고상반응법에 의해 제조된 $Li_{0.44}MnO_2$의 전기화학적 성질에 미치는 Ti 치환의 영향 (Effect of Ti substitution on electrochemical properties $Li_{0.44}MnO_2$ synthesized by solid state reaction)

  • 황광택
    • 한국결정성장학회지
    • /
    • 제10권5호
    • /
    • pp.362-366
    • /
    • 2000
  • $Li_{0.44}MnO_2$양극재료는 리튬의 삽입과정에서 높은 가역성을 가지며 과충전이나 과방전 과정에서 쉽게 손상되지 않는다. $Mn_2O_3$가 불순물로 자주 나타나며 전기화학적으로 비활성이기 때문에 전극의 전기화학적 용량을 감소시킨다. 잉여의 NaOH 첨가는 $Mn_2O_3$를 X선 회절에 검출되지 않는 정도로 낮추었다. 용량 증가는 큰 단위세포를 가지는 양극재료에서 얻어질 수 있으므로, 망간의 일부를 이온반경이 큰 티타니움으로 치환하였으며, $Li_{0.44}T_{iy}Mn_{1-y}O_2$(여기서 y = 0.11, 0.22, 0.33, 0.44, 0.55) 조성의 분말들을 합성하여 특성을 평가하였다. ECPS 실험결과 $Li/P(EO)_8$LiTFSI/$LixTi_{0.22}Mn_{0.78}O_2$전지에서 150 mAh/g 최대가역용량 값이 얻어졌다. 티타니움이 치환된 망간산화물을 사용한 전지는 충방전당 0.12 %나 그 이하의 용량감소율을 나타내었다.

  • PDF

폐리튬이온전지로부터 분리한 양극활물질의 침출 (Leaching of Cathodic Active Materials from Spent Lithium Ion Battery)

  • 이철경;김태현
    • 자원리싸이클링
    • /
    • 제9권4호
    • /
    • pp.37-43
    • /
    • 2000
  • 폐리륨이온전지의 재활용 일환으로 폐전지에서 분리한 양극활물질인 $LiCoO_2$로부터 Li과 Co룹 회수하기 위하여 침출거동올 조사하였다. 전 연구에서 얻은 최적조건에서 $LiCoO_2$를 1M 황산과 질산으료 침출하였을 때 Li과 Co의 침출율이 각각 70-80%, 40%로 Co의 침출율이 낮았다. 환원제를 첨가한 경우 Li과 Co의 침출율이 증가하였는데, 특히 $Na_2S_2O_3$$H_2O_2$ 와 같은 환원제에서 질산침출을 하는 경우 Li괴- Co의 용해가 거의 95% 이상 이루어졌다. 이는 환원제가 $Co^{3+}$$Co^{2+}$로 환원시켜 침출이 용이해졌기 때문으로 생각된다. 변수설험을 통하여 얻은 최적의 조건(광액농도 10g/l 반응온도 $75^{\circ}C$, 교반속도 400 rpm' 1.7 vol% $H_2O_2$)에서 폐리튬이온전지로부터 선별하고 열처리한 $LiCoO_2$ 분말을 침출 실험한 결과, Li과 Co의 침출율이 각각 99% 이상이었으며, 이는 충방전이 거듭되면서 양극활물질인 $LiCoO_2$이 화학적으로 활성화되었거나 Li의 탈착으로 겸정구조가 불안하기 때문으로 생각된다.

  • PDF

수직 이착륙 무인기용 배터리 전력 시스템 설계 및 지상 시험 평가 (The Design of a Battery Power System and Its Performance Evaluation on the Ground for Vertical Takeoff and Landing Drones)

  • 강병규
    • 항공우주시스템공학회지
    • /
    • 제15권5호
    • /
    • pp.43-49
    • /
    • 2021
  • 본 논문은 비행시험 전 수직 이착륙 드론용 배터리 시스템 설계 및 지상 성능 평가에 대하여 다룬다. 배터리를 포함한 드론의 무게는 약 45 kg이며, 4개의 모터를 이용하여 추력을 발생 시키고 방향도 전환할 수 있는 드론이다. 30분 동안 비행임무에 필요한 전력을 시뮬레이션 하였고 그 결과 총 2.4 kWh의 전력이 필요하였다. 전압 운영 범위는 54 V ~ 44 V이며 13셀로 구성된 두 개의 배터리팩을 (4 C-rate) 제작하였다. 그리고 배터리 관리시스템을 장착하여 과전압, 저전압 및 과전류를 방지할 수 있는 기능을 추가하여 무인기 운용 안전성을 높였다. 최종적인 배터리 성능 검증을 위해 -10 ℃, 25 ℃, 40 ℃에서 시뮬레이션 방전 시험을 수행하여 비행 임무를 위한 필요 전력이 충족됨을 확인 하였다.

