• Title/Summary/Keyword: Overdenture attachment

Search Result 103, Processing Time 0.016 seconds

A COMPARATIVE STUDY ON THE DISLODGING FORCE OF MAGNETIC ATTACHMENT TO THE DENTURE RESIN BY MAGNETIC DESIGN AND FIXING MATERIALS

  • Lee, Jung-Hwa;Lee, Jong-Hyuk;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.261-268
    • /
    • 2008
  • STATEMENT OF PROBLEM: Detachment of the magnetic assembly from the denture base has been a problem in magnetic overdenture patients. PURPOSE: The objectives of this study were to compare the dislodging force by the fixing materials and the designs of the magnetic assembly, and to compare the effect between the fixing materials and the designs of the magnetic assembly. MATERIAL AND METHODS: Two fixing materials, Jet denture repair $acrylic^{(R)}$ and Super-$Bond^{(R)}$ C&$B^{(R)}$ and two types of magnetic assembly designed with or without wing were used. Each magnetic assembly was fixed in the chamber of the denture base resin block ($Lucitone^{(R)}$199) with each fixing material respectively. These specimens were thermocycled 2,000 cycles in the water held at $4^{\circ}C$ and $60^{\circ}C$ with a dwell time of 1 min each time. Each specimen was seated in a testing jig and then a push-out test was performed with a universal testing machine at a cross head speed of 0.5 mm/min to measure the maximum dislodging forces. RESULTS: Comparing the fixing materials, Super-Bond C&$B^{(R)}$ showed superior dislodging force than Jet denture repair $acrylic^{(R)}$. Comparing the design of the magnetic assemblies, the wing design magnetic assembly showed better dislodging force. Combination of the Super-Bond C&$B^{(R)}$ as a fixing material and wing design magnetic assembly revealed a greatest dislodging force. The kind of fixing material was more influential than the type of magnetic assembly. CONCLUSION: The dislodging force of Super-Bond C&$B^{(R)}$ was significantly higher than Jet denture repair $acrylic^{(R)}$. And the dislodging force of magnetic assembly which have wing design was significantly higher than magnetic assembly which have no wing design.

Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles (Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.283-290
    • /
    • 2011
  • Purpose: This study compared the marginal bone loss around dental implant that were placed in the canine areas of the mandibles and finded the survival rate of implants, marginal bone loss around implants and prosthetic complications in 10 patients treated with overdentures retained with Locator attachments. Materials and methods: Ten patients who had received implant retained overdentures in the mandibules using two implants and Locator attachments at Daegu Catholic University Medical Center from 2004 to 2010 were included in this study. Evaluations of the survival rate of implants, marginal bone loss and prosthetic complications were performed. Results: Implants placed in this study showed a 100% survival rate and the average annual bone loss was 1.03 mm ${\pm}$ 0.20 mm in the first year. The patients have verbally indicated that they are comfortable and that their overdentures function well. But, implant retained overdentures had various prosthetic complications such as male change, relining, rebasing and denture fracture. Conclusion: Implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Strains of abutment and bones on implant overdentures (임플란트 피개의치에서 지대주와 골의 변형률에 관한 연구)

  • Kim, Myung-Seok;Heo, Seong-Joo;Koak, Jai-Young;Kim, Sung-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.222-231
    • /
    • 2009
  • Statements of the problem: Over the past decades, conventional complete dentures were used for various patients although they have incomplete function. Overdentures using dental implants could help the improvement of denture function. Purpose: The purpose of this study was to compare the strains of abutment and bone on implant overdenture between splinted and unsplinted type of prosthesis. Additionally, the strain values of parallel placed implant model and unparallel placed implant model were compared. Material and methods: Two acrylic resin model were prepared and two implants were placed at the canine positions in each model. In the first model, two implant were placed parallel. In the second model, two implants were placed with 10 degree labiolingual divergence. Two types of abutment were connected to the fixtures alternatively. One was splint type of Hader bar, the other was unsplint type of ball abutment. Overdentures were fabricated with corresponding attachment systems and seated on abutments. Strains of abutments and labial bone simulants were measured with electric resistance strain gauges when static load from 100 N to 200 N were applied to overdentures. Results: 1. Splinted type of overdentures using bar and clip showed higher absolute strain values. But the strain was compressive and the load was shared by two implants(P<.05). 2. Unsplinted type overdentures using ball and O-ring showed low absolute strain values(P<.05). 3. Labially inclined implant showed higher tensile strain values in unsplinted type of prosthesis than in splinted type of prosthesis. Lingually inclined implant showed rather low strain values under load(P<.05). 4. Non parallel implant model showed higher absolute strain values than parallel placed implant model comprehensively(P<.05).