• Title/Summary/Keyword: Overlapping Ratio

Search Result 152, Processing Time 0.024 seconds

A study on patients transferred to emergency medical center of university hospital -About reexamination status of patients transferred - (3차 의료기관 응급의료센터로 전원되는 환자에 대한 조사연구 - 중복 재검사에 관한 조사 -)

  • Yoou, Soon Kyu
    • The Korean Journal of Emergency Medical Services
    • /
    • v.3 no.1
    • /
    • pp.20-32
    • /
    • 1999
  • The purpose of this retrospective research of 603 patients who were transferred to the emergency medical center of university hospital from 1 Jan, 1998 to 31 Jan, 1998 was making of basic data for emergency medical transfer system improvement countermeasure and the point at issue of overlapping reexamination ststus of patients transfered to emergency medical center of university hospital from 1,2 level hospital. The data analysis was done by SPSS, t-test, ANOVA, Pearson correlation. The results were as follows: 1. Male to female ratio was 1.7:1 and peak age group was patients over forties and under nine years of age(70.5%) 2. Traumatic patients were 17.8%, motor vehicle accident patients were 16.7% and Non-traumatic patients were 65.3%. Transferring hospital was divided into 2groups: primary hospital, secondary hospital. The majority was secondary hospital(73.3%). The result of symptom severity classification of patients transferred to 3rd emergency medical center was urgent patients 32.5%, emergency patients 33.58%, non-emergency patients 34.0% 3. Most highest score items amoung overlapping reexamination of patients transfered to emergency medical center of university hospital from 1,2 level hospital were CBC test, simple X-ray (0.93점), CBC test(0.97점), urin test(0.88점), chemistry test(0.94점), simple X-ray(0.98점), CT(0.42점), EKG(0.89점) amoung overlapping reexamination of motor vehicle accident patients were more higher reexamination score than traumatic patients and non-traumatic patients 4. CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.001), CT(P<0.01), EKG(P<0.001) amoung overlapping reexamination of patients in 2 level hospital were more higher reexamination score than 1 level hospital patients 5. About symptom severity classification of patients transferred to 3rd emergency medical center, CBC test(P<0.001), urin test(P<0.001), chemistry test(P<0.001), simple X-ray(P<0.01), CT(P<0.001), EKG(P<0.001) amoung overlapping reexamination items in urgent patients were more higher reexamination score than other patients 6. Influencing variation for overlapping reexamination in hospital was CBC test(P<0.001), CT (P<0.001), MRI (P<0.05).

  • PDF

Void Closing Conditions of Large Ingot by Path Schedules (대형 잉곳의 기공압착 효과 향상을 위한 폐쇄조건 연구)

  • Choi, I.J.;Choi, H.J.;Kim, D.W.;Choi, S.;Lim, S.J.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.480-485
    • /
    • 2010
  • In this work, the closing behavior of cylindrical-shaped voids was experimentally investigated according to various parameters such as reduction ratio in height, initial void size and billet rotation during hot open die forging process. The reduction ratio in height, number of path, and billet rotation were chosen as key process parameters which influence the void closing behavior including the change of void shape and size. On the other hand, values of die overlapping and die width ratio were set to be constant. Void closing behavior was estimated by microscopic observation. Based on the observations, it was confirmed that application of billet rotation is more efficient to eliminate the void with less reduction ratio in height. The experimental results obtained from this study could be helpful to establish the optimum path schedule of open die forging process.

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

The Contribution of Spindle Parts to Static, Dynamic Stiffness and Design Improvement (공작기계 주축의 요소별 정동적 강성기여율 및 개선에 관한 연구)

  • 이찬홍;박천홍;이후상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.985-988
    • /
    • 2002
  • The Spindle-]fearing System is very important unit for geometrical accuracy in machine tools. To improve effectively the weak point of spindle system, it is necessary that the contribution ratio of spindle core parts to static and dynamic stiffness is clarified. In this paper, static contribution ratio of core parts is calculated by overlapping static deformation of basic spindle design with one flexible parts. The dynamic contribution ratio for natural frequency and dynamic deformation at spindle end is obtained by calculating correlation between original and basic spindle deformation, by curve fitting with regressive method. It is proved the validity of estimation result is correct.

  • PDF

BUILDABILITY OF MORTAR FEEDSTOCK IN MATERIAL EXTRUSION ADDITIVE MANUFACTURING

  • JINSOO PARK;HOJAE LEE;HANSHIN CHOI
    • Archives of Metallurgy and Materials
    • /
    • v.65 no.3
    • /
    • pp.1069-1072
    • /
    • 2020
  • Mortar feedstock is extruded to form bead and it is selectively placed line by line in the material extrusion additive manufacturing. With respects to part building process healthiness, load-supporting ability of overlaid beads is emphasized as buildability. Buildability is primarily dependent on thixotropic properties of feedstock and vertical overlapping schedule. In the present study, water-to-binder (w/b) ratio was chosen as material aspect to assess buildability. Uneven bead shape evolution and premature failure were highlighted owing to low yield stress of high w/b ratio feedstock. Feedstock with optimum w/b ratio showed good buildability even at the interval time of 19 sec.

