• 제목/요약/키워드: Overcurrent relay

검색결과 59건 처리시간 0.025초

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

디지털 역결상 보호 계전기의 설계 및 제작 (Design and Fabrication of a Digital Protection Relay for Reverse-Open Phase)

  • 김우현;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.313-319
    • /
    • 2019
  • Induction motors connected with a three-phase AC system may malfunction due to reverse phase or open phase faults. Conventional overcurrent relays and overheating relays are used to prevent such accidents; however, their drawbacks include a low response speed and false operation. Therefore, in this study, a digital relay for the reverse-open phase was designed and fabricated. This relay can detect the reverse phase and open phase faults and send a trigger signal to the control circuit. The proposed relay was developed based on a microcontroller. The detection times of the reverse phase and open phase were verified as 320ms and 80ms, respectively. Compared with conventional relays that only protect the motor from one type of fault, the proposed relay can detect both, reverse phase and open phase faults. In addition, the fault detection, identification criterion, and trigger signal patterns can be modified by programming according to the requirements of users.

PSCAD를 이용한 상시 루프배전시스템의 보호계전기 모델 (A PSCAD Modeling of Protection Relay of On-Line Distribution System)

  • 김진수;박진현;조보현;문원식;조성민;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.406-407
    • /
    • 2011
  • The closed-loop distribution system is more flexible and more reliable than radial system. If any type fault occurs, the reliability of system can be better by providing electrical energy through another distribution line. However, it needs protection device coordination of different type. Typically, it is available by using directional overcurrent relay (67). This paper gives a solution about loop protection relay modeling which can be used by the simulation tools.

  • PDF

열 모델을 이용한 전동기 보호성능 개선 (Improving Motor Protection Using Thermal Model)

  • 장중구
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.473-479
    • /
    • 2015
  • Thermal relays are sometimes used instead of long time overcurrent relays for motor protection. But, it is difficult for any relay design engineer to adequately approximate motor heating curves which represent the average of a difficult-to-define thermal zone. Thermal relays frequently may not provide sufficient protection on heavy overloads. Digital multifunction relays are microprocessor-based devices. These relays offer highly reliable and advanced protection of motors. If a situation can be mathematically described, the microprocessor in a digital relay can be programmed to tackle that problem. Today's motor protection is accomplished with digital protective relays. Digital relays offer additional, highly important features to complement protection. The best way to prevent short in motor is to not overheat and degrade the insulation.

IEC 61850 기반 후비보호계전시스템 보호협조 개선방안 (Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850)

  • 김형규;강상희
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

유리 성형기의 무접점릴레이(SSR) 수명 예측장치 개발 (Development of Solid State Relay(SSR) Life Prediction Device for Glass Forming Machine)

  • 양성규;김갑순
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.46-53
    • /
    • 2022
  • This paper presents the design and manufacture of a Solid State Relay (SSR) life prediction device that can predict the lifetime of an SSR, which is a key component of a glass forming machine. The lifetime of an SSR is over when the current supplied to the relay is overcurrent (20 A or higher), and the operating time is 100,000 h or longer. Therefore, the life prediction device for the SSR was designed using DSP to accurately read the current and temperature values from the current and temperature sensors, respectively. The characteristic test of the manufactured non-contact relay life prediction device confirmed that the current and temperature were safely measured. Thus, the SSR lifetime prediction device developed in this study can be used to predict the lifetime of an SSR attached to a glass forming machine.

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

Optimal Coordination of Overcurrent Relays in the Presence of Distributed Generation Using an Adaptive Method

  • Mohammadi, Reza;Farrokhifar, Meysam;Abyaneh, Hossein Askarian;Khoob, Ehsan
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1590-1599
    • /
    • 2016
  • The installation of distributed generation (DG) in the electrical networks has numerous advantages. However, connecting and disconnecting of DGs (CADD) leads to some problems in coordination of protection devices due to the changes in the short circuit levels in the different points of network. In this paper, an adaptive method is proposed based on available setting groups (SG) of relays. Since the number of available SG is less than possible CADD states, a classifying index (CI) is defined to categorize the several states in restricted setting groups. Genetic algorithm (GA) with a suitable objective function (OF) is used as an optimization method for the classification. After grouping, a modified coordination method is applied to achieve optimal coordination for each group. The efficiency of the proposed technique is demonstrated by simulation results.

발전기 고장보호를 위한 디지털 계전기에 관한 연구 (A Study on the Digital Protective Relay for Generator Fault Protection)

  • 장낙원;박정도;이성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1232-1238
    • /
    • 2009
  • 전력설비의 대용량, 고전압화 됨에 따라 발전기 고장 예방을 위한 고장보호시스템의 필요성이 점차 증대되고 있다. 신속하고 신뢰성 있게 운전하며 보호하는 발전기 보호제어 시스템의 개발이 시급히 요구된다. 본 논문에서는 전력 공급의 안정을 도모하고 대용량, 고전압화 되는 발전기의 고장 예방을 위한 발전기 보호기능을 갖춘 디지털 보호계전기 설계에 관한 연구를 수행하였다. 디지털 계전기의 발전기 고장보호에 사용되는 고장보호 알고리즘을 개발하였고 디지털보호계전기 H/W를 설계 제작하였다.

경전철 시험선로의 직류 보호시스템 및 보호계전기 설계 (The Design of the DC traction Protection system and Device for the test line of Light Rail Transit)

  • 전용주;김지홍;백병산;김남해;이병송;안재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1229-1231
    • /
    • 2002
  • This paper presents the design of DC protection system of Light Rail Transit system. Especially, the composition and interface for DC Switchgear. Digital protection unit and sort of protection algorithm are focused. DC Switchgear (DCSWGR) for LRT testline consist of 5 different panels with peculiar characteristics are examined. Also Basic actuation principle for DC fault select relay (50F), Line Test Device (LTD), DC Overcurrent(OCR) relay are introduced.

  • PDF