의 생존시간을 향상 시키는 라우팅 알고리즘을 제안한다. 각 노드는 주기적인 센싱을 통해 주사용자의 사용패턴을 감지하고 채널의 사용 확률과 현재 채널 상태를 알고 있다. 또한 이웃 노드와 메시지 교환을 통해 공통된 채널과 해당 채널의 품질을 파악하여 노드 사이에 링크 레벨을 부여한다. 제안된 방법에서는 링크 레벨을 이용하여 경로 탐색 과정에서 발생하는 제어 메시지의 수를 감소시킨다. 또한 링크의 생존성과 품질을 홉 카운트에 따라 가중치를 부여하여 경로를 선택함으로써 경로의 생존 시간을 향상 시킬 수 있다. 성능 평가를 통해 기존의 방법 보다 제안된 방법을 이용하여 라우팅을 수행할 경우 제어 채널의 오버헤드가 감소되고 경로의 생존시간이 증가하는 것을 확인 할 수 있다.

종합병원인력의 직무만족요인과 충성지수 (Job Satisfaction and Commitment of General Hospital Employees)

  • 한동운;엄승섭;문옥륜
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권3호
    • /
    • pp.588-608
    • /
    • 1995
  • This study was intended to enhance the level of hospital personnel management through analysing job satisfaction of hospital employees in terms of structural, personal and environmental variables. The sample of this study consist of a total of 790 persons including doctors, residents, interns, pharmacists, nurses, medical engineers, office workers and manual workers who have worked for general hospitals with 200 beds, 300 beds and 800 beds respectively. The Likert's 5 scales were used for the measurement of satisfaction. The results can be summarized as follows: 1. Structural Variables The level of satisfaction on the job itself was generally low, 2.8 in Likert's 5 scales, with the order of role ambiguity(3.87), routinization(2.6), work overload (2.45) and autonomy(2.37). Hospital employees are aware of their responsibility and they regarded their work as heavy one. The compensatory satisfaction degree was 2.5 which was also low: There were in the order stability(3.1), distributive justice(2.57), pay(2.3) and promotion(1.9). Usually hospital employees showed high degree of stability, while, their satisfaction on promotion possibility is quite low due to specially differentiated structures of hospitals. The degree of satisfaction on the internal conditions of organizational culture was relatively higher as 2.92: They were co-worker's support(3.69), supervisory support(3.15), role conflict(2.64) and welfare(2.17) in order. The satisfaction on welfare as an economic condition was the lowest. 2. Personal Variables The level of satisfaction on personal variables was 3.27 which seemed to be quite high: Contribution to the hospital(3.38), attitude on job performance(3.28) and pride as a member of the hospital(3.07). They seem to believe that their work has been helpful to the performance of hospitals. 3. Environmental Variables The degree of satisfaction on these variables was 3.07 on the average which was derived from environmental factors such as family-role conflict and community support related to hospital employees' environment. The order of satisfaction for each variable is community support(3.2) and family-role conflict(2.94). They turned out to be fairly satisfied with their job in community and yet, they wanted more spare time to spend with their family.

  • PDF

농용(農用) 디이젤 엔진 연료(燃料)로서의 에타놀 이용(利用)에 관(關)한 연구(硏究) (Technical Feasibility of Ethanol as a Fuel for Farm Diesel Engines)