Diagnostic Accuracy of Lactate Dehydrogenase/Adenosine Deaminase Ratio in Differentiating Tuberculous and Parapneumonic Effusions: A Systematic Review

  • Larry Ellee Nyanti;Muhammad Aklil Abd Rahim;Nai-Chien Huan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.1
    • /
    • pp.91-99
    • /
    • 2024
  • Background: Tuberculous pleural effusion (TPE) and parapneumonic effusion (PPE) are often difficult to differentiate owing to the overlapping clinical features. Observational studies demonstrate that the ratio of lactate dehydrogenase to adenosine deaminase (LDH/ADA) is lower in TPE compared to PPE, but integrated analysis is warranted. Methods: We conducted a systematic review to evaluate the diagnostic accuracy of the LDH/ADA ratio in differentiating TPE and PPE. We explored the PubMed and Scopus databases for studies evaluating the LDH/ADA ratio in differentiating TPE and PPE. Results: From a yield of 110 studies, five were included for systematic review. The cutoff value for the LDH/ADA ratio in TPE ranged from <14.2 to <25. The studies demonstrated high heterogeneity, precluding meta-analysis. Quality Assessment of Diagnostic Accuracy Studies Tool 2 assessment revealed a high risk of bias in terms of patient selection and index test. Conclusion: LDH/ADA ratio is a potentially useful parameter to differentiate between TPE and PPE. Based on the limited data, we recommend an LDH/ADA ratio cutoff value of <15 in differentiating TPE and PPE. However, more rigorous studies are needed to further validate this recommendation.

A DOMAIN DECOMPOSITION PRECONDITIONER FOR STEADY GROUNDWATER FLOW IN POROUS MEDIA

  • Ghahreman, N.;Kerayechian, A.
    • Journal of applied mathematics & informatics
    • /
    • v.7 no.3
    • /
    • pp.773-785
    • /
    • 2000
  • In this paper an algorithm is presented based on the additive Schwarz method for steady groundwater flow in a porous medium. The subproblems in the algorithm correspond to the problem on a coarse grid and some overlapping subdomains. It will be shown that the rate of convergence is independent of the mesh parameters and discontinuities of the coefficients, and depends on the overlap ratio.

Generation of Electromagnetic Energy in a Refractory Metal Thermionic Diode (내화금속 다이오드에서 전자기에너지 발전에 관한 연구)

  • Lee, Deuk-Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.7
    • /
    • pp.823-828
    • /
    • 1992
  • A thermionic energy converter test station is constructed for the study of electromagnetic energy generation. Of particular interest is the frequency variations due to changes in the interelectrode gap, the electrode temperature, and the cesium vapor pressure. It is found experimentally that the most intense ratio-frequency(rf) oscillations occur at two non-overlapping regions.

  • PDF

Influence of Inadequate Rebar Lap Position on Crack of Underground Box Slab (철근 겹침이음 위치 부적정이 지하박스 슬래브 균열 발생에 미치는 영향)

  • Choi, Jung-Youl;Jang, In-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.685-692
    • /
    • 2020
  • In this study, the experimental and analytical study were performed on the location of longitudinal cracks in the middle of underground box structures. The location where the longitudinal cracking occurred was investigated that the overlapping joint of the rebar and the section of maximum tensile stress generated. Using the finite element analysis, the strength reduction ratio of the rebar was estimated by lack of overlap joint length. As the result of adequacy investigation for the length of the overlap joint presented in the design criteria, it was analytically proved that the lack of the overlap joint length could be cause the decreasing cross-sectional force and concrete cracking. As the result of this study, the adequacy of the overlapping criterion in the current design criteria was confirmed based on the finite element analysis and actual field case. In the case of overlapping joints installed in inappropriate position, it was considered that a long term crack control would be need to ensure the sufficient safety factor for the designed cross-sectional force.

A Channel Allocation and Data Delivery Scheme Considering Channel Overlapping in Wireless Tactical Networks (군 전술망의 무선 이동 통신 체계의 통신 범위 중첩을 고려한 채널 할당 기법과 데이터 전달 기법)

  • Shin, Hyun-Sup;Chae, Sung-Yoon;Kang, Kyung-Ran;Cho, Young-Jong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.501-508
    • /
    • 2011
  • In this paper, we propose a channel allocation algorithm of MSAP(Mobile Subscriber Access Point) and data delivery scheme exploiting the symbol level network coding. The network is comprised of TS(Tactical Switch) as a backbone node, MSAPs, and TMFTs(Tactical Multi-Function Terminal). The TS performs the channel allocation considering the communication range overlapping between the neighboring MSAPs and applies the symbol level network coding, if necessary, depending on the position of the TMFTs. Assuming the number of available antennas of TMFT and MSAP will be extended to two from one, we propose two schemes: single mode and dual mode. Through the simulation, we show that the proposed delivery scheme provides higher delivery ratio and lower delivery delay compared with the legacy store-and-forward scheme.