• Title/Summary/Keyword: Overcome

Search Result 13,881, Processing Time 0.044 seconds

Comparison of Genetic Algorithm and Simulated Annealing Optimization Technique to Minimize the Energy of Active Contour Model (유전자 알고리즘과 시뮬레이티드 어닐링을 이용한 활성외곽선모델의 에너지 최소화 기법 비교)

  • Park, Sun-Young;Park, Joo-Young;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.4 no.1
    • /
    • pp.31-40
    • /
    • 1998
  • Active Contour Model(ACM) is an efficient method for segmenting an object. The main shortcoming of ACM is that its result is very dependent on the shape and location of an initial contour. To overcome this shortcoming, a new segmentation algorithm is proposed in this paper. The proposed algorithm uses B-splines to describe the active contour and applies Simulated Annealing (SA) and Genetic Algorithm(GA) as energy minimization techniques. We tried to overcome the initialization problem of traditional ACM and compared the result of ACM using GA and that using SA with 2D synthetic binary images. CT and MR images.

  • PDF

A Six Sigma Model for Small and Medium SizedCompanies and Case Studies (중소기업을 위한 6시그마 모형 및 사례 연구)

  • Hwang, Young Je;Kwon, Hyuck Moo;Hong, Sung Hoon;Lee, Min Koo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.4
    • /
    • pp.291-297
    • /
    • 2006
  • Since the six sigma strategy was first introduced to Korean enterprises in 1997, it has been taken as an important business strategy to strengthen the competitiveness of major Korean companies under the global competitive environment. These major companies also demand their suppliers to implement six sigma. But small and medium sized companies have several barriers to overcome for successful implementation of six sigma. First, the financial status is not so sound to support initial expenses for launching six sigma. Second, physical and human resources are not sufficient for driving six sigma. And finally, the infrastructure is not well established to manage and support the six sigma program. In this paper, we suggest a method to overcome these barriers and propose a model for establishing six sigma in a small and medium sized company. We also provide some practical case studies.

Recent NMR developments for pharmaceutical research

  • Lee, Kwanghwan
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.20 no.1
    • /
    • pp.27-35
    • /
    • 2016
  • NMR spectrometer has been regarded as essential tool for structure elucidation in variable scientific field as like organic synthesis, natural product and macro protein research. Also NMR can be applied for defining dynamic behavior like ligand and receptor binding. One of advantage of research with NMR is that to be great confident to confirm structure and the measured sample could be recovered. Nevertheless NMR also has a weak points than other spectroscopic methods that require a lot of time for interpreting acquired spectrum and running time due to low sensitivity. For last two decade Bruker has developed hardware and software solution for overcome those weak points. In order to overcome low sensitivity Bruker introduced Cryo and Micro diameter probe head technology. And researcher can reduce the time for routine spectrum processing and interpretation works due to lots of introductions in software solutions for quantification, identification and statistics analysis. With four examples, this article describing those new hardware and software solutions in field of recent pharmaceutical research as follows. - New Horizons for NMR in the Biopharmaceutical Industry - The development and application of solid-state NMR spectroscopy (SSNMR) in pharmaceutical analysis - Assisted NMR Data Interpretation in Synthetic Chemistry - Complete Analysis of New Psychoactive Substances Using NMR.

A Study on Chemical Cleaning of Electrolytic Facilities with Sea Water (해수전해설비의 화학세정 최적화 방안에 관한 연구)