Development of Battery Management System for Electric Vehicle Applications of Ni/MH Battery

  • Jung Do Yang;Lee Baek Haeng;Kim Sun Wook
    • 전기화학회지
    • /
    • 제4권4호
    • /
    • pp.152-159
    • /
    • 2001
  • 전기자동차의 성능은 축전지의 성능에 의해 크게 좌우된다. 그러므로 우수한 성능과 높은 신뢰성을 가진 전기자동차를 개발하기 위해서는 다양한 운영조건에서 축전지가 최대의 성능을 가질 수 있게 잘 관리되어야 한다. 축전지의 성능 향상은 축전지 관리 시스템(BMS)의 적용에 의해 달성될 수 있으며 BMS는 축전지의 상태 감시뿐만 아니라 축전지의 충전 및 방전을 최적화하는 중요한 역할을 수행한다. 이 연구에서는 전기자동차에 적용된 니켈 메탈하이드라이드 전지(Ni/MH battery) 이용을 최대화하기 위한 역할을 수행하는 BMS를 개발하였다 이 시스템은 축전지의 충전 및 방전 제어, 과충전 및 과방전 방지, 잔존용량 계산 및 표시, 안전관리 및 열관리 등의 기능을 가진다. 금번 개발된 BMS를 대우자동차와 고등기술원이 공동 개발한 DEV5-5전기자동차에 장착하여 시험을 수행하였다. 이 차량에는 파나소닉사의 12V-95Ah사양의 Ni/MH battery 18모듈이 적용되었다 시험결과 이 시스템은 $3\%$ 이내의 높은 정확성을 가지고 있으며 우수한 신뢰성을 나타내었다. 이 BMS는 전기자동차의 신뢰성과 안전도뿐만 아니라 Ni/MH battery pack의 성능과 수명을 향상시킬 것이다.

Sand-Blasting법을 이용한 활물질/기판간 결합력 향상에 따른 AGM 연축전지의 성능 및 충방전 거동 (Performance and Charging-Discharging Behavior of AGM Lead Acid Battery according to the Improvement of Bonding between Active Material/Substrate using Sand-Blasting Method)

  • 김성준;임태섭;김봉구;손정훈;정연길
    • 한국재료학회지
    • /
    • 제31권2호
    • /
    • pp.75-83
    • /
    • 2021
  • To cope with automobile exhaust gas regulations, ISG (Idling Stop & Go) and charging control systems are applied to HEVs (Hybrid Electric Vehicle) for the purpose of improving fuel economy. These systems require quick charge/discharge performance at high current. To satisfy this characteristic, improvement of the positive electrode plate is studied to improve the charge/discharge process and performance of AGM(Absorbent Glass Mat) lead-acid batteries applied to ISG automotive systems. The bonding between grid and A.M (Active Material) can be improved by applying the Sand-Blasting method to provide roughness to the surface of the positive grid. When the Sand-Blasting method is applied with conditions of ball speed 1,000 rpm and conveyor speed 5 M/min, ideal bonding is achieved between grid and A.M. The positive plate of each condition is applied to the AGM LAB (Absorbent Glass Mat Lead Acid Battery); then, the performance and ISG life characteristics are tested by the vehicle battery test method. In CCA, which evaluates the starting performance at -18 ℃ and 30 ℃ with high current, the advanced AGM LAB improves about 25 %. At 0 ℃ CA (Charge Acceptance), the initial charging current of the advanced AGM LAB increases about 25 %. Improving the bonding between the grid and A.M. by roughening the grid surface improves the flow of current and lowers the resistance, which is considered to have a significant effect on the high current charging/discharging area. In a Standard of Battery Association of Japan (SBA) S0101 test, after 300 A discharge, the voltage of the advanced AGM LAB with the Sand-Blasting method grid was 0.059 V higher than that of untreated grid. As the cycle progresses, the gap widens to 0.13 V at the point of 10,800 cycles. As the bonding between grid and A.M. increases through the Sand Blasting method, the slope of the discharge voltage declines gradually as the cycle progresses, showing excellent battery life characteristics. It is believed that system will exhibit excellent characteristics in the vehicle environment of the ISG system, in which charge/discharge occurs over a short time.

