• Title/Summary/Keyword: Overheating at electrical connections

Search Result 3, Processing Time 0.017 seconds

Analysis of a Fire Case Caused by Heat Generation due to Cu2O Breeding (아산화동증식 발열에 의한 화재 사례의 분석)

  • Park, Jin-Young;Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.54-63
    • /
    • 2020
  • Although fires caused by heat generation due to Cu2O breeding in wire connections are well-known among fire investigators, there are few papers on the analysis and introduction of fire cases by heat generation due to Cu2O breeding. This study analyzed fire statistics caused by heat generation in electrical connections and the phenomena and features of heat generation due to Cu2O breeding. Then, a fire which occurred in the wire connection in a university lab by heat generation due to Cu2O breeding was analyzed in more detail. This fire case could reach a conclusion that heat generation due to Cu2O breeding caused a fire in the wire connection through the fire pattern investigation of fire origin, the visual investigation of wire connection, 3D CT, power-on-test, and stereoscopic microscopy, SEM and EDS analysis.

Studies on Generation and Detection of Discharge Signals in a Low-voltage Outlet (저압용 전열수구에서 방전 신호의 발생과 검출에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Cho, Young-Jin;Hwang, Don-Ha
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.498-502
    • /
    • 2005
  • The objectives of this paper are to provide information on the characteristics of the discharge signals in a low-voltage indoor outlet. Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. We have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using aged outlets. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600kHz - 1.5MHz in incomplete connections and at 210H7z - 8MHz in deteriorations of the outlet.

Generation and Detection of Discharge Signals in Deteriorated (열화된 저압용 콘센트에서 방전신호의 발생과 검출)

  • Song, Jae-Yong;Seo, Hwang-Dong;Moon, Seung-Bo;Kil, Gyung-Suk;Cho, Young-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.200-203
    • /
    • 2005
  • Most of electrical fires are caused by short circuits, overheating of wires, deterioration and incomplete connection of wiring devices. The last two cases are predictable before the occurrence of fire because of its slow progress. In this paper, we have simulated the discharge signals caused by the deterioration and incomplete connection of wiring devices using an aged concent to provide information on the characteristics of discharge signals. From the experimental data, we could characterize the frequency spectrums of the discharge signals depending on the cases. The higher frequency components of the signal are attenuated by the capacitance and inductance of power lines as the measuring point is getting away from the discharges. Main frequency components of the discharge signal are existent at 600 kHz - 1.5 MHz in incomplete connections and at 210 kHz - 8 Mhz in deteriorations of the concent.

  • PDF