  • 이한철;이창우;현성호
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.114-119
    • /
    • 1999
  • When NaOCl was generated and put into sea-water cooling machine in order to overcome the biological hindrances against sea-water cooling machine, it was converted into metallic ion, particularly Ca and Mg, as a hydrate in sea-water and is to stick to electrolyte as a side reaction. This phenomena make the distance between the electrolytes narrow to decrease the flow rate, which induces the local vortex flow which erodes the pole plate. Moreover, this increases the resistance of the electrolyte as well as voltage to decrease the electrolytic efficiency, which has curtailed a chlorine yield and caused a pole plate cut. We are able to overcome these problems by chemical cleaning and intend to extend the life-time of electrolyte and to increase output of the sea-water electrolysis facilities by studying optimal policy regarding chemical cleaning of electrolytic cell. Cleaning time of electrolytic facilities is determined when both increase in electrolytic efficiency and decrease in pole-plate voltage are 10%. At this time as operating current of electrolytic facilities is high, operating time is diminished. Whereas, parameter of end point determination according to cleaning is Mg ionic concentration in solution. When we use Cleaner as a 7wt% HCl, cleaning time is about 80min proper. We are able to maintain pole plate performance by protecting against pole plate cut by means of electrolytic by-product, improve operating rate of facilities, and cut down on maintenance expenditure after acidic cleaning.

  • PDF

Evaluation of Chest Density in Insight Film (Insight film을 이용한 농도측정 평가)

  • Kwon, Lee-Seon;Park, Jang-Hwan;Lim, Oh-Soo;Jung, Kyong-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.17-23
    • /
    • 1992
  • Simple chest radiography is the most frequently performed examination in radiologic practice. However, with transmitted dose through chest which has the problem of wide variations in absorption, conventional Film/Screen Combinations Method make it difficult to delineate lung field mediastinum & cardia portion and subdiaphragmatic structures. In order to overcome this problem, we have been tried several methods as follows. High Kilovoltage Technique, Rare Earth Screen/Wide Lattitude Film, Use of Compensating Filter and Digital Beam Attenuator and recently Insigh System has been developed. In this paper, we'd like to discuss Insight film through apperciation by measuring the difference of contrast. In order to evaluate insight film. We have done experiments using Insight System with Simple Phase, Picker 550. We could get an result which was able to overcome the limitted dynamic range of conventional Film/Screen System remarkably.

  • PDF

Discrete Element Method using the Superposed Rigid-Rod Model for the Dynamic Behavior of Needle-Shaped Powder with a High Aspect Ratio (높은 세장비를 가진 침상형 입자의 동적 거동 해석을 위한 중첩형 강체막대모델을 이용한 이산요소법)

  • Kim, YoungHo;Park, Junyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.22-27
    • /
    • 2018
  • One problem of the Discrete Element Method is the assumption of a spherical particle shape, which reduces the computing time but significantly limits the application of the DEM to analysis. This limitation can be overcome by a recently developed rigid-rod model. However, the rigid-rod model has an essential problem related with friction: it always contains friction error because of the bumpy surface. To overcome this issue, we suggest a superposed rigid-rod model in this paper. The superposed rigid-rod model is notably consistent with the theoretical value in terms of the velocity and angular velocity after the collision. The estimated error is negligible(less than 2%). Then, the developed model is applied to hopper discharging. The developed model shows no problem in the discharging flow from the hopper.

Reliability Design of MEMS based on the Physics of Failures by Stress & Surface Force (응력 및 표면 고장물리를 고려한 MEMS 신뢰성 설계 기술)

  • Lee, Hak-Joo;Kim, Jung-Yup;Lee, Sang-Joo;Choi, Hyun-Ju;Kim, Kyung-Shik;Kim, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1730-1733
    • /
    • 2007
  • As semiconductor and MEMS devices become smaller, testing process during their production should follow such a high density trend. A circuit inspection tool "probe card" makes contact with electrode pads of the device under test (DUT). Nowadays, electrode pads are irregularly arranged and have height difference. In order to absorb variations in the heights of electrode pads and to generate contact loads, contact probes must have some levels of mechanical spring properties. Contact probes must also yield a force to break the surface native oxide layer or contamination layer on the electrodes to make electric contact. In this research, new vertical micro contact probe with bellows shape is developed to overcome shortage of prior work. Especially, novel bellows shape is used to reduce stress concentration in this design and stopper is used to change the stiffness of micro contact probe. Variable stiffness can be one solution to overcome the height difference of electrode pads.