퇴원 의지가 요양병원의 성공적 퇴원에 미치는 영향에 대한 다수준 분석 (A Multilevel Analysis about the Impact of Patient's Willingness for Discharge on Successful Discharge from Long-term Care Hospitals)

  • 강하렴;이연주
    • 보건행정학회지
    • /
    • 제32권4호
    • /
    • pp.347-355
    • /
    • 2022
  • Background: Since November 2019, long-term care hospitals have been able to provide patients with discharging programs to support the elderly in the community. This study aimed to identify both patient- and hospital-level factors that affect successful community discharge from long-term care hospitals. Methods: A multilevel logistic regression model was performed using hospitals as a clustering unit. The dependent variable was whether a patient stayed in the community for at least 30 days after discharge from a long-term care hospital. As for the patient-level independent variables, an agreement between a patient and the family about discharge, length of hospital stay, patient category, and residence at discharge were included. The number of beds and the ratio of long-stay patients were selected for the hospital-level factors. The sample size was 1,428 patients enrolled in the discharging program from November 2019 to December 2020. Results: The number of patients who were discharged to the community and stayed at least for 30 days was 532 (37.3%). The intraclass correlation coefficient was 22.9%, indicating that hospital-level factors had a significant impact on successful community discharge. The odds ratio (OR) of successful community discharge increased by 1.842 times when the patients and their families agreed on discharge. The ORs also increased by 3.020 or 2.681 times, respectively when the patients planned to discharge to their own house or their child's house compared to those who didn't have a plan for residence at discharge. The ORs increased by 1.922 or 2.250 times when the hospitals were owned by corporate or private property compared to publicly owned hospitals. The ORs decreased by 0.602 or 0.520 times when the hospital was sized over 400 beds or located in small and medium-sized cities compared to less than 200 bedded hospitals or located in metropolitan cities. Conclusion: The results of the study showed that the patients' and their family's willingness for discharge had a great impact on successful community discharge and the hospital-level factors played a significant role in it. Therefore, it is important to acknowledge and support long-term care hospitals to involve active in the patient discharge planning process.

Application of CE-QUAL-W2 [v3.2] to Andong Reservoir: Part II: Simulations of Chlorophyll a and Total Phosphorus Dynamics

  • Ram, Bhattarai Prasid;Kim, Yoon-Hee;Kim, Bom-Chul;Heo, Woo-Myung
    • 생태와환경
    • /
    • 제41권4호
    • /
    • pp.472-484
    • /
    • 2008
  • The calibrated Andong Reservoir hydro-dynamic module (PART I) of the 2-dimensional hydrodynamic and water quality model, CE-QUAL-W2 [v3.2], was applied to examine the dynamics of total phosphorus, and chlorophyll $\alpha$ concentration within Andong Reservoir. The modeling effort was supported with the data collected in the field for a five year period. In general, the model achieved a good accuracy throughout the calibration period for both chlorophyll ${\alpha}$ and total phosphorus concentration. The greatest deviation in algal concentration occurred on $10^{th}$ October, starting at the layer just beneath the surface layer and extending up to the depth of 35 m. This deviation is principally attributed to the effect of temperature on the algal growth rate. Also, on the same date, the model over-predicts hypolimnion and epilimnion total phosphorus concentration but under-predicts the high concentrated plume in the metalimnion. The large amount of upwelling of finer suspended solid particles, and re-suspension of the sediments laden with phosphorus, are thought to have caused high concentration in the epilimnion and hypolimnion, respectively. Nevertheless, the model well reproduced the seasonal dynamics of both chlorophyll a and total phosphorus concentration. Also, the model tracked the interflow of high phosphorus concentration plume brought by the turbid discharge during the Asian summer monsoon season. Two different hypothetical discharge scenarios (discharge from epilimnetic, and hypolimnetic layers) were analyzed to understand the response of total phosphorus interflow plume on the basis of differential discharge gate location. The simulated results showed that the hypolimnetic discharge gate operation ($103{\sim}113\;m$) was the most effective reservoir structural control method in quickly discharging the total phosphorus plume (decrease of in-reservoir concentration by 219% than present level).

