• 제목/요약/키워드: Overhead transmission line

검색결과 215건 처리시간 0.027초

혼합송전계통에서 웨이브렛 변환을 이용한 고장점 탐색 알고리즘에 관한 연구 (A Study on a Fault Location Algorithm Using Wavelet Transform in Combined Transmission Systems)

  • 정채균;이종범;윤양웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권5호
    • /
    • pp.247-254
    • /
    • 2002
  • This paper describes a fault location algorithm in real combined transmission systems with underground power cable. The algorithm to calculate the fault location was developed using DWT wavelet transform and travelling wave occurred at fault point. And the proposed algorithm is also used the transient signal of one end in stead of the signal information of two ends. On the other hand, in this papers, the method to discriminate fault point between overhead line and cable section is also Proposed. Variety simulations were carried out to verify the accuracy and effectiveness of the proposed algorithm using EMTP/ATFDraw and Matlab. Simulation results show that the proposed method has the excellent ability for discrimination of fault section and fault location in combined transmission systems with power cables.

초고압 가공 송전선로의 라디오 잡음 예측계산식 개발 (I) (Formulas for Predicting Radio Noise from Overhead HVAC Transmission Lines)

  • 양광호;주문노;명성호;신구용;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1088-1090
    • /
    • 1999
  • The radio noise produced by corona discharge in high voltage transmission tines is one of the most important line design considerations. Therefore it is necessary to pre-evaluate radio noise for transmission line designers using Prediction formulas or field test results. In this Paper, more accurate and useful formulas for Predicting radio noise during fair and foul weathers in AC transmission lines were proposed through comparison with the existing formulas. Also it was verified by comparing with the long-term measured data from operating lines that the Proposed formulas are very accurate. The Proposed prediction formulas are developed by the applications of nonlinear least square optimization method to radio noise database collected from lines throughout the world.

  • PDF

혼합송전계통에서 재폐로 해석을 위한 모델수립 및 개폐과전압해석 (Modeling and Switching Overvoltage Analysis for Reclosing Analysis in Combined Transmission Systems)

  • 임광식;이종범;강지원;정채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.442-443
    • /
    • 2008
  • This paper describes modeling using the EMTP/ATPDraw for reclosing analysis in 154kV combined transmission systems, and analyzes switching overvoltage. Current transformer established at lead-in area and lead-out area in transmission line and circuit breaker were modeled using TACS in the EMTP/ATPDraw. And also MODELS was constructed by signal processing of the operating reclosing. The simulation was carried out the switching overvoltage according to the length of overhead and underground transmission line, overvoltage between sheath and earth, and voltage between joint boxes.

  • PDF

AC/DC 하이브리드형 혼합송전계통에서 DC 케이블의 유도전압평가에 의한 적정배열 선정 (Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems)

  • 손용대;이종범
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.680-688
    • /
    • 2015
  • Hybrid type combined transmission systems is being operated by AC and DC line at the same space will be expanded instead of the overhead line. However, such hybrid type combined system has problem like the arrangement selection of DC cable for effective system operation. In this paper, to select the proper arrangement of DC cable, induced voltage of DC cable influenced by AC cable was analyzed in case of several type arrangement of DC cable. Such induced voltage is in detailed analyzed not only in case of steady, but transient state. The arrangement which has the lowest induced voltage is selected as the proper one. EMTP/ATPDraw is used for modeling and analysis of hybrid type combined transmission system.

송전용 폴리머 애자의 산불영향 신뢰성 평가(I) (Reliability Assessment of Forest Fire on Transmission Lines Polymer Insulator(I))

  • 최인혁;이동일;전영준;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.425-428
    • /
    • 2004
  • 65% of the Korean peninsula is composed of mountainous area, 97% of which is composed of forest. Therefore, there is high possibility of mountain fire because a lot of potential inflammables such as fallen leaves are stacked on the ground. Moreover, most of the overhead transmission lines in Korea are operated on the mountain. However, there has been very little study for the effect of mountain fire on polymeric insulator for transmission line, though the study is significantly required Therefore, in this study the authors observed the deformation of the housing of the insulator under fire with respect to the ignition time, using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator by dry withstand voltage test, impulse flashover test and tensile load test.