  • PDF

Development of Conical Spring-based Jumping Mechanism for a Portable Robot (소형로봇을 위한 원추형 스프링 기반의 도약 메커니즘의 개발)

  • Kim, Byeong-Sang;Lee, Jang-Woon;Kim, Hyun-Jung;Vu, Quy-Hung;Song, Jae-Bok
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1195-1200
    • /
    • 2007
  • It is desirable that the guard robot should be small-sized and light-weighted to increase its portability. In addition, it should be able to overcome a relatively high obstacle to cope with different situations. The jumping robot can reach a higher place more rapidly than other locomotion methods. This research proposes the jumping mechanism based on the conical spring for a small robot. Both the clutch mechanism and conical spring are incorporated into the jumping mechanism. In the clutch mechanism, the spring can be immediately compressed and released by one actuator with the planetary gear train and one-way clutch. The robot equipped with the jumping mechanism can overcome the obstacles which are higher than its height. In this paper, the characteristic of the conical spring for the jumping robot is determined and the small-sized, lightweight jumping mechanism is developed. The validity of the jumping mechanism was verified by various experiments. It is shown that the robot using this mechanism can provide good mobility in the rough terrain.

  • PDF

Dermis Graft for Wound Coverage: A Preliminary Report (창상피복을 위한 진피이식술의 예비보고)

  • Yoon, Tae-Hwan;Han, Seung-Kyu;Kim, Jung-Bae;Ki, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.267-270
    • /
    • 2005
  • The two major concerns in skin grafting are poor color match at the recipient site and donor site morbidity. To overcome the limitations of the classic skin graft, we have used dermis graft-deepithelialized split thickness skin graft-for coverage of small to medium sized wounds. The important aspects of this methods involve the immediate return of epidermis to the donor site to overcome donor site morbidity and restoration of the epidermis at the recipient site by neo epithelization from the adjacent skin. From April of 2001 to July of 2003, the dermis graft was applied to 32 patients. Simultaneously, the regular split thickness skin graft procedure was performed in 33 patients. We compared the healing time in all patients. The scar condition was also evaluated at 2 to 12 months after operation. The entire dermis grafts were reepithelialized in 15.5 days. The skin grafted wounds were healed by 11.8 days. Regarding the donor sites, donor sites of dermis graft healed within 7.5 days. On the contrary those of regular skin graft required 12.8 days. The donor sites of the dermis graft were also superior to those of skin graft in scar quality and patient satisfaction. The dermis graft technique for wound coverage compares favorably to regular skin graft technique in both recipient and donor sites aesthetically and functionally.

Proposal of Research Methodology Using The Measurement of Perception Difference

  • YANG, Hoechang
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.2 no.2
    • /
    • pp.39-45
    • /
    • 2019
  • The purpose of this study is to solve the problem of revision or abbreviation of questionnaires based on the previous studies suggested by many existing empirical studies. In addition, this study aims to provide the theoretical basis of the research method which has been variously approached since it presents the methodology that can directly measure the research object. For this purpose, this study proposed a more elaborate analysis method using the differences in perception of individuals who are interested in cognitive research. Specifically, the perception gap(D) can be used as an independent variable, a dependent variable, and a moderating variable. And this study suggested an effective research approach using the measurement of perception difference. The difference of perception suggested that it can be used as a measure to overcome the limitations of existing researches used it as independent variables or mediating variables that measure only one factor of expectation and performance or importance and satisfaction. In addition, it is highly likely that various analyzes on the perception differences, which are the result of measuring target factors for the same person, will be quite effective in the situation where follow-up of respondents is difficult. This study is expected to overcome various limitations reported by empirical studies such as scale utilization problem and follow-up survey difficulty. In future research, it was expected that the limitation of the factor derivation process in the research approach could be complemented by web crawling and text mining of big data analysis.