소형 오존발생장치의 전력제어와 냉각효과에 관한 연구 (A Study on Cooling Effect and Power Control of a Mini Ozonizer)

  • 우성훈;박승조;윤성윤;박지호;우정인
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 미세 오존 출력을 얻을 수 있는 자동제어형 오존발생장치의 제어기법을 제시하고, 또한 무성방전에 의한 오존발생장치의 유입공기를 공극에서 저온인 $2^{\circ}C$까지 냉각 하여 포화 확산도가 높은 고밀도 탈취용 오존을 발생시킬 수 있는 기법을 제시한다. 고주파수의 오존방전 노이즈에 의한 전원파형의 불량화를 보상하기 위해서 디지털 궤환 제어시스템을 구성하고, 방전관의 등가 커패시터의 전압과 전류를 검출하여 2중의 제어루프를 설계한다. 부하변동에 따르는 과도상태 응답특성을 개선하고 제어기의 연산 지연시간을 보상하기 위하여 연산시간을 전원장치 플랜트의 고유한 파라미터로 가정하여 플랜트모델에 포함시켜 모델링한다. 제안된 오존 발생기는 고농도 고효율의 오존방전 시스템의 입력전원에서 고주파방전노이즈가 제거되어 정현적으로 되며 2배 이상의 안정된 오존출력을 얻는 것을 실험적으로 입증한다.

가압제 토출시 온도강하율에 대한 연구 (Study on Temperature Drop Rate during Pressurant Discharge)

  • 정용갑;홍문근;권오성;김영목
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.116-121
    • /
    • 2006
  • 액체로켓 추진시스템에서 가압시스템은 발사체 추진제 탱크의 얼리지 공간에 제어된 가스를 공급하는 것이다 가압시스템에서 고온 가스 열교환기를 적용하는 데는 가압제의 비용적을 증가시켜 전체 발사체 시스템의 중량을 감소시키는 장점이 있다. 그러므로 가압시스템 성능에 있어서 주목할 만한 개선점은 특히 극저온 시스템에서 얻어질 수 있다. 본 연구에서는 외부 유체와 가압제로 공기와 $CN_2$를 각각 적용하였다. 가압제 토출 특성에 관한 수치 해석은 PTF에서 수행된 실험 결과와 비교되었다. 해석과 실험 결과의 오차는 약 ${\pm}15%$ 이내로 나타났다. 이러한 해석적 접근을 사용하면 액체산소에 잠겨진 극저온 가압제의 온도강하율을 예측할 수 있을 것으로 사료된다.

  • PDF

온배수 방류시스템에 관한 기초적 연구 (A Study on the Discharge System of Thermal Waste Water)

  • 곽기수;전용호;김헌태;류청로;이경선
    • 한국해양공학회지
    • /
    • 제21권6호
    • /
    • pp.87-94
    • /
    • 2007
  • This study used POM (Princeton ocean model) improved for applying to coastal area in order to predict the distribution of thermal waste water. This model was applied to the coastal circulation and the effect of thermal waste water of Cheonsu-Bay. So this study compared the discharge of thermal waste water with each layer and section. The tidal current was about 1.5 m/sec at surface level and 0.9 m/sec on bottom level at flood tide; tidal current was about 1.3 m/sec on surface level and 0.8 m/sec on bottom level at ebb tide. The method discharging the thermal waste water in the nearshore region (case 1) accelerates the diffusion of the thermal waste water in the north-south direction(longshore direction). However, the method discharge the thermal waster water in the offshore region (case 2) reduced the diffusion of the thermal waste water over the coastal region. According th the diffusion region of the thermal waste water with case 1 and case 2 at three different layers (surface, middle, bottom), the diffusion region by case 1 discharge method generally influenced wider region (twice) than the one by case 2 discharge method with lower temperature between $1^{\circ}C\;and\;2^{\circ}C$, whereas the case 2 discharge method influenced the deeper region (middle and botton layers) with higher change of the water temperature ($1{\sim}3^{\circ}C$).