• 제목/요약/키워드: Over discharge

검색결과 939건 처리시간 0.026초

Electrochemical Properties of LiNiO$_2$/Li cell (LiNiO$_2$/Li cell의 전기화학적 특성)

  • 전대규;김철중;성창호;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 1997
  • The propose of this study is research and improvement of LiNiO$_2$as cathode material for Lithium secondary batteries. LiNiO$_2$is prepared by heating LiOH . $H_2O$ and Ni(OH)$_2$(mole ratio 1 : 1) on various heat condition. In the result of XRD mesurement, all LiNiO$_2$prepared at this study showed hexagonal structure. In Cyclic Voltammetry, LiNiO$_2$is not conspicous about oxidation peak but oxidation curve change steeply over 3.8V and reduction peak discover at 3.6V. In discharge capacities, specific capacity is higher $O_2$than air when preliminary heated and 75$0^{\circ}C$ than $700^{\circ}C$, 80$0^{\circ}C$ when heated. Therefore, when preliminary heat at $650^{\circ}C$ $O_2$and heat at 75$0^{\circ}C$ carried out, discharge property is the best.

  • PDF

Momentum Measurement of Induced Flow by DBD Plasma Using PIV (PIV를 이용한 DBD 플라즈마 유도 유동장 운동량의 예측)

  • Sohn, Jun Ha;Kim, Namhoon;Kim, Kyungyeon;Furudate, Michiko Ahn
    • Journal of the Korean Society of Visualization
    • /
    • 제17권1호
    • /
    • pp.53-59
    • /
    • 2019
  • Particle image velocimetry is performed in order to analyze flowfield induced by a dielectric barrier discharge plasma actuator. The velocity vector fields are obtained for the two different input voltage conditions; the voltage 3 and 5 kV at the frequency 10 kHz. The obtained flowfields show that the air is accelerated and its speed increase almost linearly over the covered electrode. The amount of momentum induced by the DBD plasma actuator is estimated from the obtained velocity fields, and the estimated values reasonably agree with the previous experiment.

A Case of Fetal Mummification and Lithopedion from a Bitch with Prolonged Gestation over about One Month (장기임신 개에서 발생한 태아미이라변성 및 석아의 1례)

  • 김용준;박영재;오홍근;한종현;이창민;강미선
    • Journal of Veterinary Clinics
    • /
    • 제17권1호
    • /
    • pp.238-242
    • /
    • 2000
  • A six-year old bitch pregnant with prolonged gestation over about one month was ovariohysterectomied. The bitch was proved to be normal by physical and biochemical examination and had not a purulent vaginal discharge. A large firm mass was palpated in left caudoventral abdomen. Radiography identified the mass as a fetus. The abdominal ultrasono-graphy identified the fetus was dead. Caesarian section through the median raphe over linea alba was attempted. Adhensions were found between the uterus, stomach, spleen, urinary bladder, and abdominal viscera. Two fragments of bone were found in the abdominal cavity because of rupture of left uterine horn. Radiography and ultrasonography were proved to be of use to diagnose prolonged fetal mummification. Ovario-hysterectomy was considered to be choice of treatment to remove the prolonged mummified fetus.

  • PDF

Analysis of Healthcare Personnel's Clinical Beliefs and Knowledge behind Overutilization of Stress Ulcer Prophylaxis in Hospitalized Patients (스트레스성 위장궤양 예방치료제 처방남용에 대한 의료전문가의 인식과 지식 분석)

  • Noh, Yoojin;Lee, Jae Myeong;Shin, Sooyoung
    • Korean Journal of Clinical Pharmacy
    • /
    • 제25권4호
    • /
    • pp.264-272
    • /
    • 2015
  • Background: The over-prescription of acid-suppressive therapy for the provision of stress ulcer prophylaxis (SUP) in hospitalized patients has been identified in a proceeding study. Objective: This study was conducted to evaluate clinicians' beliefs, knowledge and other factors that influence the over-prescribing of SUP in low-risk, non-intensive care unit (non-ICU) patients. Method: A cross-sectional survey consisting of multiple-choice queries and close-ended questions was distributed to healthcare personnel at a major teaching hospital in Korea. Results: More than half of total respondents reported that they would continue SUP following patients discharge from the ICU (77.8%, 43.5%, and 39.7% in the physician, pharmacist, and nurse groups, respectively). Over 55% of physicians would also initiate non-ICU patients on SUP upon hospital admission, and 42.6% of physicians would even continue prophylaxis post hospital discharge. The mean knowledge score regarding SUP indications and side effects was higher in pharmacists compared to physicians and nurses (12.44, 7.40, and 7.28, respectively; p<0.001). High-prescribing behavior was associated with a prescriber's belief that SUP is effective for preventing bleeding (odds ratio 7.40; 95% confidence interval 1.57 to 31.94; p=0.012). Low knowledge score and computerized order set also showed statistically significant association with the overutilization of SUP.

Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries (납 축전지의 병렬운전시 부하분담률 개선)

  • 반한식;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제6권1호
    • /
    • pp.34-42
    • /
    • 2001
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy directly without a mechanical process. Unit cells are connected in series to obtain the required voltage, while being connected in parallel to organize capacity for load current and to decrease the internal resistance for corresponding the sudden shift of the load current. Because the voltage droop down in one set of battery is faster than in tow one, it amy result in the low efficiency of power converter with the voltage drop and cause the system shutdown. However, when the system being driven in parallel, a circular-current can be generated. The changing current differs in each set of battery because the system including batteries, rectifiers and loads is connected in parallel and it makes the charge voltage constant. It is shown that, as a result the new batteries are heated by over-charge and over-discharge, and the over charge current increases rust of the positive grid and consequently shortens the lifetime of the new batteries. The difference between the new batteries and old ones is the amount of internal resistance. In this paper, we can detect the unbalance current using the micro-processor and achieve the balance current by adjusting resistance of each set. The internal resistance of each set becomes constant and the current of charge and discharge comes to be balanced by inserting the external resistance into the system and calculating the change of internal resistance.

  • PDF

Modeling the Flushing Effect of Multi-purpose Weir Operation on Algae Removal in Yeongsan River (영산강 다기능보 운영에 따른 플러싱 및 조류 배제 효과 모델링)

  • Chong, Sun-a;Yi, Hye-suk;Hwang, Hyun-sik;Kim, Ho-joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제37권10호
    • /
    • pp.563-572
    • /
    • 2015
  • The purpose of this study was to model the effect of flushing discharge on algae removal by multi-purpose weir operation in Yeongsan River (Seungchon Weir) using a 3-dimensional (3D) model. The chlorophyceae Eudorina sp. formed bloom in May 2013. Flushing discharge was conducted in two different ways for algal bloom reduction. To elucidate the spatial variability, a high-resolution 3D model, ELCOM-CAEDYM, was used to simulate the spatial variations of water quality and chl-a over a month. The results showed that ELCOM-CAEDYM could reproduce highly spatially resolved field data at low cost, and showed very good performance in simulating the pattern of algal bloom occurrence. The effect of each flushing discharge operation was analyzed with the results of modeling. The results of case 1, flushing discharge using an open movable weir, showed that the algal bloom between the Seochang Bridge and the Hwangryong River junction is rapidly flushed after operating the movable weir, but the residual algae remained in the weir pool as the discharge decreased. However, the results of case 2, fixed weir overflow with a small hydropower stop, showed that most of the algae was removed after flushing discharge and the effect of algae removal was much bigger than that in case 1, as per modeling results and observed data.

An Estimation of the Amount of Ship's Ballast Water to be Discharged at Korean Major Ports (국내 주요항만에서의 선박평형수 배출량 추정)

  • Choi, Hark-Sun;Kim, Han-Soo;Lee, Seung-Guk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • 제12권4호
    • /
    • pp.284-288
    • /
    • 2009
  • The International Convention for the Control and Management of Ships Ballast Water & Sediments was adopted by consensus at a diplomatic conference of IMO at 2004. To prepare the Ballast Water Management Convention, fundamental technologies such as treatment system, type approval, risk assessment and various technical informations for formulation of the regulation for national strategy shall be developed. The information item of voyage and discharge of ship's ballast water are gathered by visiting vessel and agent at port. Using the 97 results by ships type characteristic analysis on the relation between loading/unloading and discharge/uptake of ballast water, the amounts of discharge/uptake of ballast water at each port and all of country in Korea are predicted. Hence, It is apparent that the uptake of ballast water is predicted to about 70 million ton in total of Busan, Incheon, Kwangyang and Ulsan ports at 2006 which is over 3 times than discharges.

