• Title/Summary/Keyword: Overlap Angle

Search Result 57, Processing Time 0.032 seconds

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

A study on the sled test methods for IIHS small overlap performance development (IIHS small overlap 성능개발을 위한 대차 시험 방법 연구)

  • Oh, Hyungjooon;Kim, Seungki;Kim, Sungwon;Lim, Kyungho
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Small overlap crash caused fatal injury in real-world crash. IIHS(Insurance Institute for Highway Safety) proposed the small overlap test. The objective of this study is to analyze dummy injury criteria and dummy excursion on the sled reinforced body angle. Result of the comparisons of dummy injury criteria of a head, neck, and chest was best correlation between sled and vehicle test on base $angle+3^{\circ}$. However, lower extremity was not correlation because sled test could not copy of intrusion. There were a correlation between dummy movement and sled reinforced body angle. Sled reinforced body angle affects the lateral direction of excursion more than longitudinal excursion.

A Study on the Attrition of Maxillary Canine in Korea (상악 견치의 교모에 관한 연구)

  • Lim, Byung-Chul
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.121-130
    • /
    • 1997
  • This study was aimed to help the construction of naturally dental prosthesis by investigation of the factors affecting on the attrition position and attrition angle of maxillary canines. Therefore 163 complete cast of maxillary and mandibular extracted from the student of K. college were subjected for this study, and result through the study are as follows. 1. None attrite rate of the maxillary canine was 7%, of examined teeth. 2. Throughout mesiodistal attrition of 1) Throughout mesiodistal attrition area of the maxillary canines showed that mesial area and mid area of cusp was more frequence in attrition than distal area of it. 2) Sex, dental arch type, vertical overlap, horizontal overlap, did not affect significantly to throughtout mesiodistal attrition statistically 3. Througout labiolingual attrition area 1) Throughout labiolingual attrition area of the maxillary canines showed that attrition of the from lingual to labioncisal edge was more frequence than it of linguoincisal edge 2) It showed that attrition of the from lingual to labioincisal edge was more frequence when the length of horizontal overlap is shorter, by horizontal overlap 3) The attrition of the from lingual to labioincisal edge in maxillary left canines showed that male was more frequence in attrition than female. 4) Dental arch type, vertical overlap, did not affect signioficantly to labiolingual attrition, statistically. 4. Attrition angle 1) It showed that average attrition angle of the maxillary right canines were $19{\pm}11.02$ dagree, and it of left canines were $18{\pm}11.83$ degree. 2) It showed that famale have a bigger attrition angle than male, by sex. 3) It showed that attrition angle was bigger when the length of horizontal ovelap is bigger, by horizontal overlap.

  • PDF

A Study on the Attrition of Maxillary Lateral Incisors in Korea (상악 측절치의 교모에 관한 연구)

  • Lim, Byung-Chul
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.117-127
    • /
    • 1996
  • This study was aimed to help the construction of esthetic dental prosthesis by investigation of the factors affecting on the atterition position and attrition angle of maxillary lateral incisors. Therefore 197 complete cast of maxillary and mandibualar extracted form the student of K. college were subjected for this study, and result throught the study are as follows. 1. None attrite rate of the maxiilary right lateral incisors was about 16.2% and that of the maxillary left lateral incisors was about 32.4% of examined teeth. 2. Throught mesiodistal attrition area 1) It showed that right lateral incisors was the most frequence in attrition of mesial area of incisal edge, and left lateral incisors was the most frequence in attrition of mesial and mid area of incisal edge. 2) It showed that square type arch was more frequence in attrition of all incisal edge, and ovoid type arch was more frequence in the attrition of mid area of incisal edge, and ovoid type arch was more frequence in the attrition of mid area of incisal edge, and taper type arch was more frequence in the attrition of mesial area of incisal edge than it of average frequence of right lateral incisors, by dental arch type. 3) It showed that square type arch was more frequence in the attrition of all area and mid area of incisal edge, and ovoid type arch was more frequence in the attrition of mid area of incisal edge, and taper type arch was more frequence in the attrition of mesial and distal area of incisal edge than it of average frequence of left lateral incisal, by dental arch type. 4) Sex, vertical overlap, horizontal overlap, incisal guide angle, did not affect significantly to throughout mesiodistal attrition, statistically 3. Throughout labiolingual attrition quantity. 1) It showed that throughout labiolingual attrition quantity was more attrition in order of taper type arch < ovoid type arch < square type arch, by dental arch type. 2) It showed that throughout labiolingual attrition qauntity was more attrition when the length of horizontal overlap is shorter than it of other, by horizontal overlap. 3) Throughout labiolingual attrition quantity of right lateral incisors showed that male was more attrition than it of female. 4) Vertical overlap, incisal guide angle, sex on left lateral incisors did not affect significantly to throughout labiolingual attrition, statistically. 4. Attrition angle 1) It showed that average attrition anlge of right lateral incisors were $30{\pm}13.02$ degree, and it of left lateral incisors were $26{\pm}13.37$ degree. 2) It showed that taper type arch have a bigger attrition angle than it of average of lateral incisors, and square tape arch have a smaller attrition angle than it of average of lateral incisors, by dental arch type. 3) It showed that horizontal overlap of 2.1mm above have a bigger attrition angle than it of average, by horizontal overlap. 4) It showed that female have a bigger attrition angle it of male, by sex.