  • PDF

초고압 송전선로에 의한 TV Ghost 장해 발생 특성 (Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line)

  • 주문노;양광호;이동일;신구용
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • 제27권5호
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

Vortex induced vibration and its controlling of long span Cross-Rope Suspension transmission line with tension insulator

  • Tu, Xi;Wu, Ye;Li, Zhengliang;Wang, Zhisong
    • Structural Engineering and Mechanics
    • /
    • 제78권1호
    • /
    • pp.87-102
    • /
    • 2021
  • Long span cross-rope suspension structure is an innovative structural system evolved from typical Cross-Rope Suspension (CRS) guyed tower, a type of supporting system with short span suspension cable supporting overhead power transmission lines. In mountainous areas, the span length of suspension cable was designed to be extended to hundreds or over one thousand meters, which is applicable for crossing deep valleys. Vortex Induced Vibration (VIV) of overhead power transmission lines was considered to be one of the major factors of its fatigue and service life. In this paper, VIV and its controlling by Stockbridge damper for long span CRS was discussed. Firstly, energy balance method and finite element method for assessing VIV of CRS were presented. An approach of establishing FE model of long span CRS structure with dampers was introduced. The effect of Stockbridge damper for overall vibration of CRS was compared in both theoretical and numerical approaches. Results indicated that vibration characteristics of conductor in long span CRS compared with traditional tower-line system. Secondly, analysis on long span CRS including Stockbridge damper showed additional dampers installed were essential for controlling maximum dynamic bending stresses of conductors at both ends. Moreover, factors, including configuration and mass of Stockbridge damper, span length of suspension cable and conductor and number of spans of conductor, were assessed for further discussion on VIV controlling of long span CRS.

전력선통신을 위한 고압 배전선로의 방사전계강도 계산 (Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication)

  • 천동완;박영진;김관호;신철재
    • 한국통신학회논문지
    • /
    • 제30권12A호
    • /
    • pp.1136-1146
    • /
    • 2005
  • 본 논문에서는 전력선 통신을 위해 사용되는 고압 배전선로에서 통신신호 및 잡음신호에 의해 방사되는 방사전계강도를 계산하였다. 전력선 통신 네트워크의 2포트 등가모델 및 기본적인 전송선로 이론을 이용해 입력임피던스를 계산하였다. 그리고 계산된 입력임피던스를 이용해 전력선상 전류를 계산하고 최종적으로 방사전계강도를 계산하였다. 전력선의 특성임피던스가 매우커서 입력 단에서의 반사가 심하기 때문에 입력임피던스는 일정한 주기를 가지는 정재파 형태를 가진다. 계산된 전류 및 방사전계 또한 이러한 형태임을 알 수 있었다. 실제 측정한 결과계산 치와 측정치가 매우 유사함을 알 수 있었다.

사회적 갈등을 갖는 송전선로 경과지 선정에 관한 연구 (A Study on Selection of an Overhead Electrical Transmission Line Corridor with Social Conflict)

  • 손홍철;문채주;김학재
    • 한국전자통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.577-584
    • /
    • 2021
  • 전기에너지는 현사회에서 가장 필수적인 요소이고 우리 기술사회의 중요한 근간이다. 새로운 전력 인프라를 설계하는데 있어서 우리의 문화적인 고려사항과 공동체 환경의 필수적인 요소처럼 개발하는 방향을 심리적인 관점에서 검토하는 것이 중요하다. 새로운 고압송전선로 건설은 사회적인 반대 때문에 정부의 공공정책에 대한 갈등주제가 되고 있다. 공동체 구성원들은 이 송전선로가 그들의 건강과 안전에 영향을 끼치는 이유로 인해서 자기들의 생활에 어떤 영향을 줄 것인지에 관해서 걱정하고 있는 것이다. 경관과 시각적인 효과는 지역사회에서 가장 손쉽게 인지하는 것 중 하나이다. 새로운 경관의 3차원 컴퓨터 모사는 지역사회에 대하여 최소한 예상되는 관측성을 갖는 전력선 경로선택에 맞추어진 실생활의 사진이다. 본 논문은 송전선로 영역의 계획, 조사, 기본 및 상세경로, 경로구축을 위해서 ArcGIS를 사용하였다. 그리고 송전선로 영역의 데이터베이스를 사용하여 자연경관, 생활환경, 안전성과 고도에 대한 지도를 제시하였으며, 이 연구를 통하여 송전영역 모델을 개발하였다. 송전선로 지역에서 최소한의 가시권을 갖도록 컴퓨터로 모사하여 제안된 경관은 지역사회의 반발을 줄일 수 있으며, 새로운 전력선의 공사를 촉진할 수 있다.