• Title/Summary/Keyword: Overflow Valve

Search Result 20, Processing Time 0.032 seconds

Implementation of Overflow Valve and Performance Evaluation System for Diesel Cars (디젤차량용 오버플로어밸브 및 성능평가 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1890-1895
    • /
    • 2013
  • In this paper, we have implemented an overflow valve for EURO5 Type and the performance evaluation system based on IT. On injecting a diesel oil into an engine, it is necessity for an overflow valve that can sustain an engine oil status in front of the engine. In order to evaluate the performance of overflow valve, we need the leak test system with IT. The leak test system checks the pressure, switching time and operating time.

A Study on the Development of Overflow Cutoff Valve for Liquefied Petroleum Gas Cylinders (액화석유가스 용기용 과류차단밸브의 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.158-161
    • /
    • 2005
  • This research is about overflow cutoff valve for liquefied petroleum gas cylinders. This valve was developed based on Bernoulli's equation and Newton's equation. The structure of overflow cutoff valve was made by insert module instead of the ordinary valve that is used at present. Recently, the increase in use of gas for fuel in houses has resulted to more frequent occurrences of gas related accidents. In Korea, the government has made a law for the obligatory use of the cutoff valves. This cutoff valve is not ya developed. This research focuses on the use of over flow cutoff valve for LPG cylinders. If this valve is adapted, many accidents can be prevented.

Overflow Valve and Performance Evaluation System for Diesel Cars based on Spring Load (스프링하중을 고려한 디젤차량용 오버플로우 밸브 성능평가)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.200-204
    • /
    • 2016
  • In this paper, we have estimated the performance of an overflow valve for EURO type CRDI(common rail direct injection) engine. In order to implement the overflow valve with friendly circumstance, it is necessity for considering spring load. Especially, the performance evaluation of diesel car with accuracy control will be considered a mileage improvement and circumstance regulation. In order to evaluate the performance of overflow valve, The leak test system checks the pressure, switching time and operating time under 3.0 bar below 100 cc, 3.3 bar among 150 cc and 200 cc, finally 4.0 bar upper 250 cc.

Performance Evaluation Monitoring System of EURO5 Type Valve for Overflow (EURO5형 오버플로어 밸브 성능평가 모니터링 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • In this paper, we have implemented an overflow valve for EURO5 Type and the performance evaluation system based on IEEE802 protocol. On injecting a diesel oil into an engine, it is necessity for an overflow valve that can sustain an engine oil status in front of the engine. In order to evaluate the performance of overflow valve, we need the leak test system with IT. The leak test system checks the pressure, switching time and operating time.

A Study on the Performance Characteristics of Low Pressure Hydraulic Circuit of Common Rail System (커먼레일 시스템용 저압 유압회로의 성능특성에 관한 연구)

  • Lee, Choon-Tae
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • High pressure common rail injection technology has revolutionized the diesel industry. Over the last decade it has allowed engine builders to run higher injection pressures as much as above 1,300bar in order to increase engine efficiency, while reducing emissions. This common rail system has low pressure circuit which is consist of low pressure pump, cascade overflow valve and flow metering unit. The low pressure pump's purpose is to feed fuel oil to the high pressure pump. The cascade overflow valve keeps pressure in front of the metering unit constant and provides lubrication for the high pressure pump. The metering unit, known as the MPROP or fuel pressure regulator, regulates the maximum flow rate delivers to the rail. In this paper, we have investigated the performance characteristics of each components and total low pressure circuit of common rail system.

An Experimental Study on the Cut off Performance Test of Cut off Type Overflow Valve in L.P Gas (과류(過流) 차단형(遮斷型) 액화(液化) 석유(石油)가스 용기용(容器用) 밸브의 차단(遮斷) 성능(性能) 시험(試驗)에 관(關)한 실험적(實驗的) 연구(硏究))

  • LEE, JIN
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.116-122
    • /
    • 1992
  • The purpose of this paper is to determine the cut off flowrate regions of the overflow valve in using L.P gas vassels. The experimental methods were employed to measure the cut off flowrate in the state of constant pressure by using the $N_2$ gas. 1) To determine the optimum cut off flowrate regions, Hose length are required 0.5 meters. 2) Cut off fowrate regions about the each pressure can be suggested as follows. A) Cut off flowrate rigions are $2.0-4.0m^3/hr$ at the pressure of the $1Kg_f/cm^2$. B) Cut off flowrate rigions are$7.0-10.0m^3/hr$ at the pressure of the $10Kg_f/cm^2$.

  • PDF

Performance Analysis of Emergency Shut-Off Safety Valve (긴급차단용 안전밸브의 성능해석)

  • Song, H. Y.;Park, K. A.;Ko, S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.413-418
    • /
    • 2001
  • Emergency shut-on valve was developed to shut off natural gas at the front of a gas meter in the house. The shut-off flow rate and differential pressure of this valve was controlled by adjusting the distance between the spool and magnet. Also the spool shape was an important factor in the performance of this valve. The experimental and computational results will be useful for the design having better performance.

  • PDF

Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control (퍼지제어를 이용한 양액 자동공급 시스템 개발)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

Optimization of distribution basin and ratio at valve opening in the water treatment process (정수공정에서 분배조 및 밸브 개도율 최적화)

  • Cho, Youngman;Ryu, Dongchoon;Yoo, Pyungjong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.559-564
    • /
    • 2015
  • Distribution basins are used widely in the water treatment process. Uniform distribution at the distribution basin is an important because it affect precipitation efficiency of sedimentation basin. Generally distribution basin has a free surface water and is consisted of a weir. Study result, when inflow of distribution basin is less, amount of overflow is much at the nearest weir from the inlet. But when inflow is much, amount of overflow is much at the far weir from the inlet. The difference of distribution amount at the pipe is affected by the curvature and length of the pipe. The magnitude of the effect is determined by the relative energy loss and the flow state of the distribution basin. Optimization of the response surface method for minimizing an amount of deviation of the distribution is a very useful technique to determine the optimal ratio of the valve opening.

A Study on Safety of Atmospheric Storage Tank through Detailed Analysis of Accident Case (사고사례 정밀분석을 통한 상압저장탱크의 안전에 관한 연구)

  • Yim, Ji Pyo;Park, Su Youl
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.41-48
    • /
    • 2019
  • In October 2018, a large fire occurred after an explosion in an internal floating roof tank (IFRT) that stores gasoline by wind lantern in Goyang city, Gyeonggi-do. Although there was no casualty damage, the fire inside the tank lasted for 17 hours, and caused a great wave socially, and it was a chance to review the safety of the atmospheric storage tank. In this study, the necessity of installing a flame arrester at peripheral vents was examined through the calculation of the size of ventilation pipe and ventilation rate of internal floating roof tanks in terms of the function of the peripheral vent. Next, the necessity of the emergency shut-off valve linked with the high-level alarm to prevent the overflow of the atmospheric storage tank was confirmed by LOPA. Finally, safety measures to prevent overpressure, flame propagation and overflow which cause major accidents in atmospheric storage tank are suggested.