  • PDF

Decision on the Optimal Photographing Angle and Overlapping Ratio of Non-metric Cameras for Development of Automatic Image Stitching System (영상집성 자동화 시스템 개발을 위한 비측량용 카메라의 최적 촬영각 및 중복도 결정)

  • Kim, Dae Sung;Shin, Sang Chul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.117-123
    • /
    • 2013
  • This study focuses on the determination of optimal photographing angle and overlapping ratio for automatic image stitching system using a non-metric camera module with motorized head. Photographing overlap was calculated considering the angle of view on different kinds of lenses and moving angle of motorized head per each option, and optimal photographing angle and overlapping ratio could be determined through the experimental result using the operating time, data volume and performance of image stitching. Through this experiment, we could find that it was effective to take a picture with $36^{\circ}$ of interval(33.82% of overlap) in vertical direction and $24^{\circ}$ or $30^{\circ}$ of interval(36.51% or 20.63% of overlap) in horizontal direction using 35mm lens for automatic image stitching system.

An Experimental Study on Overlap Control at Plate Rolling (후판압연에서의 오버랩 제어에 대한 실험적 연구)

  • 천명식;한석영;이준정;김종근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.376-385
    • /
    • 1991
  • For manufacturing trimming-free plates which have rectangular shaped edges and straight edges in as-rolled state, it is necessary to investigate rolling characteristics of overlap, bulge and width deviation etc. in a standardized plate rolling process. The present wok is for preventing edge overlap as the first approach to develop trimming-free plate rolling technique. An experimental study on overlap control was done with plasticine material in order to examine influence factors and find a control method by use of a laboratory mill scaled down to one tenth of actual production mill. It was found that edge overlapping was increased with the increase of slab thickness and of broadside rolling ratio, but decreased with the increase of chamfered amount on slab edges. In the simulated rolling experiment with edge chamfered slabs of various chamfered angles, the chamfered angle of 60.deg. was the most effective one for reducing overlapping irrespective of slab thickness and of broadside rolling ratio.

Study of Suitable Angle of Tibia-Foot and X-ray Tube for Navicular in Foot X-ray Examination (족부 X선 검사에서 주상골 관찰에 용이한 Tibia-Foot angle과 X-ray tube 각도에 대한 연구)

  • Moon, Joo-Wan;Han, Jae-Bok;Choi, Nam-Gil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • The purpose of this study was to determine suitable angle of Tibia-foot and the X-ray tube for scaphoid in foot X-ray examination. A total of twenty patients(mean age $32.12{\pm}years)$ are participated in this study. In the positions of Foot AP, internal and external oblique, tibia-foot angle was defined as $90^{\circ}$ and $135^{\circ}$, and x-ray tube angle was defined as $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$ and $20^{\circ}$ respectively. The image quality was evaluated with blind test yielding scores ranging from 0 to 5 by the evaluation team consisted of 2 radiogical technologists, 2 radiologists, and 2 orthopedic surgeons. In case of Foot AP position, the degree of overlap between cuneiform and navicular was 3% and the blind test result was 4.89 at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle. When the tibia-foot angle is $135^{\circ}$, the degree of overlap was 5%, also the blind test result was 4.30 at $15^{\circ}$ X-ray tube angle. The degree of overlap and blind test result were 30% and 3.75 respectively at $0^{\circ}$ X-ray tube angle. In case of internal oblique position, at tibia-foot angle of $90^{\circ}$ and $0^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test result was 4.70. The 5% overlapping and highest score as 4.55 were obtained on tibia-foot angle of $135^{\circ}$ and $0^{\circ}$ X-ray tube angle. In case of external oblique position, at tibia-foot angle of $90^{\circ}$ and $15^{\circ}$ X-ray tube angle, the degree of overlap was 4% and the blind test score was 4.85. The 5% overlapping and highest score as 4.75 were obtained on tibia-foot angle of $135^{\circ}$ and $15^{\circ}$ X-ray tube angle. In conclusion, we confirmed suitable angle of tibia-foot and X-ray tube for scaph46oid in foot X-ray examination in this study. These findings will be helpful for us to reading for navicular fracture.