  • 유관희;배영환;유수남
    • Journal of Biosystems Engineering
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1982
  • The objective of this study was to find out the technical feasibility of ethanol-diesel fuel blends as a diesel engine fuel. Fuel properties essential to the proper operation of a diesel engine were determined for blends containing several concentrations of ethanol in No. 2 diesel fuel. A single-cylinder diesel engine for a power tiller was used for the engine tests, in which load, speed and fuel consumption rate were measured. The fuels used in tests were No. 2 diesel fuel and a blend containing 10-percent ethanol and 90-percent No. 2 diesel fuel. The results of the study are summarized as follows. 1. It was not possible to blend ethanol and No. 2 diesel fuel as a homogeneous solution even though anhydrous ethanol was used. The problem of blending ethanol in No. 2 diesel fuel could be solved by adding butanol about 5% of the amount of ethanol in the blends. 2. Because ethanol had a much lower boiling point ($78.3^{\circ}C$ under atmospheric pressure) than a diesel fuel, it was necessary to store ethanol-diesel fuel blends airtight in order to prevent them from evaporation losses of ethanol. 3. The addition of ethanol to No. 2 diesel fuel lowered the fuel viscosity and the cetane rating, but a blend of 10% ethanol and 90% diesel fuel had a viscosity and a cetane rating well above the KS minimum values for No. 2 diesel fuel. 4. At the rated speed, the specific fuel consumption of No.2 diesel fuel was lower than that of the 10% ethanol blend for the almost entire range of load. However, under the overload condition the specific fuel consumption was lower for the 10% ethanol blend. 5. Under the variable-speed full-load tests, both fuels produced approximately the same torque and power. At the speeds of 1600rpm or below, the specific fuel consumption of No. 2 diesel fuel was lower than that of the 10% ethanol blend. At the speeds of 1600rpm or above, however, the specific fuel consumption was lower for the 10% ethanol blend. 6. At the ambient temperature above $15^{\circ}C$, the use of the 10% ethanol blend in the engine created a vapor lock in the fuel injection pump and stalled the engine. The vapor locking problem was overcome by chilling the surroundings of the fuel injection pump and the cylinder head with water.

  • PDF

오염된 임프란트 표면의 해독 방법에 따른 내독소 제거 효과에 관한 연구 (The Endotoxin Assay of Contaminated Titanium Implants following Various Techniques of Detoxification)

  • 박중희;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.71-81
    • /
    • 2004
  • Peri-implantitis could be the result of biomechanical and occlusal overload as well as microbiologic invasion. The dental implant may be more susceptible to dental plaque than the natural tooth, as the predictability of a stable soft tissue attachment complex has not yet been confirmed. With the development of peri-implantitis, the implant surface would be exposed to the oral environment and becomes coated with bacteria. The objective of therapy for this condition is to regain integration of the implant with bone. Since fibroblast adherence to surfaces is impeded by endotoxin, it would seem that decontamination would be desirable to obtain maximum osseointegration. The purpose of this study was to determine whether various chemotherapeutic and mechanical treatments(distilled water, air-powder abrasive, hypersaturated citric acid, tetracycline) can detoxify contaminated titanium implant surface by means of kinetic LAL test. Experimental rough surface titanium disks were fabricated. All of them were divided into two groups(A.a group and P.g group) and each contaminated by A. actinomycetemcomitans and P. gingivalis suspension. Contaminated disks were treated with distilled water, air-powder abrasive, citric acid and tetracycline, and then all disks were placed into LPS-free water for elution. The results were as follows : 1. In A.a group, LPS elute level of all test groups were significantly lower than control group(p<0.05). 2. In A.a group, LPS elute level of test 2, test 3 and test4 groups were significantly lower than that of control group(p<0.05). But, among the test 2, test 3, test4 groups, the significant differences were not detected. 3. In P.g group, LPS elute level of test 2, test 3 and test 4 groups were lower than that of control group(p<0.05). But, among the test groups, the significant differences were not detected. From the result of this study, it would be concluded that air-powder abrasive, hypersaturated citric acid and tetracycline treatments may be effective at reducing endotoxin level on rough titanium implant surfaces, and can be clinically used. But the treatments in peri-implantitis differentially impact osseointegration making one method clinically superior. To gain this knowledges, further molecular biologic and histopathologic studies should be developed.