  • PDF

Application of Nano Coating to ACSR conductor for the Protection of Transmission lines against Solar Storms, Surface Flashovers, Corona and Over voltages

  • Selvaraj, D. Edison;Mohanadasse, K.;Sugumaran, C. Pugazhendhi;Vijayaraj, R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2070-2076
    • /
    • 2015
  • Nano composite materials were multi-constituent combinations of nano dimensional phases with distinct differences in structure, chemistry and properties. Nano particles were less likely to create large stress concentrations and thereby can avoid the compromise of the material ductility while improve other mechanical properties. Corona discharge was an electrical discharge. The ionization of a fluid surrounding a conductor was electrically energized. This discharge would occur when the strength of the electric field around the conductor was high enough to form a conductive region, but not high enough to cause electrical breakdown or arcing to nearby objects. This paper shows all the studies done on the preparation of nano fillers. Special attention has given to the ACSR transmission line conductor, TiO2 nano fillers and also to the evaluation of corona resistance on dielectric materials discussed in detail. The measurement of the dielectric properties of the nano fillers and the parameters influencing them were also discussed in the paper. Corona discharge test reveals that in 0%N ACSR sample corona loss was directly proportional to the applied line voltage. No significant change in corona loss between 0%N and 1%N. When TiO2 nano filler concentration was increased up to 10%N fine decrement in corona loss was found when compared to base ACSR conductor, corona loss was decreased by 40.67% in 10%N ACSR sample. It was also found from the surface conditions test that inorganic TiO2 nano filler increases the key parameters like tensile strength and erosion depth.

Analysis of Flow Characteristics in Upstream Channel depending on Water Gate Operation of Nakdan Multi Functional Weir (수문운영에 따른 낙단보 상류하도 흐름특성 해석)

  • Moon, Sang-Chul;Park, Ki Bum;Ahn, Seung-Seop
    • Journal of Environmental Science International
    • /
    • 제25권4호
    • /
    • pp.491-504
    • /
    • 2016
  • This study, examines the flow characteristics of upstream channel depending on water gate operation of Nakdan Multi-fuctional weir. The specific purpose of this study are to simulate the variation of flow velocity depending on the operation of the weir using 1-dimensional hydraulic model, HEC-RAS, and compare it with observed velocity. For discharge conditions from $50m^3/s$ to $3,500m^3/s$, it is observed that the velocity of upstream channel is almost constant, whereas for probability flood discharge, the velocity and froude number are increased as the discharge values are increased. The velocity values for downstream boundary condition EL, 40.0 m are more decreased than those for EL. 40.5m. From comparison on the variation of water stage depending on water gate operation, it is observed that the stage values are almost constant for discharges below $300m^3/s$, whereas 5 cm to 20 cm for discharges over $700m^3/s$. Flow velocity at streamflow gauging station. Nakdong, is decreased by more than 875% after installing the weir. The results obtained from this study indicate that the velocity of upstream channel is decreased and the discharge and velocity of downstream channel are significantly varied after installing the weir.

Plasma Catalytic Methane Conversion over Sol-gel Derived Pt/TiO2 Catalyst in a Dielectric-barrier Discharge Reactor (DBD 반응기에서 솔-젤 법으로 제조된 Pt/TiO2 촉매를 이용한 메탄의 플라즈마 전환반응)

  • Kim, Seung-Soo
    • Korean Chemical Engineering Research
    • /
    • 제45권5호
    • /
    • pp.455-459
    • /
    • 2007
  • Plasma catalytic methane conversion was carried out in the presence of sol-gel derived $Pt/TiO_2$ catalysts within a dielectric-barrier discharge (DBD) reactor. Plasma-assisted reduction (PAR) was applied to reduce the prepared $Pt/TiO_2$ catalysts in DBD reactor, and prepared catalysts were successively reduced by PAR within 20 min irrespective of the Pt loading and the calcination temperature. The highest methane conversion was 40% when 3 wt% $Pt/TiO_2$ and 5 wt% $Pt/TiO_2$ catalysts were used after calcination at $600^{\circ}C$. The selectivities of light alkanes ($C_2H_6$, $C_3H_8$, $C_4H_{10}$) were highly increased when $Pt/TiO_2$ catalysts were used in DBD reactor.