Method of Setting Nozzle Intervals at the Finishing Scale Breaker

  • Park, Jong-Wook;Kim, Sung-Cho;Park, Jin-Won
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.870-878
    • /
    • 2003
  • The scale is removed from the strip by high pressure hydraulic descaling at the FSB (Finishing Scale Breaker). Recently, the spray height of nozzle has a trend to be shorter for the purpose of increasing the impact pressure by the high pressure water jet. Here, the nozzle intervals should be decided after considering the impact pressure and the temperature distribution on the strip. In other words, the minimum of impact pressure at the overlap of spray influences the surface grade of the strip due to scale and the overlap distance of the spray affects the temperature variation in the direction of the width of strip. In the present study, the impact pressure of the high pressure water jet is measured by the hydraulic descaling system and calculated with regard to the lead angle of 15$^{\circ}$ and the offset angle of 15$^{\circ}$, and then the temperature distribution and the temperature variation are calculated at the overlap distances of 0 mm, 10 mm, 20 mm, and 30 mm, respectively. The method of setting nozzle intervals is shown by utilizing these results.

Characterization of Silver Inkjet Overlap-printing through Cohesion and Adhesion

  • Lee, Sang-Ho;Cho, Young-June
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.91-96
    • /
    • 2012
  • We introduce an understanding of silver (Ag) inkjet overlap-printing characteristics from the viewpoints of cohesion between ink droplets and adhesion between an ink droplet and a surface. The printing characteristics were closely monitored by changing the surface energy to elucidate the effect of adhesion and cohesion on printing instability, such as droplet merging and line bulging. The surface energy of the substrate was changed through the hydrophilization of a hydrophobic fluorocarbon-coated surface. The surface energy and ink wettability of the prepared surfaces were characterized using sessile drop contact angle analysis, and printing instability was observed using an optical microscope after drop-on-demand inkjet printing with a 50% overlap in diameter of deposited singlet patterns. We found that the surface energy is not an appropriate indicator based on the experimental results of Ag ink printing on a hydrofluoric-treated silicon surface. The analytical approach using adhesion and cohesion was helpful in understanding the instability of the inkjet overlap-printing, as adhesion and cohesion represent the direct interfacial relationship between the Ag inks used and the substrate.

Change of Radiologic Index of Foot according to Radiation Projection Angle: A Study Using Phantom Foot (방사선 투과 각도에 따른 족부 방사선 지표의 변화: Phantom Foot을 이용한 연구)

  • Kim, Eo Jin;Seo, Sang Gyo;Lee, Dong Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Purpose: The purpose of this study is to analyze the measurement differences of simple radiographs according to radiation projection angle using a phantom and to propose methods for objective analysis of simple radiographs. Materials and Methods: We took simple radiographs with different projection angles using a C-arm image intensifier and measured five parameters of the foot on the simple radiographic images. Five parameters include lateral tibiocalcaneal angle, lateral talocalcaneal angle, naviculocuboid overlap, lateral talo-first metatarsal angle, and lateral calcaneo-first metatarsal angle. Intraobserver and interobserver reliability were verified, and then intraclass correlations of parameters were analyzed. Results: Radiographic parameters of the foot showed high intraobserver and interobserver reliability. Lateral tibiocalcaneal angle has a strong negative linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral talocalcaneal angle has a moderate positive linear relationship with rotation and a strong positive linear relationship with tilt. Naviculocuboid overlap has a strong positive linear relationship with rotation and a moderate positive linear relationship with tilt. Lateral talo-first metatarsal angle does not have a linear relationship with rotation and a moderate negative linear relationship with tilt. Lateral calcaneo-first metatarsal angle has a moderate positive linear relationship with rotation and tilt. Conclusion: More precise evaluation of the foot with a simple radiograph can be performed by understanding the changes of radiographic parameters according to radiation projection angle.