산업체영양사의 영양교육 인식단계별 직장인 영양교육 현황 (Nutrition Education Status in Industrial Workers with Meal Service by Dietitian Recognized Stage of Nutrition Education)

  • 오희정;이승교;원향례
    • 한국지역사회생활과학회지
    • /
    • 제18권2호
    • /
    • pp.323-334
    • /
    • 2007
  • This study was made to analyze the condition and the needs of nutrition education considering the different stage of nutrition education recognized by the dietitian in industrial area. 165 female dietitian were surveyed by questionnaire and they were divided into 4 groups according to the different recognition stages of nutrition education: Pre-contemplation(PC) 4.8%, Contemplation(CO) 46.7%, Preparation(PR) 22.4%, Action & Maintenance phase(AM) 26.1%. For statistical analysis, SAS(Ver.8.1. for Window) was used to find out the distribution related with nutrition education and to calculate the scores of mean and standard deviation. General characteristics of the subjects are about 20 years old(71.5%), single(69.7%), careers over 5 years(40%) and university graduates(73.9%). The number of meals(p<0.05) and the employment status(p<0.05) were significantly different according to the recognized stage of nutrition education. The practice of nutrition education was different depending on the dietitian in the industry. Many of the factory dietitian were in pre-contemplation stage(87.5%), however, those in the office and service area were more in Action & Maintenance stage(27.9%). In the industrial area, just 26.1% of dietitian operated the nutrition education and most did not due to the work overload and insufficient support of staff(73.3%). The frequency for the most effective nutrition education was once a month(61.2%). The contents for desirable nutrition education were in the order of 'eating habits'(36.1%), 'relation with the daily life'(23.5%), 'food hygiene' (21.7%), 'nutrition knowledge'(9.7%), and 'disease prevention'(9%). In operating nutrition education, dietitian had concerns about 'insufficient support of staff', 'shortage of teaching materials' and 'lack of time'. And, the dietitian who were with lower recognition stage of nutrition education(P<0.05) concerned more about the insufficient educational contents. In conclusion, dietitian in the industry highly recognized the need of nutrition education, but it was so difficult to practice. For more programs and various materials should be developed, and the staff's perception, the view of dietitian and the meal service should be changed, too. For the health improvement of industrial workers, it would be necessary to proclaim the importance of nutrition education nationwide.

  • PDF

이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가 (The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray)

  • 이해정;김호성;김은혜
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

에폭시 박막 절연형 버스웨이 시스템의 장기 수명 및 신뢰성 평가에 관한 연구 (Study on the Estimation of Long Life Cycle and Reliability Tests for Epoxy Insulation Busway System)

  • 장동욱;박성희;이강원
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.261-268
    • /
    • 2018
  • 전력수요와 부하용량이 증가 되어감에 따라 부하에 전력공급을 위한 간선으로서의 케이블은 설치 시간의 과다와 공간의 제약으로 사용이 제한적이다. 이런 문제를 해결하기 위한 간선 시스템으로 대전류를 효율적으로 공급해 줄 수 있는 버스웨이 시스템의 사용이 증가되고 있으나, 신뢰성의 검증을 위한 시험평가 방법과 그에 대한 결과 제시가 부족한 실정이다. 본 논문에서는 에폭시를 주절연으로 하는 버스웨이 시스템의 신뢰성 검증을 위해서 IEC 61439-6에서 제시된 시험항목이외에 장기 사용성과 신뢰성을 평가할 수 있는 시험항목을 선정하였다. 열 및 전기적 스트레스를 동시에 인가하여 최대한 실사용 상태를 반영한 복합가속열화시험을 실시하였으며, 50년 수명 조건을 충족하도록 열화 조건을 선정하여 버스웨이 시스템의 절연성능 확인시험을 통해 수명을 만족함을 확인하였다. 또한, 버스웨이가 설치되는 온도, 습도 및 부하전류 사용 환경에 대한 적합성 확인에 대한 신뢰성 평가 시험항목으로서 열적 과전류 시험, 침수시험, 냉충격시험, 온도 사이클 시험을 선정하여 실시하였으며, 확인 시험을 통해 시험 전후의 특성 변화와 이상 유무를 검토하였다. 이 결과들로부터 에폭시 절연형 버스웨이 시스템의 평가항목으로서 본 논문에서 제시한 시험항목이 적절하고, 그에 대한 제품의 성능도 우수함을 확인하였다.