• Title/Summary/Keyword: Overhead transmission lines

Search Result 179, Processing Time 0.027 seconds

송전선로 주변과 비주변 초등학생을 대상으로 극저주파 자기장 노출과 뇨중 멜라토닌 분비량간의 상관성 연구 (Relationship Between Urinary Melatonin Levels and Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Living Nearby and Away from Overhead Transmission Power Line)

  • 조용성;김윤신;이종태;홍승철;장성기
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.191-206
    • /
    • 2004
  • The present study investigated the hypothesis that a extremely low frequency magnetic field partially suppresses the synthesis of melatonin in a group of 28 primary schoolchildren living nearby and 60 primary schoolchildren aged 12 years living far away from overhead transmission power lines from December 2003 to April 2004 in Seoul, Korea. The mean personal exposure levels of the primary schoolchildren living nearby overhead transmission power line were 0.37 ${\mu}$T, whereas the value for the primary schoolchildren living away from overhead transmission power line 0.05 mT. From simple analyses, the mean melatonin levels in the primary schoolchildren living nearby were lower than away from overhead transmission power line, but not statistically significant differences in the levels of the melatonin (p=0.2421), whereas the statistically significant differences in the levels of the melatonin related to the distance from residence to power line less and more than 100 m by cut-off point (p=0.0139). In multiple linear regression analyses, distance from residence to power line (p=0.0146) and dietary habit about burned meat (p=0.0170) proved to be significant risk factors in the mean nocturnal melatonin levels in the primary schoolchildren. In conclusion, these results demonstrate that urinary levels of nocturnal melatonin are not altered in primary schoolchildren exposed to extremely low frequency magnetic field(ELF-MF) at overhead transmission power line.

화염에 노출된 가공송전선의 기계적.재료적 특성 검토 (Mechanical characteristic of overhead transmission lines by forest fires)

  • 강지원;장태인;김북규;박창기;방항권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.339-341
    • /
    • 2002
  • The remaining life of ACSR exposed to the atmosphere for a long period may rely on deterioration caused by environmental indices such as atmospheric corrosion, galvanic corrosion, crevice corrosion and fatigue corrosion. One of reduction of useful life in overhead transmission lines built on the ridge of mountain is often caused by forest fires. This paper deals with investigation of strength deterioration performance of ACSR due to fires through several testing and analyzing data for both tension load and material analysis. Test samples are ACSR $480[mm^2]$ conductors, which are artificially fired to regular durations. As a result, it can be verified that tension load of ACSR are reduced by increasing fro duration. Hence, it is obvious that ACSR due to forest fires may lead to mechanical deterioration.

  • PDF

345kV 가공선로에서 진동발생 다발 소경간에 대한 진동저감 대책(II) (A study on measures against subspan oscillation by twin spacers in 345kV overhead transmission lines(II))

  • 이형권;한형주;박창기;최웅규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.200-202
    • /
    • 2008
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 34sky real lines, and we got a good effect for controling subspan oscillations.

  • PDF

Economic Analysis of Power Transmission Lines using Interval Mathematics

  • Teegala, Srinivasa Kishore;Singal, Sunil Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1471-1479
    • /
    • 2015
  • A major portion of the capital costs in the present day power transmission systems are due to the cost of equipment and construction process. Transmission utilities in the recent years are drawing greater attention towards performing life cycle costing studies for cost management and decision making. However, the data involved in these studies are highly uncertain and the effect of these uncertainties cannot be directly included in the study process, resulting in inaccurate solutions. Interval mathematics provides a method for including these uncertainties throughout the cost analysis and provides final solution range in the form of intervals. In this regard, it is essential and extremely important that significant research has to be carried out in understanding the principles of life cycle costing methodology and its applicability to cost analysis of transmission lines along with uncertainties involved in the cost assessment process. In this paper, economic analysis of power transmission lines using interval mathematics has been studied. Life cycle costing studies are performed using net present value analysis on a range transmission lines used in India and the results are analyzed. A cost break even analysis considering right of way costs was carried out to determine the point of economy indifference.

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발 (The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line)

  • 주문노;양광호;이동일;신구용;임재섭
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

고온초전도 전력케이블 설계 및 계통적용 (Conceptual Design and Application of HTS Power Transmission Cable)

  • 조전욱;성기철;김해종;이언용;류강식;박종수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.129-133
    • /
    • 1999
  • In recent years, there is a growing needs for large capacity underground power transmission lines with the increasing demand of electric power in the urban area, where various environmental limitations are imposed on the overhead transmission lines. But it is difficult to get the space for the underground power transmission cables because of complicated distributions of underground public facilties such as subway, water pipes, gas etc. As the superconducting power cables have the large power transmission capacity, the high power transmission capacity, the high power transmission density, and low loss characteristics in comparison with a conventional cable, it would be a solution to meet the increased power demand. In this paper, the results of the conceptual design and analysis of power system of HTS power transmission cable is described.

  • PDF

초고압 송전선로에 의한 TV Ghost 장해 발생 특성 (Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line)

  • 주문노;양광호;이동일;신구용
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

도로터널 조명시설의 설계기준

  • 지철근;이진우
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권1호
    • /
    • pp.14-23
    • /
    • 1997
  • 본 논문에서는 154[㎸] 가공송전손로의 주변에서 발생하는 극저주파 영역(ELF)의 전장의 측정 분석한 결과에 대해서 기술하였다. 상용주파수와 같은 저주파 성분의 검출을 위한 3차원 평행평판형 전장센서를 제작하였으며, IEEE에서 추천하는 실험방법을 적용하여 교정실험을 수행한 바 제작된 전계측정장치의 주파수 대역은 7[Hz]에서 2.7[MHz]이고, 응답 감도는 0.094[mV/V/m]이었다. 154[㎸] 2회선 가공송전선로 아래에서 전장의 실측 실험을 수행하고, 그 결과를 분석하였다, 가공송전선 아래에서의 전장의 분포는 주변의 금속 물체 때문에 비대칭 형상을 나타내었으며 그리고 최대 전계의 세기는 3[㎸/m]이하이었다. 본 연구에서는 측정 결과는 관련 여러 국제기관의 제한 권고치를 만족시키고 있다.

  • PDF

기상예보시스템을 이용한 가공송전선의 단기간 동적송전용량 예측 (Short-Term Dynamic Line Rating Prediction in Overhead Transmission Lines Using Weather Forecast System)

  • 김성덕;이승수;장태인;장지원;이동일
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.158-169
    • /
    • 2004
  • 본 논문에서는 실시간 기상예보데이터를 사용하여 가공송전선의 단시간 송전용량을 예측하기 위한 방법을 제안한다. 기상청에서 제공되는 예보기온, 풍속등급 및 날씨코드와 같은 3시간 예보요소들을 분석하여 기상예보데이터와 실제 측정데이터 사이의 상관성이 분석되었다. 동적송전용량을 결정하는데 사용하기 위하여 이러한 요소들은 적당한 수치로 변환되었다. 또한 풍속과 일사량에 대한 신뢰도를 개선하기 위하여 적응뉴로퍼지시스템이 설계되었다. 기상예보데이터가 송전용량을 신뢰성을 갖도록 추정하는데 사용될 수 있음을 밝혔다. 그 결과 제안된 예측시스템이 단시간 용량예측에 효율적으로 실용화될 수 있을 것이다.